Analog Input/Output Modules

Similar documents
Sequence CPU - Modbus/TCP Functions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

YHLS Master Module. User s Manual. Applicable Modules: Model Code Model Name F3LH01-1N YHLS Master Module F3LH02-1N YHLS Master Module

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Positioning Modules (with Multi-channel Pulse Output)

User s Manual USB-Serial Converter

WARNINGS. *1 This mark is applicable only in Taiwan.

NX Interface Module. User s Manual. Applicable Modules: Model Code Model Name F3NX01-0N NX Interface Module F3NX01-1N NX Interface Module

RS232C/RS485 Data can be easily monitored by LAN

Tempco Instruction Manual

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

DC I/O Conversion Module FA-TB32XY

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Preface. is the registered trademark of ODVA (Open DeviceNet Vender. Association). *1 Excluding the GP-3200 series.

Preface. The CC-Link unit is compatible with up to CC-Link Ver. 2.0.

User safety and equipment protection guidelines

General Specifications

DC I/O Conversion Module

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

Conductive Level Controller

7032 Digital-Analog Multimeter

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

YHLS Master Module. User s Manual. Applicable Modules: Model Code Model Name F3LH02-0N YHLS Master Module. IM 34M6H46-01E 1st Edition IM 34M6H46-01E

Model VC-SHIELD Shield Box

RТTH DUAL ROOM SWITCH

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Mini Digital Multimeter

Package Contents. GP Options (Made by Digital)

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

V E1B Snap-in I/O Module

P2-04DA Analog Output. Removable Terminal Block Specifications

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Preface. Copyright 2014 Digital Electronics Corporation. All rights reserved.

Communication & Networking

General Specifications. P2-08THM Analog Input

Sequence CPU Instruction Manual - Functions (for F3SP22-0S, F3SP28-3N/3S, F3SP38-6N/6S, F3SP53-4H/4S, F3SP58-6H/6S, F3SP59-7S) IM 34M06P13-01E

Automationdirect.com

Mini Digital Multimeter

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

V E5B Snap-in I/O Module

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

V E2B Snap-in I/O Module

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

PanelView Plus/VersaView CE Terminals and Display Modules

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

User s Manual FA-M3 Programming Tool WideField3 (Introduction and Troubleshooting)

General Specifications. P2-8AD4DA-2 Analog Input/Output

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

P2-04AD Analog Input. Removable Terminal Block Specifications

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

RXTP ROOM TEMPERATURE

UL/c-UL(CSA) Application Notes

PGR-3200 MANUAL INSULATION MONITOR

Safety Relay Unit (I/O Unit Type)

F1000 User's Manual. (Version: V1.01)

Analog Resistive Touchscreen QST Series Product Specifications

EX-RC1 Remote I/O Adapter

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Preface. *1 For the compatible models, please refer to the following. SEE Applicable Products (page 5)

User s Manual Positioning Module (with MECHATROLINK-II Interface)

Ultra Slim Relays 24

EX-RC1 Remote I/O Adapter

V E1B Snap-in I/O Module

RXTH DUAL ROOM SENSOR / SWITCH

The importance of the static electric control is put on confirming the actual status.

PRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition.

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Operating instructions. Switching amplifier DN0210 DN / / 2015

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Thread length (overall length) material

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

V E62B Snap-in I/O Module

About the Manual. ST-3300 Series Installation Guide. Package Contents

VC200 Mobile Phone Tester Please Read before Use

WARNING. To Prevent From Damage:

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

About the Manual. ST-3400 Series Installation Guide. Package Contents

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

HDCVI Compact Mobile Camera User s Manual

PRODUCT SPECIFICATION. PC Board Relays. Series.

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

WARNING 25.2 POWER L.V X1 X2 Y0 C1 Y1 C2 Y2 C3 Y3 ELC-EX NN. 3. Extension unit clip 4. Input/output terminal

NT11S Programmable Terminal

Quick Start Guide. 2MP 4X PTZ IP Camera O2P4X

Extension module for lighting control

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

NT-series Programmable Terminal

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

HD Mini IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.2.0

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Transcription:

User s Manual Analog Input/Output Modules Addendum Manual No. :IM 34M06H11-01E Manual Title :Analog Input/Output Modules Edition :1st Edition With the adoption of the CE Marking conformance declaration for the FA-M3, the following texts are to be inserted or to replace the old descriptions in Analog Input/Output Modules. Page iv and Page v General Requirements for Using the FA-M3 Controller Set the product in a location that fulfills the following requirements: - Where the product will not be exposed to direct sunlight, and where the operating surrounding air temperature is from 0 C to 55 C (32 F to 131 F). There are modules that must be used in an environment where the operating surrounding air temperature is in a range smaller than 0 C to 55 C (32 F to 131 F). Refer to hardware user s manual or the applicable user s manual. In case of attaching such a module, the entire system's operating surrounding air temperature is limited to the module s individual operating surrounding air temperature. - Where the relative humidity is from 10 to 90%. In places where there is a chance of condensation, use a space heater or the like to constantly keep the product warm and prevent condensation. - For use in Pollution Degree 2 Environment. - Where there are no corrosive or flammable gases. - Where the product will not be exposed to mechanical vibration or shock that exceed specifications. - Where there is no chance the product may be exposed to radioactivity. Use the correct types of wire for external wiring: - USE COPPER CONDUCTORS ONLY. - Use conductors with temperature ratings greater than 75 C. Securely tighten screws: - Securely tighten module mounting screws and terminal screws to avoid problems such as faulty operation. - Tighten terminal block screws with the correct tightening torque. Refer to the hardware user s manual or the applicable user s manual for the appropriate tightening torque. Securely lock connecting cables: - Securely lock the connectors of cables, and check them thoroughly before turning on the power. Interlock with emergency-stop circuitry using external relays: - Equipment incorporating the FA-M3 controller must be furnished with emergency-stop circuitry that uses external relays. This circuitry should be set up to interlock correctly with controller status (stop/run). Yokogawa Electric Corporation Feb. 2013 1/9

Ground for low impedance: - For safety reasons, connect the [FG] grounding terminal to a Japanese Industrial Standards (JIS) Class D (earlier called Class 3) Ground *1. For compliance to CE Marking, use braided or other wires that can ensure low impedance even at high frequencies for grounding. *1 Japanese Industrial Standard (JIS) Class D Ground means grounding resistance of 100 Ω max. Configure and route cables with noise control considerations: - Perform installation and wiring that segregates system parts that may likely become noise sources and system parts that are susceptible to noise. Segregation can be achieved by measures such as segregating by distance, installing a filter or segregating the grounding system. Configure for CE Marking Conformance: - For compliance with CE Marking, perform installation and cable routing according to the description on compliance to CE Marking in the Hardware Manual. We recommend that you stock up on maintenance parts: - We recommend that you stock up on maintenance parts, including spare modules, in advance. - Preventive maintenance (replacement of the module) is required for using the module beyond 10 years. Discharge static electricity before touching the system: - Because static charge can accumulate in dry conditions, first touch grounded metal to discharge any static electricity before touching the system. Wipe off dirt with a soft cloth: - Gently wipe off dirt on the product s surfaces with a soft cloth. - If you soak the cloth in water or a neutral detergent, tightly wring it out before wiping the product. Letting water enter the module interior can cause malfunctions. - Do not use volatile solvents such as benzine or paint thinner or chemicals for cleaning, as they may cause deformity, discoloration, or malfunctioning. Avoid storing the FA-M3 controller in places with high temperature or humidity: - Since the CPU module has a built-in battery, avoid storage in places with high temperature or humidity. - Since the service life of the battery is drastically reduced by exposure to high temperatures, take special care (storage surrounding air temperature should be from 20 C to 75 C). - There is a built-in lithium battery in a CPU module which serves as backup power supply for programs, device information and configuration information. The service life of this battery is more than 10 years in standby mode at room temperature. Take note that the service life of the battery may be shortened when installed or stored at locations of extreme low or high temperatures. Therefore, we recommend that modules with built-in batteries be stored at room temperature. Always turn off the power before installing or removing modules: - Failing to turn off the power supply when installing or removing modules, may result in damage. 2/9

Do not touch components in the module: - In some modules you can remove the right-side cover and install ROM packs or change switch settings. While doing this, do not touch any components on the printed-circuit board, otherwise components may be damaged and modules may fail to work. Do not use unused terminals: - Do not connect wires to unused terminals on a terminal block or in a connector. Doing so may adversely affect the functions of the module. Use the following power source: - Use only power supply module F3PU - in FA-M3 Controller for supplying power input for control circuit connection. - If using this product as a UL-approved product, for the external power supply, use a limited voltage / current circuit power source or a Class 2 power source. Refer to the user s manual before connecting wires: - Refer to the hardware user s manual or the applicable user s manual for the external wiring drawing. - Refer to A3.6.5 Connecting Output Devices in the hardware user s manual before connecting the wiring for the output signal. - Refer to A3.5.4 Grounding Procedure in the hardware user s manual for attaching the grounding wiring. 3/9

Pages 2-2,2-8,3-8and 3-14 The following General specification is added. Surrounding air temperature range Operating :0 to 55 C Storage :-20 C to 75 C Surrounding humidity range Operating :10 to 90% RH (non-condensing) Storage :10 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. Pages 2-2 and 2-8 The following Footnote is added. Input signal range *1 0 to 5 VDC (-0.25 to 5.25 V DC) 1 to 5 V DC (-0.25 to 5.25 V DC) -10 to 10 V DC (-11.0 to 11.0 V DC)* *: Accuracy is valid within the input range from -10.5 to 10.5VDC. Pages 2-5 and 2-11 2.1.5 External Connection and Wiring Precautions (1) External Connection Diagram Replace a note in Figure 2.4 External Connection Diagram with the following. - The shielded terminals are connected to the FG terminal of the power supply module through the base module. Pages 2-5, 2-11, 3-6, 3-12 and 3-17 Replace Wire Size and Terminals with the following. Connection Method Terminal block type Applicable conductor 0.33 to 0.82 mm 2 (AWG22 to 18) Shield wire Example: Fuji Cable Industries, Inc. FKEV-SB series Wire temperature rating 75 min. Wire material Copper Wire connection method Crimp-on-type Crimp-on Crimp-on terminals For M3.5 screws terminals Tightening torque 0.8 N m (7.1 lbf in) Applicable crimp-on terminals Example: Japan Solderless Terminal Mfg Co.,Ltd. V1.25-M3 Nihon Tanshi Co.,Ltd. RAV1.25-3.5 4/9

Page 2-6 2.1.5 External Connections and Wiring Precautions (2) Wiring Precautions Replace with the following text. (1) Since analog signals are susceptible to noise, use shielded twisted-pair cables for the connection of the signal source and the F3AD04-0N to shield noise. (2) Ground the shield of the twisted-pair cable to FG using the following methods. - Connect the shield to the SHIELD terminal of the F3AD04-0N. (The SHIELD terminal is connected to the FG terminal of the power supply module through the base module.) IN IN F3AD04-0N Shieled SHIELD (To the FG terminal of the power supply module) - Connect the shield to the SHIELD (FG) terminal provided at the signal source. - R FG F3AD04-0N IN IN SHIELD (To the FG terminal of the power supply module) FG clamp IN IN F3AD04-0N SHIELD (To FG terminal of the power supply module) Screw the clamp to the metal plate of the panel enclosure to ground it. emove the cable cover to expose the wire, ground and secure it using an FG clamp. Whether grounding is performed on the F3AD04-0N or on the signal source depends on the stability of the grounding points. Perform grounding on the point which is more stable. (3) In order to conform equipment incorporating the FA-M3 to the EMC regulations, ground the shield using an FG clamp. 5/9

Page 2-12 2.2.5 External Connections and Wiring Precautions (2) Wiring Precautions Replace notes with the following texts. (a) Since analog signals are susceptible to noise, use shielded twisted-pair cables for the connection of the signal source and the F3AD08-1N to shield noise. (b) Ground the shield to the twisted-pair cable to FG using the following methods. Connect the shield to the SHIELD terminal of the F3AD08-1N. (The SHIELD terminal is connected to the FG terminal of the power supply module through the base module.) F3AD08-1N IN IN AG SHIELD (To the FG terminal of the power supply module) - Connect the shield to the SHIELD (FG) terminal provided at the signal source. F3AD08-1N IN IN FG AG SHIELD (To the FG terminal of the power supply module) - Remove the cable cover to expose the wire, ground and secure it using an FG clamp. FG clamp F3AD08-1N IN IN Shieled AG SHIELD (To the FG terminal of the power supply module Screw the clamp to the metal plate of the panel enclosure to ground it. Whether grounding is performed on the F3AD08-1N or on the signal source depends on the stability of the grounding points. Perform grounding on the point which is more stable. (c) In order to conform equipment incorporating the FA-M3 to the EMC regulations, ground the shield using an FG clamp. 6/9

(d) When connecting signals whose common mode voltage does not overlap the common mode voltage reference (using the electric potentials of the signals connected to the AG terminals as reference) and floating signals with ungrounded (-) terminals, connect the (-) terminal of each input signal to the AG terminal of the F3AD08-1N. 1 G 2 G 3 F3AD08-1N IN1 IN1 IN2 IN2 IN8 IN8 Standard common-mode voltage SHIELD AG ±0V (in floating status) (*) The signal source in a floating state can operate even without connecting the negative input line to the AG terminal of F3AD08-1N. However, if the negative line is connected to the AG terminal, the module's signal-reading ability will increase. (*) Pages 3-2 3.1 F3DA02-0N Module 3.1.1 Functional Table 3.1 Functional Permissible load resistance Voltage output mode : 5 kω min. : 0.3μF max. *2 Current output mode : 600 Ω max. : 1mH max. electropneumatic converter PK5502 or equivalent *2 *2:This value is tested by evaluation but is not a guaranteed value. Pages 3-6, 3-12 and 3-17 External Connections and Wiring Precautions (1) External Connection Diagram The following warning is added. Warning Output from the OUT ± terminal is not allowed if the external power supply is not turned on. 7/9

Pages 3-7, 3-13 and 3-18 (2) Wiring Precautions The description is replaced with the following text. (1) Since analog signals are susceptible to noise, use shielded twisted-pair cables for the connection of the signal source and the F3DA02-0N to shield noise. (2) Ground the shield to the twisted-pair cable to FG using the following methods. - Connect the shield wire to the shield (FG) terminal provided at the signal source. Destination equipment F3DA02-0N OUT OUT FG Remove the cable cover to expose the shield, ground and secure it using an FG clamp. Destination equipment - FG clamp F3DA02-0N OUT OUT Screw the clamp to the metal plate of the panel enclosure to ground it. Whether grounding is performed on the F3DA02-0N or on the signal source depends on the stability of the grounding points. Perform grounding on the point which is more stable. Page 3-8 3.2 F3DA04-1N Module The following General specification is added. Surrounding air temperature range Operating:0 to 55 C Surrounding air temperature C 周囲温度 60 50 40 30 20 10 0 0 100 200 300 400 500 600 700 800 Current output 電流出力負荷 and load resistance Ω Ω Storage :-20 C to 75 C Surrounding humidity range Operating:10 to 90% RH (non-condensing) Storage :10 to 90% RH (non-condensing) Surrounding atmosphere Must be free of corrosive gases, flammable gases or heavy dust. : The high limit of the operating temperature range is 50 C if 4channels are used with current output and load resistance not exceeding 100 Ω 8/9

3.2.1 Functional Table 3.4 Functional Permissible load resistance Voltage output mode : 5 kω min. : 0.3μF max. *2 Current output mode : 600 Ω max. : 1mH max. electropneumatic converter PK5502 or equivalent *2 *2:This value is tested by evaluation but is not a guaranteed value. Page 3-14 3.3 F3DA08-5N Module 3.3.1 Functional Table 3.7 Functional Permissible load resistance 5 kω min. 0.3μF max. *4 External power supply *2 Absolute maximum rated voltage : 30 V DC Operating power limits : 24 V DC ±10%, 100 ma *4:This value is tested by evaluation but is not a guaranteed value. 9/9