Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

Similar documents
02/11/2015

Zelio Control-modular measurement and control relays 1

Zelio Control Measurement Relays Multifunction 3-phase supply control relays RM17T 00

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM35TF V AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RM17UB3. Price* : USD

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

02/11/2015

02/11/2015

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

08/07/2015

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

Contact protection relay

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

Electronic timer CT-ERS.21

RM4JA01F current measurement relay RM4-J - range ma V AC

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

RM4TR31 three-phase network control relay RM4-T - range V

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

em4 Accessories Digital expansions

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RE9RA21MW7 off-delay timing relay s V AC -

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

SR2B201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

SR3B102BD modular smart relay Zelio Logic - 10 I O - 24 V DC - clock - display

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

RM4UA33M voltage measurement relay RM4-U - range V V AC

SR2A201BD. Main. <= 0.5 ma for IB...IG used as discrete input circuit. <= 5 Vfor IB...IG used as discrete input circuit V

ZBRN1. Main. Device short name

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

TeSys protection components

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

TeSys IEC Contactors and Overload Relays

SR2B121FU. Price* : USD with ladder programming. 80 maat 100 V (without extension)

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Zelio Control Measurement Relays RM4 and RM84

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

PHOENIX CONTACT Features

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

SR2D101BD compact smart relay Zelio Logic - 10 I O - 24 V DC - no clock - no display

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

RM4TA32 three-phase network control relay RM4-T - range V

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Electronic timer CT-ARS.11

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RM4JA31M current measurement relay RM4-J - range ma V AC

Electronic timer CT-ERD.12

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

02/11/2015

Operating instructions. Speed monitor D / / 2014

Transcription:

Presentation, description 1 Speed control relays M35 S 105687 Presentation Speed control relay M35 S0MW monitors: 2 Underspeed: without memory, with memory, 5 with inhibition by external contact. 2 Overspeed: without memory, with memory, 5 with inhibition by external contact. M35 S0MW Speed control relay M35 S0MW measures via: A 3-wire PNP or NPN proximity sensor input, A Namur proximity sensor input, A 0-30 voltage input, 2 A volt-free contact input. It operates with either N/O or N/C sensors. The adjustable time between impulses is 0.05 s 10 min. The power-on inhibition time is adjustable from 0.6 to 60 s. hibition is controlled by an external contact. Settings are protected by a sealable cover. Control status is indicated by a LED. The relay is designed for clip-on mounting on 4 rail Applications 2 Monitors speed or rate of rotary or linear movements in the following applications: conveyors/conveyor belts, packaging, 5 mechanical handling. Description M35 S00MW Y1 E1 E2 0 Un 11 1 2 3 4 5 1 Configuration: selection of operating mode: Underspeed or overspeed. Underspeed/Overspeed with or without memory. Memory - No Memory 2 Speed threshold setting potentiometer. alue 3 Speed range selector switch 4 Starting inhibition time delay adjustment potentiometer. 5 Spring for clip-on mounting on 35 mm 4 rail. Un Yellow LED: indicates inhibition status (time-delay or input). Green LED: indicates that supply to the relay is on. Yellow LED: indicates relay output state. 74 eferences, dimensions :

Operation 1 Speed control relays M35 S Operating principle elay M35 S0MW monitors the speed (rate, frequency) of a process (conveyor, conveyor belt, etc.) via discrete sensors: 3-wire PNP or NPN proximity sensor, or 0-30 voltage input, or NAMU proximity sensor, or volt-free contact. It can be used for monitoring underspeed or overspeed. Speed control relay: M35 S0MW 2 Measurement The cycle of the process being monitored is the series of impulses characterised by a two-state signal: high and low. The speed measurement is obtained by measuring the period of this signal, from the first change of state detected (either rising or falling edge). Digital processing of the signal allows the disparity between the signals to be calculated. At power up, or after appearance (or reappearance) of the sensor signal, detection (characterisation) of the signal requires processing of one or more periods (maximum of two). During this time, control is inoperative. 2 Operating mode Using the switch, select one of the four operating modes: Underspeed without memory, Underspeed with memory, Overspeed without memory, 5 Overspeed with memory. Function diagrams 2 Underspeed control 2 Function: Underspeed control - Underspeed At the end of the starting inhibition time delay "", as soon as the speed measured 5 Without memory - No Memory drops below the threshold setting, the output relay changes state from "closed" to 1 sec mini "open". It returns to its initial state when the speed is again higher than the threshold plus hysteresis (fixed at 5% of the threshold setting). When power is restored, after a break having lasted at least 1 s, the relay is in the on ("normal") state during the time delay and stays in that state for as long as the speed remains higher than the threshold. elays 11-/11-5 With memory Memory When relay M35 S has been configured in "memory" mode, if underspeed is 1 sec mini detected, the output relay stays in the off ("alarm") state whatever the further evolution of the process speed. 50 ms mini It will not be able to return to the on ("normal") state until contact closes (for at least 50 ms). If, when re-opens, the speed is not high enough, the relay returns to the locked, off ("alarm") state. elay M35 S can also be reset by a power break (at least 1 s); the relay then returns to the on ("normal") state for at least the duration of the time delay, whatever the process speed. elays 11-/11-5 With inhibition by - hib./ At power up, in order to allow the process being monitored to reach its nominal operating speed, relay M35 S is inhibited for a time delay adjustable from 0.6 60 s. This time delay can be adjusted (shortened or lengthened) during inhibition. elay M35 S can also be inhibited by closing of contact : on starting, for example, if the process run up to speed time is greater than 60 s, or at any time during operation. elays 11-/11- Whether it results from a starting inhibition time delay or closing of, inhibition keeps the output relay in the "closed" position and is signalled by illumination of the inhibition LED. If, after lifting of inhibition (end of starting inhibition time delay or opening of contact ), the signal detection phase has not been completed, the relay drops out after the set wait time between two impulses (measured as from the end of inhibition). hibition must last as long as is necessary for the product to detect at least 2 periods. When the signal has not been 'characterised' by the end of the inhibition period, the "inhibition" LED flashes for as long as speed measurement is impossible. It is also possible to inhibit relay M35 S at any time, during operation, by closing. eferences, dimensions : 75

Operation (continued) 1 Speed control relays M35 S Speed control relay: M35 S0MW (continued) Function diagrams 2 Overspeed control 2 Function: overspeed control - Overspeed 5 Without memory- No Memory At the end of the starting inhibition time delay, "", as soon as the speed measured 1 sec mini is higher than the threshold setting, the output relay changes state from "closed" to "open". It returns to its initial state when the speed is again lower than the threshold minus hysteresis (fixed at 5% of the threshold setting). When power is restored to relay M35 S, after a break having lasted at least 1 s, the relay is in the on ("normal") state during the time delay and stays in that state for as long as the speed remains lower than the threshold. elays 11-/11-5 With memory - Memory 1 sec mini When relay M35 S has been configured in "memory" mode, if overspeed is detected, the output relay stays in the off ("alarm") state whatever the further 50 ms mini evolution of the process speed. It will not be able to return to the on ("normal") state until contact closes (for at least 50 ms). If, when re-opens, the speed is too high, the relay returns to the locked off ("alarm") state. elay M35 S can also be reset by a power break (at least 1 s); the relay then returns to the on ("normal") state for at least the duration of the time delay, whatever the process speed. elays 11-/11-5 With inhibition by. - hib./ At power up, in order to allow the process being monitored to reach its nominal operating speed, relay M35 S is inhibited for a time delay adjustable from 0.6 60 s. This time delay can be modified (shortened or lengthened) during inhibition. elay M35 S can also be inhibited by closing of contact : on starting, for example, if the process run up to speed time is greater than 60 s, or at any time during operation. Whether it results from a starting inhibition time delay or closing of, inhibition elays keeps the output relay in the "closed" position and is signalled by illumination of the 11-/11- inhibition LED. If, after lifting of inhibition (end of starting inhibition time delay or opening of contact ), the signal detection phase has not been completed, the relay drops out after the set wait time between two impulses (measured as from the end of inhibition). hibition must last as long as is necessary for the product to detect at least 2 periods. When the signal has not been 'characterised' by the end of the inhibition period, the "inhibition" LED flashes for as long as speed measurement is impossible. It is also possible to inhibit relay M35 S at any time, during operation, by closing. 76 eferences, dimensions :

Characteristics 1 Speed control relays M35 S Environment characteristics Conforming to standards NF EN 60255-6 and IEC 60255-6 Product certifications Pending UL, CSA, GL, C-ck, GOST Marking 1: 73/23/EEC and EMC 89/336/EEC Ambient air temperature around the device Storage C - 40 + 70 Operation C - 20 + 50 Permissible relative humidity Conforming to IEC 60068-2-30 2 x 24 hours + 95 % H at + 55 C (without condensation) ibration resistance Conforming to IEC 60068-2-6 0.035 mm from 10 150 Hz Shock resistance Conforming to IEC 60068-2-6 5 gn Degree of protection Conforming to IEC 60529 Casing IP 30 Terminals IP 20 Degree of pollution Conforming to IEC 60664-1 3 Overvoltage category Conforming to IEC 60664-1 III sulation resistance Conforming to > 500 MΩ, 2 500 IEC 60664-1, 60255-5 ated insulation voltage Conforming to IEC 60664-1 250 sulation test voltage Dielectric test k 2, 1 50 Hz, 1 min. Shock wave k 4 Mounting position without derating Connection Maximum c.s.a. Conforming to IEC3 60947-1 relation to normal vertical Any position mounting plane Solid cable without cable end mm 2 1 conductor: 0.5 4 (AWG 20 AWG 11) 2 conductors: 0.5 2.5 (AWG 20 AWG ) Flexible cable with cable end mm 2 1 conductor: 0.2 2.5 (AWG 24 AWG ) 2 conductors: 0.2 1.5 (AWG 24 AWG 16) ghtening torque Conforming to IEC 60947-1 0.6 1 N.m / 5.3 8.8 Lbf. Housing material Self-extinguishing plastic Power ON indicator Green LED elay state indicator () Yellow LED hibit status indication Yellow LED Mounting Conforming to IEC/EN 60715 On 35 mm 4 rail Supply characteristics ated supply voltage Un Operating range 1/2 24 240 1/2 20.4 264 Polarity on d.c. supply No oltage limits Of the power supply circuit - 15 %, + 10 % Frequency Of the power supply circuit ± 10 % Galvanic isolation, supply/measurement Yes Maximum power consumption 1 5 A and 2 3 W Immunity to microbreaks ms 50 Sensor supply characteristics Nominal voltage ± 0,5 Available current ma 50 for 1/2324 8 Un 8 1/23240 40 for Un < 1/2324 at 25 C Immunity to electromagnetic interference Electromagnetic compatibility Immunity NF EN 61000-6-2 / IEC 61000-6-2 Emission NF EN 61000-6-4, NF EN 61000-6-3, IEC 61000-6-4, IEC 61000-6-3 eferences, dimensions : 77

Characteristics (continued) 1 Speed control relays M35 S Measurement circuit and input characteristics put circuit 3-wire sensor (E1) PNP or NPN,, 50 ma max NAMU sensor (E2), 1.5 kω olt-free contact input (E1), 9.5 kω oltage input (E1) oltage range: 0 min, 30 max put resistance: 9.5 kω High state: 4.5 min Low state: 1 max Minimum impulse time At high state ms 5 At low state ms 5 Measurement range 0.05 0.5 s 0.1 1 s 0.5 5 s 1 10 s 0.1 1 min 0.5 5 min 1 10 min Threshold setting 10 100 % of the range Fixed hysteresis 5 % of the threshold setting Setting accuracy ± 10 % of the full scale value epeat accuracy (with constant parameters) ± 0.5 % Measurement error with voltage variation < 1 % over the whole range Measurement error with temperature variation ± 0,1 % / C max Frequency of input signals Hz 1.7 mhz min, 20 Hz max me delay characteristics esponse time on crossing the threshold ms 15 max epeat accuracy (with constant parameters) ± 0.5 % eset time in memory mode Contact ms 50 minimum s 1 hibition time delay On energisation 0.6 60 s +10 % of the full scale value Delay on pick-up ms 50 Output characteristics Output type Contact type 1 C/O contact Cadmium-free Nominal current A 5 Maximum switching voltage 1/2 250 ated breaking capacity A 50 Minimum breaking current ma 10/ 2 5 Electrical durability 1 x 10 5 operating cycles Mechanical durability 30 x 10 6 operating cycles Maximum operating rate 360 operations/hour under full load Utilisation categories Conforming to IEC 60947-5-1 AC-, AC-13, AC-, AC-15, DC-, DC-13, DC- 78 eferences, dimensions :

11 11 11 11 eference, dimensions, schemes 1 Speed control relays M35 S 105687 eference Function 5 Underspeed, 5 Overspeed Supply Measurement put 1/2 24 240 5 3-wire PNP or NPN proximity sensor (see page 80), 5 Namur proximity sensor, 5 0-30 voltage, 5 olt-free contact. Output eference Weight kg 1 C/O M35 S0MW 0.130 5 A M35 S0MW Dimensions M35 S0MW 72/2.83 35/1.38 2,8 0.11 90/3.54 mm/. Schemes M35 S0MW Contact input hib. - eset 76/2.99 72,5/2.85 Y1 E1 E2 0 Namur proximity sensor input hib. - eset + Y1 E1 E2 0 11 11 z 24...240 z 24...240 NPN/PNP sensor input hib. - eset Y1 E1 E2 0 B BK BU 0-30 voltage input hib. - eset Y1 E1 E2 0 + e 11 11 z 24...240 (1) 1 A quick-blow fuse or circuit-breaker. z 24...240 79