Circuit Breaker Analyzer & Timer CAT-P

Similar documents
Circuit Breaker Analyzer & Timer CAT-P

Circuit Breaker Analyzer & Timer CAT-P

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT31

CAT I series Circuit Breaker Analyzers & Timers

CAT I series Circuit Breaker Analyzers & Timers

CAT II series Circuit Breaker Analyzer & Timer CAT64B

CAT II series Circuit Breaker Analyzers & Timers

CAT II series Circuit Breaker Analyzer & Timer CAT65A

CAT II series Circuit Breaker Analyzers & Timers

Micro Ohmmeter RMO200G

BVS Series Battery Voltage Supervisor

BVR Series Battery Voltage Recorders

Handheld Micro Ohmmeters RMO-H series

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

CBA HV Circuit Breaker Analyzer and Microhmmeter

A P P L I C A T I O N

CBA 1000 CHARACTERISTICS

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Circuit Breaker Analyzer System

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

CIBANO in-1 test system for medium- and high-voltage circuit breakers

EGIL Circuit breaker analyzer

DRTS 33. The new generation of advanced three phase relay test set

EGIL Circuit breaker analyzer

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

EGIL Circuit breaker analyzer

DRTS 66 can test all the following relays

CT-8000 S3. digital circuit breaker analyzer

CT-7500 S2. Advanced Test Equipment Rentals ATEC (2832) digital circuit breaker analyzer

Series Watt DC Power Supplies

Advanced Test Equipment Rentals ATEC (2832)

CT-8000 S3 digital circuit breaker analyzer

MJÖLNER 200 Micro-ohmmeter

3 analog linear/rotary transducers and 3 digital transducers inputs for travel/ speed analysis

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

DIGITMR S2 PC. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

2020 System Calibrator

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

CT-6500 S2. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

Fluke Connect Modules Technical Data

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

Models PEL 102 & PEL 103

Fluke 3000 FC Series Test Tools Technical Data

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

SM100. On-Line Switchgear Condition Monitoring

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

MPQ2000. Portable Power Quality Analyzer. IEC Class A compliance. Powered off of phase A voltage ac/dc Vac and 1000 Vdc range

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Ordering Information CIBANO 500

Detailed Specifications 6 1/2 Digits High-Performance DMM

Testing Instruments Manufactured by

PRODUCT. Data Sheet. The new Fluke-289 Advanced Logging Multimeters with Trend Capture

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

DATE: 18/01/2011 DOC.SIE10166 REV.10 CIRCUIT BREAKER ANALYZER AND MICROOHMMETER MOD. CBA1000

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

DATE:25/07/2016 DOC.SIE10169 REV.14

MJÖLNER 600 Microhmmeter

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

PRODUCT. Data Sheet. Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Model A Mini AC/DC Clamp Meter. User's Guide

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Tri-Phase. true 3-phase transformer turns ratio tester

RT4F-48V/50A-WAC RECTIFIER

Digital Clamp-on Meter Instruction Manual

Model PEL 102. POWER QUALITY ANALYZERS, METERS & LOGGERS Power & Energy Loggers PEL 100 Series

LKAT2 OEM. Bi-Directional High Current Measurement with Rectifier Protection. Key Features. Description. Application

power quality Models 8230 & 8220

RT4F-110V/25A RECTIFIER

em4 Accessories Digital expansions

MIC-2 MKII, Multi-instrument DATA SHEET

PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Mini Digital Multimeter

MACROTESTG1 Innovative multifunction Earth Ground Resistance and Earth Resistivity tester with Touch-screen display

Models PEL 102 & PEL 103

Comprehensive next generation breaker condition monitor

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

PQA823 PQA824 Rel /09/12

Digital Clamp Meter User Manual

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

SLI 15 INVERTER SERIES, 1500 W

Introduction. Chapter 2

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

Transcription:

Circuit Breaker Analyzer & Timer CAT-P Simple and easy to operate Lightweight On-line measurement (First trip test) Off-line measurement 3 timing channels (3 x 1) for main contacts DC voltage measurement DC current measurement Touch screen color display 145 mm (5.7 in) On-site analysis of test results Test results analysis using DV-Win software External and internal power supply Description Handheld Circuit Breaker Analyzer & Timer CAT-P is a digital instrument for circuit breakers condition assessment. CAT-P records timing graphs of main arcing contacts, DC substation battery voltage, Trip and Close coil currents. Main contacts operating time in on-line mode is calculated based on AC secondary CT s currents. The timing channels record closing and opening of the main contacts. CAT-P provides an easy selection of different operating modes: Trip (O) Close (C) Tripfree (CO) Trip-Close (O-C) Close-Trip (C-O) Trip-Close-Trip (O-C-O) First trip (O) Before the start of the test, the current clamp needs to be connected to the auxiliary circuitry of the circuit breaker. The measurement starts when the connected current clamp senses the current flow through the auxiliary circuit, Trip or Close coil, depending on the initiated operation. CAT-P is a powerful diagnostic tool for recording and analyzing: Trip/Close coils condition Main contacts operating time Auxiliary contacts condition and operating time Circuit-breaker substation battery condition CAT-P displays numerical and graphical results (it can overlay up to 4 records in graphical form). This enables quick onsite analysis of potential defects by comparing the obtained test results. 1

Features DC current clamp Offline Module interface DC voltage Touch screen color display 145 mm (5.7 in) Alphanumeric keypad Soft keys Power indication Power ON/OFF DC power supply Flash drive PC communication AC clamps 2

Application The list of the instrument applications includes: Off-line and on-line testing of circuit breakers Timing measurement of up to 3 main contacts (1 break per phase) and auxiliary contacts A measurement of the coil currents Evaluating the state of the substation s battery by presenting the voltage value graphically Online measurement (First Trip monitoring test) Timing Measurement (Off-line Test) Timing measurement tests fulfill all the requirements stipulated in IEC 62271-100 and ANSI C37.04-1999. Synchronization between the circuit breaker poles during opening shall not exceed 1/6 of the rated frequency cycle (3,33 ms at 50 Hz; 2,78 ms at 60 Hz) and during the closing shall not exceed 1/4 of the rated frequency cycle as well (5,0 ms at 50 Hz; 4,17 ms at 60 Hz). Auxiliary contacts are mechanically driven by the operating mechanism and are used for control and indication of the main contacts state. There are no general requirements related to timing measurement of auxiliary contacts, described in IEC and ANSI standards. However, in order to assess conditions of high-voltage circuit breakers, it is important to check their operation. Type "a" contact is opened/closed when the circuit breaker main contacts are opened/closed, while type "b" contact is opened/closed when the circuit breaker main contacts are closed/opened. Type "a" contact is connected in series to the trip coil. It interrupts the trip coil circuit when the circuit breaker opens. Type "b" contact is connected in series to the closing coil, interrupting the closing coil circuit when the circuit breaker closes. 3

First trip test (Online test) First trip analysis is important to determine a condition of the coil operating mechanism. A circuit breaker spends most of its lifetime conducting a current without any operation. Once the protective relay detects a problem, the circuit breaker, that was idle for maybe a year or longer, has to operate as fast as possible. However, if the circuit breaker has not been operated for a long time, the latch friction may increase. Information about the latch friction can be obtained from the coil current waveform recorded during the First trip test. When the breaker is in service, the conventional way of offline timing measurement with timing cables across the interrupter cannot be used. Instead of the main contact timing cables, current clamps are used. These current clamps show current flowing through the secondary side of the current transformer in each phase. The instant when the current stops flowing reveals the breaker trip time. 4

DV-Win DV-Win application software suite provides acquisition and analysis of the test results. Graphical presentation of a variety of measurements and timing test results uses cursors and powerful zoom functions for detailed analysis. Colors, grids, scales and positioning of the test data are all controlled by the user. DV- Win supports an automatic unit conversion (e.g. cycles to seconds or mm to inches). The test records can be exported in.dwc file format for further analysis. DV-Win Main Features Downloading the test results from the Selecting the measurement points and instrument to PC intervals using the two cursors Acquisition and analysis of the test results Zoom and pan graph feature The test results can be viewed, edited, Specific test sequence setup saved, printed and exported Customized configuration of the test result Viewing and overlaying several graphs, for graphs an easy test result comparison 5

Technical Data Main contact inputs Number of contact inputs: 3 (3 x 1), 1 per phase Each channel detects Main contacts - Closed 10 Ω - Resistor contacts range 10 Ω to 5 kω - Open 5 kω Open circuit voltage: 20 V DC Short circuit current 50 ma Time measurement Time measurement resolution: 0,05 ms for 1 s test duration (sampling rate 20 khz) 0,1 ms for 2 s test duration (sampling rate 10 khz) Time accuracy: 0,05% of the reading ± resolution Breaker operation Close (C) Trip (O) Close-Trip (C-O) Trip-Close (O-C) Trip-Close-Trip (O-C-O) First trip test The user can select any desired test sequence DC Current Clamps Nominal current: 300 A RMS or 450 A DC PK Measuring ranges: 30/300 A Frequency range: DC to 20 khz (-3 db) AC Current Clamps Measuring Range: 0,05 A to 5 A RMS Accuracy: ±3% ±1 mv (from 0,05 A to 0,5 A), ±1,5% ±1 mv (from 0,5 A to 1 A), ±1% (from 1 A to 5 A) DC Voltage Measurement Range: ±300 V Typical accuracy: ±0,5% RDG ±0,5% FS Guaranteed accuracy: ±1% RDG ±1% FS Handset Power Supply 12 V DC, 0,5 A Inline Power Supply Input: 90 264 V AC, 50/60 Hz Internal Battery Supply 2 x 3,7 V, 2900 mah rechargeable Li-ion battery 8 hours under normal usage Display Touch screen color display 145 mm (5.7 in) Graphic and numeric results Warranty 3 years Applicable standards Installation category: II Pollution degree: 2 Safety: LVD 2006/95/EC (CE Conform) EN 61010-1 EMC: Directive 2004/108/EC (CE Conform) Standard EN 61326-1:2006 CAN/CSA-C22.2 No. 61010-1, 2nd edition, including Amendment1 Environmental conditions Operating temperature: -10 ºC to + 55 ºC / 14 ºF to +131 ºF Storage & transportation: -40 ºC to + 70ºC / -40 ºF to +158 ºF Humidity 5 % - 95 % relative humidity, non condensing All specifications herein are valid at ambient temperature of + 25 C and recommended accessories. Specifications are subject to change without notice. 6

Main Contact Cables 5 m (16.4 ft) with alligator clamps (A1)* Main contact interface cable 5 m* Voltage sense cable set 2 x 5 m (16.4 ft) 2,5 mm 2 (13 AWG) with banana plugs* Dolphin clip (red, black) Current clamp 30/300 A power supplied from the instrument with extension 5 m (16.4 ft) AC Current clamp 1 A / 1 V with cable 5 m (16.4 ft) Extension cable 5 m (16.4 ft) for AC Current clamp 1 A / 1 V Offline Module Plastic transport case - medium size Cable bag *The cables are also available in several lengths and terminations. **The linear analog transducers are available in several lengths. Please contact DV Power for more information. 7

Order info Instrument with included accessories Handheld Circuit Breaker Analyzer & Timer CAT-P DV-Win PC software including USB stick and USB cable Mains power cable with adapter Recommended accessories Main Contact Cables 5 m with alligator clamps (A1) Main contact interface cable 5 m Voltage sense cable set 2 x 5 m 2,5 mm 2 with banana plugs Dolphin clip (black) Dolphin clip (red) Current clamp 30/300 A power supplied from the instrument with extension 5 m AC Current clamp 1 A / 1 V with cable 5 m (x 3) Extension cable 5 m for AC Current clamp 1 A / 1 V Offline Module Plastic transport case - medium size Cable bag Optional accessories Voltage sense cable set 2 x 2 m 2,5 mm 2 with banana plugs Voltage sense cable set 2 x 10 m 2,5 mm 2 with banana plugs Test probe with grip jaws (black) Test probe with grip jaws (red) Test probe with split test clamps (black) Test probe with split test clamps (red) Extension cable 10 m for AC Current clamp 1 A / 1 V Main Contact Cables 10 m with alligator clamps (A1) Main Contact Cables 5 m with alligator clamps (A2) Main Contact Cables 10 m with alligator clamps (A2) Main contact interface cable 2 m Main contact interface cable 10 m Article No CATP000-N-00 Article No CMP-05-4BPA1 E1P-05-7NMNM C2-05-02BPBP DOLPIN-CL-B0 DOLPIN-CL-R0 CACL-0300-06 CACL-AC00-05 CACL-ACE-N05 MC-MODULE-00 HARD-CASE-PM CABLE-BAG-00 Article No C2-02-02BPBP C2-10-02BPBP TESTPR-GJ-B0 TESTPR-GJ-R0 TESTPR-SC-B0 TESTPR-SC-R0 CACL-ACE-N10 CMP-10-4BPA1 CMP-05-4BPA2 CMP-10-4BPA2 E1P-02-7NMNM E1P-10-7NMNM IBEKO Power AB Contact Stockholmsvägen 18 Phone: +46 70 0925 000 181 50 Lidingö, Sweden E-mail: sales@dv-power.com 8