PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

Similar documents
PRO2200 Professional Modular Access Control Hardware

PRO3200 Professional Modular Access Control Hardware

Web-based Access Control System. Employee access. EMBEDDED Web Browser

NetAXS. Hosted Video Services. Cloud Hosted Access Control. Retail Professional Services Convenience

NetAXS-123: One door, compact (plastic) enclosure. NetAXS-123: One door, standard (metal) enclosure with tamper switch and terminal block

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

istar Ultra Access Controller For up to 32 Readers 1 Features Supports up to 32 Readers Network Ready 1 / 5

Quick Start Installation Guide

ACTPRO ACCESS CONTROL. Specification Guide

TAC I/NETTM 1284, 1280, Security Control Unit

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

Web-based Access Control System. Lower Cost of Ownership

multinode M2150 INTELLIGENT CONTROLLERS

SYSTEM GALAXY HARDWARE. 635-Series

NetAXS. Cloud-Hosted Services. Cloud Hosted Access Control. Retail Property Management Franchises

SYMMETRY MULTINODE M2150 INTELLIGENT CONTROLLER

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

NetAXS-123: One door, compact (plastic) enclosure. NetAXS-123: One door, standard (metal) enclosure with power supply and battery

IPassan Installation guide

4 balanced inputs 1 relay output

Corporate Commitment to Excellence

Access Easy Controller 2.1

ACS-8-System. Access Control. Performance features at a glance

ACS-8-System. Access Control. Performance features at a glance

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.

ACTpro Single Door IP Controller. Operating & Installation Instructions

Mercury Products Open Platform Solution

Product Feature Matrix

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

TDSi MICROgarde type door controllers offer a fully featured door controller with up to 25,000 card memory.

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL

ACCESS CONTROL SYSTEM

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

ACX Series. Access Controller for Ethernet

Control Panel Solutions

T h e re is an upgrade route to larger configurations. O v e rv i e w

Access Control Unit User s Guide

6222 Two Door Module Technical Operations Manual

ACTpro 1500 Single Door IP Controller

Compass RTU Guide. Version 3.x

Architectural and Engineering Specification. Brivo ACS 5000 Control Panels and ACS Service

Access Easy Controller V 1.0

Symmetry M2100 Controller

Controller 3000, dependent on reader technology and site configuration. All I/O functionality is provided on the Controller 3000.

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

MR52 READER INTERFACE

IQ Series Architect/Engineer Guide Specification P/N Revision 5.0

Access control panel U-Prox IC E (Elevator control)

Access Easy Control System. Reference Guide

This is Cansec s 25th anniversary. Many of

SINGLE READER EXPANSION MODULE

ACCESS CONTROL Products 2017

Suprex RS-485 SPX-7500 Wired Reader-Extender

FACIAL RECOGNITION TERMINAL SYSTEM

SiPass Entro. Open the door to comprehensive security.

CardaxFT Reader I/O Interface

MR51e Reader Interface

U-FLASH Setup Guide U-FLASH.

2000 Series e/em Style Keypad Installation and Programming Manual

Andover ContinuumTM Infinet II

Intelligent Four Lift Controller TS0869

AXP-400. Enterprise. Access Solution

EP1501 Intelligent Controller

Click Save to return to the main Setup screen.

Installation & User Manual

GV-AS Controller. Installation Guide

Keyscan CA150 PoE Single Door Controller

EA500. Installation Instructions Transponder

Installation & Operation Guide

Andover ContinuumTM Infinet II

VICON ACCESS CONTROL CONTROLLERS

Two Door Controller GEN-045

GLOSSARY. See also: Access point

S700e Intelligent IP Reader S700 Exit Reader

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Powering the enterprise-grade mobile access experience.

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

KeyWatcher Illuminated Specifications

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL

BACnet. b3810 Series Local Controllers

CA-A480-A Elevator Controller. Reference & Installation Manual

High Definition IP Video. Just Like Growing Your Business with NetAXS-123. Open Your World!

Building Technologies. Access Control SiPass networked - simple & networkable for everyday use

GETTING STARTED. Installing the System 2000 Hardware. Configuring Your System 2000 Hardware. Troubleshooting. Configuring Your System 2000 Network

PRxx1 series controllers Functional Description and Programming Guide

RFID PRODUCT AND SYSTEM

Proximity Card and Pin Reader Installation Manual

Door release elements and Multitechnology-Reader

KP2000E/EM Series Style Keypad

Product Overview. Revision 1.3

Quick Selection Guide Avigilon Access Control Manager

Professional Access Control

UC-2000 Installation Manual Unicorn Computers Technology Limited

PRT-RDS2 Standard 2 Reader Expander

Installation & User Manual V2.08

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

SmartLock Controller INSTALLATION MANUAL

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

BioStar 2. Web-based Open Integrated Security Platform

Andover ContinuumTM. b3850 Series Terminal Controllers

Transcription:

Modular Access Control System The next generation of the PW-Series family improves on the existing PW technology to offer superior features and benefits. The PW-Series Modular Control System is an advanced access control hardware architecture capable of providing solutions for large enterprise applications whilst the Intelligent Controller (PW6K1IC) provides power and flexibility with its 32-bit architecture, TCP/IP support, flash memory, large local cardholder database, and large reader and I/O module support. The Intelligent Controller is designed to operate off-line, making access control decisions independently from a PC or other controlling device. It can also be connected to a host computer for system configuration, alarm monitoring and direct control. Connectivity to the host computer is accomplished via direct serial communication (RS232 or RS485), dial-up modem, or TCP/IP network connection. The PW-6000 has Ethernet directly embedded and will support a second Ethernet connection. The PW-6000 will support up to 300,000 cards and 50,000 transactions. The Access Control Modules are controlled by and connected to the intelligent control module PW6K1IC through a supervised RS485 bus at 38,400 bps. Hardware interface configuration options are stored in the intelligent control module and may be directly controlled via operator intervention, time schedules, or event-based procedures. The PW6K1IC Intelligent Controller supports any combination of up to 32 I/O or reader boards to monitor alarm input points, relay output points and access control reader interfaces. By offering a modular design, the system can be tailored to meet a wide range of applications, while optimising cost and mounting space. The Access Modules have been designed to allow for a modular customisable solution. The PW6K1R2 provides I/O support for two card access readers. In the event that communication to the intelligent control module is lost, the readers can be individually configured to allow entrance based on security needs. This customisation allows for a door to be configured as locked or unlocked, or accessed only via valid facility code. The PW6K1R2 also has an RS485 serial port to facilitate communications to third party reader and field device controllers. The PW6K1OUT interfaces with the intelligent control module (PW6K1IC, PW5K1IC or PW3K1IC) providing up to 16-relay output control 12 relays on the front edge. Relays may be used for elevator control, status annunciation and for general facility control, such as door monitoring. The PW6K1IN interfaces with the intelligent control module (PW6K1IC, PW5K1IC or PW3K1IC) providing 16 supervised alarm inputs. An analog to digital converter samples the input values and the digitised result is filtered and processed. Filter parameters are configurable for each input point, resulting in the ability to specify a custom end-of-line (EOL) resistance value, sensitivity range and timing parameter. The PW-Series Access Modules have been designed to accommodate various mounting options. Units can be wall mounted in a high density configuration (PW5K2ENC1) when space is limited, a 19" rack configuration (PW5K2ENC2), or in a tile mount configuration (PW5K1ENC3). The PW-6000 controller utilises a built-in Web server to configure the hardware attributes of the controller.

Modular Access Control System KEY FEATURES ACCESS MODULES Modular design fits a wide variety of applications User programmable relay outputs allow for specific control needs User programmable alarm inputs offer flexible system configuration and control RS485 communication to all modules Dedicated cabinet tamper and power monitor inputs Analog to digital converter technology provides digital filtering and input conditioning Supports the choice of Normally Open/Normally Closed, supervised, and non-supervised circuits Supports a wide range of reader technologies including Wiegand, magnetic stripe, proximity, clock data and keypad Up to nine modules, power supply and battery can be accommodated by the PW5K2ENC1, PW5K2ENC2, and PW5K2ENC5 enclosure System off-line modes customisable per reader include facility code access, locked (no access), and unlocked (full access) Supports multiple reader and card formats for maximum flexibility and security options Operating modes include locked, unlocked, facility code, card only, card and PIN, card or PIN and PIN only Compatible with PW-6000 module, allowing systems and add-ons to be built with either version Any combination of 32 I/O or reader modules may be connected to the PW6K1IC RS485 port. 1,250 meters total bus length per port Alarm circuit type Normally Open/Normally Closed, non-supervised, supervised (with correct EOL) UL294 / UL1076 and CUL Listed CE Certified KEY FEATURES INTELLIGENT CONTROLLERS Up to 12 intervals per time zone where each interval is a start time, stop time and day map. The day map indicates the day of the week or holiday 255 possible holidays are defined by a starting date and duration Automatic calculation of leap year and Daylight Saving Time 9-digit (32-bit) user ID standard / 15-digit maximum Support for FIPS long card numbers Activation and deactivation dates by card Up to 32 access levels per card or individual time zones per readers Up to 8-digit Personal Identification Numbers (PIN) Operating modes include locked, unlocked, facility code, card only, card and PIN, card or PIN, and PIN only Strike modes include fail-safe and fail-secure Entire card bit-stream reported with invalid facility code or invalid card format Anti-passback support free pass and exempt flags, last area accessed, last reader accessed and time/date of last access Configurable as standard, entry delay latching, entry delay non-latching and exit delay Configurable as standard (energise to activate) or failsafe (de-energise to activate) Pulse control: single pulse (up to 24 hours) or repeating pulses (on/off in 0.1 second increments, up to 255 times) AES FIPS 197 Encryption PW-6000 Web server for hardware configuration UL294, UL1076 Listed CE Certified Up to eight card formats per reader

BENEFITS True 32-bit microprocessor provides fast transaction processing for the most demanding network applications Modular hardware architecture provides flexibility and expansion capabilities Flash memory allows new versions of firmware to be downloaded from the host computer to the controller(s) through the central network Large, local controller database allows access control decisions to be made by controller in real time without the need to communicate to the server Scalable architecture ensures optimal performance with a seamless upgrade path to accommodate future growth beyond its initial installation Seamless support for TCP/IP protocols to allow intelligent controllers to tap into a LAN or WAN connectivity Supports multiple reader and card formats for maximum flexibility and security options Multiple communication methods provide redundant paths for more robust system connectivity Supervised communication and Lithium battery backup ensures system reliability System offline modes customisable per reader include facility code access, locked (no access), and unlocked (full access) Redundant communication port feature allowing secondary port communication if primary fails Anti-passback support free pass and exempt flags, last area accessed, last reader accessed and time/date of last access Modular hardware architecture provides flexibility and expansion capabilities Large, local controller database allows access control decisions to be made by controller in real time without the need to communicate to the server Scalable architecture ensures optimal performance with a seamless upgrade path to accommodate future growth beyond its initial installation Four-state alarm input circuits - NO/NC, non-supervised, supervised (w/eol) Flexible mounting options allow for rack or tile mounting Alarm conditioning with programmable sensitivity and hold time ADA compliant allowing expanded door times selectable per reader Selectable reader states include card and PIN, card only, PIN only or card and PIN Auto switching power supply allows 110/220 operation with PW5K2E2PSE System off-line modes customisable per reader include facility code access, locked (no access), and unlocked (full access) Supports multiple reader and card formats for maximum flexibility Faster Processor - Freescale ColdFire 5282 Processor 32MB RAM and 16MB Flash - More Memory (larger databases) Integrated Ethernet - Faster Downloads (100mbit), Less configuration time then current add on board Store Configuration and User Database in Flash and recover Embedded WebServer for ease of configuring key hardware attributes Status LEDs for all the Inputs on every board Same serial port can be used to talk to Smart Card Readers

Modular Access Control System SPECIFICATIONS Database: Cardholders: - 300,000 on PW-6000 Transaction storage: - 50,000 on PW-6000 Flash programming for firmware revision updates Access codes: virtually unlimited Holidays: virtually unlimited Time codes: 255 Card reader formats: 8 per reader Credential facility codes: 8 Elevator support: 128 floors Dedicated tamper alarm Dedicated power fail alarm Real time clock: - Geographic time zone support - Daylight Saving Time - Leap year support - 4 bit parallel accurate to 50 ppm Database values may exceed current limitations of some security management systems Communication Modules: Primary communication support: - RS232 - RS485 - Dial up modem - Ethernet (TCP/IP) Communication speed: 38.4 KBps Redundant communication support, automatic dial back: PW6K1IC - Dial back on alarm condition - Dial back on transaction buffer capacity reached - Dial back on primary power loss Second on-board Ethernet (TCP/IP) on PW-6000 Download functionality: - System functional during system download: Yes - System functional during credential download: Yes Access Modules: PW-6000 2 RS485 ports supporting 32 total devices PW-Series Dual Reader Module (PW6K1R2) 2 reader ports - 12 VDC at 50 ma, clock/data or data0/data1 Keypad multiplexed with card data Two-wire or one-wire bi-colour LED support Buzzer support only with one-wire LED control 8 supervised, general purpose alarm inputs with programmable circuit type (only 6 available when using PW5K2ENC1 and PW5K2ENC2 enclosures) 2 dedicated alarm inputs for tamper detection and power loss 2 general purpose output relay, form-c, 5 A 28 VDC 4 general purpose output relay, form-c, 2 A 28 VDC (only 2 available when using PW5K2ENC1 and PW5K2ENC2 enclosures) PW-Series Sixteen Output Module (PW6K1OUT) 2 dedicated alarm inputs for tamper detection and power loss 16 general purpose output relay, form-c, 2 A 28 VDC (only 12 are available when using PW5K2ENC1 and PW5K2ENC2 enclosures) 16 alarm input module PW-Series Sixteen Input Module (PW6K1IN) Module Specifications: 2 dedicated alarm inputs for tamper detection and power loss 16 general purpose inputs with programmable circuit type 2 general purpose, form-c, 2 A 30 VDC relays (only one available when using PW5K2ENC1 and PW5K2ENC2 enclosures) Operational Functionality: Duress detection Operational modes: - Credential only - PIN only - Credential or PIN - Credential and PIN - Facility code only Maximum PIN size: 8 digit Door object support Threat level support: 100 levels Two person access rule Offline modes (selectable per reader): - Facility code access - Locked (no access) - Unlocked (free access) Anti-passback support: - While preventing access (hard) - While allowing access (soft) Transaction prioritisation: 999 levels Reader Support: HID Indala OmniProx OmniClass DigiReaders Wiegand Keypads OmniAssure Readers and Credentials: Prox: - OmniAssure w/prox - OmniProx - HID Prox - DigiReaders - Indala Readers Smart: - OmniAssure - OmniClass - iclass - Mifare - DESFire Keypad Magstripe Wiegand

COMMON SPECIFICATIONS Enclosure Dimensions: Board: 228.6 mm H x 139.7 mm W x 25.4 mm D PW5K2ENC1: 353.0 mm H x 431.8 mm W x 228.6 mm D PW5K2ENC2: 353.0 mm H x 480.0 mm W x 228.6 mm D PW5K1ENC3: 355.6 mm H x 406.4 mm W x 114.3 mm D Environment: Temperature: 0 to 70 C operational; -55 to 85 C storage Humidity: 0 to 95% RHNC Wire Requirements: Power - twisted pair, 18 AWG RS485-24 AWG, 1,200m max, 2 twisted pairs with shield (120 W, 23 pf, Belden 9842 or equiv.) RS232-24 AWG, 7.6m max Alarm input - twisted pair, 30 ohms max Communication Features: RS485 port, 1,250m total bus length Standard speed is 38,400 bps PW-SERIES CONFIGURATION

Modular Access Control System COMPATABILITY CHART PW6K1IC PW6K1IN PW6K1OUT PW6K1R1 PW6K1R2 PW3K1IC PW5K1IC PW5K1IN PW5K1OUT PW5K1R1 PW5K1R2 PW5K1ENE PW5K1IC Only PW5K2E2PSE PW5K1DCC PW5K2ENC1 PW5K2ENC2 PW5K1ENC3 ORDERING Part Code Description PW-6000 Intelligent Control System PW6K1IC PW-6000 Intelligent Controller Capacity for 32 I/O or reader boards PW6K1IN PW-Series 16 input module PW6K1OUT PW-Series 16 relay output module PW6K1R2 PW-Series dual reader module Part Code Description Enclosures and Accessories PW5K2ENC1 PW-Series high density enclosure (power supply and battery not included) PW5K2ENC2 PW-Series high density enclosure for 19" rack installations (power supply and battery not included) PW5K2E2PSE PW-Series 110/220 VAC, 4 amp power supply for PW5K2ENC1 and PW5K2ENC2 enclosures PW5K1ENC3 PW-Series remote enclosure PW5K1DCC PW-Series daisy chain cable Pro-Watch is a registered trademark of Honeywell International Inc. Microsoft, Microsoft BackOffice and Windows 2000 registered trademarks of Microsoft Corporation For additional information, please visit www.honeywell.com/security/uk Honeywell Security Group Aston Fields Road Whitehouse Industrial Estate Runcorn Cheshire WA7 3DL Tel: 08448 000 235 www.honeywell.com HAS-PW6000-02-EN(0211)DS-E February 2011 2011 Honeywell International Inc.