NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

Similar documents
NX-EC0/ECS/PG0 CSM_NX-EC0_ECS_PG0_DS_E_2_2

NX-TS. NX-series Temperature Input Unit

CSM_NX-PG0 DS_E_4_4

NX-DA CSM_NX-DA_DS_E_3_1

NX integrated safety System configuration. Integrated safety into machine automation

NX-SL/SI/SO. NX-series Safety Control Units. Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration.

CSM_NX-RS DS_E_5_2

CSM_NX-HAD DS_E_DITA_2_1

CSM_NX-HAD_P253I-E-01

NX-series Temperature Control Unit NX-TC

NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_4

Built-in EtherCAT port. Communications cable Ethernet cables. Peripheral USB port. Connection to peripheral USB port on EtherCAT Coupler Unit

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

NX-EIC CSM_NX-EIC_DS_E_1_1

CSM_NX-ECS_DS_E_3_4

NJ-Series Power Supply Unit NJ-PA/PD

NX-ECC CSM_NX-ECC_DS_E_8_6

NX safety control System configuration. Integrated safety into machine automation

NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_5

NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_3

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Sub-trunk line Terminating Resistance Repeater Unit. Branch Line Repeater Unit. Sub-trunk line. Terminating Resistance.

EtherCAT Coupler Unit. I/O power supply

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4

NX-series Pulse Output Unit

NX-Series Modular I/O System

NX-ILM400. NX-series IO-Link Master Unit

Communication & Networking

NX-EIC CSM_NX-EIC_DS_E_3_3

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Programmable Relay ZEN V2 Units

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

EtherCAT Remote I/O Terminal GX series

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

CJ1W-PTS/PDC/PH41U/AD04U

Safety Relay Unit (I/O Unit Type)

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Trajexia motion controller

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Appendix G. CJ1W-CIF11 RS-422A Converter

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Solid-state Timer H3YN

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

SmartSlice I/O Plug-and-Play I/O. System Configuration

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Power and Expansion Selection

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Trajexia motion controller

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

em4 Accessories Digital expansions

Communications & Networking

CompactBlock Guard I/O EtherNet/IP Safety Modules

Classification Enclosure rating Input voltage Type of

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Visualize the actual worksite status! Simple and Intelligent I/O Slave Units.

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

Power Monitors KM-N2 / KM-N3

Appendix 3 Using NS-AL002 Converters

Model Number Structure

About the Manual. ST-3400 Series Installation Guide. Package Contents

FLEX Ex Spring Clamp Terminal Base

Trajexia Motion Controller

F150 Vision Controller with integrated PROFIBUS-DP unit. 9-pin female sub-d connector (RS-485 ProfiBus) Bus termination

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

CPU Units with 20 I/O points

CJ1W-FLN22. CJ-series FL-net Unit. Connect to Multivendor Controller Networks. Features

Model Number Structure

About the Manual. ST-3300 Series Installation Guide. Package Contents

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

NE1A/DST1. DeviceNet Safety System

SYSMAC Remote Transistor Module

Programmable Logic Controllers

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

SmartSlice. System Configuration

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Inductive Proximity Sensor

Module 18plus. Description. 18plus

S8VE (60/90/120/180/240-W Models)

CJ1W-FLN22 CSM_CJ1W-FLN22_DS_E_3_1

Despite its ultra-slim design, a CPM2C system can provide up to 192 I/O points!

Model Number Structure

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Transcription:

NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine Automation Controller. Encoder data can be synchronised with the control cycle and EtherCAT Distributed Clock. Features SSI clock frequency is supported up to 2 MHz. Free-run refreshing or Synchronous I/O refreshing can be selected for refreshing with the NX-series EtherCAT Coupler. When the MC Function Modules of the NJ-series Machine Automation Controller are used, the encoder input can be used for motion control instructions as an axis. Choice of SSI Coding Methods (No conversion, binary code, or gray code) Input edge time stamps Multi turn and single turn SSI encoders are supported. Data Refresh Status (Data refreshing can be checked on the host controller.) Maximum connecting SSI cable length:400m System Configuration Support Software (Sysmac Studio) EtherCAT master (NJ-series CPU Unit) Connection to the peripheral USB port or built-in EtherNet I/P port on an NJ-series CPU Unit EtherCAT communications cable SSI Input Unit EtherCAT Coupler Unit I/O power supply SSI encoder *1 *1. The SSI encoder is supplied with 24-VDC power from the SSI Input Unit. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT is a registered trademark of Beckhoff Automation GmbH for their patented technology. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 1

Ordering Information International Standards The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: culus, UC1: culus (Class I Division 2 Products for Hazardous Locations), CU: cul, N: NK, L: Lloyd, CE: EC Directives, and KC: KC Registration. Contact your OMRON representative for further details and applicable conditions for these standards. Unit type NX Series Position Interface Unit Product Name SSI Input Units Number of channels 1 2 Input/Output form EIA standard RS-422-A EIA standard RS-422-A Specification Maximum data length Encoder power supply 32 bits DC24V, 0.3A/CH 32 bits DC24V, 0.3A/CH Type of external connections Screwless push-in terminal block (12 terminals) Screwless push-in terminal block (12 terminals) Model NX-ECS112 NX-ECS212 Standards UC1, CE, KC UC1, CE, KC Option Product Name Specification Model Standards Unit/Terminal Block Coding Pins Accessories Not included. For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) NX-AUX02-2

General Specification Enclosure Item Mounted in a panel Grounding method Ground to less than 100 Ω Ambient operating temperature 0 to 55 C Ambient operating humidity 10% to 95% (with no condensation or icing) Operating environment Atmosphere Ambient storage temperature Altitude Applicable standards Must be free from corrosive gases. 25 to 70 C (with no condensation or icing) 2,000 m max. Specification Pollution degree Pollution degree 2 or less: Conforms to JIS B3502 and IEC 61131-2. Noise immunity Conforms to IEC61000-4-4, 2 kv (power supply line) Overvoltage category Category II: Conforms to JIS B3502 and IEC 61131-2. EMC immunity level Vibration resistance Shock resistance Zone B Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s 2, 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Conforms to IEC 60068-2-27. 147 m/s 2, 3 times each in X, Y, and Z directions culus: Listed UL508 and ANSI/ISA 12.12.01 EC: EN 61131-2 and C-Tick, KC Registration 3

Specification SSI Input Units 1 channel NX-ECS112 Unit name SSI Input Units Model NX-ECS112 Number of channels 1 channel Type of external connections I/O refreshing method Free-Run refreshing or synchronous I/O refreshing *1 Screwless clamping terminal block (12 terminals) Indicators Input signals External inputs: 2 Data input (D+,D ) External outputs: 2 Clock output (C+, C ) I/O interface Clock output Data input Maximum data length Coding method Baud Rate Synchronized serial interface (SSI) EIA standard RS-422-A line driver levels EIA standard RS-422-A line receiver levels 32 bits (The single-turn, multi-turn, and status data length can be set.) No conversion, binary code, or gray code 100 khz, 200 khz, 300 khz, 400 khz, 500 khz, 1.0 MHz, 1.5 MHz, or 2.0 MHz Dimensions 12 100 71 mm (W H D) Isolation method Digital isolator Insulation resistance I/O power supply source NX Unit power consumption Maximum transmission distance *2 Weight 20 MΩ min. between isolated circuits (at 100 VDC) Supplied from the NX bus. 20.4 to 28.8 VDC (24 VDC +20%/ 15%) Dielectric strength Current capacity of I/O power supply terminals 0.85 W Current consumption from I/O power supply 20 ma Baud Rate Maximum transmission distance 100 khz 400 m 200 khz 190 m 300 khz 120 m 400 khz 80 m 500 khz 60 m 1.0 MHz 25 m 1.5 MHz 10 m 2.0 MHz 5 m 65 g SSI Clock Output and Data Input 510 VAC between isolated circuits for 1 minute with leakage current of 5 ma max. IOV: 0.3 A max. per terminal IOG: 0.3 A max. per terminal Terminal block C+ C- No isolation: 5 V Isolation circuit Internal circuits Circuit layout D+ D- 120 Ω No isolation: 5 V GND Left-side NX bus connector I/O power supply + I/O power supply Nonisolated power supply No isolation: 5 V No isolation: 5 V GND I/O power supply + I/O power supply Right-side NX bus connector Installation orientation and restrictions Installation orientation: 6 possible orientations Restrictions: There are no restrictions. Terminal connection diagram C+ C- IOV IOG NC NC D+ D- IOV IOG NC NC Encoder Failure detection None Protection None *1. The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit. *2. The maximum transmission distance for an SSI Input Unit depends on the baud rate due to the delay that can result from the responsiveness of the connected encoder and cable impedance. The maximum transmission distance is only a guideline. Review the specifications for the cables and encoders in the system and evaluate the operation of the equipment before use. 4

SSI Input Units 2 channel NX-ECS212 Unit name SSI Input Units Model NX-ECS212 Type of external Number of channels 2 channels connections I/O refreshing method Free-Run refreshing or synchronous I/O refreshing *1 Screwless clamping terminal block (12 terminals) Indicators Input signals External inputs: 2 Data input (D+, D ) External outputs: 2 Clock output (C+, C ) I/O interface Clock output Data input Maximum data length Coding method Baud Rate Synchronized serial interface (SSI) EIA standard RS-422-A line driver levels EIA standard RS-422-A line receiver levels 32 bits (The single-turn, multi-turn, and status data length can be set.) No conversion, binary code, or gray code 100 khz, 200 khz, 300 khz, 400 khz, 500 khz, 1.0 MHz, 1.5 MHz, or 2.0 MHz Dimensions 12 100 71 mm (W H D) Isolation method Digital isolator Insulation resistance I/O power supply source NX Unit power consumption Maximum transmission distance *2 Weight 20 MΩ min. between isolated circuits (at 100 VDC) Supplied from the NX bus. 20.4 to 28.8 VDC (24 VDC +20%/ 15%) 0.9 W Dielectric strength Current capacity of I/O power supply terminals Current consumption from I/O power supply 510 VAC between isolated circuits for 1 minute with leakage current of 5 ma max. IOV: 0.3 A max. per terminal IOG: 0.3 A max. per terminal 30 ma Baud Rate Maximum transmission distance 100 khz 400 m 200 khz 190 m 300 khz 120 m 400 khz 80 m 500 khz 60 m 1.0 MHz 25 m 1.5 MHz 10 m 2.0 MHz 5 m 65 g SSI Clock Output and Data Input Terminal block No isolation: 5 V C1+, C2+ C1-, C2- Isolation circuit Internal circuits Circuit layout D1+, D2+ D1-, D2-120 Ω No isolation: 5 V GND Left-side NX bus connector I/O power supply + I/O power supply Nonisolated power supply No isolation: 5 V No isolation: 5 V GND I/O power supply + I/O power supply Right-side NX bus connector Installation orientation and restrictions Installation orientation: 6 possible orientations Restrictions: There are no restrictions. C1+ D1+ Encoder C1- D1- Terminal connection diagram Encoder IOV IOG C2+ IOV IOG D2+ C2- D2- Failure detection None Protection None *1. The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit. *2. The maximum transmission distance for an SSI Input Unit depends on the baud rate due to the delay that can result from the responsiveness of the connected encoder and cable impedance. The maximum transmission distance is only a guideline. Review the specifications for the cables and encoders in the system and evaluate the operation of the equipment before use. 5

Version Information Unit NX Series and Sysmac Studio SSI Input Unit NX Series Sysmac Studio Version 1.05 or lower Version 1.06 or higher NX-ECS112 Not supported Supported NX-ECS212 Not supported Supported 6

External Interface SSI Input Unit NX-ECS112/212 (B) (C) (A) Letter Item Specification (A) NX bus connector This connector is used to connect to another Unit. (B) Indicators The indicators show the current operating status of the Unit. (C) Terminal block The terminal block is used to connect to external devices. The number of terminals depends on the Unit. Terminal Blocks (A) (B) A1 A2 A3 A4 A5 A6 A7 A8 B1 B2 B3 B4 B5 B6 B7 B8 (C) 12 mm wide 16 terminals Letter Item Specification (A) Terminal number indication The terminal number is identified by a column (A and B) and a row (1 through 8). Therefore, terminal numbers are written as a combination of columns and rows, A1 through A8 and B1 through B8. The terminal number indication is the same regardless of the number of terminals on the terminal block, as shown above. (B) Release hole A flat-blade screwdriver is inserted here to attach and remove the wiring. (C) Terminal hole The wires are inserted into these holes. 7

Applicable Wires Using Ferrules If you use ferrules, attach the twisted wires to them. Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules. Always use one-pin ferrules. Do not use two-pin ferrules. The applicable ferrules, wires, and crimping tool are given in the following table. Terminal types Manufacturer Ferrule model Terminals other than ground terminals Ground terminals Terminals other than ground terminals Phoenix Contact Applicable wire (mm 2 (AWG)) H1.5/16 *1. Some AWG 14 wires exceed 2.0 mm 2 and cannot be used in the screwless clamping terminal block. Crimping tool AI0,34-8 0.34 (#22) Phoenix Contact (The figure in parentheses is the applicable wire AI0,5-8 0.5 (#20) size.) AI0,5-10 AI0,75-8 0.75 (#18) CRIMPFOX 6 (0.25 to 6 mm 2, AWG 24 to 10) AI0,75-10 AI1,0-8 1.0 (#18) AI1,0-10 AI1,5-8 1.5 (#16) AI1,5-10 AI2,5-10 2.0 *1 Weidmuller H0.14/12 0.14 (#26) Weidmueller (The figure in parentheses is the applicable wire size.) H0.25/12 0.25 (#24) PZ6 Roto (0.14 to 6 mm 2, AWG 26 to 10) H0.34/12 0.34 (#22) H0.5/14 0.5 (#20) H0.5/16 H0.75/14 0.75 (#18) H0.75/16 H1.0/14 1.0 (#18) H1.0/16 H1.5/14 1.5 (#16) When you use any ferrules other than those in the above table, crimp them to the twisted wires so that the following processed dimensions are achieved. 8 to 10 mm 1.6 mm max. (Terminals other than ground terminals) 2.0 mm max. (Ground terminals) 2.4 mm max. (Terminals other than ground terminals) 2.7 mm max. (Ground terminals) Using Twisted Wires/Solid Wires If you use the twisted wires or the solid wires, the applicable wire range and conductor length (stripping length) are as follows. Use the twisted wires to connect the ground wire to a ground of 100 Ω or less. Do not use the solid wires. Terminal types Applicable wires range Conductor length (stripping length) Ground terminals 2.0 mm 2 9 to 10 mm Terminals other than ground terminals 0.08 to 1.5 mm 2 AWG28 to 16 8 to 10 mm Conductor length (stripping length) 8

Dimensions SSI Input Unit NX-ECS112/212 (Unit: mm) 14.1 12.0 1.5 100 1.5 65.2 71 80.1 104.5 Related Manuals Man. No Model Manual Application Description W524 NX-EC0@@@ NX-PG0@@@ NX-series Position Interface Units User s Manual Learning how to use NX-series Position Interface Units The hardware, setup methods, and functions of the NX-series Incremental Encoder Input Units, SSI Input Units, and Pulse Output Unit are described. 9