Power Products. Factory-approved power sources for Isco Samplers and Flow Meters Batteries AC Power Packs Chargers

Similar documents
ma Input Module. Installation and Operation Guide

Latching, Sequence and Impulse Relays Application Data

Model HM-535 Power Supply Installation and Service Instructions

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG.

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

I SCO 4100 SERIES F LOW L OGGERS The Ultimate System for Multi-Site Flow Monitoring and Analysis

Diagram 1 - Current Accuracy Test Setup

Andover Continuum. Power Supplies with or without UPS

Model 720 Electromechanical Hour Meter

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

Product Specifications

1640 Liquid Level Actuator. Installation and Operation Guide

Bulletin 871D Cylinder Position Inductive Style

Integrated AC Traction & DC Pump System Controller Model 1298

FBT-10. Fieldbus Commissioning Box. User Manual FBT-10 User Manual Rev A.0

Chapter 5 Review. Power Supplies

Portable Refrigerated Portable Refrigerated. Sampler Source Book

TR-3000 STORM WATER SAMPLER MANUAL OF OPERATION.

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

Using the AUX Port on the Conext XW+ to Connect to a Generator or the Grid

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1

Innovative Circuit Technology Ltd.

7-Port Charging Station for USB Devices

Catalyst. Your all-in-one data logging and remote monitoring solution

Pulse Doppler. Insertion Flow Meter. True In-situ Velocity Profiling

DCT7088 Portable Digital Correlation Transit Time Flowmeter

INSTRUCTION MANUAL MODELS: 1760A, 1761, Triple Output DC POWER SUPPLY With Dual 4-Digit LED Displays

Hand-held thermometer Model CTH7000

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

BAC GLOBAL SURVEYOR Mk

EnCell Battery Cell Monitor

TDAS G5 Docking Station Hardware User s Manual

Industrial Power Supplies

MC300. BLN Issued: April 2003

Expandable Power Systems

Hand-held thermometer Model CTH7000

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

2102 Wireless Communication Module. Installation and Operation Guide

Powerware 9315 Hot Sync Parallel Capacity System Bypass Module (SBM)

PRODUCT. Battery Charger

PS-4100 POWER SUPPLY MANUAL

DEEP SEA ELECTRONICS PLC

Compact plugs and receptacles standard or high temperature rated

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

SBS-S SERIES DC LOAD BANK USER MANUAL Rev

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Industrial Power Supplies

SmartPro UPS System Intelligent line interactive medical-grade battery backup and network power management

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install

IVC-222HPII Precision Voltage/Current Calibrator

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL

UPS Emergency Bed Power Unit

THOR Battery Backed DC Power Supply Reference Manual

AC ADAPTERS 25W SWITCHING POWER SUPPLY - CLOSED FRAME 60W SWITCHING POWER SUPPLY - CLOSED FRAME

Innovative Circuit Technology Ltd.

ma Input Module. Installation and Operation Guide

Item 4. June 17, 2015

2440 Wireless SmartCart

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

Installation Manual for D244X Series 24-volt Power Supplies

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

Amphenol. Printed Circuit Board Technology NAFI + UHD CONNECTORS STANDARD. RELIABLE. PROVEN.

User s Manual. NOVAMETRIX BaseStation for Hand-Held Monitors....simply, the leading edge

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

RHF. Railroad High Frequency Battery Charger. Installation and Operation Manual. La Marche Manufacturing Company

SPECIAL PROJECTS 3800 Hwy 271 North Powderly, TX Phone: Fax: Aqua 20/20 OWNER S MANUAL

RT4F-110V/25A RECTIFIER

ASTRON POWER SUPPLIES HEAVY DUTY HIGH QUALITY RUGGED RELIABLE SPECIAL FEATURES

Solid State Battery Fuel Gauge

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

Commercial/Industrial Circular Connectors

SV 277 Pro User Guide. Assembling the system. What's inside? Before you go on site

EPIC Circular Connectors CIRCON M23 Series

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Inform IT Single Pen Circular Chart Recorder

Wireless 0-1 ma Current Meter

7-Port USB 3.0 Hub - Desktop or Wall-Mountable Metal Enclosure

Contents 1 Warnings, Cautions, and Notes Description Features... 1

LIVE C.T. ADMITTANCE TESTER 505B DATASHEET REDPHASE INSTRUMENTS

SmartOnline 208/240V 10kVA 9kW Double- Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA

Installing Sentor. Hardware Installation

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Isobar Surge Suppressors by Tripp-Lite (Most Popular Models)

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Intelligent Solar Charge Controller User s Manual. Please read this manual carefully before you use this product

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

Transcription:

Power Products Factory-approved power sources for Isco Samplers and Flow Meters Batteries AC Power Packs Chargers Genuine Isco Power Products ensure best performance and compliance with product warranty conditions.

Contents Batteries Lead-Acid Models 945, 946, 947, 948... 2 Nickel-Cadmium Model 934...1 Power Packs Battery-backed Models 914, 924...4 Hi-capacity Models 913, 923... 3 Chargers 6-Amp Clamp-on Charger... 6 Five-station Charger Model 965... 5 Solar Charging Information... 6 Wall-mount Chargers Models 961, 963... 5 Charger/Battery Compatibility Chart... Rear Cover Nickel-Cadmium Battery Our Nickel-Cadmium Battery is your best choice where a portable power source is needed in continuous-use applications. It allows more charging cycles than Lead-acid batteries, and isn't damaged by overcharging or being left totally discharged for extended periods. Maintenance Free Isco Nickel-Cadmium Batteries are totally sealed to allow worry-free transport and operation. Ruggedly Built The hardened case is made to withstand the rigors of field use. Heavyweight cables and military-grade connectors assure durability and long life. Temperature Tolerant Output from lead-acid batteries drops substantially at temperatures below 32 F (0 C), but Isco Nickel- Cadmium Batteries are unaffected to -4 F (-20 C). Model 934 Isco Part #60-1684-040 934 Isco Samplers, Flow Meters, and Portable Pumps when used at regularly-serviced monitoring sites Output Voltage 12-14V DC Amp/Hour Rating 4.0 Connector Type 2-pin Circular Amphenol 1

Lead-Acid Batteries Isco Lead-Acid Batteries are best wherever portable standby power is required. They have a very low self-discharge rate and outperform Ni-Cad batteries in applications where battery power is used sporadically over long periods of time. All are environmentally sealed and maintenance-free. Fluid level checks and refilling are not required. Model 945 Isco Part No. 60-2004-041 A rechargeable* lantern-style battery. For use in our 2191 Battery Module. *Use Isco Lantern Battery Charger Adapter Part #60-2004-040 (not shown). Model 946 Isco Part No. 60-3004-106 Proven in decades of service. The industry standard in lead-acid batteries. Model 947 Isco Part No. 60-3114-011 Designed and built exclusively for use in Isco 4100 Series Flow Loggers. Model 948 Isco Part No. 608-3000-948 This gelled-electrolyte automotive style battery delivers 45 Amp-hours (about seven times that of the Model 946). at 12 volts DC. Includes protective case and instrument connection cable. Sites with intermittent or sporadic activity - stormwater runoff monitoring, inflow & infiltration (I&I) studies, combined sewer overflow (CSO) monitoring, etc. 945 946 947 948 Output Voltage 6V DC 11-13.5V DC 11-13.5V DC 12V DC Amp/Hour Rating 5.0 6.5 6.5 45 Connector Type Coiled 2-pin Circular 4-pin Circular 2-pin Circular Wire Amphenol Amphenol 2

High-capacity Power Packs Our rugged, High capacity Power Packs safely and reliably convert available AC voltage to DC power. Not battery-backed. Intended for use only where a reliable AC power source exists. Built-in Battery Charger Use the Power Pack to charge a battery while it supplies DC current to your equipment. Environmentally Sealed From the case and connectors to the electronics, Isco Power Packs withstand the harshest conditions. Model 913 Isco Part #60-1684-088 UL and cul listed. Model 923 Isco Part #60-3004-190 913 923 Fixed Installations and/or sites with reliable AC power Input 120V AC 240V AC Voltage 50 or 60 Hz 50 or 60 Hz Output Voltage/ 12.5V DC @ 5A 12.5V DC @ 5A Current Connector 2-pin Circular 2-pin Circular Type Amphenol Amphenol 3

Battery-backed Power Packs Isco Battery-backed Power Packs assure that your equipment will keep running if AC line voltage is interrupted. Battery Backup The built-in 1.2 AHr nickel-cadmium battery runs your equipment if AC power is interrupted. Benchmark Reliability Our field-proven design assures dependable operation for years to come. Model 914 Isco Part #60-3004-130 UL and cul listed. Model 924 Isco Part #60-3004-160 914 924 Fixed installations and/or sites with available AC power Sites with an unreliable AC power supply Input 120V AC 240V AC Voltage 50 or 60 Hz 50 or 60 Hz Output 12-14.5V DC 12-14.5V DC Voltage/ 3A continuous, 3A continuous, Current 5A maximum 5A maximum Connector 2-pin Circular 2-pin Circular Type Amphenol Amphenol 4

Chargers with Amphenol Connectors Economical and Durable Wall-mounts A low-cost method for charging single Isco batteries. An impact-resistant case and solid-state construction make these chargers almost indestructible. Model 961 Isco Part #60-3004-059 This charger efficiently charges a single Isco Model 934 nickel-cadmium battery. Model 963 Isco Part #68-3004-198 Intended for use with Isco lead-acid batteries only. UL Listed. Automatic Temperature Compensation Temperature-compensated, fan-cooled electronics automatically adjust to assure accurate charging. Rugged Design A tough metal case and sturdy connectors deliver reliable performance and long life under demanding conditions. Model 965 Isco Part # 68-3000-965 Charges up to five batteries at one time. By simply flipping a switch, you can charge either nickel-cadmium or lead-acid batteries. UL Listed. 961 963 965 Input Voltage 120V AC @ 60 Hz* 120V AC @ 60 Hz 120V AC @ 60 Hz or 240V AC @ 50 Hz or 240V AC @ 50 Hz Output Voltage 14.5V DC @ 400 ma* 13.7V DC @ 720 ma 13V DC @ 400 ma 14.9V DC @ 800 ma Connector Type 2-pin Circular Amphenol 5 * Contact factory for 240V AC 50 Hz input voltage.

Clamp-on Style 12V Charger Fully Automatic This unit constantly monitors 12 volt/6 Amp charge status, shuts down when charging is complete, and gives notification via LED. Polarity Protection Special circuitry prevents charger or battery damage if improperly connected. 12 Volt, 6 Amp Isco Part #68-3004-198 Specifically compatible with Isco Model 948 Batteries. UL listed. Recommended for : Isco Model 948 or other 12-Volt lead-acid batteries Input Voltage Output Voltage 6 Amp Portable 120V AC/60 Hz* 12V DC @ 6A *Contact factory for 240V AC 50 Hz. Solar-powered Chargers Isco Solar-powered Chargers deliver energy in long-term applications where AC power isn t available. Units are selected from a variety of solar panel options to best suit your specific application. Contact Isco or your authorized Isco representative to determine the right size and style for your needs. Remote and/or long-term Installations at sites without available AC power 6

Charger/Battery Compatibility Recommended Requires Connector # 60-311-4015 Charger and Power Pack * Models Appropriate Battery Model Ni-Cad Lead-Acid 934 945 946 947 948 961 Wall-mount 963 Wall-mount 965 Five-station 6-Amp Clamp-on 913 Power Pack 923 Power Pack * Isco Power Pack Models 913 and 923 include battery charging capability. Requires Lantern Battery Charger Adapter. Isco Part #60-2004-040. Teledyne Isco, Inc. 4700 Superior Street Lincoln, NE 68504 USA Phone: (402) 464-0231 USA & Canada: (800) 228-4373 fax: (402) 465-3022 e-mail: iscoinfo@teledyne.com website: www.isco.com Isco reserves the right to change specifications without notice. 2007 Teledyne Isco, Inc. Printed in U.S.A. L-0104 Rev. 7/07