Overvoltage Protection Devices

Similar documents
Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

6/2 Product overview. 6/3 Lightning arresters, type 1. 6/5 Combination surge arresters, type 1 and type 2. 6/7 Surge arresters, type 2

BETA Protecting Overvoltage Protection Devices

Lightning and Surge Arresters

Lightning and Surge Arresters

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Surge Protection Devices Ex9UE2

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

PT 3-PB-ST. Extract from the online catalog. Order No.:

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Surge Protection Devices and Surge Protection Kit

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

8WH5 Combination Plug-In Terminals

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Autoprotected Surge Arresters New OVR Plus range

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Miniature Circuit Breakers for Railway Applications

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

wietap wietap Overvoltage Protection Tensions running high

ETITEC - Lightning and Surge Arresters

5SL Miniature Circuit Breakers

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

STEP-PS/1AC/24DC/1.75

VAL-CP-3S-350. Extract from the online catalog. Order No.:

MINI-PS AC/10-15DC/8

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 1AC/24DC/ 5

BLITZDUCTOR XTU Universal lightning current / surge arrester

R3&A Limited, Cobourg, ON

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Contact protection relay

Surge Protection Devices Type 1+2

Surge protection for gutter heating systems

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

SITOP in the SIMATIC Design

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Surge protection for frequency converters

Overvoltage Protection for low-voltage supplies

POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment

ALPHA SIMBOX Small Distribution Boards

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Siemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities.

2 Principle of lightning protection

PHOENIX CONTACT - 01/2007

SPD Catalogue. SPD Catalogue. for AC applications

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

NEW surge protective devices

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

Solid-State Contactors

QUINT-PS AC/24DC/10

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

Application-optimised DEHNshield Combined Arrester

Lightning and surge protection for electromobility

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Overvoltage Protection

PV protective solutions

QUINT-PS/ 1AC/24DC/20/CO

Surge Protective Device

Surge protection for transceiver systems

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

Lightning Current Equipotential Bonding SPDs

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

SPM Series Plug-in Surge Protection

Surge & Filter Protection Addressing your industrial power quality needs.

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Modular surge protective devices (SPDs)

Lightning and surge protection for single-family houses

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

S400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks

Installation / Control Technique

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

160 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

TRIO-DIODE/12-24DC/2X10/1X20

interface Overvoltage Protection

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections

Surge Protection. tra Combinations. Surge Protection

Building Surge Protection Information Pack

Transcription:

Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type 2 /12 5SD7 surge arresters, type 3 /13 Accessories for surge arresters /14 Configuration /17 5SD7 surge arresters for measuring and control technology For further technical product information: Configuration Manual Overvoltage Protection Devices 2014 Article No.: 3ZW1012-5SD74-0AC1 Service & Support Portal: www.siemens.com/lowvoltage/productsupport Product List: Technical specifications Entry List: Certificates / Characteristics / Download / FAQ / Manuals / Updates Siemens LV 10 2014

Overvoltage Protection Devices Siemens AG 2014 Introduction Overview Devices Page Application Standards 5SD7 lightning arresters, type 1 /3 With plug-in protective modules for TN-C, TN-S and TT systems Rated voltage 350 V AC for lightning currents from 25 ka to 100 ka. All versions with remote signaling contact. For installation in main distribution boards, upstream or downstream of the counter. 5SD7 combination surge arresters, type 1 and type 2 /5 With plug-in protective modules for TN-C, TN-S and TT systems Rated voltage 350 V AC for lightning currents from 25 ka to 100 ka. All versions with remote signaling contact. For installation in main distribution boards downstream of the counter. EN 143-11 EN 143-11 5SD7 combination surge arresters, type 1 / type 2 /7 With plug-in protective modules for TN-C, TN-S and TT systems. Rated voltage 335 V AC for lightning currents or discharge surge currents up to 50 ka. Versions with or without remote signaling. EN 143-11 5SD7 surge arresters, type 2 /9 With plug-in protective modules for TN-C, TN-S and TT systems Rated voltage 350 V AC, rated discharge surge current 20 ka and discharge surge current 40 ka. For installation in sub-distribution boards. EN 143-11 5SD7 surge arresters, type 3 /12 With plug-in protective modules for single-phase and three-phase systems. Rated voltage, single-phase 24 V, 120 V, 230 V AC/DC and three-phase 230/400 V AC. For installation as close as possible upstream from the terminal equipment. EN 143-11 Accessories for surge arresters /13 Plug-in parts for lightning and surge arresters and through-type terminals for installation. EN 143-11 Configuration /14 Everything you need to know about overvoltage protection: Function, mounting and technical connections. I201_13815 5SD7 surge arresters for measuring and control technology /17 With plug-in protective modules for measuring and control technology for installation in signal circuits. EN 143-21 /2 Siemens LV 10 2014

Siemens AG 2014 Overvoltage Protection Devices 5SD7 lightning arresters, type 1 Overview Type 1 lightning arresters are the most powerful overvoltage protection. They protect low-voltage systems against any overvoltage or high impulse currents that may be triggered by a direct or indirect lightning strike. All lightning arresters are fitted with a mechanical fault indication, which does not require an extra power supply. The lightning conductors can therefore also be used in the precounter area. The protective modules are available as connectors. The majority of lightning arresters have a remote signaling contact, which signals if the device fails. Technical specifications 5SD7411-2 5SD7412-1 5SD7413-1 5SD7414-1 Standards IEC 143-11 (DIN VDE 0754-) Approvals KEMA, UL/cUL UL/cUL UL/cUL Rated voltage U N V AC 90 240 240/415 Rated arrester voltage U C L/N, N/PE, L/PEN V AC 800 350 350 350 Lightning impulse current I imp (10/350 s) L/N or L/PEN, 1P/3P ka 35 25 25/75 25/75 N/PE ka -- 100 -- 100 Rated discharge surge current I n (8/20 s) L/N or L/PEN, 1P/3P ka 35 25 25/75 25/75 N/PE ka -- 100 -- 100 Protection level U p L/N, N/PE, L/PEN kv 4.5 1.5 1.5 1.5 Follow current discharge capacity I fi (AC) L/N or L/PEN for 24 V/350 V ka -- 50/25 50/25 50/25 N/PE A -- 100 -- 100 Response time t A L/N or L/PEN ns 100 100 100 100 L-(N)-PE ns -- 100 -- 100 Max. back-up fuse acc. to IEC 143-1 For stub wiring A 400 gl/gg 315 gl/gg 315 gl/gg 315 gl/gg For V-wiring A 125 gl/gg 125 gl/gg 125 gl/gg 125 gl/gg Short-circuit withstand current ka rms 50 50 50 50 with max. back-up fuse Temperature range C -40... +80 Degree of protection IP20, with connected conductors Conductor cross-section Finely stranded mm 2 1... 50 2.5... 25 2.5... 25 2.5... 25 Solid mm 2 1... 50 2.5... 35 2.5... 35 2.5... 35 Siemens LV 10 2014 /3

Overvoltage Protection Devices Siemens AG 2014 5SD7 lightning arresters, type 1 Selection and ordering data Lightning arresters Version 1-pole With remote signaling Mounting width MW DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. -- 1) 5SD7411-2 1 1 unit 037 3.300 kg 2-pole For TN-S and TT systems with remote signaling 4 5SD7412-1 1 1 unit 037 0.808 3-pole For TN-C systems With remote signaling 5SD7413-1 1 1 unit 037 1.221 4-pole For TN-S and TT systems With remote signaling 8 5SD7414-1 1 1 unit 037 1.09 1) No modular installation device. /4 Siemens LV 10 2014 * You can order this quantity or a multiple thereof.

Siemens AG 2014 Overvoltage Protection Devices 5SD7 combination surge arresters, type 1 and type 2 Overview Combination surge arresters, type 1 + 2 are compact designs comprising lightning arresters (type 1) and surge arresters (type 2). They protect low-voltage systems against overvoltages triggered by lightning strikes or by switching operations in the network. A thermal isolating arrester for the varistors offers a high degree of protection against overload. The protective modules are available as connectors. All combination surge arresters have a remote signaling contact, which signals if the device fails. Technical specifications 5SD7442-1 5SD7443-1 5SD7444-1 Standards IEC 143-11; EN 143-11 Approvals KEMA, UL/cUL Rated voltage U N V AC 240 240/415 Rated arrester voltage U C L/N, N/PE, L/PEN V AC 350 Lightning impulse current I imp (10/350 s) L/N or L/PEN, 1P/3P ka 25 25/75 25/75 N/PE ka 100 -- 100 Rated discharge surge current I n (8/20 s) L/N or L/PEN, 1P/3P ka 25 25/75 25/75 N/PE ka 100 -- 100 Protection level U p L/N, N/PE, L/PEN kv 1.5 Follow current discharge capacity I fi (AC) L/N or L/PEN ka 25 25 25 N/PE ka 100 -- 100 Response time t A L/N or L/PEN ns 100 100 100 L-(N)-PE ns 100 -- 100 Max. back-up fuse Acc. to IEC 143-1 For stub wiring A 315 gl/gg For V-wiring A 125 gl/gg Short-circuit withstand current with max. back-up fuse ka rms 25 Temperature range C -40... +80 Degree of protection IP20, with connected conductors Conductor cross-section Finely stranded mm 2 2.5... 25 Solid mm 2 2.5... 35 Mounting width Acc. to DIN 43880 MW 4 8 Visual function/fault indication Yes Siemens LV 10 2014 /5

Overvoltage Protection Devices Siemens AG 2014 5SD7 combination surge arresters, type 1 and type 2 Selection and ordering data Version Combination surge arresters 2-pole For TN-S and TT systems With remote signaling Mounting width MW DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. 4 5SD7442-1 1 1 unit 037 0.741 kg 3-pole For TN-C systems With remote signaling 5SD7443-1 1 1 unit 037 1.004 4-pole For TN-S and TT systems With remote signaling 8 5SD7444-1 1 1 unit 037 1.403 / Siemens LV 10 2014 * You can order this quantity or a multiple thereof.

Siemens AG 2014 Overvoltage Protection Devices 5SD7 combination surge arresters, type 1 / type 2 Overview Combination surge arresters type 1 / 2 are compact designs which can be used as both lightning arresters type 1 and surge arresters type 2. They protect low-voltage systems against overvoltages triggered by lightning strikes or by switching operations in the network. A thermal isolating arrester for the varistors offers a high degree of protection against overload. The protective modules are available as connectors. The combination surge arresters can be fitted either with or without a remote signaling contact, which signals if the device fails. Technical specifications 5SD7411-2 5SD7412-2 5SD7412-3 Standards IEC 143-11 Approvals KEMA, UL/cUL KEMA 5SD7413-2 5SD7413-3 5SD7414-2 5SD7414-3 5SD7483-5SD7483-7 Rated voltage U N V AC 90 240 240/415 -- Rated arrester voltage U C L/N, N/PE, L/PEN V 800 AC 335 AC 1000 DC Lightning impulse current I imp (10/350 s) L/N or L/PEN, 1P/3P ka 35 12.5 12.5/37.5 12.5 5 N/PE ka -- 50 -- 50 -- Rated discharge surge current I n (8/20 s) L/N or L/PEN, 1P/3P ka 35 12.5 12.5/37.5 12.5/50 15 N/PE ka -- 50 -- -- Max. discharge surge current I max (8/20 s) L/N ka 100 12.5 50/150 50 40 N/PE ka -- 50 -- 50 -- Protection level U p L/N, N/PE, L/PEN kv 4.5 2 1.2 1.2/1.7 3.5 Response time t A L/N or L/PEN ns 100 25 L-(N)-PE ns -- 100 -- 100 25 Max. back-up fuse acc. to IEC 143-1 For stub wiring A 400 gl/gg 10 gl/gg 100 gl/gg 10 gl/gg -- For V-wiring A 125 gl/gg 80 gl/gg -- Short-circuit withstand current ka rms 50 25 with max. back-up fuse Temperature range C -40... +80 Degree of protection IP20, with connected conductors Conductor cross-section Finely stranded mm 2 1... 50 1.5... 25 Solid mm 2 1... 50 1.5... 35 Siemens LV 10 2014 /7

Overvoltage Protection Devices Siemens AG 2014 5SD7 combination surge arresters, type 1 / type 2 Selection and ordering data Version Combination surge arresters 1-pole With remote signaling Mounting width MW DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. -- 1) 5SD7411-2 1 1 unit 037 3.300 kg 2-pole For TN-S and TT systems Without remote signaling 2 5SD7412-2 1 1 unit 037 0.348 With remote signaling 2 5SD7412-3 1 1 unit 037 0.330 3-pole For TN-C systems Without remote signaling 3 5SD7413-2 1 1 unit 037 0.551 With remote signaling 3 5SD7413-3 1 1 unit 037 0.557 4-pole For TN-S and TT systems Without remote signaling 4 5SD7414-2 1 1 unit 037 0.71 With remote signaling 4 5SD7414-3 1 1 unit 037 0.77 3-pole, plug-in For protecting the DC part of the photovoltaic systems up to 1000 V DC acc. to IEC 50539-11 Without remote signaling 3 5SD7483-1 1 unit 037 0.410 With remote signaling 3 5SD7483-7 1 1 unit 037 0.41 1) No modular installation device. /8 Siemens LV 10 2014 * You can order this quantity or a multiple thereof.

Siemens AG 2014 Overvoltage Protection Devices 5SD7 surge arresters, type 2 Overview Surge arresters type 2 are used downstream of lightning arresters type 1 in main distribution boards or sub-distribution boards. They protect low-voltage systems against transient overvoltages, such as those triggered by switching operations. A thermal isolating arrester for the varistors offers a high degree of protection against overload. The protective modules are available as connectors. The surge arresters have an optional remote signaling contact, which signals if the device fails. Technical specifications Standard design N/PE 5SD7481-0 5SD741-0 5SD741-1 5SD7481-1 5SD743-0 5SD743-1 5SD744-0 5SD744-1 5SD7473-1 5SD7483-5 Standards IEC 143-11; EN 143-11 Approvals KEMA -- KEMA -- KEMA, UL/cUL Rated voltage U N V AC 240 240 90 240/415 240/415 500 554/90 Rated arrester voltage U C L/N V AC -- 350 800 -- -- -- 750 L/N or L/PEN V AC -- -- -- 350 350 580 -- N/PE V AC 20 -- -- -- 20 -- -- Rated discharge surge current I n (8/20 s) L/N ka -- 20 15 -- -- -- 45 L/N or L/PEN, 1P ka -- -- -- 20 20 15 -- N/PE ka 20 -- -- -- 20 -- -- Max. discharge surge current I max (8/20 s) L/N ka -- 40 30 -- -- -- 90 L/N or L/PEN, 1P ka -- -- -- 40 40 -- -- L/N or L/PEN, 1P/multi-pole ka -- -- -- -- -- 30 -- N/PE ka 40 -- -- -- 40 -- -- Lightning impulse current I imp (10/350 s) ka 12 -- Protection level U p L/N or L/PEN kv -- 1.4 5 1.4 1.4 2.5 2.7 N/PE kv 1.5 -- -- -- 1.5 -- -- Response time t A L/N or L/PEN ns -- 25 100 25 25 25 25 N/PE ns 100 -- -- -- 100 -- -- Max. back-up fuse acc. to IEC 143-1 For stub wiring A 125 gl/gg 125 gl/gg 100 gl/gg 125 gl/gg 100 gl/gg For V-wiring A 3 gl/gg 3 gl/gg -- 3 gl/gg 80 gl/gg Short-circuit withstand current ka rms 25 with max. back-up fuse Temperature range C -40... +80 Degree of protection IP20, with connected conductors Conductor cross-section Finely stranded mm 2 1.5... 25 Solid mm 2 1.5... 35 Mounting width according to DIN 43880 MW 1 1 2 3 4 3 3 Visual function/fault indication Yes Siemens LV 10 2014 /9

Overvoltage Protection Devices Siemens AG 2014 5SD7 surge arresters, type 2 Narrow design 5SD7422-0 5SD7422-1 5SD7423-0 5SD7423-1 5SD7424-0 5SD7424-1 Standards IEC 143-11 (DIN VDE 0754-) Approvals KEMA/UL/ cul Rated voltage U N V AC 240 240/415 240/415 Rated arrester voltage U C L/N or L/PEN V AC 350 350 350 N/PE V AC 24 -- 24 Rated discharge surge current I n (8/20 s) L/N or L/PEN, 1P/3P ka 20 20 20 N/PE ka 20 -- 20 Max. discharge surge current I max (8/20 s) L/N or L/PEN, 1P/3P ka 40 40 40 N/PE ka 40 -- 40 Protection level U p L/N or L/PEN kv 1.4 1.4 1.4 N/PE kv 1.5 -- 1.5 Response time t A L/N ns 25 25 25 N/PE ns 100 -- 100 Max. back-up fuse Acc. to IEC 143-1 For stub wiring A 125 gl/gg For V-wiring A 3 gl/gg Short-circuit withstand current with max. back-up fuse ka rms 25 25 25 Temperature range C -40... +80 Degree of protection IP20, with connected conductors Conductor cross-section Finely stranded mm 2 1.5... 1 Solid mm 2 1.5... 25 Mounting width Acc. to DIN 43880 mm 2 38 50 Visual function/fault indication Yes Selection and ordering data Version Mounting width DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. mm (MW) kg Surge arresters, standard design 1-pole, N/PE Without remote signaling 1 5SD7481-0 1 1 unit 037 0.122 1-pole Without remote signaling 1 5SD741-0 1 1 unit 037 0.133 With remote signaling 1 5SD741-1 1 1 unit 037 0.139 With remote signaling 2 5SD7481-1 1 1 unit 037 0.418 /10 Siemens LV 10 2014 * You can order this quantity or a multiple thereof.

Siemens AG 2014 Overvoltage Protection Devices 5SD7 surge arresters, type 2 Version Mounting width mm (MW) DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit 3-pole, 3+0 circuit For TN-C systems Without remote signaling 3 5SD743-0 1 1 unit 037 0.32 With remote signaling 3 5SD743-1 1 1 unit 037 0.371 For IT systems With remote signaling 3 5SD7473-1 1 1 unit 037 0.371 PG Weight approx. kg With remote signaling 3 5SD7483-5 1 1 unit 037 0.25 4-pole, 3+1 circuit For TN-S and TT systems Without remote signaling 4 5SD744-0 1 1 unit 037 0.415 With remote signaling 4 5SD744-1 1 1 unit 037 0.432 Surge arresters, narrow design 2-pole For TN-S and TT systems - Without remote signaling 24 (1 1/3) 5SD7422-0 1 1 unit 037 0.220 - With remote signaling 24 (1 1/3) 5SD7422-1 1 1 unit 037 0.229 3-pole For TN-C systems - Without remote signaling 3 (2) 5SD7423-0 1 1 unit 037 0.320 - With remote signaling 3 (2) 5SD7423-1 1 1 unit 037 0.317 4-pole For TN-S and TT systems - Without remote signaling 48 (2 2/3) 5SD7424-0 1 1 unit 037 0.407 - With remote signaling 48 (2 2/3) 5SD7424-1 1 1 unit 037 0.423 * You can order this quantity or a multiple thereof. Siemens LV 10 2014 /11

Overvoltage Protection Devices Siemens AG 2014 5SD7 surge arresters, type 3 Overview Type 3 surge arresters are installed downstream of type 2 surge arresters in sub-distribution boards as close as possible to the load. The protective modules are available as connectors. In the event of a power failure, a remote signaling is output over an optocoupler with open collector output. 2-pole 4-pole 5SD7432-1 5SD7432-2 5SD7432-4 5SD7434-1 Standards IEC 143-11; EN 143-11 Approvals KEMA/UL/ cul KEMA Rated voltage U N V AC 230 120 24 230/400 Rated load current I L (at 30 C) A 2 2 2 3 2 Rated arrester voltage U C V AC 253 150 34 335 Rated discharge surge current I n (8/20 s) ka 3 2.5 1 1.5 Max. discharge surge current I max (8/20 s) ka 10 10 2 4.5 Combined surge U oc kv 2 4 Protection level U p L N/1 V 1500/ 00 850/ 350 550/ 100 1200 Response time t A ns 100 100 100 100 Required back-up fuse, max. A 25 gl/gg 25 gl/gg 25 gl/gg 25 gl/gg Temperature range C -40... +85 Degree of protection IP20, with connected conductors Conductor cross-section Finely stranded mm 2 0.2... 4 Solid mm 2 0.2... 2.5 Mounting width Acc. to DIN 43880 MW 1 1 1 2 Visual function/fault indication Yes Selection and ordering data Version Rated voltage U N Mounting width DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. V AC MW kg Surge arresters, plug-in 2-pole With remote signaling 24 1 5SD7432-4 1 1 unit 037 0.08 120 1 5SD7432-2 1 1 unit 037 0.089 230 1 5SD7432-1 1 1 unit 037 0.087 4-pole With remote signaling 230/400 2 5SD7434-1 1 1 unit 037 0.135 /12 Siemens LV 10 2014 * You can order this quantity or a multiple thereof.

Siemens AG 2014 Overvoltage Protection Devices Selection and ordering data Using the plug-in parts in the various overvoltage protection devices Accessories for surge arresters Plug-in parts 5SD7428-1 5SD7428-0 5SD748-1 5SD7488-0 5SD7488-1 5SD7488-2 5SD7488-4 5SD7498-1 5SD7498-3 Surge arresters, 5SD7485-0 5SD7481-1 5SD7481-1 5SD7483- type 2 5SD7485-1 5SD7483-5 5SD7483-7 5SD7424-1 5SD7424-0 5SD7423-1 5SD7423-0 5SD7422-1 5SD7422-0 5SD7424-1 5SD7424-0 5SD7422-1 5SD7422-0 5SD741-0 5SD741-1 5SD743-0 5SD743-1 5SD744-0 5SD744-1 5SD7481-0 5SD744-0 5SD744-1 5SD7473-0 5SD7473-1 5SD7483-0 5SD7483-1 Plug-in parts 5SD7428-1 5SD7448-1 5SD7418-0 5SD7418-1 5SD7418-2 5SD7418-3 Lightning arresters, type 1 and surge arresters type 1+2 5SD7444-1 5SD7443-1 5SD7442-1 5SD7441-1 5SD7444-1 5SD7443-1 5SD7442-1 5SD7441-1 5SD7414-1 5SD7412-1 5SD7444-1 5SD7442-1 5SD7414-1 5SD7413-1 5SD7412-1 5SD7411-1 5SD7412-2 5SD7412-3 5SD7414-2 5SD7412-2 5SD7412-2 5SD7412-3 5SD7413-2 5SD7413-3 5SD7414-2 5SD7414-3 Plug-in parts for lightning arresters, type 1 For arresters DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. 5SD7418-0 1 1 unit 037 0.254 5SD7418-1 1 1 unit 037 0.270 kg Plug-in parts for surge arresters, type 1 / type 2 5SD7418-0 1 1 unit 037 0.254 5SD7428-1 1 1 unit 037 0.09 5SD7448-1 1 1 unit 037 0.148 Plug-in parts for surge arresters, type 1 and type 2 5SD7418-2 1 1 unit 037 0.101 5SD7418-3 1 1 unit 037 0.132 5SD7498-3 1 1 unit 037 0.103 Plug-in parts for surge arresters, type 2 5SD7428-0 1 1 unit 037 0.07 5SD7428-1 1 1 unit 037 0.09 5SD748-1 1 1 unit 037 0.0 5SD7488-0 1 1 unit 037 0.05 5SD7488-1 1 1 unit 037 0.053 5SD7498-1 1 1 unit 037 0.05 Plug-in part for surge arresters, type 3 5SD7432-1 5SD7437-1 1 1 unit 037 0.042 5SD7432-2 5SD7437-2 1 1 unit 037 0.041 5SD7432-3 5SD7437-3 1 1 unit 037 0.041 5SD7432-4 5SD7437-4 1 1 unit 037 0.042 5SD7434-1 5SD7438-1 1 1 unit 037 0.00 * You can order this quantity or a multiple thereof. Siemens LV 10 2014 /13

Overvoltage Protection Devices Siemens AG 2014 Configuration More information Selection of overvoltage protection devices Situation Systems Basic protection Which type of building do you want to protect? Generally speaking, all our devices are suitable for residential, office, industrial and commercial buildings. Low risk buildings For installation upstream of counters in main distribution boards or in combined main/sub-distribution boards TN-S and TT systems Surge arresters, type 2 5SD7424-0, 5SD7424-1, 5SD744-0, 5SD744-1 Combination surge arresters, type 1 / type 2 5SD7414-2, 5SD7414-3 - No outer lightning protect. - Power supply over ground conductor TN-C systems Surge arresters, type 2 5SD7423-0, 5SD7423-1, 5SD743-0, 5SD743-1 Combination surge arresters, type 1 / type 2 5SD7413-2, 5SD7413-3 High-risk buildings TN-S and TT systems Lightning arresters, type 1 5SD7414-2, 5SD7414-3, 5SD7414-1 - Outer lightning protection system TN-C systems Lightning arresters, type 1 5SD7413-2, 5SD7413-3, 5SD7413-1 - Power supply over overhead lines TN-S and TT systems Surge arresters, type 1 and type 2 5SD7444-1 - Grounded aerial structures TN-C systems Surge arresters, type 1 and type 2 5SD7443-1, 5SD7441-1 IT systems without N conductor incorporated in the cable Typically, IT systems are only installed in special building sections. TN-C, TN-S and TT systems are generally still used in the area of the main distribution board. In this case, the protective devices shown above must be installed. /14 Siemens LV 10 2014

Siemens AG 2014 Overvoltage Protection Devices Configuration Medium protection For installation upstream of counters in main distribution boards or in combined main/sub-distribution boards Fine protection For installation directly upstream of the terminal equipment Surge arresters, type 2 5SD7424-0, 5SD7424-1, 5SD744-0, 5SD744-1 Only required if the distance between the main and sub-distribution boards is > 10 m Surge arresters, type 2 5SD7423-0, 5SD7423-1, 5SD743-0, 5SD743-1 Surge arresters, type 3 For installation in sub-distribution boards or control cabinets 5SD7432-x and 5SD7434-1 With remote signaling Only required if the distance between the main and sub-distribution boards is > 10 m Surge arresters, type 2 5SD7424-0, 5SD7424-1, 5SD744-0, 5SD744-1 Surge arresters, type 2 5SD7423-0, 5SD7423-1, 5SD743-0, 5SD743-1 Surge arresters, type 2 5SD7424-0, 5SD7424-1, 5SD744-0, 5SD744-1 Only required if the distance between the main and sub-distribution boards is > 10 m Surge arresters, type 2 5SD7423-0, 5SD7423-1, 5SD743-0, 5SD743-1 Only required if the distance between the main and sub-distribution boards is > 10 m Surge arresters, type 2 5SD7473-1 3-pole (3+0 circuit) U c = 580 V AC Siemens LV 10 2014 /15

Overvoltage Protection Devices Siemens AG 2014 Configuration Dimensioning of conductor cross-sections The different conductor cross-sections (Lq 1 to Lq 3) must be dimensioned according to the rated current of the miniature circuit breaker or of the fuse. V-wiring MCB L1 Lq1 PAS S P D Lq2 Lq3 PE a) Protection of the SPD using miniature circuit breakers I201_10791a Stub wiring L1 MCB Lq1 F2 PAS S P D Lq2 Lq3 I201_10790a a) Protection of the SPD using miniature circuit breakers F1 L1 Lq1 Lq2 L1 Lq1 F1 Lq2 S P D F2 PAS Lq3 PE I201_10794a Lq3 PAS I201_10793a b) Protection of the SPD using fuses PAS = equipotential bonding strip Conductor cross-sections for lightning arresters (type 1) and combination surge arresters (type 1 and type 2) for V-wiring MCB/fuse (F1) Lq 2 Lq 3 upstream [A gl/gg] [mm 2 ] [mm 2 ] 25 10 1 35 10 1 40 10 1 50 10 1 3 10 1 80 1 1 100 25 1 125 35 1 Conductor cross-sections for surge arresters (type 2) for V-wiring MCB/fuse (F1) Lq 2 Lq 3 upstream [A gl/gg] [mm 2 ] [mm 2 ] 25 35 40 50 10 10 3 10 10 b) Protection of the SPD using fuses Conductor cross-sections for lightning arresters (type 1) and combination surge arresters (type 1 and type 2) for stub wiring MCB/fuse (F1) upstream Lq 2 Lq 3 F2 fuse [A gl/gg] [mm 2 ] [mm 2 ] [A gl/gg] 25 1 / 35 10 1 / 40 10 1 / 50 10 1 / 3 10 1 / 80 10 1 / 100 1 1 / 125 1 1 / 10 25 25 / 200 35 35 10 1) 250 35 35 10 1) 315 50 50 10 1) > 315 50 50 10 1) 1) Recommended fuse. Conductor cross-sections for surge arresters (type 2) for stub wiring MCB/fuse (F1) Lq 2 Lq 3 F2 fuse upstream [A gl/gg] [mm 2 ] [mm 2 ] [A gl/gg] 25 / 32 / 40 / 50 / 3 10 10 / 80 10 10 / 100 1 1 / 125 1 1 / > 125 1 1 125 In the case of surge arresters type 3, the following conductor cross-sections are generally used: Rigid: up to 4 mm 2 Flexible: up to 2.5 mm 2 /1 Siemens LV 10 2014

Siemens AG 2014 Overvoltage Protection Devices 5SD7 surge arresters for measuring and control technology Overview The surge arresters for measuring and control technology are overvoltage protection modules that comprise two parts, a basic element and a plug-in part. Their application area is the protection of signal circuits. The cable shields of basic elements can be either directly or indirectly grounded. The mounting width of the surge arresters is 1 MW. Through the number of integrated paths, it is possible to protect up to four signal cores or two double cores against overvoltages. The arresters are made up of two parts (plug-in part and base element). A mechanical encoding ensures protection against reverse polarity. Technical specifications 5SD7502-0KB 5SD7522-7KA 5SD7522-7KB 5SD7530-4KA 5SD7530-4KB 5SD7540-KB 5SD7541-7KB 5SD7550-4KA 5SD7550-4KB IEC category/en type C1/C2/C3/D1 C1/C2/C3/D1 C1/C2/C3/D1 C1/C2/C3/D1 C1/C2/C3/D1 C1/C2/C3/D1 Max. continuous voltage U C Direct voltage V DC 8 40 14 27 40 14 AC voltage V AC 48 28 8.3 18. 28 9.8 Rated current I N ma 2000 450 450 2000 300 450 Lightning test current I imp Per path ka 5 2.5 2.5 2.5 2.5 2.5 10/350 s Rated discharge current I n 8/20 s Core - Core ka -- 10 10 0.35 -- 10 Core - Ground ka 20 10 10 0.35 10 10 Total surge current I N 8/20 s ka 40 20 20 20 20 20 Output voltage limit at 1 kv/ s Core - Core V -- 55 25 25 -- 25 Core - Ground V 00 450 40 40 55 25 Residual voltage at I n Core - Core V -- 55 -- -- -- 25 Core - Ground V -- -- -- -- 55 40 Response time t A Core - Core ns -- 1 500 1 -- 500 Core - Ground ns 100 100 500 100 1 500 Insertion loss a E Symmetrical in the 50 system db -- Typ. 0.5 -- 0.1 db -- -- (1.5 MHz) to 1 MHz Asymmetrical in the 50 system db 0.1 (1 MHz) -- -- -- 0.5 (1.5 MHz) -- Symmetrical in the 100 system db -- -- 0.2 (5 MHz) -- -- 0.2 (5 MHz) Limit frequency f G (3 db) Symmetrical in the 50 system MHz -- Typ. 8 -- MHz (typ.) -- -- Asymmetrical in the 50 system MHz -- -- -- -- Typ. 8 -- Symmetrical in the 100 system MHz -- -- Typ. 70 -- -- Typ. 70 Resistance per path -- 2.2 -- -- 4.7 2.2 Temperature range C -40... +85 Degree of protection according to IP20 IEC 0529/EN 0529 Flammability class acc. to UL 94 V0 Test standards EN 143-21 EN 143-21 IEC 143-21/ EN 143-21 IEC 143-21/ EN 143-21 EN 143-21 IEC 143-21 Siemens LV 10 2014 /17

Overvoltage Protection Devices Siemens AG 2014 5SD7 surge arresters for measuring and control technology 5SD7581-2 5SD7581-3 5SD7581-5 5SD7581- IEC category/en type B2/C1/C2/C3/D1 B2/C1/C2/C3/D1 B2/C1/C2/C3/D1 B2/C1/C2/C3/D1 Max. continuous voltage U C Direct voltage V DC 185 3.3 12 15 AC voltage V AC 128 2.3 8.3 10.4 Rated current I N ma 380 1500 380 1000 Rated discharge current I n 8/20 s Core - Core ka 5 0.10 5 0.25 Core - Ground ka 5 2 5 0.25 Total surge current I N 8/20 s ka 10 10 10 5 Output voltage limit at 1 kv/ s Core - Core V 250 9 25 25 Core - Ground V 250 700 700 50 Residual voltage at I n Core - Core V 120 15 25 55 Core - Ground V 120 700 55 700 Response time t A Core - Core ns 100 1 100 1 Core - Ground ns 100 100 100 100 Insertion loss a E Symmetrical in the 50 system db -- -- -- -- Asymmetrical in the 50 system db -- -- -- -- Symmetrical in the 100 system db -- 1 0.3 -- Temperature range C -40... +85 Degree of protection according to IEC 0529/EN 0529 IP20 Test standards EN 143-21 EN 143-21 EN 143-21 EN 143-21 /18 Siemens LV 10 2014

Siemens AG 2014 Overvoltage Protection Devices 5SD7 surge arresters for measuring and control technology Selection and ordering data Version DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. kg Surge arresters Coarse protection for 2 single-sided grounded signal 5SD7502-0KB 1 1 unit 037 0.090 leads Protection for 2-wire signal circuits grounded via gas 5SD7522-7KA 1 1 unit 037 0.101 arresters Protection for 2-wire signal circuits grounded directly 5SD7522-7KB 1 1 unit 037 0.100 Protection for 2 signal cores with shared reference 5SD7530-4KA 1 1 unit 037 0.091 potential, grounded via gas arresters Protection for 2 signal cores with shared reference 5SD7530-4KB 1 1 unit 037 0.090 potential, grounded directly Protection for one 4-wire signal circuit, operated 5SD7540-KB 1 1 unit 037 0.100 without potential to ground, grounded directly Protection for 4 signal cores with shared reference 5SD7541-7KB 1 1 unit 037 0.100 potential, grounded directly Protection for field bus systems and signal circuits 5SD7550-4KA 1 1 unit 037 0.102 in 3-wire or 4-wire method, grounded via gas arresters Protection for field bus systems and signal circuits 5SD7550-4KB 1 1 unit 037 0.101 in 3-wire or 4-wire method, grounded directly Overvoltage protection for analog and digital telecommunication interfaces, connection: RJ45 5SD7581-2 1 1 unit 037 0.32 Overvoltage protection for Ethernet interfaces up to 10 Gbits 5SD7581-3 1 1 unit 037 0.315 D-SUB-9 intermediate connectors with overvoltage protection for RS 485 interfaces 5SD7581-5 1 1 unit 037 0.321 D-SUB-9 intermediate connectors with overvoltage protection for V.24 interface 5SD7581-1 1 unit 037 0.322 * You can order this quantity or a multiple thereof. Siemens LV 10 2014 /19

Overvoltage Protection Devices Siemens AG 2014 5SD7 surge arresters for measuring and control technology Plug-in parts 5SD7502-0 5SD7522-7 5SD7530-4 5SD7540-5SD7550-4 5SD7541-7 Surge arresters 5SD7502-0KB 5SD7522-7KA 5SD7530-4KA 5SD7540-KB 5SD7550-4KA 5SD75SD7541-7KB 5SD7522-7KB 5SD7530-4KB 5SD7550-4KB Accessories for surge arresters Version DT Article No. Price PU (UNIT, SET, M) PS*/ P. unit PG Weight approx. 5SD7522-7 1 1 unit 037 0.024 5SD7530-4 1 1 unit 037 0.042 5SD7540-1 1 unit 037 0.047 5SD7550-4 1 1 unit 037 0.02 5SD7541-7 1 1 unit 037 0.02 5SD7502-0 1 1 unit 037 0.020 kg /20 Siemens LV 10 2014 * You can order this quantity or a multiple thereof.