INSTALLATION INSTRUCTIONS

Similar documents
Omni Marine Tel: +44(0) e:

ALGAEFREE Marine 300 PRO SERIES

FDMA MARINE SURGE PROTECTIVE DEVICE

C-POWER AC AUTOMATIC CONTROL

Model HM-535 Power Supply Installation and Service Instructions

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

FUSION MS-RA70/MS-RA70N Installation Instructions

The world leader in trim tab, electric propulsion system, & hatch lift innovation OWNER S MANUAL. Lenco Drive ELECTRIC PROPULSION

Sigma XT Ancillary Board (K588)

Integrated Battery Control System LBCS Step-by-Step Setup Guide

The world leader in trim tab, electric propulsion system, & hatch lift innovation OWNER S MANUAL. Troll n Tabs ELECTRIC PROPULSION

NBF-3. User Manual. NMEA 0183 Buffer. For all variants: NBF-3-BAS, Rev A. Issue 1.01

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

PT230 PONTOON THRUSTER INSTALLATION MANUAL (PATENT PENDING) VOLUME 1.2, JUNE 2015

Satellite INSTALLATION GUIDE

MS30. Owner s Manual + FOLDER VOL+ VOL- >ll MUTE. >>l. l<< MS30 MODE FOLDER

Electrical Specifications

NMEA Multiplexer Owner s Handbook. Document Number: Date: February 2005

Introduction Thank you for choosing our Fish Finder and welcome to the innovations of Condor Electronics!

Model volt to 24 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

Liebert XDA Air Flow Enhancer. User Manual

1 Quickstart Guide 1

Irrigation Control. Quick Start Guide Version 2c. Using Soil Moisture Sensors. Delta-T Devices Ltd

Instruction Manual

ICS Entrance Management Sign Installation Guide. Version 1.0

Installation Instructions

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Software... pg3 File Maintenance Training

poly-planar Marine Audio System

SCM030. MPPT Solar System Controller With. DC to DC Booster Input. Installation & Operating Instructions

Manual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics

Weathersafe Vision. Installation & Operating Instructions

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Albatross Control System Installation

EH50 ATTENTION: SECURITY COVERS ARE NO LONGER INCLUDED IN THE HEADREST KITS AS OF

MOBILE SAFETY DVR1543K. CLIP ON REARVIEW MIRROR KIT with 4.3-INCH LCD MONITOR FRONT & REAR CAR CAMCORDER with DUAL MOUNTING REVERSING CAMERA

Environdata FA ma Converter Guide

CMSA-100 Manual. Cinema Media Server Automation

Replacing the Power Supply

Smart Switch. Quick Start Guide

Sapling Converter Box

MULTIPOWER MANUAL. Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria / Europe

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

Haze 800 DMX. User Guide. English

DMC-1000 Chassis-Based Media Converter

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Disconnect the battery to ensure there will be no shorted wires during the installation procedure.

MULTI-FUNCTION DISPLAYS A3416: 8 INCH / A3417: 13.3 INCH

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

OV-MCR116. Media Converter Chassis System. User s Manual

MAXIMA+ Series Rotary Level Indicator

Enphase S-Series Microinverter and Engage Cable Safety

Level sensor for monitoring the level of liquid media

( GRAY CONTROL BOX )

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

360 Imaging Installation Guide

Pub X510C & X515C DF. Fish-finding and Depth Sounding Sonars. Operation Instructions

Pressure switches and thermostats, types KP and KPI

RV CONTROL AND MONITORING SYSTEM Installation and Operation Manual. Patent # US 9,679,735

MAXIMA + Series ROTARY LEVEL CONTROL

RADIO-POWER INTERFACE

7 Day Digital Programmer 2 Channel Surface Mount

2.1 MANAGEMENT UNIT INSTALLATION

INSTRUCTION MANUAL FN-8118 SCAN HERE

DDW36A Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

B60 Domestic Voltage Optimisation Unit

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

Rexroth Controller Installation & Operations Manual

DMK 11A & 11A GPS Owners Manual

Series ULT Ultrasonic Level Transmitter

OSSI Sonic Wave Sensor XB User Manual

Manual Control Unit GFC 32

AWP-24 Wave Height Gauge User's Guide

Users Manual Ocean Sensor Systems Wave Staff III

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Model XAV2 & XAV2-LED System Installation

Vac-U-Cam. R/C Camera Boat Hull Kit. Length: 22.5 in. Beam: 7 in. Draft: 2-3/8 in. Displacement: 4 lb.

Immersion Temperature Sensors

Stalking the Elusive and Somewhat Strange PV System

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Rear Camera System Owner s Manual

S-100X / S-200X Snow Machine User Manual

SERIES 200. k POWER DISTRIBUTION PANEL SERIES 200

Smart Battery Box Owner s Manual & Safety Instructions

HT2000 Transverter Installation & Operation Manual

PSU Installation and Setup Guide for the VARIO PSU

PrintPAD MC65. User Guide

HIPP Endoskop Service GmbH >> your requirements are our aims. HIPP Video Borescope Series VB. Technical Product Information

Basic User and Installation Manual

ORB TM 4-20 ma Input Box Installation & Operation Manual

Model SR411i-KG Patient Floor Scale Service Manual Part No. MAN411i-KG_ Page 1 of 16. Patient Floor Scale. Operating and Service Manual

Girard Awnings R ACMC Motor Controller (Last revised on May 10, 2008) A Visionary Awning Control by

EWCH 485 Electronic Pulse Counter

Sonic Meter SM1000. Operating Manual. 2-00, 1-11, Rev 1.1

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

NEBULA X USER MANUAL. Redefining Tradition. Read carefully before using the device and save these instructions.

PO Box 409 Hanover, MD TEL (410)

Transcription:

INSTALLATION INSTRUCTIONS Wave Goodbye to Barnacles with CITADEL ULTRASONIC MARINE SAFETY Exercise caution when working on the vessel, especially in confined spaces or when working near the bottom or bilge area of the boat. Make sure the work area is properly ventilated prior to beginning installation. These areas may contain residual fuel or fumes that can be harmful when inhaled. Extreme vigilance should be used in these spaces especially when working alone. A basic understanding of drilling, sanding and the vessel s electrical system are needed for the installation work required. The equipment must be installed in accordance with the instructions in this handbook. Failure to do so could result in poor product performance, personal injury and/or damage to the vessel. The success and performance of the system depends on a quality installation. CLEANING OF THE HULL It is important to clean the hull close to the time of the installation. Barnacles and mussels, are not killed by this system. This system kills the micro-organisms at the bottom of the food chain. Algae and other vegetation are killed and consequently the barnacles & mussels that feed on them will not attach to the hull. ITEMS SUPPLIED Included in this box: Control Box Unit AF101C Transducers from 1 to 4 AF101T as ordered Transducer cables 1 RG59A coaxial cable for each transducer ordered 5m or10m Two cable glands 12mm

Options if ordered: AC shore power supply AF101PS110/230 24V DC power supply AF101PS24 to allow use from 24 volt DC ships supply. INSTALLATION Planning & Positioning Before beginning work it is important to plan out the installation, taking note of: The vessels hull design. Location for the transducers and control box. Cable runs and power supply. Location of Control Box The control box is sealed and water resistant so can be installed in the most convenient location, preferably above the water line. The length of cables to the transducers should be taken into consideration for the location of the control box. Hull Construction Ultrasonic sound waves will only work properly on fiberglass, aluminium and steel hulls. The system is not suitable for wooden hulls. Hull Mounting Transducers must be bonded directly to the hull of the boat. Special care must be taken to ensure that they are not bonded to a false floor, cavity, over a keel, or on the inner layer of a balsa/foam cored boat. A direct connection to the hull may require removing any spacing or other layer such as a sandwich foam or balsa core. If working with steel or aluminium, be sure not to connect over welds or seams in the material. Obstructions Avoid mounting transducers close to any objects such as stringers, bulkheads, water tanks, fuel tanks, transoms, depth finder and fish finder. Ideally, they should be 30 cms away from these areas for the system to operate most effectively.. Transducer Positioning The diagrams below show the general optimum areas for mounting transducers, since every vessel is different. The illustration should be used as a general guide only. On smaller power craft under 10m, the transducer should be positioned in the close proximity of the propeller and shaft to help protect these isolated parts. Transducers should be fitted onto a solid part of the hull, see under hull mounting above. They should also be approximately 30cms off the centre line. For stern drive units, transducers should also be approximately 10 to 13cms forward of the transom. These measurements are a guide only, but the surrounding structures in the vessel will determine the final position. A reasonably flat area of the hull should be chosen for transducer locations and the surface should be well prepared before mounting (see preparation and mounting instructions below).

Typical Position Sailboat:

Typical Position Power Boat:

Installing the Control Box The control box is splash proof to IP66 and can be installed in any convenient location, preferably above the water line. 1. Unscrew the four screws on the cover of the control box. These screws will not un-screw completely, as they are designed to stay with the cover. Remove the cover and place it aside. 2. The mounting screws are placed in the same holes as the cover screws. Use four suitable screws to secure the control box. 3. Mark the location for the four corner mounting screws. Using a drill bit, drill the mounting holes. Use caution to make sure that you are not drilling into the hull of the boat. 4. Locate the 12 volt DC power source. This can be either a protected circuit from the vessels electrical panel, or it can be direct to the battery via a local 5 amp fuse or circuit breaker. Use stranded cable rated at 5 amps or more. Leave switched off until testing the installation. 5. Connect cable from terminal A, negative and B, positive via the supplied cable gland to a suitable permanently on, protected 12 volt DC supply. 6. IMPORTANT! When using optional shore power, connections should be made to the terminal block marked C, negative and D, positive. When the optional AC shore power supply AF101PS110/230 converter is ordered, power will automatically be taken from the shore supply and not the battery. 7. Replace the control box cover. For operation from a solar panel, contact us for advice.

Mounting the Transducer to the Hull When mounting transducers, the goal is to make 100% contact between the transducer and the hull. The better you prepare the surface, the better the result. To make a neat and tidy installation, proceed as follows:- 1. Degrease the general area where mounting the transducer and also degrease the face of the transducer using either isopropyl alcohol, methylated or surgical spirit. 2. Draw a pencil circle around base of transducer as photograph number one below, abrade hull within this circle using medium grade sandpaper. Mask around circle as in the photograph two below. Also mask lower part of the transducer. 3. Mix approximately 2 tablespoons of Isopon P38 and apply to base of transducer, avoiding air pockets. Place transducer in center of masked area and push down hard to expel surplus Isopon. Masking tape should be used during bonding to keep the transducers in place on sloping parts of the hull. After about three minutes, depending on temperature, run around perimeter of transducer with a sharp pointed blade and ease surplus away. 4. Allow 2 hours for Isopon to set before removing the masking tape which should come away with the surplus Isopon. Take care not to disturb transducer during the above process while the Isopon sets. 1 2 Installed transducer Running the Transducer Cables Having mounted the transducers and control box, the cables can now be connected to the units. Up to four transducers can be connected to a single control box.

Maximum 10m cable length per transducer. Testing and Operation With the control box closed, connect and turn on the power supply. Two status LEDs are viewable through the cover of the control box and indicate the following: Green flashing LED indicates correct operation of the control box. Red flashing LED indicated battery voltage is low and transducers switched off to save on battery usage. LED light on the transducers indicate the following: Green flashing indicates transducer is working. Technical Support If your system is not working and you are unable to resolve the problem, Please contact us at vic@citadelproducts.com for help. Issue 2.4 August 2016