Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

Similar documents
Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

Class:ELOLib 1 COMOS. Platform Class documentation ELOLib_dll. Programming Manual. Siemens Distributor 09/2014 A5E AA

PD PA AP How To Configure Maxum II TimeServer Access

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Optional package printer driver V1.4

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

COMOS. Lifecycle 3D Integration Operation. Publisher 1. COMOS PDMS Integration 2. Material management 3. COMOS 3D viewing 4.

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

COMOS. Operations Shutdown. Introduction 1. Milestones 2. "Shutdown management" plugin 3. "Quick edit" plugin 4. User interface reference 5

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

COMOS. Lifecycle Material Management. General information 1. Introduction 2. Definitions 3. Creating material in COMOS 4

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

COMOS Material Management. Operation COMOS. Process COMOS Material Management Operation. Trademarks 1. Introduction. Definitions 3

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

COMOS Material Management. Operation COMOS. Process COMOS Material Management Operation. Trademarks. Introduction. Definitions

COMOS. Lifecycle 3D Integration Operation. COMOS PDMS Integration 1. Material management 2. COMOS 3D viewing 3. References 4.

Class documentation Lib_dll COMOS. Platform Class documentation Lib_dll. Trademarks 1. Lib.dll. Programming Manual A5E

COMOS. Automation Automation interfaces. Note on file-based data exchange 1 SPI 2. Generic Excel import 3. Process visualization via OPC client 4

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

Siemens Controls. SAP interface COMOS. Platform SAP interface. Trademarks 1. Introduction. Technical prerequisites 3

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

COMOS. Automation COMOS Automation Interfaces SPI 1. Generic Excel import 2. Process visualization via OPC client 3.

COMOS. Operations MRO. Introduction 1. Maintenance objects 2. "General maintenance" plugins 3. "Events" plugin 4. "Resources" plugin 5

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

COMOS. Automation Logical. Basic principles 1. Configuring function diagrams based on IEC 2. Code generation based on IEC

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

COMOS. Lifecycle Project Quality Management. Introduction 1. Import 2. Attributed search 3. Check out and check in function 4. DVM document package 5

Basic principles 1. Configuring function diagrams based on IEC 2. Administration 3 COMOS. Automation Logical. Operating Manual 04/2015 A5E AD

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC NET. S TeleControl MSC300_Library program block library. Block library for TCSB (V3) WDC_S7_300_... (FB92) 2 UDT_WDC_PARAM (UDT91) 3

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

COMOS. Lifecycle 3D Integration Operation. COMOS PDMS Integration 1. Material management 2. COMOS 3D viewing 3. References 4.

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

COMOS. Operations MRO (Maintenance Repair and Overhaul) Introduction 1. Maintenance objects 2. "General maintenance" plugins 3.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

COMOS. Lifecycle COMOS Walkinside Getting Started. Security information 1. Which functionalities are not covered in this manual? 2

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Logical COMOS. Automation Logical. Trademarks 1. Basic principles. Configuring function diagrams based on IEC

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

Portable & Direct COMOS. Operations Portable & Direct. Trademarks 1. Introduction. Portable 3. "Direct" plugin 4. User interface reference

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Scope and Purpose of this. Guideline. Requirements. Limitations. MindSphere. Testing. MindConnect LIB Developer. Branding.


Siemens Automation Products

Configuration limits for products of the HARDNET-PB DP-Base 1

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

Siemens Drives & PLCs

Transcription:

1 COMOS Platform Programming Manual 04/2014 A5E32035508-AA

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Order number: A5E32035508-AA P 05/2014 Subject to change Copyright Siemens AG 2014. All rights reserved

Table of contents 1 Class: POptions...5 1.1 Public Subs...5 1.1.1 SetOption...5 1.1.2 RefreshOptions...5 1.1.3 ScanPipeClasses...5 1.1.4 ResetPreferredCDeviceForFunctionCode...6...6 1.2.1 GetOptionSystemDefault...6 1.2.2 CheckOptCode...6 1.2.3 GetConnectionTypeProperties...6 1.2.4 GetConnectionTypeProperties2...6 1.2.5 GetIndexOption...7 1.2.6 GetIndexOption2...7 1.2.7 GetIndexOptionWithSymbol...7 1.2.8 GetOptionFromProject...7 1.2.9 GetOption...8 1.2.10 GetHeaderClassTable...8 1.2.11 GetStdTableBySystemFullName...8 1.2.12 PipeClassRootCDevice...8 1.2.13 GetConnectionTypeTable...8 1.2.14 GetPrefixOrSeparatorForClassAndDetailClass...9 1.2.15 GetPrefixOrSeparatorByString...10 1.2.16 GetPrefixOrSeparatorByStringAndProject...12 1.2.17 GetOptions...12 Programming Manual, 04/2014, A5E32035508-AA 3

1 1.1 Public Subs 1.1.1 SetOption SetOption ( ByVal optcode as Long, ByRef POption as Variant ) Sets a project option to a new value. Only applies to the current COMOS instance: when COMOS is closed and re-opened, the default value applies once again. The number of the project option to be changed Example: "69" for "Automatic referencing of documents in @Namesystem". Alternative: Call via constant, e.g. "PO_AutoDocRefNameSystem". The alternative is not available in the script, but only from DLLs with a reference to ivbcomos.dll. Parameter POption The new value. Please note: Depending on the POption, the type can be String, Integer, Long, etc., or also a COMOS object. COMOS objects can be identified by the prefix "IComos". 1.1.2 RefreshOptions RefreshOptions ( ByVal WorkSet as IComosDWorkset ) Performs a complete update of all POptions for the current database. Parameter WorkSet The current workset instance. Has the same meaning as the currently open database. 1.1.3 ScanPipeClasses ScanPipeClasses ( Optional ByVal CDevPipeClass as, Optional ByVal Prefix as String = "", Optional ByVal Recursive as Boolean = False ) Parameter CDevPipeClass Parameter Prefix Parameter Recursive For internal use. Programming Manual, 04/2014, A5E32035508-AA 5

1.1.4 ResetPreferredCDeviceForFunctionCode ResetPreferredCDeviceForFunctionCode ( ) For internal use 1.2.1 GetOptionSystemDefault GetOptionSystemDefault ( ByVal optcode as Long ) as Variant Supplies the default value of the project option. The number of the project option whose default value is to be returned. 1.2.2 CheckOptCode CheckOptCode ( ByVal optcode as Long ) as Boolean Checks the validity of a project option. A POption is valid if its option code is between 1 and the total number of POptions. The number of POptions is recorded in ivbcomos.dll. The number of the project option to be checked. 1.2.3 GetConnectionTypeProperties GetConnectionTypeProperties ( ByVal ConLayer as String, ByVal ConCategorie as String, Optional ByVal Planart as String = "" ) as TypConnectionType Calls GetConnectionTypeProperties2. Recommendation: Use GetConnectionTypeProperties2, see chapter GetConnectionTypeProperties2 (Page 6). Parameter ConLayer Parameter ConCategorie Parameter Planart 1.2.4 GetConnectionTypeProperties2 GetConnectionTypeProperties2 ( ByVal ConLayer as String, ByVal ConCategorie as String, ByRef bstdvaluefound as Boolean ) as TypConnectionType 6 Programming Manual, 04/2014, A5E32035508-AA

Parameter ConLayer Parameter ConCategorie Parameter bstdvaluefound For internal use. 1.2.5 GetIndexOption GetIndexOption ( ByVal optcode as Long, ByVal Index as Variant ) as Variant Parameter Index Calls GetIndexOption2. Recommendation: Use GetIndexOption2, see chapter GetIndexOption2 (Page 7). 1.2.6 GetIndexOption2 GetIndexOption2 ( ByVal optcode as Long, ByVal Index as String, ByRef bstdvaluefound as Boolean ) as TypConnectionType Parameter Index Parameter bstdvaluefound For internal use. 1.2.7 GetIndexOptionWithSymbol GetIndexOptionWithSymbol ( ByVal optcode as Long, ByVal Index as Variant, Optional ByVal Planart as String = "" ) as Variant Parameter Index Parameter Planart Obsolete; only provided for compatibility reasons. 1.2.8 GetOptionFromProject GetOptionFromProject ( ByVal optcode as Long, ByVal otherproject as IComosDProject ) as Variant Returns the value of a POption from another project. Programming Manual, 04/2014, A5E32035508-AA 7

The number of the project option whose value is to be returned. Parameter otherproject The object of the COMOS project from which the POption is to be calculated. 1.2.9 GetOption GetOption ( ByVal optcode as Long ) as Variant Returns the value of a POption from the current project. The number of the project option whose value is to be returned. 1.2.10 GetHeaderClassTable GetHeaderClassTable ( ByVal TableName as String ) as IComosDStandardTable Parameter TableName For internal use. 1.2.11 GetStdTableBySystemFullName GetStdTableBySystemFullName ( ByVal StdTableFullName as String ) as IComosDStandardTable Returns a standard table from the current project. Alternatively, the GetStandardTable routine can be called from the Lib.dll with the same result. Parameter StdTableFullName The FullName of the standard table to be returned. 1.2.12 PipeClassRootCDevice PipeClassRootCDevice ( ) as IComosDCDevice For internal use. 1.2.13 GetConnectionTypeTable GetConnectionTypeTable ( ByVal ConLayer as String ) as IComosDStandardTable 8 Programming Manual, 04/2014, A5E32035508-AA

Parameter ConLayer For internal use. 1.2.14 GetPrefixOrSeparatorForClassAndDetailClass GetPrefixOrSeparatorForClassAndDetailClass ( ByVal prefixorseparator as String, ByVal comosobject as IComosBaseObject ) as String Returns the set value for the specified prefix type or delimiter type and for the COMOS object. Refers to the "Prefix and delimiter" mask in the project options. For objects of the type IComosDDocument, only the class of the base object is evaluated. The following applies to objects of the type IComosDDevice or IComosDCDevice: first the detail class is evaluated. If this is empty, the class is evaluated. Parameter prefixorseparator The prefix or delimiter. Permitted values: "LabelPrefix": Prefix "LabelSeparator2": Delimiter (same type) "LabelSeparator1": Delimiter (different type) Parameter comosobject The COMOS object from which the class or detail class is read out. Permitted types: IComosDDocument IComosDDevice IComosDCDevice Example 1: Object with class and without detail class Default in COMOS: Object to be evaluated: "A40 Location, two-level" Object is derived from the "@30 > M00 > A20 > A10 > A40 > A40" base object Class of the object: B; Detail class: Empty Evaluation takes place in the script. The engineering object to be evaluated was first assigned to the parameter "b". Programming Manual, 04/2014, A5E32035508-AA 9

Evaluation for: Prefix GetPrefixOrSeparatorForClassAndDetailClass("LabelPrefix", b) Result: "+" Evaluation for: Delimiter (different type) GetPrefixOrSeparatorForClassAndDetailClass("LabelSeparator1", b) Result: "+" Evaluation for: Delimiter (same type) GetPrefixOrSeparatorForClassAndDetailClass("LabelSeparator2", b) Result: "." Example 2: Object with class and detail class Default in COMOS: Object to be evaluated: "A10 Cabinet" Object is derived from the "@30 > M00 > A40 > A20 > A10 > A40 > A10 A10" base object Class of the object: B; Detail class: N Evaluation takes place in the script. The engineering object to be evaluated was first assigned to the parameter "b". Evaluation for: Prefix GetPrefixOrSeparatorForClassAndDetailClass("LabelPrefix", b) Result: ( ) Evaluation for: Delimiter (different type) GetPrefixOrSeparatorForClassAndDetailClass("LabelSeparator1", b) Result: (/) Evaluation for: Delimiter (same type) GetPrefixOrSeparatorForClassAndDetailClass("LabelSeparator2", b) Result: ( ) 1.2.15 GetPrefixOrSeparatorByString GetPrefixOrSeparatorByString ( ByVal prefixorseparatorandclass as String ) as String Returns the set value for the specified prefix type or delimiter type. Refers to the "Prefix and delimiter" mask in the project options. 10 Programming Manual, 04/2014, A5E32035508-AA

Parameter String The prefix type or delimiter type including input of the class or detail class in the following format: <LabelPrefix/Separator1/Separator2>Class<ObjectClass> Or <LabelPrefix/Separator1/Separator2>DetailClass<ObjectDetailClass> Example 1: Object with class and without detail class Default in COMOS: Object to be evaluated: "A40 Location, two-level" Object is derived from the "@30 > M00 > A20 > A10 > A40 > A40" base object Class of the object: B; Detail class: Empty Evaluation takes place in the script. Evaluation for: Prefix GetPrefixOrSeparatorByString("LabelPrefixClassL") Result: "+" Evaluation for: Delimiter (different type) GetPrefixOrSeparatorByString("LabelSeparator1ClassL") Result: "+" Evaluation for: Delimiter (same type) GetPrefixOrSeparatorByString("LabelSeparator2ClassL") Result: "." Example 2. Object with class and detail class Default in COMOS: Programming Manual, 04/2014, A5E32035508-AA 11

Object to be evaluated: "A10 Cabinet" Object is derived from the "@30 > M00 > A40 > A20 > A10 > A40 > A10 A10" base object Class of the object: B; Detail class: N Evaluation takes place in the script. Evaluation for: Prefix GetPrefixOrSeparatorByString("LabelPrefixDetailClassN") Result: ( ) Evaluation for: Delimiter (different type) GetPrefixOrSeparatorByString("LabelSeparator1DetailClassN") Result: (/) Evaluation for: Delimiter (same type) GetPrefixOrSeparatorByString("LabelSeparator2DetailClassN") Result: ( ) See also GetPrefixOrSeparatorForClassAndDetailClass (Page 9) 1.2.16 GetPrefixOrSeparatorByStringAndProject GetPrefixOrSeparatorByStringAndProject ( ByVal prefixorseparatorandclass as String, ByVal project as IComosDProject ) as String Works in a similar way to GetPrefixOrSeparatorForClassAndDetailClass, but delivers values from the specified project. See chapter GetPrefixOrSeparatorForClassAndDetailClass (Page 9). Parameter prefixorseparatorandclass The prefix or delimiter. Permitted values: "LabelPrefix": Prefix "LabelSeparator2": Delimiter (same type) "LabelSeparator1": Delimiter (different type) Parameter project The project from which the values are to be read out. 1.2.17 GetOptions GetOptions ( ByVal optcode as Long ) as Variant Returns a set of related project options. Currently supported: Parameters from the PQM range. Currently supported: PO_M65_DDM_GRP(217) 12 Programming Manual, 04/2014, A5E32035508-AA