Aligning Parallelism of Rolls Has Never Been Faster. L-732 Precision Dual-Scan Roll Alignment System

Similar documents
Single-Axis Lasers for Flatness and Leveling Applications. Laser Systems for Flatness and Leveling L-730/L-740 Series

Aligning Continuous Casters and Steel Mill Rolls

Machine Tool Alignment Boring Mills, Gantries, Machining Centers, VTLs

Laser Systems for Geometric Alignment L-730/740 Series

Laser Systems for Geometric Alignment L-730/740 Series

Fast, Easy and Highly Accurate Extruder Alignment. L-705 Laser Borescope Alignment System for Extruders

S-650 Coupling Alignment System

STEALTH SERIES SHAFT ALIGNMENT SYSTEMS

High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any

High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any

STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S T W I R E L E S S 5 - A X I S

Stealth SerieS. Shaft alignment SyStemS S-660CRT & S-660T WIRELESS 3-AXIS

STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S - 670CRT & S - 670T W I R E L E S S 3 - A X I S

Bore Alignment. Extruder Alignment. Application Notes

Stealth SerieS. Shaft alignment SyStemS S-680BT WIRELESS 5-AXIS

Stealth SerieS. Shaft alignment SyStemS S-680T WIRELESS 5-AXIS

STEALTH SERIES TM S T WIRELESS 5 -AXIS SHAFT ALIGNMENT SYSTEMS

Geometry Measurements

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

Agilent 10706B High Stability Plane Mirror Interferometer

O T Auto-Aligning Straight Line Laser System.

Cross Line Laser kit. User Manual for EK-226P

EI- Shaft Alignment System

E950 BORE ALIGNMENT. Straightness measurement of bore and bearing journals HIGH PRECISION WARRANTY

A U T O C O L L I M A T O R S

CE 260 SURVEYING CHAPTER 5 THEODOLITES

SP ProLine 30. Straightness Professional Package with IT. Another fine solution by PC /13

XL-80 spares list. Application note. Overview

HV601/HV602 for General Construction

E960 TURBINE ALIGNMENT. Straightness measurement of diaphragms and bearing journals HIGH PRECISION WARRANTY

O T Rotating Laser Target System.

3D Laser Scanner VS1000 User Manual

BENCHMIKE 283 SERIES. Off-Line ID/OD/Wall measurement systems for pipe and tube samples

LSM-500H/501H/503H/506H/512H Laser Scan Micrometer SERIES 544 Non-contact Measuring Units

Leica Rugby 320 SG & 410/420 DG The toughest players on big fields

Up to 50% of all costs related to rotating machinery breakdowns is caused by shaft misalignment

TEL: / FAX:

VERTICAL CONTROL LASER OWNERS MANUAL

E950 BORE ALIGNMENT. New detecto. Straightness measurement of bore and bearing journals HIGH PRECISION WARRANTY

Agilent N1203/4/7C Beam Manipulators and N1206T Adjustment Tool Kit

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

Speed of light E Introduction

Welcome to our world.

Welcome to our world.

ЗАО «БЕРГ АБ», (495) , Intrinsically safe shaft alignment tool with printer

Construction. Product Guide

The world s most versatile pipe laser

Three-Dimensional Laser Scanner. Field Evaluation Specifications

XSLIDE. XSlide Positioning System. Manual and Motorized. Compact Positioning Stage. Long life, precise movement, greater value

PRODUCT INFORMATION Model 1000XP Wide Range Particle Spectrometer (WPS )

Leica Rugby 320 SG & 410/420 DG The toughest players on big fields. Construction Machine Control Agriculture

TriAngle. Electronic Autocollimators for Precise Angle Measurement

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

UNIT IV - Laser and advances in Metrology 2 MARKS

nconstruction nmachine Control nagriculture Leica Rugby 320 SG & 410/420 DG The toughest player on the field

Micro-Radian Instruments, 485 W. Horton Road, Bellingham, WA USA.

BenchMike 283 Series. Off-Line Diameter & Ovality Measurement System. for Wire and Cable Samples

BENCHMIKE 283 SERIES. BETA LaserMike. Off-Line ID/OD/Wall measurement systems for pipe and tube samples

BENCHMIKE PRO NEW. The Industry s leading off-line diameter & ovality measurement system

Welcome to our world.

OPTALIGN smart RS5 The power of precision shaft alignment

OPTALIGN smart RS5 The power of precision shaft alignment

Ra Series Fiber Optic Test Instruments

Mitutoyo General Catalog

BENCHMIKE PRO NEW. The Industry s leading off-line ID/OD/Wall measurement system

Vertical angle calibration of a theodolite

Parallel Roll Alignment Software

E D I T I O N PRODUCT LIST SURVEY PRODUCTS LTD

Binoculars. with. Digital Compass. Instruction Manual. Model: Lit. #: /08-12

Centralite CT Moving Laser Patient Positioning System (MRR-1)

A NEW LASER FOCUS ON PATIENT SAFETY

Welcome to our world.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

COMPACT PRECISION LINEAR MOTORIZED ACTUATORS LSMA Series LSMA-173

Straightness measurement

IS-3000-LS-ABB INFRARED SCANNER

SHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH

Rugged and waterproof, plus high-power telescope with superior Nikon optics

SURVEY AND ALIGNMENT OVERVIEW: FERMILAB MAIN INJECTOR RING

Total Station & Distomat

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

E710 / E720. Machine Alignment and Installation THE TOTAL ALIGNMENT SOLUTION. E710 / E720

LBS-532-TL-XX-YYY Brightline PRO (green)

Complete Barrel Measuring and Inspection System. PS Series. User s manual

XT660. Alignment system for all important steps of machine installation. Shaft Alignment

Instructions. Remote Controlled Rotator RCR

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

Measuring systems. Measuring Systems. Hilti. Outperform. Outlast.

Micro-Radian Instruments, 485 W. Horton Road, Bellingham, WA USA. Beam diameter (nominal) Maximum recommended working distance

LAR 350 rotation laser: Tough DUAL SLOPE laser kit Made in Germany. World s first MOTION CONTROL

Measurement and Calibration. TruCheck Models 3 N.m, 10 N.m and 25 N.m. Technical Specification. TruCheck TM

Laserlyte Alignment System

FLEXPOINT Laser Modules. Laser Modules For Your Application. laser-components.com

EZ-LEVEL-PRO Advanced Wireless Inclinometer

SHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH

ZED Tunnel Guidance Ltd

Dear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it.

User's Guide. Model Laser Photo Tachometer

Transcription:

Aligning Parallelism of Rolls Has Never Been Faster L-732 Precision Dual-Scan Roll Alignment System

Why the L-732 Roll Alignment System is Better Roll parallelism accuracy of.00018 in/ft (0.015 mm/m) Up to 70% faster than competitive systems Auto rotating laser planes 200 (30.5 m) measuring range Longer range, fewer setups Multiple wireless targets reduces manpower Very easy to use with minimal training requirements Real-time data displays for measuring and aligning Today s alignment lasers are better, faster and more accurate than any other method for aligning rolls and there is no better laser than our L-742 Ultra-Precision Dual-Scan Roll Alignment System. The system is so easy to use and accurate that you can get the alignment done right the first time, saving significant costs in reduced downtime, scrapped product and quality problems. L-732 More Accurate than Optics With a target electronic resolution of.00002 (0.0005 mm), Hamar Laser s L-742 Roll Alignment System is accurate to +/-.009 (0.23 mm) in 200 (61 meters) under good atmospheric conditions, and that s an honest +/-.009 that everyone can see, not what some optics tech says he sees in his scope. The L-732 alignment results are very repeatable from one operator to the next. 2X Faster and 3X More Accurate than Other Laser Systems Continuously rotating laser planes with multiple wireless targets means the L-732 is 2 times faster than competitive lasers that use manually rotated lasers and pentaprisms to bend the beam. The parallelism accuracy is.00018 in/ft (0.015 mm/m), which is 3 times more accurate than competitive systems that have up to.0005 in/ft. (0.045 mm/m) parallelism error in their laser optics! Multiple Wireless Targets Speeds Alignments up to 70% The L-732 utilizes up to 5 A-1519-2.4ZB targets, with up to 150 feet (45 m) of range, to send their data to our R-1355-2.4 ZB IP67 Rugged PDA Readout. The R-1355 can display up to 5 targets simultaneously, reducing alignment times by up to 70% over optics or other alignment systems. Minimal Training, Less Manpower The L-732 is very similar to using optics but is much easier, so the required training is a lot less. And since the measuring is done at the target, the L-732 reduces alignment manpower because a second operator is not needed to look through the optical scope. Our R-1355 Wireless PDA Readout simultaneously displays both reference targets and the measuring target, allowing the user to quickly set up to the offset centerline reference benchmarks. 100-Foot Vertical Range Reduces Setups The L-732 offers 2 automatically rotating laser planes with range of 100-foot (30.5 m) in radius, vertically and horizontally, which means rolls 100 feet (30.5 m) in the air can be measured without having to move the laser vertically. Few setups, faster alignments!

Innovative Features Designed for Fast, High-Accuracy Roll Alignments Measure More Rolls With Each Setup By using a laser plane, the L-732 has the ability to measure multiple rolls from the same setup. Rolls up to 100 feet (30.5 m) above the laser can easily be measured! Read9 Multi-Target Display Speeds up Laser Transfer The setup process is easy and fast because our Read9 PDA Display program displays up to 5 wireless targets simultaneously, so when using the Laser Transfer Method, you simply look at the data for the 2 reference targets (usually #2 & #3) and adjust the laser until both numbers are the same. Then use the measuring target to measure the roll or rolls. L-732 Measuring Multiple Rolls from 1 Setup Tram Bar Measurement Method For situations where it s impossible to put the target on the side of the roll, we use the Tram Bar Method. Here you put a tram bar over the end of the shaft and put a target on it. Zero at 12:00 and measure at 6:00 to check roll levelness. Then zero at 3:00 and measure 9:00 to get the parallelism relative to the reference roll. L-732 System Features Two continuously rotating laser planes with operational range of 100 (30.5 m) in radius Laser planes flat to.00012 in/ft (0.01 mm/m) Using a reference roll, the measuring laser plane is parallel to roll datum to.00018 in/ft (0.015 mm/m) at any location along the machine Back-lit levels accurate to.00012 in/ft (0.01 mm/m) A-1519-2.4ZB Single-Axis Wireless Target with 1.3 (33 mm) PSD and.00002 (0.0005 mm) resolution R-1355-2.4ZB Wireless PDA displays up to 5 targets simultaneously Factory-built benchmark reference fixtures for easy laser transfers and referencing floor benchmarks L-106 X-Y Tripod Translation Slide to speed up laser transfers and target setup Typical setup time 15 minutes or less R-1355-2.4ZB PDA Readout with laser aligned to reference targets, showing a roll measurement Flexibility to Use Reference Roll or Benchmarks Normally, we recommend using a reference roll as the laser datum reference since cracks in the floor can seriously affect the position of the optical benchmarks and often result in poor alignments. However, the L-732 also offers the flexibility to use the T-1500 Floor Fixtures to pick up the benchmarks if required. A-1519-2.4ZB Target using Tramming Method to measure the parallelism A-1519-2.4ZB Reference Target Mounted on T-1500 Floor Fixture Upgrade to L-733 Triple Scan to Add Leveling Add a third laser plane to the L-732, you get the L-733 Triple Scan laser, which can add flatness, leveling, straightness and squareness to the roll alignment capabilities of the L-732.

Measurement Technology Item HLI L-732 European Systems Optical Theodolites Gyroscope System* Dual Scan Orthogonal Auto-Rotating Planes Manually Rotating Planes + Penta-Prism Optical Square Optical Telescope + Optical Scale High-Accuracy Gyroscopes Speed of Measurement 60-70% faster 30-35% faster 0% faster 60-70% faster Ease of Use Simple, easy setups Complicated, long setups Complicated, long setups Auto Rotating Laser Planes Live Update for Aligning Rolls Laser Plane Flatness & Squareness Roll-to-Roll parallelism measuring accuracy Penta Prism Step Error Easy to use but complicated software Yes, 2 No, manual rotation n/a No Yes Yes Yes Flatness:.00012 in/ft (0.010 mm/m) Squareness:.00018 in/ft (0.015 mm/m).00018 in/ft (0.015 mm/m) +/-.00025 in. (+/-0.006 mm) Las. Flatness: 0.02 mm/m Las. Sqrness: 0.01 mm/m Pent. Flatness: 0.02 mm/m Pent. Sqrness: 0.01 mm/m.00048 in/ft (0.040 mm/m) (Total accuracy: las. + penta) Not specified Not specified No. Report only! Must use another alignment tool to align. n/a Accuracy not specified. Resolution: 0.008 mm/m 1.0 mm** n/a n/a Tripods Required 1 2 1 0 Resolution of Measurement.00002 in. (0.0005 mm).00004 in. (0.001 mm).0010 in. (0.025 mm).00005 in/ft (0.004 mm/m) Detector PSD Size 33x12 mm 20x20 mm n/a n/a Operating Range 100 feet (30 m) in Radius Not specified 100 feet (30 m) Not specified Software Required? No Yes No Yes Manpower Required to Run System HLI vs. the Competition 1 optical technician 2 optical technicians 2 optical technicians 1 service engineer * Gyroscopes not available for purchase. Service only. ** European systems do not calibrate Penta Prism centering, a source of large errors. Parallelism Accuracy: HLI s L-732 Dual Scan Technology vs. The Competitor s Pentaprism HLI s Laser Transfer Method Competitor s Pentaprism Method L-742 Dual Scan Roll Alignment System 2 When using HLI s Laser-Transfer Method and a reference roll, the squareness between the L-742 s laser planes is effectively eliminated when moving the laser from section to section. This means the measuring laser plane is parallel to where it was upon the initial setup to within the combined flatness of the laser planes or.00018 in/ft (0.015 mm/m)! 3 1 1 0.03 mm/m Plane Flatness/Squareness 2 0.015 mm/m Plane Squareness 3 (1) - (2) = 0.015 mm/m Parallelism Error since Squareness Error Does Not Add in! 4 0.02 mm/m Beam Squareness/Flatness 5 0.02 mm/m Beam Squareness/Flatness 6 (4) + (5) = 0.040 mm/m Parallelism Error Between 2 Beams! 7 Additional Step Error of up to 1.0 mm 7 5 Competitor Beam-Bending Roll Alignment Systems When using the Pentaprism Method with a reference roll, after the Pentaprism is moved to another location along the machine, the laser beam at the second location will not be parallel to the laser at the reference roll by up to.0005 in/ft (0.040 mm/m). Not very good for 3-7 meter rolls! Furthermore, rotating the prism to reach and upper or lower roll could result in an additional error of up to.040 (1.0 mm). 6 4

How L-732 Works for Roll Alignment Here s how the process works for using a reference roll as the laser datum to measure rolls for parallelism to the reference roll. 1. The L-732 is placed on the L-106 stand outside the machine near the reference roll at the side of the machine and leveled. L-732 mounted on L-106 with Target #1 about to be aligned to the reference roll 2. A-1519-2.4ZB Target #1 is placed on the reference roll horizontally at the closest point to laser, is leveled and zeroed in Read9 PDA software. Target #1 is then moved to the far end of the roll. 5. Since the LP#2 is perpendicular to, LP#2 becomes the offset centerline of the mill. This offset centerline has a range of 100 feet (30.5 meters) on both sides of the laser. LP#2 Offset Centerline L-732 Aligned to Reference Roll 6. Now we place Target #2 & #3, on floor fixtures at both ends of the machine and are adjusted until the laser hits the middle of the target windows. The targets are then zeroed, establishing the offset centerline, and are not touched during the remainder of the alignment. 8. Then the yaw adjustment on the laser base is adjusted to tilt LP#2 until both Target #2 & #3 show the same readings, which means LP#2 is now parallel to the offset centerline. LP#2 Offset Centerline L-732 transferred, aligned to reference targets and ready to measure the roll 9. Now to measure one of the rolls for parallelism, Target #1 is placed horizontally on the roll closest to the laser and zeroed. It is then moved to the far end of the roll to measure the alignment. A +.025 reading means the far end of the roll is pointing to the right relative to the reference roll. L-732 being adjusted to be parallel to reference roll 3. Laser Plane #1 () is then Bucked-in or tilted until Target #1 reads zero at the far point. Target #1 is then moved back to the near point and re-zeroed and the process is repeated until the target reads zero at both locations. L-732 being adjusted to be parallel to reference roll 4. The laser plane is now parallel to the reference roll. Installing #2 & #3 A-1519-2.4ZB Targets with T-1500 Floor Fixture to LP#2 7. To check the parallelism of a section of rolls, the L-732 and L-106 stand are moved along the offset centerline to the desired section and the laser is positioned so is about 4-5 from the roll to be measured. The L-732 is then leveled. LP#2 Offset Centerline L-732 transferred to new location with laser being aligned to reference targets. L-732 measuring roll for alignment. Data shows an error of +.025 (+0.98 mm) so the far end of the roll is angled to the right. 10. With targets producing live readings, the roll can then be adjusted until the target reads zero, which means the roll is aligned and parallel to the reference roll. Since the laser generates a plane, rolls up to 100 feet (30.5 m) in elevation in that section that are within 2 feet (610 mm) of the laser plane can be measured for parallelism without changing the setup of the laser. L-732 Aligned to reference targets measuring multiple rolls from the same setup.

Specifications L-732 Dual-Scan Roll Alignment System Weight Material Laser Type Beam Power Beam Stability Laser Plane Flatness Beam/Plane Operating Range Operating Modes Power Supply Power Draw Adjustment Range Adjustment Resolution Laser: 3 lbs. (1.3 kg) Base: 4.8 lbs. (2.2 kg) Battery Pack: 1 lb. (0.45 kg) Laser: Aluminum and stainless steel Base: Aluminum Class II visible diode, 635 nm wavelength (class 1 in Scanning Mode); 0.160 (4.06 mm) beam diameter 0.9 mw per straight beam.0001 /hr/ F (0.005 mm/hr/ C) translational 0.2 arc sec./hr/ F (0.36 arc sec/hr/ C) angular 180/360 Sweep: 2.0 arc sec (.00012 in/ft or 0.01 mm/m), plus translational error of ±.00025 (0.006 mm) 90 Sweep: 1.0 arc sec (.00006 in/ft or 0.005 mm/m), plus translational error of ±.00013 (0.003 mm) Left-to-Back Plane squareness 3 arc secs (.00018 in/ft or 0.015 mm/m); 100 feet (30.5 m) in radius 2 beams or 1 or 2 continuously rotating laser planes in any combination, individually switched 9V DC external battery pack (4 cells) or 115V AC adapter (See chart, below) ± 3 degrees.01 (0.25 mm) in 100 feet (30.5 meters) A-1519 Wireless Target Resolution Linearized Accuracy Detector Size/ Type Operating Range Target Angle Acceptance Range Battery Life Operating Temperature Power Supply Size Weight Wireless Range Magnetic Base Size Magnetic Base Weight.00002 (0.0005 mm) ±.00015 (±0.0038 mm) over ± 14 mm of PSD 2-Axis PSD 1.3 x 0.51 (33x13 mm) 100 feet (30.5 m) from laser to target ± 10 11.5 hours continuous duty 5 F to 140 F (-15 C to 60 C) 7.5-12vDC, 500mA 2.00 W x 4.11 H x 1.75 D (50.8 mm x 104.4 mm x 44.5 mm) 13.5 oz. (383 grams) 150 feet (46 m)* 2.00 W x 3.09 H x 4.14 D (50.8 mm x 78.5 mm x 105.2 mm) 2.78 lb. (1.26 Kg) * Wireless range may be limited by obstructions, antenna type and orientation. Outdoors line-of-sight range, with dipole antenna, may be greater. 2.25 (57.1 mm) 2.15 (54.6 mm) 4.26 (108.2 mm) 4.57 (116 mm) 7.30 5.22 2.06 (52.3 mm) 5.92 1.00 (25.4 mm) 3.73 7.30 7.30 5.62 3.54 SQUARE 5.62 Hamar Laser Instruments, Inc. 5 Ye Olde Road, Danbury, CT 06810 Phone: +1-203.730.4600 Fax: +1.203.730.4611 Int l: +1.203.730.4600 E-mail: sales@hamarlaser.com www.hamarlaser.com U.S. and foreign patented and/or patents pending. Made in the USA. 2017 Hamar Laser Instruments, Inc (4/17)