HP NetServer E 800 Installation Guide

Similar documents
Upgrading and Servicing Guide

Upgrading and Servicing Guide

Upgrading and Servicing Guide

Upgrading and Servicing Guide

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Upgrading and Servicing Guide

HP NetServer E Series (E 30 and E 40) User Guide

Tower to Rack and Rack to Tower System Conversion Guide

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

HP NetServer LC 3 User Guide

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

Upgrading and Servicing Guide

SCSI Cable Installation Instructions

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

HP ProLiant SL160z G6 Server

HP NetServer LH 3000/LH 3000r Service Manual

Replacing the Battery HP t5730 and t5735 Thin Clients

HP Netserver LP 2000r Service Manual

HP ProLiant DL165 G7 Server

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

HP VISUALIZE B2000 UNIX Workstations

Model A4268A FWD SCSI Adapter Installation and Service Guide. Embedded Systems Operation Part No. A Edition E1097

Removing and Replacing Parts

I/O Upgrade Manual. HP3000/9x9KS and HP9000 K-Class Enterprise Servers. A Printed in U.S.A. January 1998 Edition 6 E0198

HP ProLiant MicroServer

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number

User s Guide. HP Vectra VL 5/xxx

Installing and Upgrading Memory and Virtual Private Network Modules

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Wall-Mounting your HP TouchSmart. User Guide

service handbook chapter

Installing and Removing SDRAM and DRAM

IBM Systems. Quick start guide for IBM System p5 505 ( )

Maintaining and Troubleshooting Your E-4200 System

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Intel Desktop Boards D845HV and D845WN Quick Reference

~Pl ~i~.z~j6 HP Part No. A Printed in USA, June, 1996 Edition 4, E0696. Internal Peripherals Upgrade Guide

Dell Inspiron XPS and Inspiron 9100 Service Manual

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Dell Precision M4600 Owner's Manual

PIX 520. PIX 520 Product Overview CHAPTER

Quick start guide for p5 520 ( )

Replacing/Upgrading Mac Pro Processors (Early 2008)

Replacing the Power Supply

Dell Latitude C800 Service Manual

Packard Bell. EasyNote BU Series. Disassembly Guide

Quick Reference This guide is written for technically qualified personnel with experience installing and configuring desktop boards.

Quick start guide for i5 520 ( or )

Intel Server Board S2600BP Intel Compute Module HNS2600BP Product Family

Computer Setup (F10) Utility Guide HP Compaq d220 and d230 Microtower

Gateway Profile 4 service guide

INSTALLATION INSTRUCTIONS for the Kodak ADAPTIVE PICTURE EXCHANGE (APEX) 26, 48, 74, and 122

ProLiant ML350 Setup and Installation Guide

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

G-MAX TM. ATX Series User s Manual

CPU Upgrade Manual. Model 9x9KS and Series Kxx0 HP 3000 and HP 9000 Enterprise Servers

2500C/C+/CM. Professional Series Color Printer NETWORK GUIDE

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303

Replacement Instructions. Backplane PCA for the HP Router 650

SCSI HP Administrator s. Vectra PCs Guide. Kayak PC

ThinkCentre Hardware Installation and Replacement Guide

Dell Inspiron N5110 Service Manual

A9890A RAID Smart Array 6402 Controller Quick Installation Guide

the server with the best price/performance value for small businesses

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

Dell Latitude C800 SERVICE MANUAL. support.dell.com

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

HP ProLiant DL385 Server Maintenance and Service Guide. January 2005 (First Edition) Part Number

Maintaining E-Series Routers

Removing and Installing the ISA and the ISM

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001

120Ra-1 Pentium III Processor Installation Insert

Field Service Guide Supplement for the NS 7000/030

HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide. September 2003 (Fourth Edition) Part Number

Agilent Technologies 16700B-Series Logic Analysis Systems. Installation Guide. Publication number November 2002

This section describes how to install the following options: #!! #!% *+! Use Figure 8-1 to locate the system board features.

Dell Latitude V710/V740 Service Manual

To connect the AC adapter:

Contivity Extranet Switch Installing Hardware Options Guide

Table of Contents - 1. Predator PO3-600 User s Guide

Maintaining the ERX System

Quick Setup & Getting Started Business PCs

Alienware X51 Service Manual

IBM. Service Guide and User's Guide. Supplement to the RS/ P Series SN

Hard Drive/Solid-State Drive Replacement Instructions

GS-SR104 Rack Mount Server System Installation Guide

Dell Precision Workstation T7610 Owner's Manual

H3C S12500 Routing Switch Series

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6417, 6418, 6449, 6453

ALIENWARE AURORA SERVICE MANUAL 01/

H4 Series Hardware Replacement Guide

HP Server tc2110 Network Operating System Installation Guide

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

ProLiant 800 Servers Supporting Pentium II Processors and 100-MHz System Bus Setup and Installation Guide

Memory (RAM) Replacement Instructions. apple PowerBook (FireWire) Tools Required. Electrostatic Discharge (ESD)

Installing the Cisco Unified Videoconferencing 3545 MCU

Hardware Replacement Guide

Transcription:

HP NetServer E 800 Installation Guide HP Part Number D9394-90000 Printed June 2000

Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company. Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, Windows NT, Windows 95 and Windows 2000 are registered trademarks of Microsoft in the U.S. and other countries. Novell and NetWare are registered trademarks of Novell, Incorporated in the U.S. and other countries. Symantec is a registered trademark of Symantec, Incorporated. pcanywhere32 is a trademark of Symantec, Incorporated. Torx is a registered trademark of CamCar/Textron, Incorporated. Hewlett-Packard Company Network Server Division Technical Communications / MS 45SLE 10955 Tantau Avenue Cupertino, California 95014 USA Copyright 2000, Hewlett-Packard Company. Audience Assumptions This guide is for the person who installs, administers, and troubleshoots LAN servers. Hewlett-Packard Company assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. ii

Contents Setting Up the HP NetServer E 800... 1 Introduction... 1 Step 1: Attaching all the Cables... 2 Step 2: Opening the HP NetServer... 3 Step 3: Installing Memory... 5 Step 4: Installing Mass Storage Devices... 6 Step 5: Installing Adapter Boards... 10 Step 6: Installing a Second Processor... 14 Step 7: Configuring the HP NetServer... 19 iii

Introduction This installation guide is a quick reference for HP NetServer E 800 installation. Skip any steps that do not apply to your installation. Refer to the figures below for connection and operating information. For more information, refer to the HP NetServer E 800 User Guide. Flexible Disk Drive CD-ROM Drive Optional Back-Up Tape Drive Power ON/OFF/ Sleep Switch Power ON/ OFF/Sleep LED SCSI Drive Activity LED Unlocked Position Locked Position Power Mouse Keyboard USB(2) Serial A Parallel Serial B Video (SVGA) Key Lock LAN External SCSI (Optional) Fold-Out Feet (4) 1

Step 1: Attaching all the Cables If you are not installing any accessories, attach all available cables to the respective connectors, then go to "Step 7: Configuring the HP NetServer." NOTE The two USB connectors are reserved for printers, scanners, and external modems. The NetServer does not support USB connections for the keyboard and mouse. Power Mouse Keyboard Power Cord Strain Relief LAN Video SVGA 2

Step 2: Opening the HP NetServer Tools Required: ¼ inch flat-blade screwdriver Torx T-15 driver WARNING Before removing the cover, always disconnect the power cord and remove the telephone cable. Disconnect the power cord to avoid exposure to high energy levels that may cause burns when parts are short-circuited by metal objects such as tools or jewelry. Disconnect telephone cables to avoid exposure to shock hazard from telephone ringing voltages. Slotted Thumbscrews(6) Key- Lock 3

Front of Chassis Cover Cover Bottom of Chassis Latch Opening Air Duct Latch 4

Step 3: Installing Memory Use only HP DIMMs, which are 3.3V, 168-pin, PC133 (133 MHz), buffered SDRAM DIMMs in 128 MB, 256 MB, or 512 MB. DIMMs may be installed in any slot, in any combination (sizes mixed), in any order, but HP recommends starting at slot 0 and filling the slots in order with the largest size first: 0, 1, 2, and 3. Ensure both latches close on the DIMM when completely installed. DIMM Slot Notches Keys Retaining Latches 0 1 2 3 System Board 5

Step 4: Installing Mass Storage Devices The NetServer is internally limited to 7 mass storage shelves. The flexible disk drive and CD-ROM drive, which are standard on all models of the HP NetServer E 800, occupy shelves 1 and 2 respectively. If a backup tape drive is used, it will occupy shelf 3. Shelves 4, 5, 6, and 7 are available for up to four SCSI hard drives and at least one is required for the boot drive. IDE drives are not supported in this NetServer. CAUTION Do not connect high voltage differential (HVD) SCSI devices on the SCSI bus or you will damage the other devices. 1. Remove the Drive Cage by loosening the three captive screws. Top of Chassis (Side view) Shelf 1 Shelf 2 Hard Disk Drive Cage (removable) Shelf 3 Captive Screws (3) Shelves 4-7 (4) Front of HP NetServer 2. Install the SCSI hard disk drive. 6

3. Connect the cables (data & power). 4. Replace the drive cage. Slots for Tabs Tabs(2) Captive Screws (3) First insert screws through round holes in back (one on each side). CAUTION All mounting screws used to thread into the hard disk drive must be #6-32 and not exceed ¼-inch in length. Longer screws may cause internal damage to the mass storage device. Damage caused by incorrect mounting screws is not covered by the HP warranty. 7

5. If necessary, install the internal accessory SCSI cable into SCSI channel B and connect to the SCSI drives or optional backup tape drive. Use HP NetServer E 800 External/Internal SCSI Cable Kit, part number P1773A. Terminator SCSI B Connector SCSI Connectors (2) NOTE The slower speed of the tape drive may slow disk access time for the Ultra-2 SCSI drives. You may connect the tape drive separately from the Ultra-2 SCSI drives using the optional internal accessory SCSI cable. 8

6. If necessary, install the external/internal SCSI cable into SCSI channel B and connect to the knock-out in the rear of the chassis. Use HP NetServer E 800 External/Internal SCSI Cable Kit, part number P1774A. WARNING Ensure you do not touch the sharp metal edges from the knock-out once you have removed it. The empty knock-out leaves sharp metal on the edges. External SCSI Connection SCSI B Connector 9

Step 5: Installing Adapter Boards The NetServer E 800 has two PCI (Primary and Secondary) busses and both are pear-to-pear, which provides approximately equal performance, except when using the two 64-bit slots versus the 32-bit slots. PCI Slots PCI Bus Slots 1 through 4 Primary PCI Bus Slots 5 through 7 Secondary PCI Bus NOTE Some full-length PCI boards may need a plastic "handle" (board extension) on one end to stabilize the board in the NetServer. If the board requires one and it is not installed, you may need to install the handle on the board before installing it in the HP NetServer. Wake- On-LAN PCI Board s Plastic Extension 10

System Board (Top View) 32-bit PCI Slot 1 PCI Slot 2 Wake- On- LAN Full- Length 32-bit 64-bit PCI Slot 5 64-bit PCI Slot 6 32-bit PCI Slot 7 11

Chassis Slot Cover Cross- Section View 12

13

Step 6: Installing a Second Processor Both processors must have the same clock speed and cache size. Use only processor upgrade kits with the same HP product number. This ensures the product numbers are compatible and the processor type, clock speed, and cache size are the same. CAUTION Do not open the new processor s protective bag or remove it from the bag until you are ready to install it. Always wear a wrist-strap and use a static-dissipating work surface connected to the chassis when handling components. Ensure the metal of the wrist strap contacts your skin. Before you remove a processor from the anti-static container, touch a grounded, unpainted metal surface on the HP NetServer to discharge static electricity. NOTE Some processor speeds listed for this HP NetServer may not be supported. For the latest support information, visit the HP web site: http:/www.hp.com/go/netserver 14

1. Open the ZIF (Zero Insertion Force) lever on the processor socket. The ZIF lever must open completely to a full 90 before removing the terminator from the socket. 2. Remove the terminator from the processor socket. Terminator Processor Socket ZIF Lever NOTE Retain the terminator for future use. The NetServer will not operate properly if using only one processor with no terminator installed. 15

3. Insert the processor into socket, matching pin-1 to marker. Pin-1 Marker 4. Close the ZIF lever with a click. The ZIF lever should click when closed. 16

5. Place the Heatsink-Fan on top of processor and follow the steps A-C in the figure below. Hook Latch (hidden) A. Rotate and hook. Thumb Latch B. Rotate back and hook the Thumb Latch. Tab C. Ensure this ridge rests between the CPU and the edge of the processor socket. Tab Processor Socket Base CAUTION Failure to properly seat the heatsink-fan assembly on the processor will cause it to overheat and shutdown the NetServer within 20 seconds of powering on. It is possible there would be no messages displayed or the monitor may not have come on fully in time to see a message if it were displayed. The processor may be damaged if it is allowed to overheat. 17

6. Connect the fan connector to the respective connector on the system board. System Fan Power Connector Processor 1 (CPU 1) CPU 1 Fan Processor 2 (CPU 2) CPU 2 Fan CAUTION Failure to connect the fan connector will cause the processor to overheat and the NetServer will shut down without any messages being displayed. If the processor is allowed to overheat, damage may occur. 18

Step 7: Configuring the HP NetServer 1. Power on the HP NetServer and the monitor: Insert the HP NetServer Navigator CD-ROM in the CD-ROM drive. The server should boot from the HP NetServer Navigator CD on its own, if not, turn the power off, wait 10 seconds and turn the power back on again. If the system fails to boot, follow the instructions on the screen. Press [F2] to enter Setup, or Press [F4] to accept automatic configuration update 2. Configure the NetServer and Install the Network Operating System (NOS): From the HP NetServer Navigator Main Menu, view the system Readme from the HP Navigator main menu for the most current installation information. Use the HP NetServer Navigator to configure the server. Start with either the "Configuration/Installation Assistant" or "Configure the Server" option from the Main Menu (you will see one or the other depending upon your version of the CD). If you use Navigator s Express or Guided modes you will be prompted through the process. During the configuration process you will be asked to select the NOS Installation Mode. NOTE If certain versions of the Novell NetWare or Microsoft Windows NT Server are used, a prompt will appear indicating selections of automated or manual NOS installation. Choose the automated mode for first-time installation of Novell NetWare or Microsoft Windows 2000 (NT) Server on a factory-configured HP E-Series NetServer. You will be guided through the process by a series of HP display screens. Perform a manual install if you are installing a NOS other than Novell NetWare or Microsoft Windows 2000 (NT) Server, you have replaced HP components (for example, replacing an HP Network Interface Card (NIC) with a NIC not on HP s Tested Products List (TPL) or adding a 19

SCSI controller board from a third-party). You will need to use the NOS vendor s installation process. Be sure to first view and print the HP-customized NOS installation instructions and create the driver disk(s) for the NOS you are installing before leaving Navigator and installing your NOS. 3. Install or Configure Tape Backup Software: If your NetServer includes a preinstalled tape backup device, install and/or configure the tape backup software now. Refer to the Tape Backup Getting Started Guide for instructions on installing and configuring the tape backup software. 4. Refer to the HP NetServer Online Documentation CD-ROM: Use this CD-ROM for updated information about your HP NetServer and as reference for any additional information not provided in this Installation Guide. NOTE If you plan to use the Remote Console feature to run HP TopTools utilities remotely, the Utility Partition must be created using the HP NetServer Navigator. If you choose the Express or Guided mode of configuration, the partition will be created automatically. Otherwise, you will need to choose Install/Update Utility Partition during the custom configuration process. 5. Run DiagTools: (Optional) Create the HP DiagTools diskettes from the NetServer Utilities (or Diskette Library) on the HP NetServer Navigator CD-ROM. Run HP DiagTools and after completing all the configuration topics, save the support ticket to a diskette for future reference. 20