HVAC unit. Spacerfor. ILL. 3 1" filter. Screw

Similar documents
ECONOMIZERS. Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH UNITS CAUTION WARNING

Downflow Economizers Z1ECON30 (98W09) ECONOMIZERS

IN STAL LA TION IN STRUC TION

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners

INSTALLATION INSTRUCTIONS ECOHPRS Series Horizontal Economizer for York PRESTIGE for ZX 04-07; ZY 04-06

INSTALLER'S GUIDE ECON-IN-30B 18-HE60D83-3. Accessory Economizer Downflow

Economizer Control 2-1

Installation Instructions

READ COMPLETELY BEFORE INSTALLING!!!

MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT

Installation Instructions

MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Installation Instructions

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

INSTALLATION INSTRUCTIONS

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

THERMOSTATS & CONTROLLERS

Fast Route to Reliable Energy Savings ZIP Economizer

INSTALLATION MANUAL FOR CARRIER/BRYANT 3-15 TON ECONOMIZERS 3-6 TON MODELS

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Overview of types. Technical data

ASI Systems ML5740A Series

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

SE7600E Series Application Guide

Specification and Design Catalog. Waterside Economizer

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

Rack Installation Instructions

Table I - Package Contents. Table 2 - Filter Sizes. Read these instructions completely before attempting to install the Vertical Economizer Accessory

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features

DCG Commercial. Submittal Data Form

M1000 INTELLIGENT ZONE CONTROL SYSTEM

ASI Systems ML5720A Series

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

CDD4 Duct Carbon Dioxide Transmitter

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Rack Installation Instructions

BB5-Lite TECHNICAL MANUAL

CONTROLLER INSTALLATION OPERATION & QUICK START

System Storage EXP3000 Rack Installation Instructions

INSTALLATION INSTRUCTIONS ECOHAFF1860 Series Horizontal Economizer for York Affinity 3-5 Ton Units. Before Starting Installation Warning

Rack Installation Instructions

Application Engineering

ECON-ZIP-BASE. ZIP Economizer Base Module

TF243 Series Digital Thermostat Fan Coil Unit Control

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

[GSE25SETACSS] FREEZER DOOR

InView Marquee Message Display

IBM. Rack Installation Instructions

ETM-2040 Service Manual

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

TC-9102 Terminal Controller

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

BA/BS4S Temperature Sensor Installation & Operating Instructions

SK Installation Instructions

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

TOXALERT MODEL AIR 2000

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

Screw. Nut Guide. Features

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Service Parts Manual Under Counter (UC-24) Series

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

FFHS2622MBQA FFHS2622MSYA FFHS2622MWNA

Installation, Start-up and Operating Instructions

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Rack Installation Instructions

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

PowerView Model PV350 and PV380. Installation Manual Section 78

Installation and Maintenance Manual IM

120 VAC 14x12x7 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fan and Solid State Fan Controller Model: NB FS

OPERATION INSTRUCTIONS

Megatouch FORCE Monitor Chassis Board Replacement

Installing Power Modules

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

SE7600E Series. Installation Guide for Commerical HVAC Applications CONTENTS

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

SE7600E Series Application Guide

Contents. Cabinet Components " Exploded View... 1 " Usage List U.S. Models... 2 " Usage List Canadian Models... 3 " Blank Page...

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

INSTALLATION & OPERATING INSTRUCTIONS. ECONOMIZERS WITH EXHAUST for EQUIPMENT BUILDING APPLICATIONS

ETM-2050/ETM-2051 Service Manual

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintage A. TYA, TAA No Vintage. Last Manufactured: 1993

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

Functional data Factory settings Variable Setting Torque Inhibiting torque

Field selectable application type and room module series, via dip-switches on controller

FSC23R5DB0 FSC23R5DB1 FSC23R5DW0 FSC23R5DW1

INSTALLATION INSTRUCTIONS

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

Smart Equipment Controls (SEC)

INSTALLATION & OPERATING INSTRUCTIONS. ECONOMIZERS WITH EXHAUST for STANDARD APPLICATIONS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Transcription:

MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully before beginning installation For Down Discharge ILL. 1 (for Horizontal Application go to page 4) Compressor Compartment 1. Remove the side panel from the HVAC unit, ILL 1. Discard panel. 2. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to coil frame through pre-punched hole. Maximum screw length 1/2". 3. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to coil frame. Maximum screw length 1/2". Blank-off should fit between top and bottom racks to the far left of HVAC unit. (If using 1" filters, spacer may need to be removed to position blank-off. Once blank-off is in position, re-install spacer.) Side Panel with HVAC unit. Remove and discard Rack Blank-off ILL. 2 Detail _ jtop filter Evaporator 4. If using 2" wide filter remove spacer. ILL. 3. 5. To change filter: Open hinged door. Remove middle filter first. Slide remaining filters to middle of rack for removal. To install filters, reverse above operation. HVAC unit screw BoSom filter/- Spacerfor #" ILL. 3 1" filter (3) 12" X 24" X 1" Bo_o Screw 2" filter (3) 12" X 24" X 2" Manufacturer reserves the right to disconljnue,or change at any IJrne,specificaf_ns, designs and pnces without no'dceand without incurnngobliga_ons. Form No. IlK 582A-42-1 / 48/50-10381 Catalog No. 534-80093 Copyright MicroMetl Corporation 2001. All fights reserved.

ILL.5 Install additional screw 'l unit flange into replacement panel. Replacement Shipped with economizer panel. Install 3/4" x 1/8" gasket along flange 3/8" " -. I 1/2" flange MicroMetl Install 3/4" x 1/8 28 _/2" economizer bottom gasket along Economizer cover panel 5. Install the replacement panel (shipped with the economizer) over the compressor compartment of the HVAC unit. Screw in place through the prepunched holes. 6. Slide the economizer into the return air chamber, ILL. 5. Slide the economizer as far to the left as possible. The economizer's right side will slightly overlap the bottom filter rack. Be sure economizer is flat. 7. Install gasket and the economizer cover panel over the economizer. Screw in place to the divider in the HVAC unit, base and top. Also, align economizers 3/8" flange to the outside of 1/2" flange as shown and secure economizer cover panel to economizer using provided pre-punched holes with 1" long tek screw. 8. Run the _economizer wiring harness through the grommet in the economizer side and through the HVAC units provided hole located in the upper part of the HVAC unit divider. (Install provided grommet in divider hole.) Follow the enclosed harness routing diagram. (see page 8) 2

g, Screw the rainhood to the economizer panel through prepunched holes. Caulk hood perimeter. (After adjusting the minimum position setting on the actuator, install the 24 3/8" x 19 3/8" aluminum filter in the rain hood.) 11. Remove cover panel shipped over the horizontal return opening. Locate the filter access panel and gasket mating flanges. Install door latch angle, Screw the hinge to the HVAC unit over the horizontal return opening. Adjust the closure handles for a tight seal. 12, Install the provided filter access sticker on the hinged door. kluminum water entrainment filter Horizontal supply A ILL. 7 air cover panel. /" _ - HVAC_ SIDE VIEW Down Discharge Replacement Door latch angle 13. Be sure the seams are all water tight. Seal as required. Filter access door - hinged Install filter access door sticker Aluminum Filter 14. Follow the wiring instructions enclosed. (see page 7) TOP VIEW ILL. 8 Screw panel Compressor Door angle DOOR LATCH ANGLE DETAIL Hinge Economizer Hood [] \ Replacement Panel 3

l-or I-IOrlzonl:al Ulscnarg_e_ (for Down Discharge Application go to page 1) 1. Remove the side panel from the HVAC unit, ILL. 1, discard the panel. Compressor Compartment 2. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to coil frame through pre-punched hole. Maximum screw length 1/2". 3. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to coil frame. Maximum screw length 1/2". Blank-off should fit between top and bottom racks to the far left of HVAC unit. (If using 1" filters, spacer may need to be removed to position blank-off. Once blank-off is in position, re-install spacer.) Side Panel shipped with HVAC unit, Remove and discard 4. If using 2" wide filter remove spacer. ILL. 3. 5. To change filter: Remove filter access door on economizer cover panel. Remove middle filter first. Slide remaining filters to middle of rack for removal. To install filters, reverse above operation. Blank-off \.. Top filter "/ /'-_--_ ""->_ rack Evaporator HVAC unit s( _ws Bo_orn filter/- -_--_,..-_q_ Spacerfor Rack ILL. 2 Detail #" ILL. 3 Filter Wiath 1" filter (3) 12" X 24" X 1" BoSom 2" filter (3) 12" X 24" X 2" 4

ILL. 6 Replacement panel with economizer Install additional screw unit flange into replacement panel. ; unit 9,, Install 3/4" x 1/8" asket along HVAC divider flange. Economizer panel Install 3/4" x 1/8" gasket HVAC bottom 3/4" x 5/8" 7. /16 Filter access door Casketing, 3 Sides. blank-off Caulk these corners after economizer is installed Screw nto base Remove molded gasket from economizer for _ 28 1/2" horizontal application. 6. Install the replacement panel over the compressor compartment. Screw in place through the prepunched holes. 7. Install provided economizer blank-offto bottom of economizer. Screw in place through the prepunched holes. 8. Install the 3/4 x 5/8" gasketing on the bottom flanges of the economizer, ILL. 6. 9. Turn the economizer on its side as shown, ILL. 6. Slide the economizer into the cabinet and as far to the left as possible. The economizer will set against the left side of the HVAC unit. Caulk as required. 10. Install the economizer cover panel over the opening and economizer. 11. Align the economizer to the cover panel with 1" long tek screw using the provided pre-punched holes. NOTE: The relief damper must be sealed shut for the horizontal discharge application. 5

HVAC Unit ILL. 7 Replacement with panel economizer Filter access door for Lpplieation Install filter access door sticker. Rainhood with water entrainment filter 11. Route the economizer wiring harness through the grommet in the economizer side and through the HVAC unit's provided hole located in the upper part of the HVAC unit divider. (Intall provided grommet in divider hole.) Followthe harness routing diagram. (see page 8) i The side hinged panel and i horizontal cover panel will not be used in the horizontal i applicationl, 12. Screw the rainhood to the economizer panel through the prepunched holes. Caulk hood perimeter. An extended socket will be required for the left side of the hood. After adjusting the minimum position setting on the actuator, install the aluminum filter in the rainhood. Install the provided filter access sticker on the horizontal filter door. 13. Follow _he wiring instructions, see page 7. 6

DischargeA _Gra Equipment Transformer Yellow Main24V Splice Box Sensor Orange Green _] J[ Dry Bulb outside air sensor (or optional enthalpy) Brown 0 Green _. Gr_..Lr White [ NOTES: /'_ OPTIONAL LOW AMBIENT CONTROL //_ TRANSFORMER IN HVAC UNIT. Red Z_ POWER SUPPLY. DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.... i t... 1 I t I t z_ MUST BE INSTALLED ON SUPPLY AIR FAN. 3000 OHM AT 25 C, 77 F /.k REMOVE JUMPER WHEN OPTIONAL REMOTE POTENTIOMETER IS USED z_is POWERED IS AN ELECTRONIC BY A 24 VAC SWITCH INPUT. WHICH CLOSES WHEN Z_ RELAY 1K & 2K ACTUATE WHEN THE OUTSIDE AIR SENSED BY THE ENTHALPY OR DRY BULB IS LOWER THAN THE SET POINT A-D. Z_ FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD BE REMOVED ONLY IF A SENSOR IS ADDED TO SR AND + FOR DIFFERENTIAL CHANGEOVER. /_ RESISTER ONLY REQUIRED FOR FIXED DRY BULB. ' OplJonalRemote Poteni]ometer Form No. IlK 582A-42-1 / 48/50-103SI Catalog No. 534-80093

n, _Gray Sensor Equipment Transformer Main 24V,YEtLOW [ IT, AC FUAIOR Ax D_ Bulb Outside Air Sensor (or optional enthalpy) III IZI : I I I GO NOTES: Z_ OPTIONAL LOW AMBIENT CONTROL. n. ',',,,,', Ill,, I I I m _ il I I I I J t U II i I LJL_ II I,, _._Z! Im ',k...,,,,,,:, ;; (_ Terminals WIRING LEGEND EQUIPMENTTRANSFORMERMUSTBESIZEDTOACCOMMO- Wire nut or equivalent connection I z_ DATE AN ADDITIONAL 12VA. IF NOT, AN ADDITIONAL iii l 4% ] I OPTIONALTRANSFORMERISREQUIRED. lli I I MMC wiring harness 1,I ', I, 1 _ Op'donal Remote Z_ PROTECTION POWER SUPPLY. AS REQUIRED. DISCONNECT MEANS AND OVERLOAD ii tl Ii '1[ ;... _ Poten_neler -- Field supplied low voltage wire Z_ MUST BE INSTALLED IN SUPPLY AIR STREAM. 3000 OHMS i I Ill L e-... -I I [ L--Field supplied high voltage wire AT 25_C, 77eF Z_ REMOVE JUMPER WHEN OPTIONAL REMOTE POTENTIOM- ETER IS USED lel... q _ i I I I L... 1 I I I I --Other low voltage wire I L---I I I I I I /_ ls IS ANELECTRONIC SWITCH WHICH CLOSES WHEN POWERED BY A 24 VAC INPUT. //_ RELAY 1K & 2K ACTUATE WHEN THE OUTSIDE AIR SENSED BY THE ENTHALPY OR DRY BULB IS LOWER THAN THE SET POINT A-D. FACTORY INSTALLED 620 OHM. 1 WATF, 5% RESISTOR,_ SHOULD BE REMOVED ONLY IF AN ENTHALPY OR ADJUST- ABLE DRY BULB SENSOR IS ADDED TO SR AND + FOR _ DIFFERENTIAL RESISTOR ONLY REQUIRED FOR FIXED DRY BULB. R1 - RELAY IS FIELD SUPPLIED AND FIELD INSTALLED. MOUNT RELAY IN CONTROL BOX, ABOVE INDOOR FAN RELAY THERMOSTAT I shock or equipment damage Form No. IlK.n_.A-42-1 / 48/50-103SI Catalog No. 534-80093

Routing Wiring Harness Economizer A _'-'--'3 Supply fan/ Main 24V splice box Discharge sensor. Field To.._op_ View Wiring harness. Factory attached to economnzer actuator. Factory run to splice box. ACCESSORY SLIDE-IN ECONOMIZER CONTROL INSTALLATION, 1. Unpackage economizer, 2. Install accessory in unit per installation instructions provided. 3. Remove parts bag and instructions from inside of accessory. 4, Install the discharge sensor in the supply fan section. The sensor must protrude into the supply air stream. Damper Dart module Economizer rainhoed EconOmizer rainhood i "q--'--'j A Economizer Water entrainment filter in hood enthalpy (optional) or Economizer harness actuator Replacement with econo- shipped mizer panel Main 24V =lice box 5, Uncoil the wiring harness. Connect the two gray wires of the harness to the discharge sensor leads using the two wire nuts provided. 6. Route the remainder of the wire harness through the unit to the main 24V splice box. 7. Mount thermostat downstairs per the manufacturer's instructions. Run proper wire from the thermostat to the unit control panel. 8, Review the MicroMetl wiring diagram from this booklet. Connect unit, wire from the thermostat and harness from the economizer, together to match the diagram. harness 9, 10. Follow start-up instructions Adjust change over setpoint on logic module. below. Damper actuator and dry bulb or enthalpy Compressor "A-A"SideView Discharge sensor. Field install. 11. Adjust minimum position set point on logic module. d [.:'] 1. After unit is wired begin start-up procedures. 2. Set thermostat functions to OFF. Set comfort levels to minimum cool and minimum heat. 3. Turn unit power on following manufacturer's start up instructions. 4. Turn thermostat fan function to ON. Unit indoor blower should start and damper motor will drive to minimum vent position. Minimum vent position should be adjusted on the economizer logic for the proper percentage of outdoor air. * 5. Switch the thermostat function from OFF to HEAT or AUTO. Bring the comfort setpoint for heat up to engage first stage heating. Follow manufacturer's procedures to check heating cycle. Bring the comfort setpoint for heat up to engage second stage heating if available. Check this heating cycle also. 6. Under no circumstance should the economizer operate in a heating mode except for minium vent position. g 7. Change the thermostat function from HEAT to COOL or leave in AUTO. Drop the comfort setpoint down to engage first stage call for cooling. The first stage cooling call travels to the economizer. If the outdoor air is above the A through D setpoint, (see chart on next page), the first stage mechanical cooling is brought on. As the comfort setpoint is reduced more there will be a second call for cooling which will bring on second stage mechanical cooling if available. 8. In the cooling mode if the outdoor air is below the satpoint, the first stage call for cooling will open the economizer. As the comfort setpoint is reduced more there will be a second call for cooling. This call will bdng on the first stage mechanical cooling to back up the economizer. 9. Once all stages have been cycled, and all adjustments made return thermostat to its proper operating mode, replace all doors, panels and hoods. 10. Leave a copy of these instructions with the customer.

These instructions are for fully modulating electronically controlled economizers utilizing solid state logic throughout. A standard single or (recommended) two stage thermostat is all that is needed to complete the control and economizer system for the HVAC equipment. 1. 2. 3. 4. Damper actuator.., 9901-0083 provides 24v modulating control of economizer dampers, 25 in. lb. of torque. (Honeywell M7415A-1006) Ball joint for linkage connection. Discharge sensor... 9901-0001 provides a signal (3000 Ohms at 25 C or 77 F) to the actuator during free cooling or economizer mode. The signal opens the economizer damper until the discharge temperature drops below 55. At this time the signal causes the motor to modulate the damper and mix outside air with return air to maintain a 50 R to 56 R discharge temperature. Wire nuts to connect discharge sensor to the harness. 6. Dry bulb...9901-0183 senses temperature of outside air and provides signal to the economizer logic. Opens outside air at 60, closes outside air at 70 (enthalpy optional). 7. 5/8" grommet fits 5/8" hole that wires may pass through to keep from chaffing. 8. Wire clamps to secure wires to base, dividers, etc.. 9. Wire harness color coded and pre-wired to actuator and economizer logic... 9962-0087. 10. 1/2" hex head screws to secure wire clamps. 5. Economizer logic... 9901-0017 accepts input from discharge _ensor and outside air sensor. Analyzes input to control actuator modulation and economizer switching. Logic also houses minimum position adjustment and enthalpy or adjustable dry bulb adjustment. When used with optional differential sensors in the return air, the logic is capable of selecting the most economical air available for cooling. (Honeywell W7459A-1001) 10

The purpose of an economizer is to use outdoor air for cooling, whenever possible, to reduce compressor operation. The economizer system initially responds to a signal from the cooling thermostat and functions as a true first stage for cooling, while providing maximum fuel economy. The economizer is automatically locked out during the heating mode and holds the outdoor air damper at the minimum position settings. During the occupied period, on a call for cooling, when outdoor air temperature or enthalpy (optional) conditions are low, the economizer actuator will proportion to maintain between 50 -F and 56-oF at thermistor discharge sensor. If the mixed or discharge temperature is above 56 - F, actuator will open to admit additional outdoor air until the temperature returns to the 50 -to 56- F range. If the mixed or discharge air temperature is below 50_ F, the actuator will proportion closed, shutting the outdoor air damper until the temperature returns to the 50 -oto 56-oF range. During the occupied period, the actuator will not close past the minimum position. If the fully open actuator cannot satisfy the space demand, mechanical cooling is sequenced on. During the unoccupied period, the actuator will override minimum position setting and drive fully closed. On a loss of power, the actuator will spring return fully closed. When in heating operation, or when outdoor air temperature or enthalpy (optional) conditions are high, economizer operation is locked out, and actuator is held at minimum position. The staging relay is used when the first stage compressors must provide mechanical cooling when assisting the economizer. The staging relay can be omitted when the second stage compressors can be used to assist the economizer with mechanical cooling. tt

Lvli_ It it It, ii "..-V_L='_((*},Ir " ';i_71_jf,, [_, [ The minimum position potentiometer keeps the outdoor air 2. If remote control of dampers is desired, connect the damper from closing completely during system operation remote potentiometer to P and P and turn it fully to provide ventilation, clockwise before adjusting the minimum position. 1. Make sure the factory installed jumper is in place across terminals P and P_. 3. Connect 24V AC to system and adjust the potentiometer on the face of the logic module with a screwdriver for desired minimum position. Single enthalpy: The enthalpy changeover setpoints is set to return the outdoor air damper to minimum position when the enthalpy rises above its set point. The enthalpy setpoint scale markings, located on W7459 are A,B,C,D as shown below. The factory-installed 620-ohm lumper must be in place across terminals + and S,_ unless using differential enthalpy. 10 5O 20- W ---_13 I-uJ <; d0- uj:e _O 40- zo: :_ow _t)> wo 5o- XQ_O _,,0,< 60- Q:.q 70- wi D 80 lid IC. IA EXAMPLE FOR DETERMINING ENTHALPY CONTROL SETTING (1008-0100) e0 ::..i_ O> i 0::0 w aw(.9 T :EwZ : _,_ : :_Wz ' _-o - 80W (j ' LII _,1 i I]'il I [;]il ir_l I[i.] i_1 i[. [_._,_;] dl.."._[_ i,[. 1_ 'i[.] i f; i i i Differential enthalpy control (optional) utilizes two enthalpy sensors connected to one W7459 Economizer Control. The enthalpy setpoint scale markings, located on the W7459, are A,B,C,D. Turn the setpoint potentiometer fully clockwise past the D setting. The economizer will select the air with lower enthalpy for cooling; i.e., if outdoor air has lower enthalpy than return air, then the outdoor air damper will be opened to bring in outdoor air for free cooling. The differential enthalpy connects to S_ and + on the W7959 logic. Note: The C7650A adjustable dry bulb can also be used for differential change over. Only the temperature of the outdoor air and return air will be compared and the best selected for free M _ cooling. MlcroMeU Call Toll-Free: 1-800-662-4822 Fax: 1-317-543-5986 icrometlwest Call Toll-Free: 1-800-884-4662 Fax: 1-775-356-9184.% _L''- W7459 Logic Module Enthalpy Changeover Set Point._.iMinimum Damper Position Setting.._p...--.--LEDLights up to indicate Outdoor Air is Suitable for Free Cooling Manufac_rer reservesthe rightto discontinue,or change at any time, specifications,designsand priceswithoutno'_ceand withoutincurnngobligations. Copyhght MicroMetl Corporation 2001. All rights reserved. 12

SUBMITTED TO COMPANY: DRAWN BY: M. HARGIS JOB NAME: EQUIPMENT: NOTES: Features: Economizer can be used in a down or horizontal application. Fully assembled, easy to install in both down and horizontal application. Modulating control system factory installed and wired (optional). Rainhood ships assembled, includes a water entrainment filter and is constructed of prepaint steel. Low leak outside air damper. Barometric relief damper (for down discharge only). Insulated filler access door is hinged and latched. Includes filter rack and (3) 12" x 24" x 1"filters. Supply air cover panel shipped on HVAC unit. Carrier Unit No. Economizer P.N. Carrier P,N. 48/50GS 50JS 048-060 0637-0211 48/50GX. 50GL 48GP 042-060 (NOTE 1) CPECOMZR004A00 50JX, JZ 042-048 50JX, JZ 060 0637-0311 CPECOMZR006A00 NOTE: 1. DPDT relay (HN61KK040) for heat pump application is field provided on the 0637-0211. Replacement panel shipped with economizer SIDE VIEW Down Discharge Filters Hinged latched door for down discharge filter access " with outside air Economizer's barometnc "-... water entrainment damper relief damper _,. filter (For down discharge only) Aluminum entrainment filter water THIS OOCUMENT IS THE PROPERTY OF MICROM ETL CORPORATION AND IS DELIVER ED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED O R US ED WITHOUT MICROMETL'S WRI_ EN CONSENT MICROMETLCORPORATION*3035N SHADELANDAVENUE,SUITE300 INOIANAPOLIS, IN 46226*l-800-662-4822_MICROMETLWES T 202SOUTH 18THS- SPARKS,NV 89431 ol 800-884-466E