20W DC-DC Converter P20J-Series

Similar documents
20W DC-DC Converter P20H-Series

MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

IG480RW. Series. High Isolation IGBT Driver DC/DC Con vert ers.

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

TEP 100WIR Series, 100 Watt

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

FEATURES. Nominal Output Voltage and Current

Series AM20EW-NZ 20 Watt DC-DC Converter

TEP 75WI Series, 75 Watt

ML100SRI. Series. Ultra-Miniature, 1W High Isolation, SMT DC/DC Con vert ers. Key Features:

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

C B. Models. Operating up to 5000m altitude 5 year product warranty

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

AC/DC Converter SLD05-20Bxx Series

12-15VDC (12V±5%) 24-28VDC (24V±5%)

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

VP ELECTRONIQUE MASSY - Tel

FDC20-48 S 05 W - HC PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Package (4) Control Logic (3)

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Packaging (5) Protection (3) Isolation Voltage (4)

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Fixed Operating Frequency Six-Sided Continuous Shield

1W & 2W Wide Input Range DC/DC CONVERTERS. Features

2:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 88% Ultraminiature Open Frame SMD No Minimum Load Required

12-15VDC (12V±5%) 24-28VDC (24V±5%)

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 84% Fixed Operating Frequency Six-Sided Continuous Shield

Series AM1M-NZ 1 Watt DC-DC Converter

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

IEC/EN/UL60950 & CE certified, EN55032 Class B

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Features. Regulated Converters. RP10-AW 10 Watt 1 x1 Single & Dual Output RP10- _AW/_- DC/DC Converter

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

Series AM3G-NZ 3 Watt DC-DC Converter

Output Current Input Current Max. capacitive Load

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Packaging (4) Isolation Voltage (3) nom. Output Voltage

Universal input VAC <150mW No load power consumption

PXC-M06xxW Dual Output Series: DC-DC Converter Module 9 ~ 36 VDC and 18~ 75 VDC input; ±5 to ±15 VDC Dual Output 6 Watts Output Power

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Datasheet. ACF-10 Series AC/DC Power Module 10W

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 89% Six-Sided Continuous Shield

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

RM- S/_ Protection (3) Isolation Option (4) Single

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Output Voltage* (nom.)(adjustable)

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Industrial Power Supplies

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Universal Power Supplies

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM40-G)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

R0.5S_D ECONOLINE. Features. 0.5 Watt SMD Isolated Single or Dual Output. Derating-Graph (Ambient Temperature) DC/DC-Converter with 3 year Warranty

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

RS2/RD2-E10/T10. RoHS. 1.0W Unregulated Dual Separate Output

Series AM1S-Z 1 Watt DC-DC Converter

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

PT SERIES SIP Package

DC/DC Converter E_S-1WR2 & F_S-1WR2 series

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

RO- S/_ Protection (3) Isolation Option (4) Single

Industrial Power Supplies

PXC05-Dual Output Series: DC/DC Converter Module 9 to 75 Vdc input, 3.3 to 15 Vdc Dual Outputs, 5W

MMA-15 series. 15W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs. Universal 90 to 264VAC Input

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

output voltage output current max (A)

Output Voltage* (nom.)(adjustable)

Protection (3) alternative Pinning Option (4) Single or Dual

Switching Power Supplies

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Snaptec Australia Pty. Ltd.

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Series AM4T-Z 4 Watt DC-DC Converter

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Enclosed Power Supplies

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

DDR-120 series. 120W DIN Rail Type DC-DC Converter

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Industrial Power Supplies

DDR-120 series. 120W DIN Rail Type DC-DC Converter

FS60 Series small size isolated AC/DC converters

Transcription:

20W - Converter P20J-Series Wide 4:1 input range Efficiency up to 89 % Adjustable output voltage Remote control on / off 3000 V isolation Continuous short circuit protection Over voltage protection MTBF > 1 Mio. hours -40...+85 C operating temperature range Model guide Type Input nominal voltage no load typ. Input current full load typ. Output voltage Output current minimum load maximum load Efficiency @ full load typ. Capacitive load (see note 3) [V ] [ma] [ma] [V ] [ma] [A] [%] [µf] max. Single output P20J243R3S 9...36 40 800 3.3 250 5000 86 10000 P20J2405S 9...36 40 935 5 200 4000 89 10000 P20J2409S 9...36 10 950 9 111 2222 88 4700 P20J2412S 9...36 10 950 12 83 1667 88 1600 P20J2415S 9...36 10 950 15 67 1333 89 1000 P20J2424S 9...36 10 950 24 42 834 89 500 P20J483R3S 18...75 20 400 3.3 250 5000 86 10000 P20J4805S 18...75 20 470 5 200 4000 88 10000 P20J4812S 18...75 5 470 12 83 1667 88 1600 P20J4815S 18...75 5 470 15 67 1333 89 1000 P20J4824S 18...75 5 470 24 42 834 89 500 Specifications Input Under voltage protection Start up Shut down P20J24xxS 9 V, max. 5.5 V, min. P20J48xxS 18 V, max. 14 V, min. Filter π - type Reflected ripple current *6 30 map-p, typ. Remote control theshold On state 3.5 12 V, or open input Off state 0 1.2 V Input idle current @ Off state 7 ma, max. Isolation input - output: Rated voltage @ < 1 ma 3000 V for 1 Min. Resistance@ 500 V 10 9 Ω, min Input / output capacitance 500 pf, typ., @ 100 khz Output Voltage tolerance ± 3 %, max. Voltage load regulation ± 1 % @ 5 %...100 % load Line voltage regulation ± 0.5 %, max @ full Vin range Output voltage trim range ± 10 % of Vout nominal Temperature coefficient ± 0.03 % / C Transient recovery time <500 µs, @ 25 % load steps Transient response deviation ±8 % @ 25 % load change Short circuit protection Continuous, hiccup Short circuit restart Automatic Over voltage protection 160 % of nom voltage, max. Over load protection 150 % of full load, typ. Ripple & noise, BW 20 MHz 100 mvp-p, max. General Start up time 10 ms, typ @ R-load Switching frequency 270 khz, typ. Reliability calculated MTBF > 1 Mio. hours MIL-HDBK-217F @ 25 C EMC characteristics Radiated emissions CISPR22 / EN55022 Class A Radiated emission, with Fig. 2 CISPR22 / EN55022 Class B Conducted emissions CISPR22 / EN55022 Class A Conducted emissions, CISPR22 / EN55022 Class B with Fig. 2 ESD (± 4 kv) EN61000-4-2 perf. crit. B RS (10 V/m) EN61000-4-3 perf. crit. A EFT, (± 2 kv) with Fig. 2 EN61000-4-4 perf. crit. B Surge, (± 2 kv) with Fig. 2 EN61000-4-5 perf. crit. B CS (3 Vrms) EN61000-4-6 perf. crit. A Immunity of voltage dip, drop and EN61000-4-29 perf. crit. B short interruption (0..70 %) Environmental Operating ambient temperature -40 C to +85 C with derating Storage temperature -55 C to +125 C Storage humidity 5 95 %, non condensing Cooling Free air convection Physical PCB module 26.5 x 51.5 x 12 mm, 24 g Dimension Chassis module 31.5 x 76 x 21.2 mm, 46 g Weight DIN rail module 31.5 x 76 x 25.8 mm, 66 g Package material Plastic, UL94V-0 rated Potting material UL94V-0 rated Absolute max. ratings Pin soldering temperature 300 C for 10 sec 1.5 mm distance from body Max. input P20J24xxS -0.7 50 V voltage < 1 sec P20J48xxS -0.7 100 V Vibration, X, Y & Z axis 10..55 Hz, 10G, 30 minutes Page 1 of 6

20W - Converter P20J-Series 1) Recommended circuit The P20J series is been tested according to the following recommended test circuit before leaving the factory (see Figure 1). If you want to further decrease the input / output ripple, you can increase a capacitance values properly or choose capacitors with low ESR, but the total capacitance of the filter capacitor must not exceed the maximum load capacitance value (see Model guide table). Figure 1 Cin + Vin - Vin + Vout - Vout Cout Recommended peripheral components to figure 1 a Cin Cout P20Jxx3R3S 470 µf P20Jxx05S 470 µf P20Jxx09S 220 µf 100 µf P20Jxx12S 220 µf P20Jxx15S 220 µf P20Jxx24S 100 µf Figure 2, Recommended EMC circuit Fuse LCM +Vin CY +Vout U C1 CX CX Cout Load MOV -Vin -Vout Recommended EMS circuit Recommended EMi circuit CY Recommended peripheral components to circuits in figure 2 Fuse MOV C1 CX LCM CY Cout Slow blow Type P20J24xxS 2.5 A S14K35 330 µf, 50 V 1 µf, 50 V 6.8 mh 1 nf, 3 kv See table at P20J48xxS 1.5 A S14K60 330 µf, 100 V 1 µf, 100 V 6.8 mh 1 nf, 3 kv figure 1 Input reflected ripple measure circuit Measure point + Vin + Vout Lin 4.7 µh Cin 220 µf ESR < 1 at 100 khz - Vin - Vout Load The input reflected ripple current is measured with inductor Lin and capacitor Cin to simulate source impedance. Page 2 of 6

20W - Converter P20J-Series Application note to remote control / trim function + Vin + Vout Remote control input R trim down Open switch for ON -state R trim up - Vin - Vout Trim down circuit P20JxxxxS R1 - + R2 R3 +Vout Rtd Common Trim up circuit P20JxxxxS R1 - + R2 R3 +Vout Common Rtu VRef VRef -Vout -Vout Calculation for trim down resistor (Rtd) or trim up resistor (Rtu) Model series R1 [kω] R2 [kω] R3 [kω] V Ref [V] Rtd min. [kω] Rtu min. [kω] P20Jxx3R3S 4.801 15 1.24 8.65 4.27 P20Jxx05S 2.883 10 1.16 4.9 P20Jxx09S 7.5 15 29.4 7 2.864 P20Jxx12S 10.971 17.8 2.5 53.5 6.6 P20Jxx15S 14.497 17.8 78.6 9.1 P20Jxx24S 24.872 20 162 8.37 Maximum output voltage adjust range ± 10 % of Vout nominal, see min. Rtd / Rtu Trim down resistor formula Trim up resistor formula b= Vout-Vref Vref *R2 a= Vref Vout-Vref *R1 Rtd= R1*b R1-b -R3 Rtu= R2*a R2-a -R3 Page 3 of 6

20W - Converter P20J-Series Page 4 of 6

20W - Converter P20J-Series Dimensions standard version P20JxxxxS Pinning Pin Single 1 - Vin 2 + Vin 3 + Vout 4 Trim 5 - Vout 6 Remote control Unit: mm Pin diameter tolerance: 0.1 mm General tolerances: 0.5 mm Dimensions chassis mountable version P20JxxxxSA2 Unit: mm General tolerances: 0.5 mm Wire range: 12 AWG 15 AWG Connecting assigen Terminal Funktion 1 Remote control 2 - Vin (GND) 3 + Vin 4 - Vout (0V) 5 Trim 6 + Vout Page 5 of 6

20W - Converter P20J-Series Dimensions DIN - rail mountable version P20JxxxxSD Unit: mm General tolerances: 0.5 mm Wire range: 12 AWG 15 AWG Connecting assigen Terminal Funktion 1 Remote control 2 - Vin (GND) 3 + Vin 4 - Vout (0V) 5 Trim 6 + Vout Note: 1. Minimum load should be more than 5 %, otherwise the ripple exceeds the specificated values. Operation at lower than 5 % load will not damage the converter. 2. Maximum capacitive load is tested within the input voltage range and at full load. 3. All specifications measured at Ta 25 C, humidity < 75 %, nominal input voltage and rated output load unless otherwise specified. 4. It is not recommended to increase the output power capability by connecting two or more converters in parallel. 5. The converters are not hot swappable! Ordering information (PCB) Printed circuit board mountable version Chassis mountable version DIN - rail mountable version P20JxxxxS P20JxxxxSA2 P20JxxxxSD PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 10.15 f Page 6 of 6