HAT162 ATS CONTROLLER USER MANUAL

Similar documents
HAT160 ATS CONTROLLER USER MANUAL

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

HAT530 ATS CONTROLLER USER MANUAL

HVD300 VOLTAGE DETECTION RELAY MULTIFUNCTIONAL PROTECTION MODULE USER MANUAL

HAT260 ATS (Automatic Transfer Switch) Controller USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

HPT300 POWER CONVERT MODULE USER MANUAL

ATS CONTROLLER OPERATING MANUAL

HAT270A ATS (Automatic Transfer Switch) CONTROLLER OPERATING MANUAL Smartgen Electronics

DIN16A DIGITAL INPUT MODULE USER MANUAL

CMM366-3G CLOUD MONITORING COMMUNICATION MODULE USER MANUAL

SGB100 BLUETOOTH COMMUNICATION MODULE

HAT72 ATS CONTROLLER USER MANUAL

SG72A COMMUNICATION MODULES USER MANUAL

HMC9000A DIESEL ENGINE CONTROLLER (With J1939 Interface) USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD.

Manual TU510A. Auto Transfer Controller HM1043ER1

HGM7200/HGM7100A Series Automatic Genset Controller User Manual Smartgen Technology

APC715 Pump Unit Controller USER MANUAL. Smartgen Technology

DEEP SEA ELECTRONICS PLC

HGM9510 Genset Parallel (With Genset) Unit USER MANUAL. Smartgen Technology

HGM9520 Genset Parallel (With Mains) Unit USER MANUAL. Smartgen Technology

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

DATA SHEET Compact Genset Controller, CGC 200

DEEP SEA ELECTRONICS PLC

ALC404 LIGHTING TOWER CONTROLLER USER MANUAL

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Quick Start Guide TS A

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd.

[ ACD-S ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

FLOW MONITOR & TRANSMITTER

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Motor Control and Protection Unit M10x AO Module User Guide

LE ELECTRONICS Pvt. Ltd.

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

TSC 80 TRANSFER SWITCH CONTROLLER INSTALLATION, OPERATING & SERVICE MANUAL

EM2020 Selectable AC transducer A (UK)

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

100% electricity. Automatic transfer switch controllers ATL series

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

EC700. Pulses concentrator. User instructions

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

ict contactors EN 61095, IEC 1095 Interference

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Can eliminate static charge over an extensive range

Technical Specificaions. kwh Energy Meter

QUICK START GUIDE Paralleling and Protection Unit PPU 300

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Earth-fault Relay SPAJ 110 C. Product Guide

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Wall-/Pipe Mounted Universal Process Indicator

FY Series Digital PID Controller Operation Manual FY400 FY700 FY800 FY900 FY600

Residual overvoltage relay

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

NPW800R RETROFITTING. Power and Volatge Protection Relay

Tempco Instruction Manual

FLS M9.06. ph/orp MONITOR

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

HIGH-VOLTAGE DC METER

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

MIC-2 Multi-instrument DATA SHEET

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

Technical Specifications. Dual Source kwh Energy Meter

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Series 230 Automatic Transfer Switch

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

SX90 Process Controller

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Clear Benefits of the KRAL Electronic.

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

C160 Wall-/Pipe Mounted Universal Process Indicator

Series 230 Automatic Transfer Switch

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Operating Instructions. For. Level Control Module. Model SSR 1000

High Voltage DC Meter

CONTENT Warning...1 I.Brief Introduction...3 II.Electrical Symbol...4 III.Series Model...4 IV. Technical Specifications...4 V.

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Transcription:

HAT162 ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD.

Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951 0086-371-67981000(overseas) Fax: 0086-371-67992952 Web: www.smartgen.com.cn www.smartgen.cn Email: sales@smartgen.cn All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder. Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. SmartGen Technology reserves the right to change the contents of this document without prior notice. Table 1 - Software Version Date Version Content 2018-05-10 1.0 Original release

CONTENTS 1. OVERVIEW... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATION... 5 4. OPERATION... 6 4.1 FRONT PANEL DESCRIPTION... 6 4.2 KEY FUNCTION DESCRIPTION... 6 4.3 INDICATOR DESCRIPTION... 7 4.4 OPERATION... 7 4.4.1 AUTO/MANUAL MODE SWITCH... 7 4.4.2 MANUAL OPERATION... 7 4.4.3 AUTO OPERATION... 7 4.4.4 MANUAL TEST... 8 5. CLOSE FAULT ALARM... 8 6. CONNECTION... 9 7. DEFINITION AND RANGE OF PARAMETERS... 10 8. PARAMETERS SETTING... 13 8.1 PARAMETERS SETTING MODE... 13 8.2 PARAMETERS SETTING... 13 8.3 RESET TO DEFAULT... 14 9. TYPICAL APPLICATION... 15 10. OVERALL DIMENSION AND PANEL CUTOUT... 19 10.1 CASE DIMENSION... 19 10.2 CUTOUT... 19 10.3 INSTALLATION... 20 11. TROBLESHOOTING... 21 HAT162 ATS Controller 2018-05-10 Version 1.0 Page 3 of 21

1. OVERVIEW HAT162 ATS Controller is suitable for no breaking two stage ATS. It can accurately detect 2-way-3-phase voltage and judge voltage abnormal (such as over voltage, under voltage, over frequency, under frequency, lack of phase and phase rotation), and then control ATS to switch. When ATS switches abnormally, the controller can detect close/open failure and alarm on the front panel to ensure the correct action of ATS. In auto mode, if source 1 failure, controller will send signal to start the genset. Moreover, it can also realize remote communication, remote control and parameter configuration functions via LINK port communication. 2. PERFORMANCE AND CHARACTERISTICS HAT162 controller can detect 2-way voltage (2-way mains, 1-way mains and 1-way gen ) and control ATS. Mains characters are as below, It is suitable for AC system with 3-phase 4-wire, 2-phase 3-wire, single phase, 3-phase 3-wire(special order required); Source 1 Main (auto transfer and restore), Source 2 Main (auto transfer and restore), and No Main Use (auto transfer and non-auto restore) power supply methods; Measuring and displaying 2-way voltage and frequency: 1# 2# Phase voltage (Ua, Ub, Uc) Phase voltage (Ua, Ub, Uc) Line voltage (Uab, Ubc, Uca) Line voltage (Uab, Ubc, Uca) Frequency Hz Frequency Hz With over/under voltage, over/under frequency, loss of phase, and phase rotation detection functions; Breaker close fail alarm indication; LEDs on the panel can clearly display ATS working status; Auto/Manual mode can be switched. In manual mode, ATS can be switched by pressing front panel button; With manual commissioning function; Applicable for 2 isolated neutral line. Close output can be configured as pulse and continuous output; Parameter setting: parts of parameters can be adjust from front panel; all can be adjust via LINK port(with SG72 adaptor) by using computer software; Digitization adjustment of parameters (abandon simulation adjustment of regular potentiometer, and enhanced reliability and stability); Modular design, self extinguishing ABS+PC plastic shell, pluggable terminal, and compact structure; Three installation ways: panel built-in, internal 35mm slideway installation and internal screw mounting. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 4 of 21

3. SPECIFICATION Table 2 Specification Parameters Items Contents Operating Voltage AC power A1N1/A2N2 supply. Rated AC240V (range: AC170V~277V) Power Consumption Under rated voltage, power consumption is not more than 3VA AC Voltage Input: 3-phase 4-wire 2-phase 3-wire Single phase 2-wire 3-phase 3-wire AC170V AC277V (ph-n) AC170V AC277V (ph-n) AC170V AC277V (ph-n) AC170V AC277V (ph-ph) (special order required) AC Frequency 50/60Hz 1# Close Relay 16A AC250V Volt free output (Normally open) 2# Close Relay 16A AC250V Volt free output (Normally open) Oil Engine Start Relay 7A AC250V Volt free output (Normally close) Programmable Output Relay 7A AC250V Volt free output (Normally open) Communication LINK interface, MODBUS-RTU Protocol Case Dimensions 86.9mmx158mmx119.5mm Panel Cutout 73.5mmx144mm Working Conditions Temperature: (-25~+70) C; Relative Humidity: (20~93)%RH Storage Condition Temperature: (-25~+70) C Protection Level IP65: when water-proof gasket installed between control panel and enclosure. Apply AC2.2kV voltage between high voltage terminal and low voltage Insulation Strength terminal; The leakage current is not more than 3mA within 1min. Weight 0.6kg HAT162 ATS Controller 2018-05-10 Version 1.0 Page 5 of 21

4. OPERATION HAT162 ATS CONTROLLER USER MANUAL 4.1 FRONT PANEL DESCRIPTION Fig.1 Front Panel Description 4.2 KEY FUNCTION DESCRIPTION Table 3 Keys Description Icon Function Description Auto (Set) Auto/Manual mode switch; Enter into lamp test status by pressing for 3s; Enter into parameter configuration mode by pressing for 8s. 1# Close (Numerical 1# close in manual mode; increase) Adjust parameters in parameter configuration mode. 2# Close (Numerical 2# close in manual mode; decrease) Adjust parameters in parameter configuration mode. It is active in manual mode; While genset start signal is energizing, press this button can deactivate Test (Confirm) the start genset signal; While genset start signal is inactive, press this button can active the genset start signal; Confirm user defined parameters in parameter setting screen. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 6 of 21

4.3 INDICATOR DESCRIPTION HAT162 ATS CONTROLLER USER MANUAL Table 4 Indicator Description Indicators Description Lamp illuminates: 1# power normal 1# Power Lamp flashes: 1# power abnormal (over/under voltage, over/under frequency, loss of phase, and phase rotation) Lamp off: 1# loss of power Lamp illuminates: 2# power normal 2# Power Lamp flashes: 2# power abnormal (over/under voltage, over/under frequency, loss of phase, and phase rotation) Lamp off: 2# loss of power 1# Main Lamp illuminates: 1# Priority (auto transfer and restore) Both illuminates: mutual backup (auto 2# Main Lamp illuminates: 2# Priority (auto transfer and non-auto restore) transfer and restore) 1# Close Lamp illuminates: 1# Supply 2# Close Lamp illuminates: 2# Supply Alarm Lamp illuminates: 1# or 2# Close fault Auto/Manual Mode Lamp illuminates: controller in Auto mode Lamp off: controller in Manual mode Genset Status Lamp illuminates: genset start signal outputs Lamp flashes: genset start signal de-energized 4.4 OPERATION 4.4.1 AUTO/MANUAL MODE SWITCH When the controller is normally working, if auto/manual mode indicator is off, it means controller is in manual mode; it can switch into auto mode by pressing, the indicator will be normally light; then press again to switch back to manual mode. Note: after repower-on, controller mode depends on the mode in which the controller was last powered down. When the controller is powered off in manual mode, the controller is still in manual mode after repower-on. 4.4.2 MANUAL OPERATION When controller is in manual mode, if press, 1# close relay outputs, and 1# close status indicator illuminated when 1# close status input detecting is active, and then 1# supply ramps on load; if press, 2# close relay outputs, and 2# close status indicator illuminated when 2# close status input detecting is active, and then 2# supply ramps on load. 4.4.3 AUTO OPERATION In auto mode, controller can switch between 1# supply and 2# supply automatically. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 7 of 21

4.4.4 MANUAL TEST HAT162 ATS CONTROLLER USER MANUAL In manual mode, when genset start signal is active, press can deactivate the genset start signal. When genset start signal is inactive, press can active the genset start signal. 5. CLOSE FAULT ALARM Braker close fault devided into 1# supply breaker close fault and 2# supply breaker close fault. After the controller send a breaker close fault alarm, alarm indicator flashes. Process of trigger 1# supply close fault alarm is as below: When 1# supply voltage is normal, controller will initiate an command of close 1# supply; if 1# close input signal cannot be detected, 1# supply will be open and close again. If controller still cannot detect the 1# close signal, it will be regarded as 1# close failure and the alarm indicator illuminates at the same time. Meanwhile, if 2# supply voltage is normal and doesn t occur close fault, then 2# power will be closed. Process of trigger 2# supply close fault alarm is as below: When 2# supply voltage is normal, controller will initiate an command of close 2# supply; if 2# close input signal cannot be detected, 1# supply will be open and close again. If controller still cannot detect the 2# close signal, it will be regarded as 2# close failure and the alarm indicator illuminates at the same time. Meanwhile, if 1# supply voltage is normal and doesn t occur close fault, then 1# power will be closed. Reset close fault alarm: after alarm occurs, switch controller to manual mode to reset alarm. This moment, troubleshooting and ATS transfer test can be carried out. NOTE: after reset alarms, the fault must be checked and cleared. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 8 of 21

6. WIRE CONNECTION HAT162 ATS CONTROLLER USER MANUAL Fig.2 Controller Rear Panel Drawing Table 5 Terminals Description No. Items Function Description Remark 1 N2 Single phase 2-wire: connect with A2 and N2, 2 C2 B2 and C2 are not connected; 3 B2 2-phase 3-wire: connect with A2, B2, and N2, 2# AC 3-phase 4-wire input C2 is not connected; 4 A2 3-phase 3-wire: connect with A2, B2, and C2, N2 is not connected (special order required). 5 N1 Single phase 2-wire: connect with A1 and N1, 6 C1 B1 and C1 are not connected; 7 B1 2-phase 3-wire: connect with A1, B1, and N1, 1# AC 3-phase 4-wire input C1 is not connected; 8 A1 3-phase 3-wire: connect with A1, B1, and C1, N1 is not connected (special order required). 9 Volt free normally open 1# Close Relay 10 contact output Rated capacity: 16A/250VAC 11 12 2# Close Relay 13 Gen Start Volt free normally open Rated capacity: 16A/250VAC contact output Volt free normally close 14 Signal output contact output 15 Volt free normally open Aux. output 16 contact output Rated capacity: 7A/250VAC Rated capacity: 7A/250VAC 17 NC Not connect HAT162 ATS Controller 2018-05-10 Version 1.0 Page 9 of 21

No. Items Function Description Remark 18 1# Close Input 19 2# Close Input 20 Common Port GND LINK Communication Port Detect 1# breaker close status, auxiliary contact input. Detect 2# breaker close status, auxiliary contact input. Communicate with PC and used for program update Ground is active Ground is active Used with SG72 adaptor F1 Fuse Rated 10A 250V F2 Fuse Rated 10A 250V 7. DEFINITION AND RANGE OF PARAMETERS Table 6 Parameters Definition and Range Table (1) No. Items Range Default Description 1 AC System (1-4) 1 1: 3 Phase, 4 Wire (3P4W) 2: Single Phase, 2 Wire (1P2W) 3: 3 Phase, 3 Wire (3P3W) (special order required) 4: 2 Phase, 3 Wire (2P3W) 2 S1 Normal Delay (1-7) 2 1: 1s 2: 5s 3: 10s 4: 20s 5: 30s 6: 45s 7: User defined(default: 5s) 3 S2 Normal Delay (1-7) 2 1: 1s 2: 5s 3: 10s 4: 20s 5: 30s 6: 45s 7: User defined(default: 5s) 4 S1 Abnormal Delay (1-7) 2 1: 1s 2: 5s 3: 10s 4: 20s 5: 30s 6: 45s 7: User defined(default: 5s) 5 S2 Abnormal Delay (1-7) 2 1: 1s 2: 5s 3: 10s 4: 20s 5: 30s 6: 45s 7: User defined(default: 5s) 6 Close Delay (1-7) 4 1: Continuous Close Enabled 2: 1s HAT162 ATS Controller 2018-05-10 Version 1.0 Page 10 of 21

No. Items Range Default Description 3: 3s 4: 5s 5: 8s 6: 10s 7: User defined(default: 5s) 7 Again Open Delay (1-7) 2 1: 1s 2: 3s 3: 5s 4: 8s 5: 10s 6: 15s 7: User defined(default: 3s) 1: 0.5s 2: 1s 8 3: 2s Transfer Delay (1-7) 1 4: 3s Expired 5: 4s 6: 5s 7: User defined(default: 0.5s) 9 Gen Start Delay (1-7) 4 1: 3s 2: 8s 3: 15s 4: 30s 5: 50s 6: 70s 7: User defined(default: 30s) 10 Gen Stop Delay (1-7) 6 1: 3s 2: 8s 3: 15s 4: 30s 5: 50s 6: 70s 7: User defined(default: 90s) 11 Set Priority (1-3) 1 1: S1 Priority 2: S2 Priority 3: No priority NOTE: a) The parameters in this form can be set via computers and slave; b) When delay is 7: User defined, parameter delay must be set via computer. If parameter is not set via computer, the delay is Default; if parameter has been set via computer, then the delay is the set value. Table 7 - Parameters Definition and Range Table (2) No. Item Range Default Description 1 Rated Voltage (170-270)V 230 Provide base for over/under volt judge. 2 Rated Frequency (50.0-60.0)Hz 50.0 Provide base for over/under frequency judge. 3 Over Voltage Warn (0-1) 1 0: Disabled 1: Enabled 4 Over Volt Set Value (100-120)% 115 Threshold value 5 Over Volt Return Value (100-120)% 113 Return value HAT162 ATS Controller 2018-05-10 Version 1.0 Page 11 of 21

No. Item Range Default Description 0: Disabled 6 Under Voltage Warn (0-1) 1 1: Enabled 7 Under Volt Set Value (70-100)% 75 Threshold value 8 Under Volt Return Value 9 Over Frequency Warn (0-1) 1 10 11 12 13 14 Over Frequency Set Value Over Frequency Return Value Under Frequency Warn Under Frequency Set Value Under Frequency Return Value (70-100)% 77 Return value 0: Disabled 1: Enabled (100-120)% 110 Threshold value (100-120)% 104 Return value (0-1) 1 15 Loss of Phase (0-1) 1 16 Phase Sequence Wrong 0: Disabled 1: Enabled (80-100)% 90 Threshold value (80-100)% 96 Return value (0-1) 0 17 Output Ports (0-16) 0 0: Disabled 1: Enabled (fixed delay as 3s) 0: Disabled 1: Enabled (fixed delay as 3s) 0: Not Used 1: S1 Volts Normal 2: S1 Volts Abnormal 3: S2 Volts Normal 4: S2 Volts Abnormal 5: Manual Status Output 6: Auto Status Output 7: Gens Start Output(NO) 8: Gens Start Output(NC) 9: S1 Close Output 10: S2 Close Output 11: S1 Close Status Output 12: S2 Close Status Output 13: Reserved 14: Reserved 15: Reserved 16: Reserved 18 Module Address (1-254) 1 Address that communicates with PC software NOTE: The parameters in this form can be set via computers. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 12 of 21

8. PARAMETERS SETTING 8.1 PARAMETERS SETTING MODE In manual mode, enter into parameters setting mode by pressing for 8s and manual/auto indicator and gen status indicator flash; 1, 2, 3, 4 indicators illuminate. LED numbers please to see the following picture. Fig.3 Parameter Configuration NOTE: At this moment, press will be back to normal mode after LED flash. 8.2 PARAMETERS SETTING When it entered into parameter setting mode, users can adjusting parameters by pressing. And 4 and 7 LEDs are illuminated. 1, 2, 3, 4 indicators mean setting items numbers (currently item number is 1); 5, 6, 7 indicators mean these parameter values (currently parameter value is 1). Configurable parameter list please check Table 6 Parameters Definition and Range Table (1) of item 7. Specific settings are as below: 1) Select setting number which needs to adjust by pressing and ; 2) Enter into setting status by pressing and 7 indicator flashes; 3) After set this parameter by pressing and, and press the key to save the value. 4) Hold and press after all parameters are configured, and release when all LEDs flash, which means parameters are all saved and then will return to normal mode. NOTE: See Table 8 Parameter Value Comparison for the values corresponding of LED indicators. NOTE: after parameters configured completely, users need to press to back to the normal mode to save the parameters. Otherwise, the setting parameters will be lost after controller power outage. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 13 of 21

Table 8 Parameter Value Comparison Parameter Serial No. LED Indicate Parameter Value LED Indicate Value Value 1 2 3 4 5 6 7 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 9 10 11 8.3 RESET TO DEFAULT In parameter setting mode, press, 1, 2 and 3 LEDs illuminated, and 7 LED flashes. After pressing, 7 LED illuminates for 2s, indicating that the factory value has been restored. Meanwhile, all LEDs flash for 3 times and return back to the normal mode. NOTE: if needn t to restore to factory value, press to return to the normal mode after LED flashes. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 14 of 21

9. TYPICAL APPLICATION HAT162 ATS CONTROLLER USER MANUAL Fig.4 SGQ-N Wire Connection HAT162 ATS Controller 2018-05-10 Version 1.0 Page 15 of 21

Fig.5 SGQ-T Wire Connection HAT162 ATS Controller 2018-05-10 Version 1.0 Page 16 of 21

Fig.6 SGQ-M Wire Connection NOTE: Please conference the above drawings for wiring. The actual wiring on site is subject to the ATS switch wiring instructions. And the capacity of the fuse should be selected according to the actual power consumption at the site, which cannot be based on the fuse capacity in the drawing. Fig.7 2 Phase 3 Wire Connection HAT162 ATS Controller 2018-05-10 Version 1.0 Page 17 of 21

Fig.8 Single Phase 2 Wire Connection NOTE: The above drawing shows the wiring method is the AC phase voltage of 220V. If the AC phase voltage is 110V in actual use, please contact our technical personnel to confirm the specific wiring method. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 18 of 21

10. OVERALL DIMENSION AND PANEL CUTOUT 10.1 CASE DIMENSION Unit: mm Fig.9 Overall Dimensions 10.2 CUTOUT The controller has three installation ways: panel built-in, internal 35mm slideway and internal screw mounting. Panel built-in and internal screw mounting are as below: Fig.10 Cutout Dimensions HAT162 ATS Controller 2018-05-10 Version 1.0 Page 19 of 21

10.3 INSTALLATION HAT162 ATS CONTROLLER USER MANUAL Fig. 11 Panel Built-in Installation Fig.12 35mm Sideway Installation Fig.13 Internal Screw Installation HAT162 ATS Controller 2018-05-10 Version 1.0 Page 20 of 21

11. TROBLESHOOTING HAT162 ATS CONTROLLER USER MANUAL Tale 9 - Troubleshooting Symptom Possible Solutions Controller inoperative Check connections and voltages of 1# and 2# power; Check F1 or F2 fuse Controller displays normal but switch not activate Check ATS; Check the connections between controller and ATS. 1# or 2# power LED flashes Check whether AC voltage is normal or not. Alarm LED flashes If switch close failure alarms, please check switch auxiliary contact wiring. HAT162 ATS Controller 2018-05-10 Version 1.0 Page 21 of 21