Thermo Scientific Niton XL2 GOLDD Series Environmental Analyzers Elemental Limits of Detection in SiO 2 and SRM Matrices Using Soil Analysis In addition to the offices listed below, Thermo Scientific Niton Anaylzers maintains a network of sales and service organizations throughout the world. Americas Billerica, MA USA US Toll Free: 800 875-1578 +1 978 670 7460 niton@ Europe, Middle East, Africa & South Asia Munich, Germany +49 89 3681 380 niton.eur@ Asia Pacific Central, Hong Kong +852 2869 6669 niton.asia@ www.thermoscientific.com/niton 2010 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. AN44823 07/2010 The Niton XL2 GOLDD Series x-ray fluorescence (XRF) analyzer is the performance choice for your toughest testing applications. Where low detection limits and high sample throughput are critical, our combination of hardware, software, and direct industry experience are combined to provide you with a solution to your most difficult analytical requirements. The chart below details the sensitivity, or limits of detection (LODs) 1, of the Niton XL2 GOLDD using Soil Analysis Mode for an SiO 2 matrix, a typical soil matrix (SiO 2 with Ca/Fe), and SRM matrix. Soil Analysis Mode offers optimum performance for low levels of RCRA metals and other contaminants/constituents found in soil/sediment type samples. LODs are calculated as three standard deviations (99.7% confidence interval) for each element for a 120-second total analysis time. Elements Limits of Detection in ppm (mg/kg) Time 60s per filter Matrix SiO 2 SiO 2 +Fe+Ca SRM Ba 55 65 65 Sb 20 25 22 Sn 20 25 22 Cd 10 12 12 Ag A/S A/S A/S Pd 8 8 8 Zr 10 12 13 Sr 4 6 10 Rb 4 4 7 Pb 7 12 10 Se 4 5 5 As 5 10 8 Hg 7 10 8 Au 10 12 12 Zn 8 16 16 W 50 75 75 Cu 14 20 20 Ni 30 40 40 Co 25 125 125 Fe 40 N/A N/A Mn 40 70 90 Cr 70 90 100 Ti 650 750 1000 Element list shown is not exhaustive. For limits of detection for elements not shown, please contact a Thermo Fisher Scientific office or your local representative. Limits of detection (LODs) are dependent on the following factors: Testing time Interferences/matrix Level of statistical confidence Please Note: Ongoing research and advancements in our Niton XL2 Series analyzers with geometrically optimized large area drift detector (GOLDD) technology will lead to continual improvement in many of the values detailed in this chart. Contact a Thermo Fisher Scientific office or your local representative for the latest performance specifications. Actual analysis time is based on your requirements, and, in most cases, shorter times will give you the detection limits you require. For example, if analysis time was reduced from 60 seconds/filter to 15 seconds/filter, then the detection limits obtained would be twice the values shown in the chart. Similarly, increasing the analysis time will reduce the detection limits by the square root of the increased time. A/S = Application-specific N/A = Not applicable 1. Definition and Procedure for the Determination of the Method of Detection Limit, 40 CFR, Part 136, Appendix B. Revision 1.11. U.S. Environmental Protection Agency. U.S. Government Printing Office: Washington, DC, 1995.
PORTABLE ANALYTICAL INSTRUMENTS Thermo Scientific Niton XL2 GOLDD XRF Analyzer The performance leading solution from the pioneer in handheld XRF instrumentation. Product Specifications Thermo Scientific Niton XL2 GOLDD analyzers provide you with many distinct advantages: Light element detection (Mg, Al, Si, P, S) without helium purge vacuum From turn on to trigger pull to near instantaneous results Very easy to use even by non-technical personnel Rugged design for the most challenging industrial environments Standard integrated camera for accurate positioning of analysis area Completely nondestructive test Premier Performance in a Value Package The performance-leading Thermo Scientific TM Niton TM XL2 GOLDD analyzer offers premier performance and advanced electronics while maintaining the point-and-shoot simplicity that is the hallmark of all of our x-ray fluorescence (XRF) instruments. With our groundbreaking GOLDD technology, your analytical capabilities are taken to a whole new level. The direct benefits to you include: real-time results, light element analysis, and advanced performance in our value package. The Niton XL2 GOLDD analyzer also includes a standard integrated camera to ensure accurate positioning on the area of interest to capture and store an image for review or inclusion in reports. Ergonomically designed and featuring daylight-readable icons, the Niton XL2 GOLDD incorporates customizable menus, multiple language options, and a standard analytical range of up to 30 elements from magnesium to uranium. Sealed against moisture and dust with 100% embedded software tools, these analyzers are lightweight yet ruggedly built to withstand the harshest environments in the field or on the shop floor. The GOLDD Advantage GOLDD technology delivers vast improvements in sensitivity or measurement times as much as 10-times faster than conventional Si-PIN detectors and up to 3-times more precise than conventional silicon drift detectors (SDD). We achieved this improvement by combining the Niton XL2 GOLDD 45kV, 100 μa x-ray tube, closely optimized geometry, and patented signal processing hardware and software. These advantages are coupled with our drift detector, one of the largest area drift detectors that is commercially available in a handheld XRF analyzer, providing you with superior performance in the form of faster analysis and lower detection limits. The final product is the Niton XL2 GOLDD a more versatile and technologically advanced handheld XRF analyzer, designed without compromise to make you more successful.
Niton XL2 GOLDD: Large area drift detector and optimized geometry for more x-ray counts gives you faster and more precise readings. With its unparalleled accuracy, you can be confident that the Niton XL2 GOLDD won t misidentify value, grade, or residuals. The Niton XL2 GOLDD stands alone with its many standard features and available options. By utilizing the standard Thermo Scientific Niton Data Transfer (NDT ) PC software suite to customize the instrument, you can set operator permissions, generate custom reports, print certificates of analysis personalized with your own company logo, or remotely monitor and operate the instrument hands-free from your PC. Integrated USB and Bluetooth communications provide direct data transfer to your PC or networked storage device, eliminating the cumbersome data synchronization procedures required by Windows Mobile -based XRF analyzers. Niton XL2 GOLDD Analyzers Whether you need an analyzer for metal alloy analysis, mining operations, or environmental screening, the performance-leading Niton XL2 GOLDD provides cost-effective high-speed performance, point-and-shoot simplicity, integrated camera, and the cutting-edge technology that you have come to expect from industry-leading Thermo Scientific Niton XRF analyzers. Thermo Scientific Niton XL2 GOLDD Specifications Weight 3 lbs 5.8 oz (1.53 kg) Dimensions 10.25 x 11 x 4 in. (256 x 275 x 100 mm) Tube Ag anode 45 kv maximum, 100 ua maximum Detector Geometrically Optimized Large Area Drift Detector (GOLDD) System Electronics 400 MHz ARM 11 CPU 300 MHz dedicated DSP 80 MHz ASICS DSP for signal processing 4096 channel MCA 64 MB internal system memory/128 MB internal user storage Display Fixed angle, color, touch-screen display Standard Analytical Range Up to 30 elements from Mg to U (varies by application) Data Storage Internal >10,000 readings with spectra Data Transfer USB, Bluetooth, and RS-232 serial communication Security Password-protected user security Mode Alloy Modes: Metal Alloy, Electronics Alloy, Precious Metals (Varies by application) Bulk Modes: Mining, Soil Plastic Modes: RoHS Plastics, Toy & Consumer Goods Plastics, TestAll, Painted Products Limited Custom Modes: Upon request (based on application feasibility) Data Entry Touch-screen keyboard User-programmable pick lists Optional wireless remote barcode reader Standard Accessories Integrated camera Locking shielded carrying case Shielded belt holster Two 6-cell lithium-ion battery packs 110/220 VAC battery charger/ AC adaptor PC connection cables (USB and RS-232) Niton Data Transfer (NDT) PC software Safety lanyard Check samples/standards Optional Features and Accessories Engine Guard protects critical detection components and minimizes operational downtime Thermo Scientific portable test stand, stationary (bench-top) stand, mobile test stand, Thermo Scientific Field Mate Welding mask Soil testing guard Licensing/Registration Varies by region. Contact your local distributor. Compliance CE, RoHS Product Specifications Thermo Scientific Niton XL2 GOLDD analyzers represent just one of our handheld analyzer solutions, which include XRF tools for metal alloy identification, mining and exploration, lead-based paint testing, RCRA metals in soil, toy and consumer goods testing, RoHS and WEEE compliance screening, and many other analysis needs. www.thermoscientific.com/portableid 2015 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Americas Boston, USA +1 978 642 1132 niton@ Europe, Middle East, Africa Munich, Germany +49 89 3681 380 niton.eur@ India Mumbai, India +91 22 6680 3000 ininfo@ Asia Pacific New Territories, Hong Kong +852 2885 4613 niton.asia@ 10/2015
Thermo Scientific Niton XL2 GOLDD Series Analyzers Consumer Goods Screening Elemental Limits of Detection in Polymers In addition to the offices listed below, Thermo Scientific Niton Anaylzers maintains a network of sales and service organizations throughout the world. Americas Billerica, MA USA US Toll Free: 800 875-1578 +1 978 670 7460 niton@ Europe, Middle East, Africa and South Asia +49 89 3681 380 niton.eur@ Asia Pacific Central, Hong Kong +852 2869 6669 niton.asia@ www.thermoscientific.com/niton 2010 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. The Niton XL2 GOLDD Series x-ray fluorescence (XRF) analyzer is the performance choice for your toughest testing applications. These purpose-built instruments for consumer goods analysis utilize a proprietary Fundamental Parameters (FP)-based routine and Thermo Scientific TestAll technology for quick and accurate results on plastics, polymers, and metal alloy samples, including solders, with no user input. The chart below details the sensitivity, or limits of detection (LODs) 1 of the Niton XL2 GOLDD Series for specific polymer matrices. LODs are calculated as three standard deviations (99.7% confidence interval) for each element for a 30-second total analysis time. Elements Limits of Detection in ppm (mg/kg) Time 30s / filter Matrix PE PVC Ba 150 N/A Sb 30 35 Sn 30 35 Cd 16 20 Bi 8 25 Pb 8 20 Br 5 25 Se 5 25 As 5 25 Hg 8 40 Au 8 40 Zn 12 80 Cu 15 80 Ni 15 80 Fe 20 125 Cr 30 110 V 200 1200 Ti 150 1500 Cl 50 N/A Element list show is not exhaustive. For limits of detection for elements not shown, please contact a Thermo Fisher Scientific office or your local representative. Limits of detection (LODs) are dependent on the following factors: Testing time Interferences/matrix Level of statistical confidence Please Note: Ongoing research and advancements in our Niton XL2 Series analyzers with geometrically optimized large area drift detector (GOLDD) technology will lead to continual improvement in many of the values detailed in this chart. Contact a Thermo Fisher Scientific office or your local representative for the latest performance specifications. Actual analysis time is based on your requirements, and, in most cases, shorter times will give you the detection limits you require. For example, if analysis time was reduced from 60 seconds to 15 seconds, then the detection limits obtained would be double the value. Similarly, increasing the analysis time will reduce the detection limits by the square root of the increased time. N/A = Not applicable 1. Definition and Procedure for the Determination of the Method of Detection Limit, 40 CFR, Part 136, Appendix B. Revision 1.11. U.S. Environmental Protection Agency. U.S. Government Printing Office: Washington, DC, 1995. AN44824 07/2010