PACSystems RX7i IC698CMX016-ED

Similar documents
PACSystems* RX3i IC695RMX228-ACAB Redundancy Memory Xchange Module

GE Fanuc Automation. PACSystems RX7i Memory Xchange Modules. Programmable Control Products. User's Manual

PACSystems RX7i IC698CHS009/119

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules

PACSystems* RX3i IC695PSA040

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

PACSystems* RX3i IC695PSA140

GE Fanuc IC695CMM004. Rx3i PacSystem

PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i IC694ALG232

VMIPCI-5565* Specifications

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

PACSystems* RX3i IC694ALG233

Programmable Controller IC697ACC721/724/744

PACSystems* RX3i IC695CMM002 and IC695CMM004

Shown with terminal block Supports diagnostic point fault contacts in the logic program

VMIPCI-5565 Specifications

PACSystems* RX3i IC695PBM300

PACSystems RX3i IC695PSA140

PLC Racks IC697CHS782/783

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

A PACSystems RX3i Ethernet NIU I/O Station

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

Analog Input, 16-Bit Thermocouple Module

PACSystems* RX3i Central Processing Unit IC695CPE302 Quick Start Guide GFK-3038 February 2018

VersaMax* Analog Input, 16-Bit Thermocouple Module

- Data exchange using configuration-based and logic-based Ethernet Global Data

GE Intelligent Platforms

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

PACSystems* RX3i Central Processing Unit IC695CPE305 Quick Start Guide

PACSystems* RX3i CANopen Master Module, IC695CNM001 Quick Start Guide, GFK-2837 March 2013

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Instructions to printer DO NOT PRINT THIS PAGE

Series Specialty PLCs

PACSystems RX3i IC695HSC304 and IC695HSC308

GFK-2372L September 2015

PACSystems RX3i IC695NIU001

PACSystems* RX3i IC695HSC304-DA and IC695HSC308-DA

PACSystems RX3i IC695CPU310

Overview. Features CHAPTER

IMPORTANT PRODUCT INFORMATION

PACSystems* RX3i CEP IC695CEP001

VMIACC-5595 Specification

PACSystems RX3i Controllers

PACSystems* RX3i IC695PNC001-AD

Specifications FOX Matrix 3200/7200/14400/320x Series, SMX 88/1616 FOX

This Datasheet for the IC697CMM741. Series MMS or TCP/IP Ethernet LAN Interface.

GE Intelligent Platforms. Programmable Control Products. PACSystems* RX7i. Installation Manual, GFK-2223H

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

VersaMax* IC200PNS001, IC200PNS002

QuickPanel View & QuickPanel Control

Chapter 1. Introduction. Additional Documentation

PACSystems* RX3i IC695ACC650

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

GE Fanuc Automation Programmable Control Products. PACSystems RX7i. Installation Manual, GFK-2223G. September 2006

Fiber Optic Selector Guide for PLC & Serial Communication Networks

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

Non-Isolated Analog Output Module with HART Communications, IC695ALG728-DC Non-Isolated Analog Output Modules, IC695ALG704-DC, IC695ALG708-DC

PACSystems RX3i IC695CPU310. Central Processing Unit. Features. Ordering Information. GFK-2329AC May 2011

308FX2-N. Phone: Fax: Web:

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

317FX-N. Phone: Fax: Web: -

Hardened Media Converter

ProCurve Switch 1400 Series

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

PT-7728/7828 Quick Installation Guide

PACSystems* RX3i 1GHz 64MB CPU w/ethernet IC695CPE330 Quick Start Guide GFK-2941J November 2018

GE Fanuc IC694ALG221. Rx3i PacSystem

Black Box Tech Support: FREE! Live. 24/7.

Features and Benefits. Certifications

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

114FX6. Phone: Fax: Web: -


imc2f Features Industrial IEC Ethernet to Fiber Media Converter Tel: Fax:

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

Features and Benefits. Certifications

Discrete Output Modules

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

PIX 520. PIX 520 Product Overview CHAPTER

Important Product Information

imc2g Features Introduction Industrial Gigabit Ethernet to Fiber Media Converter Tel: Fax:

PACSystems RX3i IC695CPU310. Features. Ordering Information. Central Processing Unit. GFK-2329T December 18, 2007

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

Industrial Switches Industrial Switches

IC695ALG608, IC695ALG616

PTC-101 Quick Installation Guide

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

VersaMax* Serial Communications Module

PIX 535. PIX 535 Product Overview CHAPTER

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules

Transcription:

May 10, 2010 PACSystems RX7i IC698016-ED Control Memory Xchange Module The Control Memory Xchange () module provides deterministic sharing of data among PLCs and other computing devices on a high-speed fiber optic network, using reflective memory technology. A reflective memory network can contain up to 256 nodes. Each node in the network can be any reflective memory device that is compatible with the 5565 family. When data is written to one node, all nodes on the network are automatically updated with the new data. Each node in the reflective memory network is connected in a daisy-chained loop using fiber optic cables. The transmitter of the first node is tied to the receiver of the second. The transmitter of the second node is tied to the receiver of the third node, and so on, until the loop is completed back at the receiver of the first node. The figure on page 3 shows an example of a six-node reflective memory network. A PACSystems RX7i main rack supports a maximum of four Memory Xchange modules. Features PACSystems RX7i single slot form factor. 16 Mbytes reflective memory with parity. Software configuration of all node parameters (no jumper or switch settings required). High-speed easy-to-use 2.12 Gbaud fiber-optic network. No RX7i processing required to operate the network. Network-compatible with VMIC 5565 family of reflective memory devices. Connection with multimode fiber up to 300m/984.25ft. Dynamic packet sizes of 4 to 64 bytes, controlled by the Memory Xchange module. Maximum network transfer rate of 43 Mbyte/s (4 byte packets) to 174 Mbyte/s (64 byte packets) Programmable VMEbus interrupt output. Four general-purpose network interrupts with 32 bits of data each. Network error detection. Up to 256 nodes per network. Redundant transfer mode operation. This optional mode reduces the chance of a data packet being dropped from the network. Configurable network memory offset allows you to assign nodes on a network to groups according to the 16MB segment in the network address space that they use. OK CONFIG OWN DATA SIGNAL DETECT TX RX

2 Control Memory Xchange Module Release Information Release History Part Number Hardware Version Firmware Version IC698016-ED E D IC698016-DC D C IC698016-CB C B IC698016-BA B A IC698016-AA (Initial Release) Updates A IC698016 modules with versions -BA and earlier cannot be upgraded in the field. These modules must be returned for replacement. Customers can upgrade IC698016-CB and -DC versions to version -ED by ordering and installing upgrade kit 44A753080-G02. All Conformal Coated boards (IC698RMX016CA-xx and IC698016CA-xx) must be returned for replacement. Problems Resolved in this Release (ED) A Subject Incorrect Bad Data or Sync loss error reported Description In earlier versions of this product, under rare conditions, Bad Data and Sync Loss errors were erroneously reported. This condition was seen at temperatures above 40 C (no fans) and large data transfers (64K). This problem has been corrected in version ED. Network Bandwidth The maximum bandwidth of the reflective memory network is 174Mbytes/s. The application must avoid a situation where the transmit FIFO becomes full. You can accomplish this by not having multiple nodes transmit a large amount of data at the same time. The RX FIFO Almost Full status (bit 09) of the LISR (Region 2, offset 10h) can be monitored to determine if the network is becoming saturated. For an example of network load balancing, refer to Optimizing Network Bandwidth in the PACSystems RX7i Memory Xchange Modules User s Manual, GFK-2300.

Control Memory Xchange Module 3 Sample Six-node Reflective Memory Network PCI WorkStation with VMIPCI-5565 reflective memory board User Features The front panel of the module has four LED indicators and an optical transceiver. Optical Transceiver The optical transceiver has two LC type fiber optic ports. The port labeled TX is the transmitter and the port labeled RX is the receiver. Memory Xchange modules are networked together using either simplex (single fiber) or duplex (dual fiber) multimode fiber optic cables. The specific cable construction depends on your operating environment. For details on cables, refer to the PACSystems RX7i Memory Xchange Modules User s Manual, GFK-2300. LEDs All front panel LED indicators are green. LED Label OK CONFIG OWN DATA SIGNAL DETECT Description ON indicates the module is functioning properly. When not used as a redundancy link, ON indicates the module is configured. When used as a redundancy link (RMX only), ON indicates the link is functioning properly. ON indicates the module has received its own data packet from the network at least once. ON indicates the receiver is detecting a fiber optic signal.

4 Control Memory Xchange Module Installation Make sure you have the items listed below before you begin. A PACSystems RX7i with release 2.00 or higher firmware A PACSystems RX7i rack with power supply. Programming software: Machine Edition Logic Developer PLC, version 4.5 or later (and a PC-compatible computer). Cables. For details, see Fiber Optic Cables and Connectors in the PACSystems RX7i Memory Xchange Modules User s Manual, GFK-2300. Note: RX7i systems that include one or more Memory Xchange modules must be installed in a metal enclosure with conduit or equivalent to meet radiated emission standards. For details, refer to the PACSystems RX7i Installation Manual, GFK-2223. Installing the Module in an RX7i Rack Warning Do not insert or remove modules with power applied. This could cause the to stop, damage the module, or result in personal injury. Memory Xchange modules must only be installed in the main (Rack 0) RX7i rack. RX7i supports a maximum of four Memory Xchange modules per main rack. 1. Make sure rack power is off. 2. Slide the module into the slot for which it was configured in the system. 3. Press the board firmly in place, but do not force the board. Tighten the screws on the top and bottom of the faceplate. 4. Connect the fiber optic cables to the TX and RX connectors. 5. Route the cable from TX to the RX connector of the next node in the ring. Connect the cable from that board s TX to the RX connector of the next node. Repeat this step until the last node in the ring routes its TX to the RX of the first node. 6. Turn on power to the RX7i rack.

Control Memory Xchange Module 5 Configuration The module initially powers up in an unconfigured state with its optical transmitter and receiver disabled. The module cannot operate on a network until the RX7i has delivered a hardware configuration to the module. Basic operating functions are configured using Machine Edition Logic Developer PLC. You can configure the following parameters in the hardware configuration: Node ID, Redundant Transfer Mode, Rogue Master, Network Memory Offset, and Interrupt enable. Additional functions beyond the basic read and write operations, including enabling interrupts, reading interrupt status, enabling parity, and reading parity errors, can be performed by user logic. For details on accessing these advanced functions, refer to the PACSystems RX7i Memory Xchange Modules User s Manual, GFK-2300. Operation Once the has been configured, a transfer of data over the network can be initiated by writing to the reflective memory region through the VMEbus. The Memory Xchange module forms the data into variable length packets sized from 4 to 64 bytes, which it transmits over the fiber-optic network to the receiver of the next node. Whenever a packet is received, the Memory Xchange module evaluates the packet. If the packet is valid and did not originate on this node, it is accepted. If, however, the data packet is invalid or if it originated at this node, it is discarded. The receiving node writes the data into the local reflective memory and simultaneously transmits the data to the next node on the network. From there, the process is repeated until the data returns to the originating node, where it is removed from the network. Related Publications PACSystems RX7i Reference Manual, GFK-2222 PACSystems RX7i Installation Manual, GFK-2223 PACSystems RX7i Memory Xchange Modules User s Manual, GFK-2300 Proficy Machine Edition Logic Developer-PLC Getting Started, GFK-1918 Specifications* Physical size PCB: 6.299 W x 9.187 H Packet size Dynamic, automatically controlled by Memory Xchange module User memory 16MB SDRAM Operating voltage +5VDC (from power supply) Current requirements 1.8A Connectors Fiber optic LC type, conforms to IEC 61754-20 Zirconium ceramic ferrule Insertion loss: 0.35 db (maximum) Return loss: -30dB Temperature Range: -20 C to +85 C * For environmental specifications and compliance to standards (for example, FCC or European Union Directives), refer to the PACSystems RX7i Installation Manual, GFK-2223.

6 Control Memory Xchange Module Ordering Information Description Control Memory Xchange Module for RX7i Redundancy Memory Xchange Module for RX7i Fiber Optic Cables Lithium Battery pack Rack Fan Assembly, 120VAC Rack Fan Assembly, 240VAC Rack Fan Assembly, 24VDC RX7i PLC, 85 to 264 VAC at 47 to 63 Hz Input, 100 watt output RX7i PLC, 85 to 264 VAC at 47 to 63 Hz Input, 350 watt output [Optional] RS-232 cable; also Station Manager cable for Ethernet interface IC698016 IC698RMX016 Catalog Number VMICBL-000-F5-0XX, where 0XX is used to distinguish different lengths IC698ACC701 IC697ACC721 IC697ACC724 IC697ACC744 IC698PSA100 IC698PSA350 IC200CBL001 The following information is for products bearing the UL marking for Hazardous Locations: WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES. WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C, & D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON- HAZARDOUS LOCATIONS ONLY.