CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

Similar documents
CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

CLFE(X)IPS INSTALLATION AND OPERATION MANUAL

Ethernet over Copper Transmission Extenders. Ethernet Transmission over Coaxial or UTP Cable. Fiber Optic and Ethernet Network Solutions

CLFE(X)EO(C,U) Series ETHERNET OVER COPPER EXTENDER WITH PASS-THROUGH POE TO 15 WATTS

CWFE(1,2)COAX[M] INSTALLATION AND OPERATION MANUAL

CNFE2MCPOE[/M] 10/100 MBPS 2 PORT MEDIA CONVERTER WITH POWER OVER ETHERNET INSTALLATION AND OPERATION MANUAL

CNFE1CL1MC(-M) Fast Ethernet over VDSL (EoVDSL) INSTALLATION AND OPERATION MANUAL

CL(T,R)VE(1,2)COAX[POE][/M]

CNFE1CL1MC(-M) FAST ETHERNET OVER VDSL (EoVDSL) INSTALLATION AND OPERATION MANUAL

CLFE4+1SMS[POE](C,U) Series 10/100 4TX+1EX ETHERNET SELF-MANAGED SWITCH WITH POWER OVER ETHERNET (POE+)

Classic Kiosk. User Guide. Before operating the unit, please read this manual thoroughly, and retain it for future reference

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

RIO R22 & R44. Quick Start Guide for all variants

QSW16M 16 Chn PoE managed switch

1/4 Guitar / Mic input

CNMC[2]SFP[POE][/M] Series

Always there to help you. Register your product and get support at AEA2000. Question? Contact Philips.

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

C ookie User Manual BC

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8


FVT/FVR10D1E(M,S)[M] 10-BIT DIGITALLY ENCODED VIDEO TRANSMITTER WITH 1 BI-DIRECTIONAL DATA CHANNEL AND 10/100MB ETHERNET

VeniceF16/VeniceF16R/ VeniceF24/VeniceF32

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-200-1CAT-HDIR. Receiver

Intelli-M eidc Quick Start Guide. infinias

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

CNGE2+2SMS[POE][HO] 10/100/1000 MBPS INTELLIGENT REDUNDANT RING GIGABIT SWITCH WITH OPTIONAL POE+ QUICK START GUIDE

This manual describes the installation, setup and operation of this equipment in details.

HDMI to 3GSDI Converter

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

VeniceU16/VeniceU24/VeniceU32

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

MODEL 805 USER MANUAL

SOUNDSTICKS WIRELESS. Setup Guide. Downloaded from

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

CNFE200(X)[POE](M,S)(1,2)[HO][/M]

Media Drive 600 User Guide

DPR-34+ GB Revision 2

FVT/FVR110(M,S)1[/M] 10-BIT DIGITAL VIDEO WITH ONE BI-DIRECTIONAL DATA CHANNEL INSTALLATION AND OPERATION MANUAL

HSC-42. HDMI 4k2k Video Up/Down Scaler

DUAL LASER PACK & CONTROLLER USERS MANUAL

DVI ELR Extender over one CAT5

Dual Link DVI Extender

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

DS-1H05 Ethernet-over-Coax Extender. User Manual

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

KILBURN - PORTABLE ACTIVE STEREO SPEAKER USER MANUAL

Always there to help you. Register your product and get support at SPA1330. Question? Contact Philips.

AZATOM iflute 2. Portable Lightning Docking Station. User Manual. This manual is available to download online at

SONOS DOCK. Product Guide

Ethernet Network Transmission Solutions. Fiber Optic & Ethernet Network Solutions

Us U er e r G u G i u de d AX A 3 X DA D N A T N E T I/O / O Car a d r d

DVI ELR Extender over one CAT5

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

Beamforming Microphone Array 2 Group Microphone for Professional Conferencing. Quick-Start Guide

FOOT CONTROLLER FCV100

U-300 Unity Amplifier User s guide

OWNER S MANUAL CD-2 V 1.3

AZATOM StreetDance Mini 2. Portable Lightning Docking Station. User Manual. This manual is available to download online at

Active UTP Transceiver Hub with Integral Isolated Camera Power

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Quick Start Guide Rio Series R22 and R44 Models

Plug-in wireless speaker

Quick Guide. ENC-H Video Encoder XX

Wireless Audio Soundbar

NEUPANEL SERIES. User Manual for Neutrino/Uno/Rio

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

THANK YOU FOR BUYING HEIMDALL A CLINT HI-FI STREAMING ADAPTER

APT20. User Manual.

Professional Digital Audio Processor. SOLTON DSP 206 Operation Manual

IDIS Co., Ltd. For more information, please visit at

und4o Four Output Dante /AES67 Break Out Interface User Manual Date 8/27/2018 Revision 02_d

1:4 3GSDI Splitter. User Manual EXT-3GSDI-144. Release A5

PORTABLE WIRELESS PA SYSTEM WITH LITHIUM -ION RECHARGEABLE BATTERY AWP6042 OWNER S MANUAL. Handheld Microphone Headset Transmitter

Transceiver Hub with Integral Camera Power

MAJORITY PETERSFIELD. Digital & FM Pocket Radio. Instructions Guide CB1A-DAB-BLK

SBW-175. Audio Soundbar & Subwoofer. Instructions Guide

Always there to help you Register your product and get support at SBT300/12. Question? Contact Philips.

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Always there to help you. Register your product and get support at AS130. Question? Contact Philips.

Majority Longstanton. DAB / DAB+ / FM Radio LNG-DAB-BLK. User Guide

TeleAdapt Roomcast. Installation Guide TA-2400

FOOT CONTROLLER FCV100. Quick Start Guide. Ultra-Flexible Dual-Mode Foot Pedal for Volume and Modulation Control

U-150 Integrated Amplifier User s guide

INSTALLATION GUIDE ER8400U. 8 Port Wall Mounted IP Video Extender Over UTP With Built-In Gigabit PoE+ Switch and EtherStretch.

Operating Instructions

C-300 Preamplifier User s guide

Hardened PoE Ethernet Switch

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

User Manual. AZATOM Venture VT100. This manual is available to download online at

Audio Core 200 User Guide

Network Camera. Quick Guide DC-B1203X. Powered by

Always there to help you. Register your product and get support at DS1600. Question? Contact Philips.

A Watt Stereo Amplifier

User`s Guide SBAR-51. Sound Bar and Docking Station

Transcription:

Ethernet-over-Coax Extender with Pass-Through PoE Important Safety Warning: Read and keep these directions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with a dry cloth Install in accordance with the manufacturer s instructions This installation should be made by a qualified service person and should conform to all local codes See further safety instructions on Page 8 The ComNet CopperLine Ethernet over COAX line consists of four models that support 100Mbps Ethernet as well as Pass-through Power over Ethernet (PoE) over standard 75Ω coaxial cable. These models support transmission distances of up to 5,000 feet (1524m) at 10 Mbps, or 1800 feet (548m) at 100 Mbps. The, the CLFE4COAX, CLFE8COAX and the CLFE16COAX transport, one, four, eight or sixteen channels respectively. The IEEE 802.3-compliant extenders also meets the requirements for IEEE 802.3af PoE power, passing through up to 30 watts of power per port to the powered device (PD). The series may also be used interchangeably with other CopperLine Ethernet-over-Coax extenders. Environmentally hardened to the requirements of NEMA TS-1/ TS-2 for most out-of-plant applications, and true plug-and-play design ensures ease of installation and operation. LED indicators are provided for rapidly ascertaining the operating status of the device. See Figures 7 and 8 on Page 7 for LED explanations. Packaged in a rugged aluminum housing, these units are designed for desktop or standalone mounting. The CLFE8COAX and CLFE16COAX are offered in EIA 19 1U high rack for easy installation. See Figures A through C on Page 8 for mounting instructions. See Figures 1 8 for complete installation details. PAGE 1

FIGURE 1 FIGURE 2 + Power Supply Connection via external power adaptor Optional, if there is no power supply connected to the unit it will try to detect PoE. LEFT PANEL RIGHT PANEL Ground Screw* Note: Center pin on power connector is positive (+). * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. FIGURE 3 CLFE4COAX LEFT PANEL RIGHT PANEL Ground Screw* Note: Center pin on power connector is positive (+). * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. Tech SUPPORT: 1.888.678.9427 PAGE 2

Pass-Through PoE Operations for the ComNet s CopperLine extended distance IP data and PoE maintains the safety standards for communications found within the 802.3af PoE standards. This is for the protection of products operating in the extended distance transmission chain. In the event of malfunctions the communication system is designed to shut down power transmission to avoid device damage. The can be powered by a local power source (12 Volts D.C. or 24 Volts A.C.) or from a single PSE source, such as a network switch s PoE port using its unique Pass Through PoE feature. This latter feature eliminates the need for local power while also providing power for the camera. Using the Remote and Local Switch Set the positioned closest to the camera as Remote Set the positioned closest to the PSE source to Local (See full installation instructions, Page 6) Setting the Position Switch The provides the ability to transmit both data and PoE over RG59 cable. While the is a transceiver as part of the installation, the devices must be set according to their position in the transmission line as the camera and control site location. Powering The Transceivers Under normal operating conditions transceivers should be powered using the PoE source. External power to the Input with external power plug installed. External power adapter (included) should be restricted to installations where a camera requires local power. When installing the, the following conditions apply which will affect its operations. The is provided with the ability to operate using a local external power supply. The standard accessory local power adaptor plug can be used for power supplies that do not have the s standard power input connector. When inserting the adaptor into the power input, the is only powered from a local power source and not from a PSE source. The camera will continue receiving power from the PSE source and operations will be normal. However, if the external plug adaptor is inserted in the and no power is applied, the will not power up even if a PoE source is present, the camera will continue to receive power. In this case the is not operational and no data will flow. PAGE 3

FIGURE 4 CLFE8COAX 12V Power Supply Ground Screw* * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. FIGURE 5 CLFE16COAX 12V Power Supply Ground Screw* * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. PAGE 4

FIGURE 6 POSSIBLE ETHERNET CONFIGURATIONS Multiple Configurations are possible. Consult ComNet Design Center. Single Port CopperLine over Coax NVR PoE Switch CNGE2FE24MSPOE 5,000ft 328ft (1524m) Coax (100m) Cat-5 PoE Camera Multi Port CopperLine over Coax CLFE16COAX 5,000ft (1524m) Coax 328ft (100m) Cat-5 PoE Camera NVR PoE Switch CNGE2FE24MSPOE CopperLine 4-Port Switch Extended over UTP or Coax CLFE16UTP CLFE16COAX 3,000ft (914m) Cat-5 OR 5,000ft (1524m) Coax CLFE4US1TPC 328ft (100m) Cat-5 IP Cameras IP Cameras NVR PoE Switch CNGE2FE24MSPOE CopperLine Managed High Power Midspan NVR 3,000ft (914m) Cat-5 Data + Power CLFE1UTP CLFE1UTP PoE Camera 5,000ft (1524m) Coax Data +Power Switch CNGE2FE24MS CLFE16IPS PoE Camera PAGE 5

IP Camera-end InsTALLATIOn () Set the Remote/Local dip switch to Remote mode. Ethernet Switch/NVR-end InsTALLATIOn () Set the Remote/Local dip switch to Local mode. S1 S2 Set the S1 dip switch to the appropriate rate based on the maximum data rate. OFF = 10BaseT; ON = 100BaseT S1 S2 Set the S1 10/100BaseT dip switch to the appropriate rate based on the maximum data rate. OFF = 10BaseT; ON = 100BaseT Set the S2 switch to On for Master. For systems not utilizing PoE, connect the 12VDC or 24VAC Power Supply to the power connector of the. An external power adapter is provided to simplify connection. If there is no external power source connected, the will try to detect PoE. CAUTION: If the external power adaptor is connected with no power applied, the will not recognize the PoE source and the system will be inoperative. Connect the IP camera RJ-45 connector to the 10/100BaseT Ethernet port of the using a standard Cat5/6 cable, 100m length (max). Connect one end of the long coax cable to the BNC connector of the. Be sure the S2 switch to is set to Off for Slave. Note: The 4, 8 and 16 channel units are preset to Slave/Local mode. No adjustment required. Connect the 12VDC or 24VAC Power Supply to the power connector of the selected If there is no external power source connected, the selected will try to detect PoE. Connect the IP camera RJ-45 connector to the 10/100BaseT Ethernet port of the selected using a standard Cat5/6 cable, 100m length (max). Connect one end of the long coax cable to the BNC connector of the selected. The Link LED on the 10/100 Ethernet connector should be ON to indicate proper connection between the switch and the selected. The Traffic LED on the Coax side should be ON and flashing to indicate proper connection. The Link LED (Red for 100BaseT, Green for 10BaseT) will be ON and not flashing to indicate confirmed connection between the and selected extenders. PAGE 6

FIGURE 7 LED INDICATORS POWER TRAFFIC (Extended) 10/100BaseT GREEN Connection is OK, 10BaseT mode YELLOW RED Power is on Flashing, Traffic present Connection is OK, 100BaseT mode OFF Power is off No traffic FIGURE 8 RJ-45 LED INDICATORS RJ-45 TRAFFIC (Standard) Link GREEN Flashing Connection is OK with traffic YELLOW Connection is OK RED OFF No connection No connection PAGE 7

MECHANICAL INSTALLATION INSTRUCTIONS Installation CONSIDERATIONS The and CLFE4COAX are supplied as Standalone modules. The CLFE8COAX and CLFE16COAX can be installed as Standalone modules or can be rack-mounted with the addition of the provided 19-Inch Rack- Mounting Ear Brackets. Figure A Dimensions are for the standalone ComNet module 1.6" (40mm) 1.15" (30mm) 1.6" (40mm) 4.73" (120mm) Figure B Dimensions are for the CLFE4COAX standalone ComNet module 3.3" (84mm) 1.6" (40mm) 3.6" (92mm) Figure C Dimensions are for the CLFE8COAX and CLFE16COAX ComNet modules 3.25" (82.5mm) 17" (432mm) 1.75" (44.5mm) Tech SUPPORT: 1.888.678.9427 PAGE 8

IMPORTANT SAFEGUARDS Read and keep these directions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Install in accordance with the manufacturer s instructions. This installation should be made by a qualified service person and should conform to all local codes. DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring. To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture, dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the equipment. DO NOT install the unit in a place where the operating ambient temperature exceeds 75ºC. Make sure that the external power supply output voltage is in the recommended range. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including DVRs) that produce heat. Protect the power cord from being walked on or pinched, particularly at the power source, convenience receptacles and the point where they exit from the apparatus. Only use attachments/accessories specified by the manufacturer. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when a power supply cord or plug is damaged, liquid has been spilled, objects have fallen inside the apparatus, the apparatus has been exposed to rain or moisture, do not operate normally or has been dropped. The main plus is used as the disconnect device and shall remain readily operable. WARNING: to reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus. WARNING: this apparatus is a Class I product. This product must be connected to a mains socket outlet through an AC to DC power supply. WARNING: the mains plug is used as the disconnect device and shall remain readily operable. WARNING: For non-poe applications, unit is to be connected to a mains socket outlet through a Listed Class I power supply rated 12 VDC or 24 VAC. 3 Corporate DRIVE DANBURY, CT 06810 USA T: 203.796.5300 F: 203.796.5303 Tech SUPPORT: 1.888.678.9427 INFO@COMNET.net 8 TURNBERRY Park Road GILDERSOME MORLEY LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 F: +44 (0)113 253 7462 INFO-EUROPE@COMNET.net 2012 Communications Networks Corporation. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks, LLC. PAGE 9