universit y of northern colorado

Similar documents
impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

impact INSTRUCTIONS VS-LCD Series Flash lighting equipment and accessories

interfit S1 Battery-Powered TTL/HSS Flash

impact INSTRUCTIONS VC-500LR Monolight lighting equipment and accessories

Revo 120. User Manual

Cheetah Light LLC. (214) Instruction Manual

lighting your creativity BADGER UNLEASHED BATTERY-POWERED 250Ws TTL/HSS FLASH Instruction Manual

ALPHA MONOLIGHT USER MANUAL SDR-400

PHOS mini OPERATING INSTRUCTIONS

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Cheetah Light LLC. (214) Instruction Manual

To connect the AC adapter:

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

EPS Power Supply

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

The White Lightning Ultra Series (White Lightning Models Ultra 600, Ultra 1200, and Ultra 1800) Operating Instructions

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

OMM200 and OMM200T. Metallurgical Microscope

Pulse LED Instruction Guide

Robot Light V2. User Manual

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Model DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL

1 Channel Strobe Controller ORDERCODE 40226

ft Aspen Fir Item # Commercial ITEM Lights

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

PHOS 20/40 downlight OWNER'S MANUAL

LED W RGBA User Manual

User s manual. Easy Scan XT3 LED

PROFESSIONAL SHOW LIGHT

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

ALO Duo Roll DMX LED barrel scanner with dual light source

VC-500WL Monolight INSTRUCTIONS

Vacuum Tubes Power Supply Unit. for WA7 and WA7d Fireflies. Owner s Manual. Please review this manual before operating your WOO AUDIO product.

20W Tungsten-Halogen Light Source. Operation Manual

Digital Overhead Stirrer

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

Springtree Spatial Wash COB RGBW

Troubleshooting CHAPTER

User Guide Professional Entertainment Technology

Model HM-535 Power Supply Installation and Service Instructions

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Remote Control Electrical Roller Blinds

LED SPIDER MOVING HEAD LIGHT

Motorized Curtain Tracks Progress 50 Motor Set

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

VC-500WL3KN Digital Monolight INSTRUCTIONS

Springtree Spatial Wash COB WW

Richter Optica. Instructions for Model: HSX1 High School Microscope

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

Is the Product correctly plugged?

SP mm F/4-5.6 Di VC USD for Canon and Nikon (Model A005) SP mm F/4-5.6 Di USD for Sony (Model A005)

User Manual. Trinocular Stereo Microscope

USER MANUAL GEBRAUCHSANLEITUNG EN DE MANUEL D UTILISATION

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

NE400 - LED MOTION LIGHT WITH VIDEO CAMERA

SP mm F/2.8 Di VC USD (Model A009)

There are two basic applications for the Ikelite DS Sensor. Add an External Strobe. Camera WITHOUT flash connection

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

Plasma Panel Replacement Guide DU-42PX12X

SP 90mm F/2.8 Di VC USD 1:1 Macro (Model F004)

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Gateway Profile 4 service guide

LED Accu Penta 9x12W RGBWAU

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

SPECIAL PROJECTS 3800 Hwy 271 North Powderly, TX Phone: Fax: Aqua 20/20 OWNER S MANUAL

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Written By: Walter Galan

Eternal Lighting. Premier150 Spot. User Manual

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

Introduction REAR VIEW SAFETY

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

Blue Weapon Laser. User manual UK. Version 1.0

Serial No. OWNER S MANUAL. Installation & Operation

C-pan arm USERS INSTRUCTIONS

B&W RearView Camera Installation & Operation

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

DUAL LASER PACK & CONTROLLER USERS MANUAL

Breeze Film Shooting Equipment (P-W5P-BRZ) I N STR UC TI ON MANUAL

When you are ready to build your computer you will have the following materials to work with.

Installation Instructions

Thanks for shopping with Improvements! Rock Hill Pre-Light Command Christmas Tree- 7 Item #546329

AC LEISURE PRO SHORE COMMANDER

M215-Z Safety Information (M LL-IG-ZC)

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

28-300mm F/ XR Di VC LD Aspherical [IF] Macro (Model A020)

DT-900 Techstrobe Operation Manual

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Transcription:

universit y of northern colorado school of art & design photography studio flash instructions [speedotron-black line] The Speedotron Black Line equipment is reserved for studio use only PACKS 2403cx [2400ws] 2405cx LV [2400ws] HEADS 202VF (5) 1542 Spotlight MODIFIERS 11 Reflector (2) 7 Reflector (2) Snoot Grid Spot Set Speedrings (4) 20 Beauty Dish ACCESSORIES Power Cord for 2403cx Power Cord for 2405cx Cable for 202vf (5) SAFETY RULES No one is allowed to use the flash equipment without attending the Studio Flash Workshop and passing the Studio Flash Safety & Procedure Test Anyone allowing another person to use the flash equipment will lose their studio and equipment privilages for the rest of the semester Always turn off the power & immediately discharge the pack before removing any cables! Always pull out the power cords and cables by the ends, not the cord itself Never place your hand on the head sockets you will send over 10,000 volts through your body [and die] Always notify your instructor if the flash equipment is broken Use gloves to remove/adjust reflectors and other metal light modifiers Never allow lighting gels to come in contact with the modeling light/flash tube Only use a C-47 clamp to attach lighting gels to the flash head-never use tape Allow the flash head to cool off before moving it/putting on the travel cap Always put shot bag/weight on light stand prior to attaching the flash head Never let a power cord or flash cable wind around a light stand leg studio flash instructions [speedotron-black line]_20150515 1

INSTRUCTION MANUAL FOR SPEEDOTRON BLACK LINE EQUIPMENT TABLE OF CONTENTS Power Supply Instructions Read This First 2 General Maintenance and Care 7 Description of Controls 3 Trouble Shooting 8 Operating Instructions 4 Guide Numbers 9 Power Distribution Tables 5 Flash Duration 9 Light Units 6 Technical Specifications 10 Accessories 6 GENERAL INSTRUCTIONS Although Speedotron Black Line power supplies vary in power and features, they all operate under the same principles. The following instructions apply to the entire Black Line series. For maximum equipment life and for safe, dependable operation of power supplies, we advise you to follow these general rules. Information contained in this manual is applicable to New Speedotron Equipment at the time of writing. Some information may not be applicable to older Speedotron equipment. Before doing anything with the power supply make sure that the Model and Power switches are in the off position and the Reset buttons (circuit breakers) are fully depressed into their sockets. Connect light cable(s) to the Light Unit Outlet(s) on the power supply (with the 202VF and 206VF lights, connect the light unit cable to the light unit before connecting to power supply), selecting the appropriate outlets for the desired power level. (Refer to the diagrams on the side of the power supply.) To insert, align the light unit plug with the power supply outlet and apply even pressure while pushing. Make sure that all light unit cables are firmly seated and you hear or feel the quick release ring click into place or the lockring of 206 light units is fully threaded. Make sure cables are out of pathways or are taped to the floor to prevent accidentally disconnecting cables from power supply. studio flash instructions [speedotron-black line]_20150515 NEVER connect or disconnect a light unit while the power supply is turned on. NEVER insert or remove flash tubes while the light unit is connected to the power supply. Flash tubes must be inserted into the sockets all the way. A slight rock- 2 ing motion may be necessary when installing the larger flash tubes. New flash tubes and sockets fit very tightly. Be sure flash tubes are fully seated into light unit sockets. (Read instructions in the Light Units section of this manual for more information on light unit assembly and operation.) Always make sure your Model and Power switches are off when disconnecting or connecting light units. Speedotron power supplies are equipped with arc-protected outlets. However, as with any electrical equipment, arc-over (an electrical discharge between two physically disconnected electrical terminals) is a possibility. When light cables, flash tubes or power cords are improperly seated, arc-over may occur. Also, if your light unit or power supply malfunctions, or the power cord or the internal wiring in the studio is improperly terminated or defective, there is a chance of arcover. Severe power supply damage and operator injury may result if arc-over occurs. Always handle lamps and flash tubes with care. Because they can break if put under stress, handle cautiously. Don t touch glass surfaces with your bare hands. When removing or replacing lamps and tubes, always disconnect light units from power supply. Allow lamps to cool before handling or installing protective tube covers. All Speedotron Black Line flash tubes are designed to accept a minimum of 2400Ws. Light units come with a 5/8 light stand mount. The umbrella bracket is drilled to accept 3/8 diameter umbrella shafts - 5/16 on 202 and 206 (must be used with 7 reflector). The umbrella bracket may be moved to a position closer to the light unit body to accept special umbrellas and accessories. When using this alternate position

the reflector will have to be custom drilled to accept the umbrella shaft. Install the desired reflector unto the light unit. Align the round notches on the reflector with the nylon buttons on the light unit, then twist firmly clockwise, (viewed from front and insuring that reflector assembly is bottomed on mounting socket) approximately 1/4 of a turn. This should securely mount the reflector into the light unit housing. Plug sync adapter into Sync socket and connect other end to a wireless remote (Pocket Wizard). These sync extensions have a 1/4 international (phone jack) plug. Insure that protective flashtube covers are removed from light units before turning on model lamps or flashing. A slave tripper may be installed in the Sync socket to fire the power supply. Trigger voltage - 2403CX LV and 2405 CX LV power supplies have Trigger Circuits of 6 volts or less and should be safe for operation with all digital cameras. See your camera s instruction manual for specific voltage requirements. Connect AC power cord into Power Input on power supply. Always use a three-wire ground power cord and a properly grounded wall outlet with all Speedotron power supplies. Failure to do so may cause the power supply to intermittently misfire. Do not use a three prong-to-two prong ground eliminator adapter. Once the light units are properly assembled and installed, the power cord is installed and the sync extension is connected, turn the Power switch on. DO NOT immediately fire the unit on the first use or when the unit has been idle for periods over 3 weeks. Allow several minutes for the power supply s capacitors to form. Once this procedure has been followed at these times, subsequent use of the power supply requires no waiting period. Ready/Push to Flash button may be depressed to verify proper system operation. When Power is on, be sure Ready/Push to Flash indicator is illuminated before switching Power, Combine/Isolate, or Fast/Slow controls. DO NOT move these switches while the unit is recycling. Turn on power supply, wait for Ready light, then press Push to Flash button to verify proper operation. At this time, the fan should be operating. The model lamp is controlled by the Model switch at the power supply. Some light units also have a Model switch on the top or side of the light unit. For maximum performance and tube life, the model lamp should be used only when necessary and turned off after initial set-up or focusing is done. Although the forced air cooling is more than ample for normal usage, turning off the model lamp will eliminate heat and enable the light to run cooler, extending the life of all components. After extended use, inspect flash tubes for cracks and any unusual darkening (arc-over) around the plugs. This is particularly important for multi-tube flash lights. If cracks or darkening are noted the flash tube is, most likely, near the end of its duty cycle. Cracked tubes will probably misfire. The normal life expectancy is 100,000 flashes for the majority of Speedotron Black Line flash tubes. Be sure replacement flash tubes are designed for the watt-second output requirements of Speedotron light units. Never subject a flash tube to more watt-seconds than it is designed to handle. Applying too much power severely shortens the life of flash tubes, may cause fine cracks to develop in the tube that may cause tube failure or, in the most extreme case, may cause a tube to shatter. For this reason, we suggest you always use Speedotron flash tubes and model lamps to insure safe and dependable operation. Each Black Line power supply s unique features are fully explained in the next section of this manual. Never attempt to make repairs to your Speedotron equipment. All electronic flash systems operate on high voltage and power. It is very dangerous to open a power supply. To summarize, set-up should go as follows: Make sure power supply is off (both Model and Power switches in the off position) and unplugged. Connect light units to power supply. Inspect all connections, flash tubes and modeling lights. Set desired ratio. Connect sync cable to power supply and camera Connect power supply to AC. Turn on power supply and wait for it to reach full charge. Test to see that all light units are flashing and slave triggers (if any) are functioning. studio flash instructions [speedotron-black line]_20150515 3

2403 CX LV DESCRIPTION OF CONTROLS 1) Power turns power supply on and off (flashes light units when turning off) 2) Model Light turns model lamps on and off. 3) 800Ws Isolate/Combine when in isolate, this switch isolates the 400Ws channel from the 1200Ws channel and provides two Light Unit Outlets per channel. When in combine, will provide 1600Ws among 4 Light Unit Outlets. 4) 400Ws Isolate/Combine when in isolate, this switch isolates the 800Ws channel from the 1200Ws channel and provides two Light Unit Outlets per channel. When in combine, will provide 2400Ws among 4 Light Unit Outlets. (With both 800Ws and the 400Ws switches in combine, 2400Wx is available through any of the six Light Unit Outlets, divided equally. See diagrams on the side of the power supply and page 15 for detailed examples of the ratio system). 5) Variable Power Control simultaneously controls power of all 3 channels, with ten positions down to -3 stops (1/8th pwer). Power ratios among the light units are unaffected since there is a proportional change in all power levels. 6) Recycle Rate controls recycle rate. 7) Charge/Ready/Push to Flash red Charge light is illuminated whenever the power supply is charging up or down to the selected level. Green Ready light is lit whenever the 2403 CX LV is fully charged to the selected power level. An audible beep will sound when the green Ready light comes on. Push to Flash button is for manual triggering of flash for testing or open flash application. 8) Remote for use with optional Remote Variable Power Control to allow exposure bracketing from the camera position. The Variable Power Control must be in the full position for the power levels to be correctly indicated by the remote control. [We don t have one] 9) Sync socket to connect camera or slave to power supply. 10) Power Input socket for AC power cord. 11) Light Unit Outlets (6) sockets for connecting from one to six light units to power supply. Power and Model Resets push to reset circuit breaker. Circuit breaker disables power supply in case of malfunction. 4 studio flash instructions [speedotron-black line]_20150515

OPERATING INSTRUCTIONS 2403CX LV Set Isolate/Combine switches and Variable Power Control as desired.see the side of the power supply for various ratio combinations. With the Variable Power Control in the Full position, power is determined by the choice of outlets and position of ratio switches. The Variable Power Control simultaneously changes the power level of all three channels. Rotating the Variable Power Control immediately adjusts the power level of the 2403CX LV. The power supply does not need to be discharged between settings. Turn Power Switch on. The red Charge indicator will illuminate. After a few seconds, the green Ready indicator will illuminate and an audible beep will sound. (The beep will not be produced when a very small power change is made. Changing the power level by a third f-stop or so is done very rapidly with the 2403CX LV; the Ready light will usually remain on) The power supply is now charged to the selected level, and ready to fire. DO NOT immediately fire the unit on the first use or when the unit has been idle for periods over 3 weeks. Allow several minutes for the power supply s capacitors to form. Push to Flash button may be depressed to verify proper system operation. When Power is on, be sure Ready indicator is illuminated before switching Power or Fast/Slow. Do not move these switches while the unit is recycling. When disassembling the system, turn Power switch to the off position. The 2403CX LV power supply will automatically discharge its storage capacitors. DO NOT PUSH the Push to Flash switch before turning power supply off. This may damage power supply. Power supplies may flash their light units when turned off. This is normal. Unplug power cord from outlet, then disconnect light units from power supply. Power Ratios Black Line equipment is capable of symmetrical (all light units receiving the same amount of light) or asymmetrical (ratioed) power distribution. Controlling distribution is as easy as flipping a switch. Each power supply is divided into three channels with different levels of power. These channels may may be joined for even (symmetrical) output to all outlets or separated for unequal (asymmetrical) output to a set of outlets in one or more channels. When we refer to ratioing, we are describing the levels of power output from the power supply to the light units only. These power output ratios do not mean that the light falling on the subject will be at that same ratio. This will only occur if the light units are the same and have the same flash tube, reflector, cable length, light control accessories, are at the same distance to the subject, and there is no overlap of lighting on the subject, etc. Power output ratios are only offered as a guide to help you determine your lighting arrangements. studio flash instructions [speedotron-black line]_20150515 5

2405 CX LV DESCRIPTION OF CONTROLS 1) Power turns power supply on and off (flashes light units when turning off) 2) Model turns model lamps on and off. 3) Fast/Slow controls recycle rate. 4) Combine/Isolate controls 3-channel power distribution. Combine connects channels as indicated (A+B, B+C) with symmetrical distribution; Isolate separates channels as indicated (A B, B C). 5) Variable Power Control simultaneously controls power of all 3 channels, in 1/4 stop increments, down to -2 stops (1/4 power). 6) Ready/Push to Flash illuminates when power supply reaches 100% recycle. Pushing the button manually triggers the flash for testing or open flash applications. 7) Sync socket to connect camera or slave to power supply. 8) Reset push to reset circuit breakers. Circuit breaker disables power supply in case of malfunction. 9) Variable Model Lamp Control (3) controls output of model lamps, down to -3 stops (1/8 power), independently for each channel. 10) Light Unit Outlets (4) sockets for connecting from one to four light units to power supply. 11) Power Input socket for AC power cord. 6 studio flash instructions [speedotron-black line]_20150515

OPERATING INSTRUCTIONS 2405CX LV Set Combine/Isolate switches for desired ratio of power to light unit(s). See the chart on the side of the power supply and the next page for ratio combinations that are possible with up to four light units. Set Fast/Slow switch. Normally, you will operate the unit in fast recycle mode. However, if you do not have adequate power in your studio, this may cause circuit breakers in your studio to blow. In this case, use slow recycle mode. Connect power supply to AC outlet. Turn Power switch on. Ready/Push to Flash indicator will illuminate, indicating 100% recycle. The unit is now fully charged and ready to fire. DO NOT immediately fire the unit on the first use or when the unit has been idle for periods over 3 weeks. Allow several minutes for the power supply s capacitors to form. When the power supply has been used recently you may fire the unit immediately. Ready/Push to Flash button may be depressed to verify proper system operation. The Ready/Push to Flash indicator light will periodically flicker. This is normal and indicates the operation of the voltage regulator. When Power is on, be sure Ready/Push to Flash indicator is illuminated before switching Power, Combine/ Isolate, or Fast/Slow controls. DO NOT move these switches while the unit is recycling. The Variable Power Control simultaneously changes power of all 3 channels. When decreasing power (rotating knob from Full to -1 stop, for example) power to the light unit(s) will not be reduced until the 2405CX LV has been fired. Press the Push to Flash button to discharge unit. When increasing power (rotating knob from -1 stop to Full, for example) it is immediately increased to the light units. Rotating the Variable Power Control does not change the output of the model lamps. Their output is controlled by the Variable Model Lamps Controls, one control for each power channel. Rotating the knobs immediately adjusts the output of the model lamps. This way, model lamp output can be matched to the light units, and lighting ratios are easily visualized. When disassembling the system, turn Power switch to the off position. This flashes all light units connected to the Model 2405CX LV. DO NOT push the Push to Flash switch before turning power supply off. This will damage power supply. Unplug power cord from outlet, then disconnect light units from power supply. Power Ratios Black Line equipment is capable of symmetrical (all light units receiving the same amount of light) or asymmetrical (ratioed) power distribution. Controlling distribution is as easy as flipping a switch. Each power supply is divided into three channels with different levels of power. These channels may may be joined for even (symmetrical) output to all outlets or separated for unequal (asymmetrical) output to a set of outlets in one or more channels. When we refer to ratioing, we are describing the levels of power output from the power supply to the light units only. These power output ratios do not mean that the light falling on the subject will be at that same ratio. This will only occur if the light units are the same and have the same flash tube, reflector, cable length, light control accessories, are at the same distance to the subject, and there is no overlap of lighting on the subject, etc. Power output ratios are only offered as a guide to help you determine your lighting arrangements. studio flash instructions [speedotron-black line]_20150515 7

LIGHT UNITS 202VF This extremely portable, modular, heavy duty light unit has noiseless fan cooling. Reflectors mount to the red focusing collar, offering a wide range of coverage. Assembly of the 202VF is simple. Attach the pan-tilt bracket to the right side of the light unit with the thumb screw. Turning the pan-tilt bracket handle counter-clockwise allows one-handed positioning of the 202VF. The light unit cable must be attached to the 202VF before connecting to a power supply. Align the flat surface of the molded strain relief plug with the outlet at the back of the light unit. Push the cable straight in, and give the locking ring a 1/3 clockwise turn, until it clicks. The red focusing collar is normally mounted with the nylon button forward (although reverse mounting may be better for customized soft boxes or other special-use applications). With a reflector mounted and the focusing collar in the fully forward position, narrow angles and high guide numbers are achieved. When rotated fully back (about 2 full turns), the widest angles and the lowest guide numbers are achieved. The best general results with Speedotron universal reflectors is at the midpoint, about 1 turn back. For soft box use, the fully back position will generally be best. Umbrellas are mounted through the hole in the 7 umbrella reflector for 202VF, limiting the movement of the focusing collar to four positions. The black switch on the side of the light unit may be used to turn off the model lamp. For other operating instructions, follow the General Information section of this manual. 206VF This heavy duty light unit operates directly with the 4803 power supply or on all standard outlet power supplies using the #14202 adapter cable. Its single, fan-cooled flash tube can handle up to 5000Ws maximum. It is equipped with a larger plug for use on the 4800Ws outlets on the 4803. Standard with 11.5 universal grid reflector. The red switch on the side of the light unit may be used to turn off the model lamp. See the General Information and 4803 power supply sections of this manual for additional operating instructions. STRAND OPTIQUE 1542 This is a special purpose spot light which creates a very hard-edged light that can be focused to cover 8 to 42. There is a gate at the top of the unit that accepts M sized gobos to create special shapes and patterns. Due to the high heat created by the modeling lamp, only approved metal gobos may be used. The 1542 has four beam shaping shutters to modify the shape of the outside edge of the light. Lenses may be focused by means of twist lockable external knobs on the side of the light unit. The light may be focused to the gobo or the shutters for optimum cut off. 8 studio flash instructions [speedotron-black line]_20150515

GENERAL MAINTENANCE AND CARE All Speedotron Black Line equipment is ruggedly built. Nevertheless, it should be treated with the same care given to other pieces of quality photographic equipment. To protect the user, all Speedotron equipment is designed to be safe when used in accordance with instructions. To assure the maximum in safe, dependable service, the following guidelines should be carefully observed. Avoid kinking or pulling cables. Disconnect cables by pulling on the quick release only, except for the 206 light unit which has a threaded ring. Never pull plugs out by the cable. Light cables as well as sync cords and AC power cords should be occasionally checked for wear, cracks, separation between cable and plug, and for indications of arcover. Do not wrap the light unit cables around the light units. Coiling cables tightly stresses the internal wires and may lead to premature cable failure. If possible, keep the coil diameter at least 10 inches. If a cable becomes frayed, the insulation damaged, or the connectors bent or broken, have them repaired immediately. Keep all connectors, plugs and sockets free of dust, moisture and corrosion. Do not connect or disconnect light units or insert or remove flash tubes while the power supply is on. When using your equipment, be sure all cable, sync, power and flash tube connections are completely and properly installed. Do not attempt to make repairs to your Speedotron equipment yourself. It is very dangerous, and will void your warranty. Consult your dealer regarding authorized service in your area, or return the equipment to Speedotron. When you are not using your equipment, it is recommended that you store it in a dry place. Equipment should be charged up and flashed a few times at least once a month. This will keep your equipment in top working condition for many years. With your light unit disconnected, occasionally remove the reflector and clean the interior surface with a light solvent or soap and water. Carefully remove the flash tube, and clean the glass cover. Only in this way will you conserve a consistent color temperature and light output. Dirt and dust deposits on the tube and reflector act like a filter to alter color. To extend the life of the model lamp, it should be turned off after setup and focusing. studio flash instructions [speedotron-black line]_20150515 9

TROUBLESHOOTING System will not work at all; no flash. Check that sync cable, AC power cord and light unit cables are firmly and properly attached. Check that the flash tube is firmly seated. Check that Power switch is on. Occasional failure of all light units to flash. Check sync cable and light unit cable connections. Make sure that the Ready indicator is illuminated before attempting to fire unit. Occasional failure of one light unit only. Check light unit cable connection. Inspect the cable. Check flash tube. Make sure that the Ready indicator is illuminated before attempting to fire unit. Reduced light output. Check to see if Ratio or Variable Power Control switch is in right position. Check flash tube; check power supply by comparing to similar pack with same light units if possible. Flash tube glows after a flash (afterglow) and will not flash again until glow is gone. If confined to one light unit, check flash tube by substitution. If it continues or all lights afterglow, power supply is at fault. If this is the case, turn power supply off immediately! Power supply needs repair. Ratio or Variable Power Control switch has no effect on recycle time or light output. Power supply needs repair. Circuit breaker on power supply pops. Check that all cables on power supply and light units are properly connected. Also check for afterglow. If a circuit breaker blows, it is an indication that something is wrong. Normal operation will not blow circuit breakers. Circuit breaker or fuse in studio blows. Use slow setting on Recycle rate switch. Model lamp fails to light on one light unit. Check that the model lamp switch on that light unit is in the ON position. When checking power supplies, light units and cables, be sure that Power is off. Look for blackened, discolored or burned pins and sockets. If a Light Unit Outlet on the power supply is burned, blackened or discolored, it must be replaced before it is used. It could damage light units that are connected to it. Check that cables are not loose or frayed. 10 studio flash instructions [speedotron-black line]_20150515

FLASH DURATION LIGHT MODIFIERS FOR LIGHT UNITS WITH REMOVABLE REFLECTORS 14258 aluminum background reflector 14209 7 snoot 14222 7 105 umbrella reflector 14225 11.5 50 grid reflector 14619 grid set for 7 reflector [10, 20, 30, 40 ] NON-SPEEDOTRON LIGHT MODIFIERS speedring for softboxes medium softbox large softbox Ex large softbox 20 beauty dish collapsible reflector/diffusion disks 3x3 diffuser white umbrella silver umbrella parabolic umbrella studio flash instructions [speedotron-black line]_20150515 11