MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Similar documents
MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: 40DN. Digital Panel Meters 40 Series

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: WL40EW2F. Wireless I/O WL40F Series

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

MODEL: CND. Multiplex Transmission System

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

MIC-2 MKII, Multi-instrument DATA SHEET

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

IST ULTRASTAB Power Supply for high precision transducers

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

SSI-1016H Specifications and Operation Manual

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

FX-485PC-IF RS485 Interface Unit Hardware Manual

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

MODEL: 43DV2. Digital Panel Meters 43 Series

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

General Specifications

TABLE OF CONTENTS. Communication Functions

Thread length (overall length) material

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Power Transducers. Measuring most electrical parameters

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Communications & Networking

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

F150 Vision Controller with integrated PROFIBUS-DP unit. 9-pin female sub-d connector (RS-485 ProfiBus) Bus termination

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

SYSMAC Remote Transistor Module

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Energy Transducer Type ET112

Manual Swipe Magnetic Card Reader

Communication Controller CC-Link/CPL Converter CMC10A

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

I/O Expansion Module Installation & Reference

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

PC RELAY TERMINAL/ PC TERMINAL

2. Actuator B: Ball type P: Pin type F: Flat type

AO561 Analog Output Module

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

MODEL: M8BS-16. [3] OPTIONS blank: none /Q: With options (specify the specification)

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

MIC-2 Multi-instrument DATA SHEET

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SensoTrans DMS A 20220

Programmable Relay ZEN V2 Units

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

RS485 MODBUS Module 6RO

DATA CONNECT ENTERPRISE

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Electronic timer CT-ERD.12

RS-422A/485 Serial I/O Board with Isolation for PCI. Features. Cable & Connector (Option) Product Configuration List.

Transcription:

PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable to spreadsheet applications SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating RELATED PRODUCTS Connector terminal block (model: CNT) Special cable (model: FCN32) 175 (6.89) 115 (4.53) 40 (1.57) mm (inch) MODEL: R1M-D1[1]-[2][3] ORDERING INFORMATION Code number: R1M-D1[1]-[2][3] Specify a code from below for each [1] through [3]. (e.g. R1M-D1T-M2/MSR/Q) Specify the specification for option code /Q (e.g. /C01) PACKAGE INCLUDES... PC Recorder Software CD GENERAL SPECIFICATIONS Connection Power input, transmission: Euro type connector terminal (Wire size AWG24-12 (0.2 2.5 mm 2 ), stripped length 7 mm) : 9-pin D-sub connector (male) (Lock screw No. 4-40 UNC) Input: M3 screw terminals (torque: 0.6N m) or FCN type connector (Fujitsu FCN-365P040-AU) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Isolation: or to output to power Node address setting: Rotary switch; 1 F (15 nodes) RUN indicator LED: Green light blinks in normal conditions. [1] FIELD TERMINAL TYPE T: M3 screw terminals C1: FCN type connector (No CE conformance) [2] POWER INPUT AC Power M2: 100 240 V AC (Operational voltage range 85 264 V, 47 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [3] OPTIONS (multiple selections) PC Recorder Software Package (must be specified) /MSR: With Other Options blank: none /Q: Option other than the above (specify the specification) COMMUNICATION Baud rate: 38.4 kbps Communication: Half-duplex, asynchronous, no procedure Protocol: Modbus RTU Standard: Conforms to, EIA Transmission distance: 10 meters max. Standard: Conforms to TIA/EIA-485-A Transmission distance: 500 meters max. Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) OUTPUT SPECIFICATIONS Output: Open collector, 32 points Commons: All negatives Sampling rate: 50 msec. Rating: 24 V DC @ 50 ma (resistive load) Saturation voltage: 1.6 V DC For use with inductive loads, external protection of contact and noise quenching is recommended. http://www.m-system.co.jp/ R1M-D1 SPECIFICATIONS ES-5658 Rev.16 Page 1/6

INSTALLATION Power consumption AC: Approx. 10 VA DC: Approx. 7 W Operating temperature: -5 to +60 C (23 to 140 F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lb) PERFORMANCE Multi-transmission time: 5 msec. Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute ( or RS- 485 to output to power to FG) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 / or output to power: Reinforced insulation (300 V) / to output: Basic insulation (300 V) RoHS Directive EN 50581 http://www.m-system.co.jp/ R1M-D1 SPECIFICATIONS ES-5658 Rev.16 Page 2/6

PC RECORDER SOFTWARE PC Recorder Software Package (model: MSRPAC-2010) is included with purchases of this model. Refer to the MSRPAC-2010 data sheet for the contents of the package and the requirements for the PC to be prepared by the user. EXTERNAL VIEW Power Terminals 9-pin Connector RUN Indicator LED Connector Node Address Setting Rotary SW Configurator Jack INTERFACE 1 5 ABBR. 6 9 PIN NO. EXPLANATION OF FUNCTION BA (SD) 2 Transmitted Data BB (RD) 3 Received Data AB (SG) 5 Signal Common CB (CS) 7 Clear to Send CA (RS) 8 Request to Send 1 Not Used. 4 DO NOT connect. Connecting may 6 cause malfunctions. 9 MODBUS WIRING CONNECTION CONNECTOR R1M T3 R1M R1M * 1 T3 T3 * 1 FG *2 *1. Internal terminating resistor is used when the device is at the end of a transmission line. *2. Install shielded cables to all sections and ground them at single point. http://www.m-system.co.jp/ R1M-D1 SPECIFICATIONS ES-5658 Rev.16 Page 3/6

CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. FCN TYPE CONNECTOR M3 SCREW TERMINALS CN1 CN2 ch.1 ch.2 ch.3 ch.4 ch.5 ch.6 ch.7 ch.8 ch.9 ch.10 ch.11 ch.12 ch.13 ch.14 ch.15 ch.16 ch.17 ch.18 ch.19 ch.20 ch.21 ch.22 ch.23 ch.24 ch.25 ch.26 ch.27 ch.28 ch.29 ch.30 ch.31 ch.32 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 B1 : B16 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 B1 : B16 Output ch.1 ch.2 ch.3 ch.4 ch.5 ch.6 ch.7 ch.8 ch.9 ch.10 ch.11 ch.12 ch.13 ch.14 ch.15 ch.16 ch.17 ch.18 ch.19 ch.20 ch.21 ch.22 ch.23 ch.24 ch.25 ch.26 ch.27 ch.28 ch.29 ch.30 ch.31 ch.32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Output Input Term. Resist. Power T3 T5 T6 T7 * When the device is located at the end of a transmission line via twisted-pair cable, (when there is no cross-wiring), close across the terminal T3 with the attached jumper pin (or with a leadwire). When the device is not at the end, remove the jumper pin. D-SUB CONNECTOR + U (+) V ( ) FG Shielded Twisted-pair Cable To Other PC Recorders Jumper* POWER http://www.m-system.co.jp/ R1M-D1 SPECIFICATIONS ES-5658 Rev.16 Page 4/6

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) M3 SCREW TERMINALS MODEL: R1M-D1 175 (6.89) 10 (.39) 165 (6.50) T3 T5 T6 T7 3 5 (.20) dia. MTG HOLES 15.5 (.61) 46 (1.81) 105 (4.13) 104 (4.09) DIN RAIL 35 mm wide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 14 (.55) 163 (6.42) FOR WALL MOUNT. 3 (.12) 40 (1.57) [6 (.24)] 6.2 (.24) 36 M3 OUTPUT TERMINALS FCN TYPE CONNECTOR 175 (6.89) 40 (1.57) 10 (.39) 165 (6.50) T3 T5 T6 T7 3 5 (.20) dia. MTG HOLES 15.5 (.61) 46 (1.81) Connector Pin Assignment A1 B1 105 (4.13) 104 (4.09) DIN RAIL 35 mm wide CN1 CN2 See Caution below A16 B16 14 (.55) FCN TYPE OUTPUT CONNECTOR 163 (6.42) FOR WALL MOUNT. 40 (1.57) 3 (.12) [6 (.24)] Caution: DO NOT APPLY EXCESSIVE FORCE onto the connector. The connector may be destroyed. http://www.m-system.co.jp/ R1M-D1 SPECIFICATIONS ES-5658 Rev.16 Page 5/6

SYSTEM CONFIGURATION EXAMPLES / Converter (model: R2K-1) TC/DC Inputs (model: R1M-GH) Contact Inputs (model: R1M-A1) Contact Outputs (model: R1M-D1) When the cable distance between the PC and the R1Ms is long, insert an / Converter for isolation. Specifications are subject to change without notice. http://www.m-system.co.jp/ R1M-D1 SPECIFICATIONS ES-5658 Rev.16 Page 6/6