Safety instructions Overvoltage protection B81-35

Similar documents
Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions VEGATOR 121, 122

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Operating Instructions

SMARTLINE RM76 Supplementary instructions

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

MANUAL Surge Protectors

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

5 Fieldbus Technology

Installation & Operation Manual

Refer to attachment for more details. Andreas Meyer

Signal conditioning instruments VEGASCAN 693. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

PI-EX-ME-2NAM/COC-24VDC

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

PHOENIX CONTACT - 12/2007

DR7100 SERIES Supplementary instructions

PI-EX-ME-2NAM/COC-120VAC

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Resistance thermometer With spring-loaded tip Model TR55

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Installation & Operation Manual

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Operating Instructions

NAMUR INDUCTIVE SENSOR ATEX/IECEx

Technical Data. General specifications. Rated operating distance s n 3 mm

Safety Instructions Cerabar S PMP71, PMP75

Micro Motion, Inc. Page 1 of 6

Reed sensor For bypass level indicators Model BLR

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Terminal Boxes Series 8118

Interface and Supply module. IPC 3x0i / PSC 3x0i

Grounding Monitoring Device Series 8485

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Explosive atmospheres occur when flammable gases, mist, vapors or dust are mixed with air. This creates a risk of explosion.

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Product information Ultrasonic

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

ExCos-P Pressure sensor 20 Pa Pa

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Pneumatic Control/Feedback

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Pneumatic Control/Feedback

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

General Specifications

Bayonet resistance thermometer Model TR53

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

CPU module for zone 2 Series 9442/35

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

MINI MCR-SL-MUX-V8-FLK 16

Threaded resistance thermometer Miniature design Model TR10-D

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

MACX MCR-EX-SD LP(-SP)

Operating manual ELX channel digital input terminal for NAMUR sensors, Ex i. Version: Date:

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

Dräger Polytron 8200 Stationary gas detector (CatEx)

Grounding Monitoring Device Series 8485

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Safety Instructions Omnigrad TRxx, TCxx, TxCxxx

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

PHOENIX CONTACT - 02/2008

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

Safety Instructions Micropilot FMR56/57

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Technical Data. Dimensions

Slot Resistance Thermometers

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

IEEE Mb/s single twisted pair Ethernet for Process Industry

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Safety Instructions Micropilot FMR50/51/52/53/54/56/57

PHOENIX CONTACT - 05/2007

Threaded resistance thermometer With protection tube Model TR10-C

Transcription:

Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001

Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application conditions... 5 5 Protection rating... 6 6 Protection against static energy... 6 7 Installation/construction... 6 8 Grounding... 6 9 Isolation voltage against earth, test of the dielectric strength... 7 Please note: These safety instructions are part of the operating instructions: 50708 - Overvoltage arrester 51002 - Certificate of Conformity IECEx BVS 15.0084X Editing status: 2016-06-08 2 Overvoltage protection B81-35

1 Area of applicability These safety instructions apply to the overvoltage arresters B81-35 according to the IEC Certiificate of Conformity IECEx BVS 15.0084X (certification number on the type label). 2 General information The instrument of the overvoltage arrester B81-35 is suitable as overvoltage protection of intrinsically safe circuits with the protective level Ex ia [ia Ga] of instrument category EPL-Ga the protective level Ex ia [ia Da] of instrument category EPL-Da the protective level Ex ia of instrument category EPL-Ga or EPL-Da the protective level Ex ib of instrument category EPL-Gb or EPL-Db the protective level Ex ic of instrument category EPL-Gc or EPL-Dc The overvoltage arresters B81-35 based on a gas discharge tube are suitable for installation in certified intrinsically safe VEGA instruments, the sensor circuit of which leads to areas requiring EPL-Ga or EPL-Da instruments. The overvoltage arresters B81-35 for protection of intrinsically safe circuits with protective level Ex "i" of EPL-Ga/Gb, EPL-Gb or EPL-Gc, EPL-Da/Db, EPL-Db or EPL-Dc instruments take over the task of limiting transient overvoltages, as necessary overvoltage protection systems acc. to IEC 60079-25 or IEC 60079-14. When mounted, the overvoltage arresters B81-35 are suitable as intrinsically, electrical instrument for use in hazardous areas of all combustible substances of explosion group IIA, IIB and IIC, for applications requiring EPL-Ga, EPL-Gb or EPL-Gc instruments. The atmospheres can be also combustible gases, fog or vapours. When mounted, the overvoltage arresters B81-35 are suitable as intrinsically, electrical instrument for use in hazardous areas of all combustible dusts of explosion group IIA, IIB and IIC, for applications requiring category EPL-Da, EPL-Db or EPL-Dc instruments. The overvoltage arresters B81-35 are suitable for protection of certified intrinsically safe VEGA instruments in two-wire version with the following signal transmission: Analogue version 4 20 ma current output 4 20 ma current output with superimposed HART protocol Digital version Profibus PA Foundation Fieldbus Modbus and Levelmaster protocol If the overvoltage arresters B81-35 are used for protection of intrinsically safe signal circuits, then the general installation regulations for explosion protection, IEC 60079-14, as well as these safety instructions and the operating instructions manual must be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. Installation in EPL-Ga/Gb instruments The overvoltage arresters B81-35 are suitable for installation in instrument for installation in hazardous areas (Zone 1), requiring an EPL-Ga/Gb instrument. The electronics housing is in the area (Zone 1) requiring EPL-Gb instruments. The sensor circuit leads into an area (Zone 0) requiring EPL-Ga instruments. Installation in EPL-Ga instruments As EPL-Ga instrument, the overvoltage arresters B81-35 are only used as additional protec- Overvoltage protection B81-35 3

tion of the electronics. The installation in EPL-Ga instruments does not meet all requirements of IEC 60079-14 chapter 16.3 (edition 2013). A suitable overvoltage arrester must be connected as close as possible at the entry in the installation location with EPL-Ga. The safety instructions of the respectively connected overvoltage arrester are valid. Installation in EPL-Gb instruments The overvoltage arresters B81-35 are suitable for installation in hazardous areas requiring an EPL- Gb instrument. Installation in EPL-Gc instruments The overvoltage arresters B81-35 are for installation as protection of the electronics of instruments in hazardous areas, requiring an EPL-Gc instrument. Installation in EPL-Da/Db instruments The overvoltage arresters B81-35 are suitable for installation in instrument for installation in hazardous areas (Zone 21), requiring an EPL-Da/Db instrument. The electronics housing is in the area (Zone 21) requiring EPL-Db instruments. The sensor circuit leads into an area (Zone 20) requiring EPL-Da instruments. Installation in EPL-Da instruments As EPL-Da instrument, the overvoltage arresters B81-35 are only used as additional protection of the electronics. The installation in EPL-Da instruments does not meet all requirements of IEC 60079-14 chapter 16.3 (edition 2013). A suitable overvoltage arrester must be connected as close as possible at the entry in the installation location with EPL-Da. The safety instructions of the respectively connected overvoltage arrester are valid. Installation in EPL-Db instruments The overvoltage arresters B81-35 are suitable for installation in hazardous areas requiring an EPL- Db instrument. Installation in EPL-Dc instruments The overvoltage arresters B81-35 are for installation as protection of the electronics of instruments in hazardous areas, requiring an EPL-Dc instrument. Labelling IEC 60079-0, IEC 60079-11, IEC 60079-25 Ex ia [ia Ga] IIC T6 T1 Gb Ex ia IIC T6 T1 Ga Ex ib IIC T6 T1 Gb Ex ic IIC T6 T1 Gc Ex ia [ia Da] IIIC T135 C Db Ex ia IIIC T135 C Da Ex ib IIIC T135 C Db Ex ic IIIC T135 C Dc 4 Overvoltage protection B81-35

3 Technical data Overvoltage arrester B81-35 Power supply and signal circuit: (terminals 1[+], 2[-]) Power supply and signal circuit: (plug connection) Ignition protection type intrinsic safety Ex i IIC, IIIC U 40 V DC i I 131 ma i or for use in intrinsically safe FISCO fieldbus instruments U 17.5 V DC i I 500 ma i P 5.5 W i C = negligibly small i L = negligibly small i DC response voltage 600 V, -20 %/+35 % Impulse response voltage 850 V at 100 V/µs, 1100 V at 1000 V/µs For connection to an intrinsically safe circuit U = U of the certified, intrinsically safe voltage supply I = I of the certified, intrinsically safe voltage supply P = P of the certified, intrinsically safe voltage supply C = C of the certified, intrinsically safe voltage supply L = L of the certified, intrinsically safe voltage supply 4 Application conditions Permissible ambient temperatures depending on temperature class EPL-Ga instrument Temperature class T6-40 +63 C T5-40 +75 C T4, T3, T2, T1-40 +85 C Overvoltage protection B81-35 Permissible ambient temperature on the electronics The pressure of explosive mixtures must be between 0.8 1.1 bar in applications requiring EPL-Ga instruments. The permissible operating temperatures without hazardous atmosphere are specified in the respecitive manufacturer information, for example the operating instructions. EPL-Gb instrument Temperature class T6-40 +80 C T5, T4, T3, T2, T1-40 +85 C Permissible ambient temperature on the electronics The permissible operating temperatures without explosion-endangered atmosphere are mentioned in the respective manufacturer instructions, e.g. operating instructions manuals. 5

EPL-Gc instrument Temperature class T6-40 +80 C T5, T4, T3, T2, T1-40 +85 C Permissible ambient temperature on the electronics The permissible operating temperatures without explosion-endangered atmosphere are mentioned in the respective manufacturer instructions, e.g. operating instructions manuals. In mounted condition, the respective temperature classes and permissible ambient temperatures of the VEGA instrument and the overvoltage arrester B81-35 must be taken into account and maintained. EPL-Da, EPL-Db, EPL-Dc instrument Permissible ambient temperature: -40 +85 C Max. surface temperature increase: negligible 5 Protection rating For applications in hazardous areas, overvoltage arrester B81-35 must be mounted in a suitable housing with min. protective level IP 20 acc. to IEC 60079-11. For applications in dust-explosive areas, overvoltage arrester B81-35 must be mounted in a suitable housing with min. protective level IP 5X acc. to IEC 60079-11. When mounted, the protection is determined by the respective VEGA instrument. The specifications in the operating and safety instructions of the respective VEGA instrument are applicable. 6 Protection against static energy In mounted condition and without outer parts of the overvoltage arrester, the instructions of the respective VEGA instruments of the manufacturer specifications, e.g. the operating instructions must be taken into account. 7 Installation/construction The overvoltage arresters B81-35, as far as required, must be only used in the VEGA housing with respective meachnical connection on the terminals of the signal and supply circuit. 8 Grounding To ensure the function of the overvoltage arrester, it is absolutely necessary to connect the overvoltage arrester B81-35 with the local potential equalization. For this purpose, the green-yellow protective ground cable must be connected via the cable lug to the ground cable inside the VEGA housing. The cable lug must be secured by means of screw connection and retaining ring. The outer ground terminal of the VEGA instrument must be connected acc. to IEC 60079-14 chapter 16.3 (edition 2013) to the local potential equalization. 6 Overvoltage protection B81-35

1 3 2 1 Overvoltage arrester B81-35 2 Green-yellow protective ground cable with cable lug 3 Internal ground terminal 9 Isolation voltage against earth, test of the dielectric strength The intrinsically safe input/output circuit is ground-free. The breakdown voltage of the overvoltage arrester B81-35 between intrinsically safe circuit and ground terminal is less than 500 V AC due to construction reasons. With a metrological test of the absence of ground of intrinsically safe circuits against ground acc. to IEC 60079-25, the overvoltage arrester must be removed. Overvoltage protection B81-35 7

Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2016 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com