Electrical network management. Schneider Electric. EM4200 Technical Datasheet

Similar documents
PowerLogic EM4000 series

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Com X 210, Com X 510 Technical Datasheet

Communication Interface

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Communication Interface

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

PowerLogic power-monitoring units. iem3000 Series. Technical data sheet

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

Energy Management BUS Adapter Type VMU-B

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Energy Management BUS Adapter Type VMU-B 01

EM6400 series Multi-Function meters

MiCOM P111. Three phase and earth fault overcurrent relays

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

PowerLogic BCPM Functions and characteristics

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

MODULAR CIRCUIT MONITORING SYSTEM

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

PowerLogic High Density Metering System 1-Meter Enclosure

Energy Management Energy Transducer Type ET112

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Metering Devices IQ 300

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

SECTION SWITCHBOARDS

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

WM20. Power analyzer for three-phase systems. Benefits. Description

ECLYPSE Communication Modules

EM270. Multi-channel power analyzer. Benefits. Description

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

IntesisBox Modbus Server Panasonic

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Digital Multifunction Meters. Digital Multifunction Meters

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

MIC-2 MKII, Multi-instrument DATA SHEET

TM3SAF. Main. Device short name

Business continuity made easy

TM3TI4 module TM3-4 inputs temperature

MIC-2 Multi-instrument DATA SHEET

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

EM271. Multi-channel power analyzer. Benefits. Description

TM3AI4 module TM3-4 analog inputs

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ECLYPSE Communication Modules

Electrical network management. Schneider Electric. ION8650 Technical Datasheet

Schneider Electric Easy UPS 3S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

Power Meter PowerMonitor 500

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

TM3DI16 module TM3-16 inputs

TM3TI8T module TM3-8 inputs temperature

USER MANUAL 2012 V1.1

PMC 530 Series Advanced Multifunction Meter

ION8650 series Technical Datasheet

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

TM3TM3 module TM3-2 temperature inputs and 1 analog output

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Schneider Electric Easy UPS 3S

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

FU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

DIRIS Digiware D and C Communication and control power interfaces

Flair 21D - 22D - 23D - 23DM Self-powered, adjustment-free fault passage indicators

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

PM800 series. Applications

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

INTEGRA DIGITAL METERING SYSTEMS

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

NEMO HD MULTI-FUNC METER BASE (MF96001)

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Transcription:

Electrical network management Schneider Electric EM4200 Technical Datasheet

Functions and characteristics PB115451 EM4200 Series Enercept power and energy meters provide a unique solution for measuring energy data. Designed with the user in mind, the EM4200 Series offers maximum application flexibility for retrofit applications. The EM4200 Series is compatible with split-core, solid-core and U018 Series ropestyle Rogowski current transducers (CT) from five to 5000 amperes, often allowing installers to utilize existing CTs with the meter. Adding to its versatility, the EM4200 has a wide input range of 90 to 480 V AC, alleviating the need to keep multiple models in stock. The meter s small form factor enables installation in existing panels with limited space, and does not require external mounting or the expense of extra enclosures or conduit runs. Communicating models support auto detection of baud rate, parity, and protocol for Modbus RTU and BACnet MS/TP. With 75 percent of the buildings that will be occupied in 2050 having already been built and a large number of those not meeting today s strict energy codes and standards, a metering solution that can be easily installed and integrated into existing buildings is imperative. The EM4200 Series Enercept brings industry leading flexibility to power and energy monitoring, making it the ideal meter for retrofit applications. Features bbhigh reliability with ANSI C12.20 0.2% accuracy, IEC 62053-22 Class 0.2S 1/3 Volt Current Input Mode. ANSI C12.20 0.5% accuracy, IEC 62053-22 Class 0.5S Rogowski Current Input Mode. bbmodbus and BACnet protocols along with uni-directional and bi-directional feature sets in one unit simplifies ordering and stocking options. bbcompatible with CTs from 5 to 5000 A offers a wide range of service types. bb90 to 480 V AC application versatility with fewer models to stock. bbdin rail or screw-mount options, including mounting bracket, for easy installation. bbnative Modbus RTU and BACnet MS/TP support (no gateway) with serial rates up to 115.2 kbaud. bbseamless integration with StruxureWare Power Monitoring Expert (PME), StruxureWare Building Operation (SBO) and StruxureWare Building Expert (SBE). Main characteristics Compact, maintenance-free design Easy in-panel mounting Flexible connection The EM4200 is configurable with or without power. Easy communications connection Auto protocol, baud rate, and unidirectional or bi-directional detection. System integration Incorporates easily into existing systems without redesigning networks or wiring. No rewiring required Use existing wiring to connect to existing panels. Integrated communications networks. Onboard Ethernet or RS-485 allows for easy integration into existing communications networks. Commercial reference numbers Model Description Comm. ref. no. EM4235 Enercept, Class 0.2S meter, Modbus/BACnet METSEEM4235 communication, Uni-Directional/Bi-Directional, RS-485, IEC wire code, single circuit, Modbus/BACnet EM4236 Enercept, Class 0.2S meter, Modbus/BACnet communication, Uni-Directional/Bi-Directional, RS-485, ANSI wire code, single circuit, Modbus/BACnet METSEEM4236 2 plsed310121en

Functions and characteristics (cont.) PB115455 Selection guide EM4235 EM4236 General Use on LV systems b b Accuracy +/- 0.2% b b b b Accuracy compliance Maximum circuits: single-pole / single phase / three-phase ANSI C12.20 0.2% accuracy, IEC 62053-22 Class 0.2S 1/3 Volt Current Input Mode. ANSI C12.20 0.5% accuracy, IEC 62053-22 Class 0.5S Rogowski Current Input Mode 1, 2, or 3ph (A-B-C-N) b b Instantaneous rms values Energy real, kwh received/delivered b b reactive, kvarh received/delivered b b apparent, VAh b b Voltage L-L, L-N (3-phase Average and per Phase) b b Voltage and current V rms, I rms per phase b b Power real, reactive, apparent b b Power factor 3-phase Average and per Phase b b Measurements available for data logging Energy real, kwh received/delivered b b reactive, kvarh received/delivered b b apparent, VAh b b Voltage b b Communication Modbus RTU & BACnet MS/TP over RS-485 b b Installation options Screws b b Clip-on b b Hook b b DIN rail enclosure b b EM4200 parts descriptions and advantages The EM4200 Series Enercept was carefully designed for ease of installation, configuration, and operation. 1 Versatile mounting - DIN or screw mount. 2 Phase status - Visual indication of meter performance, tri-coloured LEDs simplify troubleshooting. 3 Meter status - Quick troubleshooting. 4 Settings override - Change the phase or direction through system software with exclusive Swizzle feature. 5 CT amperage rotary - Needed flexibility with CT support from 5 A to 5000 A. 6 Rotary dial setup - Configure with or without power, saving both time and labour costs. 7 Essential protocol support - Modbus, BACnet, and Uni-directional and Bi-directional measurement. plsed310121en 3

Functions and characteristics (cont.) Electrical characteristics Input-voltage Inputs characteristics Measured voltage Frequency range Mechanical characteristics Weight Dimensions V1, V2, V3, Vn 80-480 V AC L-L without PTs Up to 999 kv with external PTs 60 Hz approx. 4.0 kg 46.63 x 35.81 x 152.36 mm Environmental conditions Operating temperature -30 C to 70 C Storage temperature -40 C to 85 C Humidity rating 0% to 95 % RH non-condensing Enclosure Type 1 (indoor or enclosed outdoor use) Altitude 3000 m Pollution degree 2 Electromagnetic compatibility immunity to radiated fields, conforming to EN 61326-1 immunity to radiated fields, conforming to EN 61000-6-2 immunity to conducted disturbances, conforming to EN 61326-1 immunity to conducted disturbances, conforming to EN 61000-6-2 conducted and radiated emissions, conforming to EN 61326 + A1 conducted and radiated emissions, conforming to EN 61000-6-4 Pollution degree conducted and radiated emissions, conforming to FCC part 15 class A Safety and standards Certified to IEC/BTL CULus conforming to UL 61010-1 CE conforming to EN 61010-1 Communication Ports Modbus RTU & BACnet MS/TP over RS-485 Port protocols BACnet MS/TP : 9600 baud to115200 baud (automatic detection); Modbus RTU : 9600 baud to 115200 baud (automatic detection) 4 plsed310121en

Dimensions EM4200 dimensions PB115453 PB115452 PB115454 plsed310121en 5

Schneider Electric Industries SAS 35, Rue Joseph Monier, CS 30323 F - 92506 Rueil Malmaison Cedex RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com Product name PLSED310121EN As standards, specifications and designs develop from time to time, please ask for confirmation of the information given in this document. Design: Schneider Electric Photos: Schneider Electric Over 75 % of Schneider Electric products have been awarded the Green Premium ecolabel 2016 - Schneider Electric - All rights reserved 05-2016