Description TR D

Similar documents
Product and functional description

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Operating instructions Evaluation system for flow sensors VS / / 2013

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Operating and installation instructions Differential pressure monitor

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

Product and functional description

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED CONVERTERS 48 V

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

Product and functional description

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Non-communicating room controllers

CC COMPACT DIP SWITCH

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

Operating Instructions

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Supplementary operating instructions for your air curtain system Controller TMC 500

Product and Application Description

Operating Instructions VEGAMET 381

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Figure 1: Device components

Electronic time relays ATI, BTI, SDT and MTI

Operating instructions. Speed monitor D / / 2014

Multifunctional time delay relay MFT U31S, MFT U41SE

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Series SD-3PB Digital THERMOSTAT + TIMER

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Binary output and supervision 520CSD01 Data sheet

Page 1. Universal controller for solar energy systems with one collector array and one storage reservoir COMMISSIONING MANUAL

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Electronic timer CT-ERD.12

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

Test devices and Multifunction timer relay

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

KNX DALI Gateway Plus - User Manual

TIME DELAY RELAYS Product Summary

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

7 Day Digital Programmer 1 Channel Surface Mount

Operating Manual RISH DPM Hz

Operating instructions only for authorized, skilled electricians with EIB training

Electronic timer CT-AHD.22

Operating instructions. Standstill monitor A / / 2011

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Product and functional description

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Operating manual Solareg II ENERGY

DALI Professional Controller-4. Control unit Operating instructions

EWCH 485 Electronic Pulse Counter

is then retained absolutely without interruption.

Operating Instructions. For. Level Control Module. Model SSR 1000

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

ProMinder Standard Heating System Installation Instructions

- Pt100 temperature relay for up to 12 sensors with electric 10 MBit/s Ethernet interface Configuration through Web server

7 Day Digital Programmer 2 Channel Surface Mount

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

ETD-BL-1T-OFF-CC- 10S

920 Remote Control (RC) Switches

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Operating instructions. Switching amplifier DN0210 DN / / 2015

OPERATING INSTRUCTIONS

Tempco Instruction Manual

Operating instructions Monitor FD-2 DR2005 DR / / 2007

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

PTC/PT100 board 2.0 Option

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

PSR DC/ESP4/2X1/1X2

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Product and Application Description

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

The LED display (1) turns green when the load is switched on.

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Power Supply Systems KNX PS640 and KNX PS640 USB

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

Transcription:

Description TR D 78385 270607 Electronic double thermostat with heat curve in a DIN standard bar enclosure 1. Short Description The electronic double thermostat serves to control electric heating panels used for piglet nest heaters. Two independent control circuits have been integrated into the device; both record the actual temperature by means of a temperature sensor and enable a relay output in accordance to the settings. The electric heating panels are controlled directly via the output. 2. Operating Elements 1 Connecting terminals for mains supply and load 2 Output signal indicator for the relays; mains voltage on (LED) 3 Temperature indicator 4 Connecting terminals for the sensors 5 Buttons for operating/programming 6 Dial potentiometer for operating/programming

3. Function The device can be used in two different modes of operation per automatic control loop to accommodate the different tasks. Normal operation is for continuous control at a constant nominal temperature; to adjust the nominal temperature to a growth cycle it is possible to switch to heat curve mode. The set values are set directly on the potentiometer of the required automatic control loop according to the mode of operation or are determined by the specified heat curve. A 3-digit display has been integrated into the respective automatic control loop to indicate the actual temperature. The actual temperatures are displayed in intervals of approximately 8 seconds. To allocate the displayed temperature to the respective automatic control loop the LED flashes for the corresponding output. The output signal indicator for each relay is indicated by a red LED in the device (LED on = relay on). The mode of operation currently selected is also indicated via the display. 3.1. Normal Operation Mode In normal operation mode, the device functions as a two position controller with an adjustable set value. The set value is set with the respective potentiometer and is not time restricted. The required value is set on a notional scale ranging from 20 C 50 C. As the set value is being adjusted, it is shown on the display. After approx. 3 seconds, the actual value is displayed once again. The set value is also displayed by briefly pressing the CHx button. The green LED flashes while a set value is being displayed! However, the LED for the respectively selected output is lit up constantly. In this way, it is easy to see that a set value is being indicated and also which one. By turning the potentiometer to the OFF position the control is switched off completely. Instead of the actual temperature being displayed OFF will then appear after a short time. The heating circuit can only be completely turned off when in normal operation mode. The switch over from normal operation to heat curve operation for the respective circuit is achieved by pressing the CHx button for approx. 5 seconds. Switching back to normal operation is achieved in the same manner. 3.2. Heat Curve Operation Mode In heat curve mode the set value is given using a programmed time period. For this, the ts.. (start temperature), te.. (end temperature) and hr.. (length of time in hours per reduction of the set value by 1K) parameters are stored in the device. Following the switch over from normal operation to heat curve operation the timer stops and the te.. parameter specifies the nominal temperature. To signalise that the timer has stopped, the decimal point in the right-hand section lights up constantly. By briefly pressing the CHx button (approx. 1s) the set value ts.. is momentarily displayed and the timer starts. The starting temperature is set by the ts.. parameter; the decimal point in the right-hand section will flash. By pressing the CHx button again, the process is stopped again. The timer is thus reset, the set value which is momentarily displayed is at te.. and the decimal point will light up continuously again.

If the set value of a cycle needs to be adjusted during the current heat curve, this can be carried out using the relevant set value potentiometer. While the potentiometer is being turned, the display shows the actual applicable set value. At the same time, the notional setting is compared to this value. Depending on how much time has passed this can be at different points on the (conceived) scale. If the two values agree, the set value can be changed. After setting the desired value, this will automatically be accepted within a few seconds and therefore become valid. The actual temperature will be displayed again. The timer is not interrupted by this. Following execution of the heat curve, the manual adjustment of the set value will be deleted again and the stored values will apply without restriction. To control the actual set value in a current heat curve this can be shown on the display by briefly pressing the CHx button (< 1s). After a few seconds, the display will switch over to an actual value again. The green LED flashes while a set value is being displayed! However, the LED for the respectively selected output is constantly lit up. In this way, it is easy to see that a set value is being indicated and also which one. After the heat curve starts the ts.. setting serves as the set value. The hr.. parameter now specifies after how many hours the nominal temperature is to be reduced by 1K (settings from 1 to 99). The cycle of the heat curve is determined by the difference in temperature between ts.. and te.. and the hr.. interval. Refer to the calculation example. Example: ts.. = 32 C, te.. = 25 C, hr.. = 24 (h/k) 32 C - 25 C = 7K * 24 hr/k = 168 hr (7 days). The te.. nominal temperature is reached after 168 hours of operations and the heat curve is thus executed. This is controlled without time restrictions using the te.. value (25 C). 3.3. Programming the Heat Curve The parameters for the heat curves are programmed in a submenu. To do this the CH1 and CH2 buttons have to be pressed at the same time for approx. 5 seconds. After making changes in the submenu, the different parameters can be browsed through using the set value potentiometer from the second automatic control loop. By pressing CH2 the parameter value will be displayed. To change this, the potentiometer has to be moved over the notional scale range slowly. If the stored value is the same as the set value, this is captured and can now be changed. By pressing CH2 again the desired setting can be saved and changes made in the list of parameters. In this way, the desired values can be changed one after the other. The submenu is exited in the End setting and by pressing CH2, and will switch back to the previous mode of operation. Changes cannot be made to a current heat curve; this can also not be interrupted by the submenu being entered.

The diagram shows the submenu and the values behind the parameters. The CH2 button is always used to switch between the parameter and the value. The values are set using the potentiometer from the second automatic control loop. It is to be noted that the programmed starting value always has to be greater than the end value. If the values are not programmed properly (ts.. < = te..), the timer cannot be started. Control continues as before according to the te.. value. If a longer break occurs during input (approx. 3 minutes), programming is cancelled. Non-confirmed values are rejected. 3.4. Functions after Commissioning or Restoration of Power The normal operation and heat curve operation are saved. Following restoration of voltage, the last mode will be recalled and applied as follows: Normal operation : Control is carried out according to the set value (potentiometer setting); this also includes the OFF setting! Heat curve operation : The timer is stopped; Control is carried out according to the set value of the te.. parameter 3.5. Visual Indicators There is an LED (red) per output to indicate the switching statuses on the relay. Another LED (green) indicates the device is ready for operation. There is an integrated 3-digit display to show the nominal and actual temperatures, a help window for programming and also status reports. To be able to match the displayed temperature with the corresponding heating circuit, the respective LED flashes briefly. The actual values displayed (sensors) are shown alternately for approx. 8 seconds. 3.6. Sensor Monitoring Both of the sensor inputs are monitored for short circuits or breaks. If the device detects a defective sensor, the corresponding output will be switched off. Instead of the actual value being shown on the display Err will be displayed. The limits for monitoring errors are temperatures > 80 C and < -20 C. 3.7. Output Each of the device s channels has a relay output (N/O contact). This is lead through non-floating (with L) at the respective terminal. See the Technical Data for the maximum load. The device has no internal fuse. Make sure the customer has provided proper fuses. 3.8. Supply Voltage The device is designed for connection to an alternating current of 23OV/5OHz. It has no on/off switch; it is only intended for connection to permanently installed lines.

4. Assembly Only for electricians! ATTENTION: Incorrect installation may result in damages to the control device! No liability is taken for damages incurred by incorrect connection and/or improper handling! The device is exclusively designed for installation in switch boxes! Disconnect lines prior to work on the equipment! Only authorised technicians are allowed to connect and service the equipment! Connections are to be made in accordance with the enclosed main circuit diagram. The device is only intended for connection to permanently installed lines. When installing the device, care is to be taken that cables carrying mains voltage, such as mains supply and relay connection cables, do not come into contact with low voltage cables, such as sensor cables (minimum distance of 4 mm in the case of basic insulated conductors). Furthermore, adequate protective measures need to be taken to ensure that none of the terminal leads become loose; these must fulfil the requirements as according to EN 60730, part 1. For example, this can be done by securing cables with cable ties. To be taken into account is the VDE 0100 (VDE Association of German Electrical Engineers), particularly part 705, EN 60730, part 1, and the regulations of the local electricity board. The sensor cables are not to be laid with other conductor lines; in this way, interference can be prevented. The device is to be fused with a line circuit breaker with a maximum 16A. The connecting lines have to be laid, so that they are out of the reach of animals. The connecting lines are to be laid protected in the floor screed (empty pipe). Live cables (L and N) are not to be looped from device to device; rather, they must each be wired separately from a bus bar. If the device does not work, please check it has been connected properly first and check the power supply.

5. Technical Data Type TR - D Temperature range: 20...50 C Switching differential: +/- 0.2K, fixed Sensor inputs: PTC 2k, poles do not have to be taken into account Line voltage: 23OV AC ±10% Received power: approx. 3VA Output/type of contact: Relay, N/O contact, non-floating with L Max. permissible switching current: per circuit/relay 8(2)A, 230V AC cos-phi = 1, at an environmental temperature of a max. +40 C Electric life span: min. 0.5 x 1O 5 switching cycles Electric connections: Screw connectors Permissible environmental temperature: 0 to +40 C Storage temperature: -10 to +70 C Set value adjustment: with knob, sometimes with push-button Programming: with knob and push-button Visual indicator: LEDs for the switching status of the relay (red) and mains voltage (green), 3-digit display for temperature and programming Casing: Material: Plastic Protection system: IP 2O Protection class: II according to DIN EN 60730-1 (in the case of switch box installation) Dimensions: 70 x 90 x 75 mm (4* machine width) Mounting: on DIN bars Weight: approx. 230g

6. Dimensioned Drawing

7. Circuit Diagram Sensor Sensor Circuit 1 Circuit 2 Maximum 18 thermo E per heating circuit! Subject to changes