SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].

Similar documents
SECTION PANELBOARDS

Rolling Shutters - 3 Part Specs

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

PROJECTOR LIFTS CUSTOM E-CATALOG draperinc.com/av

Technical Data Sheet Excel 741

Addendum # 2. Bid # Scoreboards (Softball Baseball Soccer) Addition Specification on Softball and Baseball

Webb Core Cleanroom Wall System

ROLLING COUNTER SHUTTERS

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

Product Guide Specification

Product Guide Specification

SECTION [13200] FRAMED 2000 CLEANROOM WALL SYSTEM

Product Guide Specification

Ideal protection for your electrics: häwa cable ducts

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Installation Instructions Access Dual Roller FlexShade System by Draper

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

LEE DAN COMMUNICATIONS, INC.

SECTION MODEL 2577 INDOOR SCOREBOARD. A. Single-face electronic scoreboard and control console for indoor use.

FLEXBOX. Installation Guide

SU500: 12.5 (318 mm) SU500CL: (438 mm) SU500: 39 (991 mm) SU500CL: 37.5 (953 mm) SU500: 3.5 (89 mm) SU500CL: 3.0 (76 mm)

Product Guide Specification

SECTION SWITCHGEAR

LEE DAN COMMUNICATIONS, INC.

Governing Standards. All wiring and components shall meet the applicable requirements of the NEC.

Wireless Enclosures from Wiremold/Legrand

Vertiv VR Rack 1.0 GENERAL

LEE DAN COMMUNICATIONS, INC.

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

Linear Luminaire with LED Series 6012/5

Product Guide Specification

F O R U M S E R I E S

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

SECTION MODEL INDOOR SCOREBOARD. A. Four-face electronic scoreboard and control console for indoor use.

Brasch Washdown Unit Heaters

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Physical security. Ideal mounting orientation. Simplify moves, adds, and changes. Designed to Protect Your Motorola Networks Investment

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

1510 MOTOR CONTROLLERS

Linear Luminaire with LED Series 6412/5

Computer Network Design Guide Existing Systems 1 / 6

Diffuser Color (when not illuminated) Light amber hue

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

ClearPix Screen In Ceiling Casing Installation Manual Slot Version

SUPER LEDF10HP DATASHEET

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

4C Standard Horizontal Mailboxes

Series 062 Bus Bar Connectors

Product Guide Specification

ClearPix Motorized Screen In-Ceiling Casing Slot Version Installation Manual. Revision G

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

SUPER LEDF6 DATASHEET

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications

IPR-150 INSTALLATION GUIDE 150KVA Three-Phase Release 1.0

Level-Lance Model 5400A

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

AIR SERIES Thinnest, most versatile, linear lighting

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR MICROWAVE VEHICLE DETECTION SYSTEM

4C Standard Horizontal Mailboxes - continued on pages 14-17

Wireless Wall Switch Guide

Suggested Functional Specifications for a GPS-Synchronized Clock System using Network Time Protocol and Power over Ethernet

PROLINE ExtERNaL COmPONENts 0-mm solid BasE Catalog Number Fits Frame B x C W (mm) W (in.) D (mm) D (in.) PB045 PB046 PB064 PB064HF2 PB065HF2 PB066

BETTER VALUE BETTER OPTIONS BETTER LIGHTING

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC.

Caution: Beware of pinch points. Important Safety/Installation/Operating Instructions. Caution:

SECTION A. Tempered Glass Free Standing Swing Gate Post Assemblies.

Installation/ Operation Manual

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

Product Guide Specification

BETTER VALUE BETTER OPTIONS BETTER LIGHTING

IVR15-SPI 1.5 Solid State Illuminated Rail 2 Post Integral Power Supply

SECTION DISCONNECT SWITCHES

CALIBER LIGHTING. SERIES 6VTW-NF Flush Mount LED Tunable White Recessed Downlight, 1613 Lumen APPLICATION PRODUCT DATA. 6VLED Example: 6VLEDSCLNF

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

Lineal SPECIFICATIONS: LED Luminaire STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

4C Std Horizontal Mailboxes - cont. on pgs 14-19

2.7 UNDER-CARPET WIREWAY

Full HD Speed Dome IP Camera

JAN 16 Rev B

SECTION BUILT-IN KEY-OPERATED LOCKS

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS

PowerFlex 400 AC Drive Guide Specification

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

SONY SECURITY SYSTEMS MOTORIZED HIGH SPEED DOME CAMERA SYSTEM U S P E A C E S N H I

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

The VoiceArrest System

Aluminum Mailboxes - Standard System

Product Guide Specification

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Titan Cable Management Catalog TCM3.0. IMS Engineered Products is ISO 9001 Certified. Designed and Manufactured in the USA

Transcription:

(Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying AeroLift motorized projector lifts and their installation. The Specifier needs to edit these guide specifications to fit the needs of each specific project. References have been made within the text of the specification to MasterFormat section numbers and titles. The Specifier needs to coordinate these numbers and titles with sections included for the specific project. Throughout the guide specification, there are Specifier Notes to assist in the editing of the file. Desired options for motors, enclosures and controls need to be noted. Brackets have been used to indicate when a selection is required. Unless noted otherwise, the first option is the standard feature. Contact a Draper, Inc. representative for further assistance with appropriate product selections. Projector equipment should be chosen during the planning stages of a project to ensure desired mounting and functions can be achieved. An AV consultant or expert should be involved whenever possible. Coordinate projector specifications with motorized projector lift capabilities.) SECTION 11 52 36 PROJECTOR LIFTS AND MOUNTS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Motorized projector lifts. 1.2 ACTION SUBMITTALS A. Refer to Section [01 33 00 Submittal Procedures] [Insert section number and title]. B. Product Data: For each type of lift, including manufacturer recommended installation procedures. C. Shop Drawings: Include dimensions, method of attachment, structural support, [bracing,] and electrical wiring. D. Samples: Provide finish samples. 1.3 CLOSEOUT SUBMITTALS A. Refer to Section [01 78 00 Closeout Submittals] [Insert section number and title]. B. Maintenance data. Project Name/Project Number/14-Sep-10 11 52 36-1 PROJECTOR LIFTS AND MOUNTS

1.4 QUALITY ASSURANCE A. Source limitation: Obtain motorized projector lifts from single manufacturer as a complete unit including necessary mounting hardware and accessories. B. Motors for projector lifts shall be certified for use in the United States and Canada by Underwriters Laboratory (UL), Inc. and shall bear UL label. (Specifier Note: Suspended projector lifts may require bracing to resist seismic loads depending on weight, project location, and installation details. Suspension rods, bracing, and other support components are not provided by Draper and will need to be designed for specific applications, detailed on drawings, and specified in other sections. DELETE seismic bracing paragraph below if not project specific.) C. Seismic Bracing: Motorized projector lift suspension components and method of installation shall comply with requirements for Seismic Zone [1] [2A] [2B] [3] [4]. 1.5 DELIVERY, STORAGE AND HANDLING A. Refer to Section [01 60 00 Product Requirements] [Insert section number and title]. B. Deliver motorized projector lifts in manufacturer s original, unopened, undamaged containers with identification labels intact. (Specifier Note: Draper, Inc. does not warrant against freight damage, concealed or otherwise. RETAIN inspection and storage paragraphs below for all projects.) C. Inspect motorized projector lifts for freight damage, concealed or otherwise, upon delivery to project site. Report damage to freight carrier immediately for replacement of motorized projector lifts. D. Store motorized projector lifts in resealed manufacturer s original containers. PART 2 - PRODUCTS (Specifier Note: Product information is proprietary to Draper, Inc. If additional products are required for competitive procurement, contact Draper, Inc. for assistance in listing competitive products that may be available.) 2.1 MANUFACTURER A. Draper, Inc.; 411 South Pearl Street; Spiceland, IN 47385-0425; Phone 765.987.7999; website www.draperinc.com 1. Subject to compliance with requirements, manufacturers of products of equivalent design may be acceptable if approved in accordance with [Section 01 25 00 Substitution Procedures] [Insert section number and title]. Project Name/Project Number/14-Sep-10 11 52 36-2 PROJECTOR LIFTS AND MOUNTS

2.2 MOTORIZED PROJECTOR LIFTS A. Electrically Operated, Low Profile Lifts: Electrically operated, ceiling recessed projector lift for lowering and retracting projector for operation and storage. Assembly to include controls, mounting hardware, wiring, and other components required for complete operation. (Specifier Note: Model specified depends on the maximum capacity of lift desired. SELECT AeroLift 25 for 25 lbs (11 kg), AeroLift 50 for 50 lbs (23 kg), or AeroLift 150 for 150 lbs (68 kg).) 1. Basis-of-Design Product: AeroLift [25] [50] [150]. a. Limit Switches: Provide factory set and field adjustable. (Specifier Note: COORDINATE maximum extension with specified basis-of-design. SELECT 20 inches (508 mm) for AeroLift 25, or 32 inches (813 mm) for AeroLift 50 and AeroLift 150.) b. Maximum Extension: [20 inches (508 mm)] [32 inches (813 mm)]. (Specifier Note: COORDINATE maximum lift capacity with specified basis-of-design. SELECT 25 lbs (11 kg) for AeroLift 25, 50 lbs (23 kg) for AeroLift 50 or 150 lbs (68 kg) for AeroLift 150.) c. Maximum Lift Capacity: [25 lbs (11 kg)] [50 lbs (23 kg)] [150 lbs (68 kg)]. (Specifier Note: COORDINATE travel speed with specified basis-of-design. SELECT 14 for AeroLift 25, 23 for AeroLift 50 or 150 for AeroLift 150.) d. Approximate Travel Speed: [14] [23] seconds. B. Operating Mechanism: Operating pan raised and lowered by 110 VAC, 60 HZ, instantly reversible, thermally protected, lifetime lubricated, tubular 3-wire motor and cloth system with scissor arm for stability. (Specifier Note: COORDINATE pan size with specified basis-of-design model. SELECT 22-1/4 by 14 inch (565 by 356 mm) for AeroLift 25, 28-1/4 by 15 inch (718 by 381 mm) for AeroLift 50 or 31-1/4 by 15-7/8 inch (794 by 403 mm) for AeroLift 150.) C. Operating Pan: [22-1/4 by 14 inch (565 by 356 mm)] [28-1/4 by 15 inch (718 by 381 mm)] [31-1/4 by 15-7/8 inch (794 by 403 mm)], steel pan with black powder coat paint finish for attachment of suspended projector. (Specifier Note: SELECT one of three projector attachment options below. 1. Projector Attachment: [Bolted to operating pan] [Mounted to operating pan with brackets provided by projector manufacturer] [Mounted to operating pan with universal projector mount]. (Specifier Note: DELETE universal projector mount if not specified in projector attachment paragraph above.) a. Universal Projector Mount: Universal bracket suitable for projectors up to 26 lbs (12 kg) with adjustable arms that can be manipulated to fit most projectors with three or four mounting holes. Tilt, yaw and pan adjustments can be made quickly using spring-loaded bolts. Project Name/Project Number/14-Sep-10 11 52 36-3 PROJECTOR LIFTS AND MOUNTS

1) Basis-of-Design Product: Universal Projector Mount as manufactured by Draper, Inc. (Specifier Note: Optional ceiling closure panel is suspended below projector and is recessed to accept an acoustical ceiling panel or mounted flush with ceiling. SELECT desired option below or DELETE ceiling closure paragraph and sub-paragraphs below if not project specific.) D. Ceiling Closure Panel: Steel closure panel suspended below projector from rods attached to operating pan. Closure [mounted with recess to allow attachment of acoustical ceiling panels] [mounted flush with adjacent ceiling surface and finished with white powder coat paint finish]. a. Trim: Metal trim ring to finish ceiling opening. (Specifier Note: COORDINATE ceiling closure size with specified basis-of-design.) b. Size: [Small AeroLift 25 Closure, 15-5/8 by 25 inches (397 by 635 mm)] [Large AeroLift 25 Closure, 25 by 25 inches (635 by 635 mm)] [AeroLift 50 Closure, 30-3/4 by 30-3/4 inches (781 by 781 mm)] [AeroLift 150 Closure, 40-3/4 by 30-1/4 inches (1035 by 768 mm)] (Specifier Note: Optional environmental airspace housing isolates projector from environmental airspace above the ceiling. COORDINATE environmental airspace housing size with specified basis-of-design. DELETE paragraph below if not project specific.) E. Environmental Airspace Housing: Fabricated from aluminum and steel panels for recessing projector lift in ceiling space used as return air plenum. Provide with universal closure and metal trim to finish ceiling opening. 1. Size: [Small AeroLift 25 Housing, 14-9/16 by 23-7/8 inches (370 by 606 mm)] [Large AeroLift 25 Housing, 23-1/2 by 23-1/2 inches (597 by 597 mm)] [AeroLift 50 Housing, 29-3/8 by 30-1/2 inches (746 by 775 mm)] [AeroLift 150 Housing, 39-5/8 by 30-1/4 inches (1007 by 768 mm)]. (Specifier Note: Optional ceiling access door in paragraph below provides access to projector and lift for cleaning, maintenance or repairs when unit is installed above a hard ceiling. DELETE paragraph if not project specific.) F. Ceiling Access Door: Provide 24 by 24 inch (610 by 610 mm) hinged ceiling access door [with white finish] [recessed to accept ceiling tile] installed to allow access to projector and mount installed above ceiling. 2.3 CONTROLS A. Provide [1] [2] [3] [4] control stations to lower, raise, and stop projector lift. (Specifier Note: SELECT one of two control paragraphs and corresponding sub-paragraphs below. DELETE paragraph that is not project specific.) OR B. Single Station Control: 3-position 110-120V maintained rocker switch with [stainless steel cover plate and black rocker] [white switches]. Project Name/Project Number/14-Sep-10 11 52 36-4 PROJECTOR LIFTS AND MOUNTS

(Specifier Note: Optional low voltage controls allow motorized projector lifts to be controlled from multiple locations using two or more low voltage switches. Low voltage controls can be provided with 3 button switches, or without switches as interface with a master control system, a radio frequency remote control receiver, or an infrared remote control receiver. SELECT desired options in paragraph below.) C. Low Voltage Station Control: Control station [with 3 button switches for up, down and stop functions] [without switches for interface with [master control system] [radio frequency remote control receiver] [infrared remote control receiver]]. Wiring from switches or receivers to low voltage control unit to be 24 V. (Specifier Note: SELECT one of two portable, remote control hand held transmitter and receiver paragraphs below. Radio frequency and infrared remote control receivers need to be provided with and connected to a single low voltage control unit. COORDINATE paragraph with options in low voltage control paragraph above. DELETE paragraphs that are not project specific.) OR 1. Radio Frequency Remote Control: Hand held 3 button control for up, down, and stop functions and receiver unit to connect to low voltage control unit. 2. Infrared Remote Control: Hand held 3 button control for up, down, and stop functions and receiver unit to connect to low voltage control unit. Unit compatible with learnable infrared master control systems. (Specifier Note: Optional key operated power supply switches limit access to projector mount controls during specified time periods. COORDINATE options below with control paragraphs above.) D. Key Operated Power Supply Switch: Key operated switch to control [low voltage] [110 V] power to mount operating [switch] [radio frequency remote control receiver] [infrared remote control receiver]. Provide with [2] [insert number] keys. (Specifier Note: Optional video interface controls (VICs) replace standard single-station control switches and allow motorized lifts and screens to be controlled by a single switch or remote control. VICs first descend the projector mount and then the screen. SELECT Model VIC6 to integrate mount and screen operation with 6V switched outlet, Model VIC12 to integrate with 12V or Model VIC115 to integrate with 110V. SELECT override switch option if independent operation of mount and screen are desired.) E. Video Interface Control: Interface to allow motorized lift to be controlled simultaneously with video projector with 12V outputs and motorized screen through [6] [12] [110]V switched outlet. [Equip interface with override switch permitting independent operation of mount and screen.] 1. Basis-of-Design Product: Model [VIC6] [VIC12] [VIC115] as manufactured by Draper, Inc. PART 3 - EXECUTION (Specifier Note: Motorized projector lifts can be mounted on ceiling surface or recessed into ceiling space. COORDINATE requirements with desired installation.) Project Name/Project Number/14-Sep-10 11 52 36-5 PROJECTOR LIFTS AND MOUNTS

3.1 PREPARATION A. Coordinate layout and installation of motorized projector lifts with ceiling construction and related components penetrating or above ceilings such as lighting fixtures, mechanical equipment, ductwork, and fire-suppression system. B. Coordinate requirements for blocking, structural supports, bracing, and ceiling openings to ensure proper installation of motorized projector lifts. C. Coordinate location and requirements for power supply conduit, and wiring required for motorized projector lifts and controls. D. Coordinate installation of recessed motorized projector lifts with construction of suspended [acoustical panel ceilings specified in Section 09 51 13 Acoustical Panel Ceilings] [gypsum board ceilings specified in Section 09 29 00 Gypsum Board]. (Specifier Note: DELETE coordination paragraph for acoustical ceiling panels adhered to closure panels if not project specific.) E. Coordinate required tolerances and weight restrictions for acoustical ceiling panels adhered to mount closure. (Specifier Note: DELETE motorized screen coordination paragraph below if interface of controls for motorized projector lift and motorized screen are not project specific.) F. Coordinate interface and installation of motorized projector lift controls with provision of motorized screen. 3.2 INSTALLATION A. Install motorized projector lifts and controls at locations and heights indicated on Drawings. B. Install motorized projector lifts complete with necessary hardware, anchors, brackets and fasteners; according to manufacturer's written instructions and as specified. 3.3 TESTING AND DEMONSTRATION A. Test motorized projector lifts to verify that lifts, controls, limit switches, closures, and other operating components are functional. Correct deficiencies. B. Demonstrate operation of motorized projector lifts to Owner's designated representatives. 3.4 PROTECTING A. Protect motorized projector lifts after installation from damage during construction operations. If damage occurs, remove and replace damaged components or entire unit as required to provide units in their original, undamaged condition. END OF SECTION Project Name/Project Number/14-Sep-10 11 52 36-6 PROJECTOR LIFTS AND MOUNTS