B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

Similar documents
B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit

SOLARIMMERSION IV Advanced Installation Manual v1.9

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

Orbital smart Tunable Downlight

Conveyor Belt Alignment Switches from IDEM

Specifications, Installation, and Operating Instructions

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

TP&N DISTRIBUTION BOARD TYPE B RANGE

DST8-DIN 8-way DMX Splitter Instruction Manual

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Weathersafe Vision. Installation & Operating Instructions

10AX Metal Clad Switches (Modular) 10AX Plate Switches (Modular)

LC SmartGlass SPD SmartGlass

Quick Start Installation and User Manual

LF3-400 Three Phase Frequency Converter, Operation and Maintenance.

Protect Circuit Protection

Defender B Board. Make The Switch

SPM Series Plug-in Surge Protection

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Dual Voltage Shaver Socket

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

RCDs RCBOs MCBs Isolating Switches Switchboards

Sollatek SVS Range Voltage Stabilisers User Manual

45A Cooker Switches. 45A Cooker Switches

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Wiring Accessories for a Smarter Home

AIR COOLED MODULAR RECTIFIER

INSTALL & SET-UP GUIDE

PRO-1250D CT MID DIN rail three phase four wire energy meter.

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

MAINS DISTRIBUTION UNIT MDU14-CO

CONTROL PANEL WIRING SPECIFICATIONS

Installation. Symmetra MW II kw 400 V. UPS Summary Normal Normal

LF1-400 Frequency Converter, Operation and Maintenance

MAJOR VA Power Inverter

20A Control Switches

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Operating & Maintenance Instructions Dry Running Protection Device DRP-001

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

MULTI-MONITOR CONTROLLER USER MANUAL

Pulsar EXtreme 2000/3000 VA

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Loads and Motor Switchgears

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

THIS PAGE LEFT BLANK

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

Installation Manual for D244X Series 24-volt Power Supplies

Single-Core PVC 6491X

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

User's Guide. Extech AM A AC Analog Clamp Meter

PV Rapid Shutdown device

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

QF(26) - Series Miniature Circuit Breakers - High Rating ( A)

Digital Dimmer Unit with RCK system Instruction Manual

Panel Installation Datasheet

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

Table of Contents. Safety. Attention. Warnings

Hoist Controller for Low Voltage Hoist Instruction Manual

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

10AX Toggle Switches

Hoist Controller for Low Voltage Hoist

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

The following lighting types ARE NOT COMPATIBLE with the TT401 LED Dimmers:

Wireless DMX Transmitter/Receiver/Splitt Instruction Manual

User Guide Automatic Transfer Switch (ATS)

Common Departures Interconnecting Facilities Requirements

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

Hoist Controller for Low Voltage Hoist Instruction Manual

MP7. Uninterruptible Power Supply

SPM Series. Plug-in Surge Protection

ABL1REM24062 regulated SMPS - single phase V input - 24 V output W

Dorman Smith Loadbank 125 MCCB Panel Boards

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

Digital Room Thermostat

Technical Data Sheet Medium Current Power Surge Filters

Model HM-535 Power Supply Installation and Service Instructions

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

LC35SE-CC LOOP

LC51SE-CC LOOP

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Telephone and Data Sockets

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

Transcription:

Installation Manual V2.2 November 2015

PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations, BS7671 (17th Edition or later) and current Building Regulations. Ensure the electrical supply is disconnected before installation or removing the cover of the B60PVM unit. Contents Product Description 3 Warning Notice 3 Safety Advice 3 Introduction 4 Installation Connection Diagram 5 Dimensions & Mounting the unit 6 Fixing Dimensions 7 Electrical Connections 8 Specifications 9 2

Product Description The single phase B60 PVM Domestic Voltage Optimisation unit is designed for use in domestic and light commercial / retail applications. Installed between the electricity meter and main consumer unit, the B60 PVM offers 18 volt subtractive performance. The unit is not intended for any purpose other than that defined within this document. Warnings Please read and observe the following notices carefully. These warnings must be observed when installing and operating the Domestic Voltage Optimisation unit. All relevant supplies must be isolated or disconnected before commencing any work. This product must be installed by a competent person in accordance with the IEE Wiring Regulations, BS7671 (17th Edition or later) and any relevant Building Regulations. ELECTRICAL HAZARD Once installed, the unit has a Live Mains Supply (230v or higher) within the enclosure. The cover must not be removed until the supply to the unit has been isolated or disconnected. Safety Advice The unit must be installed in a dry ventilated location, it must never be covered or have restricted ventilation. The B60 PVM voltage optimisation unit is rated for a maximum 60A load. For any information not contained within this document, please contact our technical support team on 0115 9303 628. 3

Introduction The Accendo B60 PVM is a single phase Voltage Optimisation unit designed to work with PV installations. The unit reduces the incoming supply voltage by 18v (i.e.: a 240v supply would be reduced to 222v). It is designed to be connected in series with the incoming supply installed between the main electricity meter for the dwelling, and the consumer unit. The Accendo B60 PVM has short circuit, overload and thermal protection built in. Rated at 60 Amps, the unit is suitable for the majority of domestic and light commercial / retail installations. The unit will tolerate an overload of 70 Amps for a period of no more than 30 minutes before the thermal trip mechanism of the incoming MCB operates. The unit has a dedicated PV supply RCBO and a MID meter. 4

Connection Diagram 5

Mounting the Accendo B60 PVM Unit The unit is designed to be installed between the main electricity meter and consumer unit in the most practical and accessible position available. The installation location should be clean, dry and well ventilated. Please refer to the diagram below for the dimensions and mounting arrangements of the unit. NOTE: The unit weighs approximately 10.0kgs. Always handle the unit with both hands. 6

Fixing Dimensions 7

Electrical Connections The unit is supplied with a 63 Amp miniature circuit breaker that provides overload and short circuit protection for the unit. The transformer is fitted with an embedded thermal switch. Should the temperature of the transformer increase beyond acceptable levels the thermal switch will operate and automatically shut off the supply to the transformer by tripping the incoming MCB (CP1). Once the transformer temperature has returned to an acceptable level the thermal switch will reset and the MCB can be closed. The user wiring connections are indicated in the diagram below: 8

Specifications Description Input (Volts) Output (Volts) Max Load Dimensions Weight B60 PVM Domestic Nominal input voltage 235 253v, 50Hz, Single Phase AC Nominal input voltage less 18v 14kW 364mm x 235mm x 100mm Approximately 10.0 kgs Operating Temperature -5 C to + 40 C Terminal Capacity Incoming Live = 35.0mm2 Outgoing Live = 35.0mm2 Incoming Neutral = 35.0mm2 Outgoing Neutral = 35.0mm2 Miniature Circuit Breaker 63 Amp 6kA Type B to BS EN 60898 Enclosure Ingress Protection Cable Entry Facility Mild Steel Powder Coated IP20 Bottom 2 x 32mm, 1 x 20mm Diameter Standards MCBs to BS EN 60898 Document Revision V2.2 November 2015 Warranty The B60 PVM Domestic is guaranteed for a period of 12 months from the date of purchase. To extend this warranty to 5 years record the serial number of the unit on the enclosed Warranty Card and return it with proof of purchase to info@matt-e.co.uk This warranty is limited to the replacement of faulty components only. 9

Notes 10

Warranty Card B60 PVM Domestic Model No: Serial No: Date of installation: Installer Details: Site Address: For further information, get in touch with matt:e t: 01827 61231 e: info@matt-e.co.uk

Caring about your World Please return this Warranty Card along with proof of purchase to matt:e Ltd, Unit 1c Neander Lichfield Road Industrial Estate Tamworth Staffordshire B79 7XA AFFIX STAMP