DEEP SEA ELECTRONICS PLC

Similar documents
DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

DEEP SEA ELECTRONICS PLC

DSE2548 LED expansion module INTRODUCTION

DEEP SEA ELECTRONICS PLC

DSE2510/20 REMOTE DISPLAY MODULES. DSEGenset DSE2510/20 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS FEATURES

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DSE334 ATS Controller Operators Manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSE890 / DSE891 GATEWAY INSTALLATION INSTRUCTIONS

DSEEXTRA. DSE860 RS232 Ethernet Adaptor DSE865 RS485 Ethernet Adaptor Document Number Author : Anthony Manton

DEEP SEA ELECTRONICS PLC DSE8005 SCADA Suite PC Software Manual

DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

DSEPOWER. DSE7520 MK1 Mains Control Module. Document Number Author : Anthony Manton

DEEP SEA ELECTRONICS PLC

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

DSEULTRA DSE3110 Series Control Module

Installation & Operation and Maintenance

DEEP SEA ELECTRONICS PLC DSEWebNet PC Internet Browser Software Manual

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

DSEPOWER. DSE8721 Colour Remote Display Module. Document number Author : Anthony Manton

DSEPOWER DSE7510 Control Module Document Number

DEEP SEA ELECTRONICS PLC

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

MOXA TCC-120/120I User s Guide

LED Driver. Xitanium DALI 40W A 54V DALI XI040C110V054YPT2

DSEULTRA DSE6100 Series Control Module Document Number

DALI Gateway 5502DAL. Installation Instructions

Quick Start M!DGE / MG102 Wireless Router 6/13/2017

NPCI-PMC Technical Reference Manual

XEC supercap (v. 1.0)

Operating instructions. Switching amplifier DN0210 DN / / 2015

NI PXI-1042 Series Power Supply Shuttle

Resistance measuring module

Instruction Manual. EXDC Turbomolecular Pump Drive Modules. Item Number

DEEP SEA ELECTRONICS PLC

Power Enclosure Components

Quick Start M!DGE / MG102 Wireless Router 11/16/2011

LCI User Manual mantracourt.com

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

LCI Load Cell Junction Box with Fault Monitor

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

FLEX Ex Spring Clamp Terminal Base

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Installation instructions Inclination sensor EC2019 EC / / 2013

PRODUCT SPECIFICATION. PC Board Relays. Series.

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

USER MANUAL. WBI412F41 AC current transducer

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

USB-2001-TC. USB-based Thermocouple Input. User's Guide

C-Bus Ceiling Sweep Fan Controller L5501RFCP. Installation Instructions

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

itemp TMT180 Technical information

EMS CX 3 - Signalling Auxiliary Contact (CA + SD)

iothinx 4500 Series (45MR) Modules

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

Installation guide H A. HSI-C hard-wired system interface configurable

INJ-24A Series Quick Installation Guide

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Ultra Slim Relays 24

DEEP SEA ELECTRONICS PLC

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

SCC-AO10 Isolated Analog Output Module

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Gateway BACnet IP/MS-TP slave KNX TP Code: EK-BJ1-TP-IP / EK-BJ1-TP-MSTP

Wall-/Pipe Mounted Universal Process Indicator

Signal Doublers. VariTrans A 20300

DYNAMIC ENGINEERING. 150 DuBois St. #3, Santa Cruz Ca Fax Est

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

MINI MCR-SL-PT100-UI-200

D Issue A. Instruction Manual. Active Strain Gauge

Island bus expansion module

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

iologik 4000 Series (M) Modules

User Guide. Beckhoff CTNet I/O. Remote I/O for CTNet. Part Number: Issue: 3.

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

USER MANUAL. WBI414F21 AC current transducer

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Instruction Manual. ICENI/TB-02 Terminal Block Module (Type 2) Pub_ Issue 1

MasterBus USB interface

Transcription:

DEEP SEA ELECTRONICS PLC DSE2133 DSEnet RTD / Thermocouple Input Expansion Module Operator Manual Document number 057-140 Author : Anthony Manton DSE2131 DSEnet RTD / Thermocouple Input Expansion Module Operator Manual ISSUE 1.1

DSE2131 DSEnet RTD / Thermocouple Input Expansion Module Operator Manual Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales Fax: +44 (0) 1723 893303 E-mail : sales@deepseaplc.com Website : www.deepseaplc.com DSE2133 DSEnet RTD / Thermocouple Input Expansion Module Deep Sea Electronics Plc All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents Act 1988. Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to Deep Sea Electronics Plc at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. Deep Sea Electronics Plc reserves the right to change the contents of this document without prior notice. Amendments since last publication Amd. No. Comments 1 First release 1.1 Corrected supported RTD table. Typeface : The typeface used in this document is Arial. Care should be taken not to mistake the upper case letter I with the numeral 1. The numeral 1 has a top serif to avoid this confusion. 2

DSE2131 DSEnet RTD / Thermocouple Input Expansion Module Operator Manual Table of contents 1 BIBLIOGRAPHY... 4 2 INTRODUCTION... 4 3 SPECIFICATIONS... 5 3.1 PART NUMBERING... 5 3.1 POWER SUPPLY... 5 3.2 TERMINAL SPECIFICATION... 5 3.3 INPUTS... 6 3.3.1 RTD INPUTS... 6 3.3.2 THERMOCOUPLE INPUTS... 6 3.4 DSENET... 6 3.5 DIMENSIONS... 7 3.6 APPLICABLE STANDARDS... 8 4 INSTALLATION... 9 4.1 USER CONNECTIONS... 9 4.1.1 CONNECTOR A... 9 4.1.2 CONNECTOR B... 9 4.2 SCHEMATIC INTERCONNECTION DIAGRAM... 10 4.3 TYPICAL WIRING DIAGRAM... 10 5 CONTROLS AND INDICATIONS... 11 5.1 LED INDICATIONS... 11 5.2 ID SWITCH... 11 6 FAULT DIAGNOSIS... 12 7 MAINTENANCE, SPARES, REPAIR AND SERVICING... 12 8 WARRANTY... 12 9 DISPOSAL... 12 9.1 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT)... 12 9.2 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES... 12 3

Introduction 1 BIBLIOGRAPHY This document refers to and is reffered to by the following DSE publications which can be obtained from the DSE website www.deepseaplc.com DSE PART DESCRIPTION 057-115 8610 operator manual 057-119 8600 series configuration software manual 2 INTRODUCTION This document details the installation requirements of the DSE2133 RTD / Thermocouple input expansion module part of the DSENet range of ancilliary devices. The manual forms part of the product and should be kept for the entire life of the product. If the product is passed or supplied to another party, ensure that this document is passed to them for reference purposes. This is not a controlled document. You will not be automatically informed of updates. Any future updates of this document will be included to the DSE website at www.deepseaplc.com DSE2133 input expansion module is used in conjunction with supported DSE controllers to provide additional input functionality (8 RTD / Thermocouple inputs ). The inputs are configured in the host controller, the DSE2133 module is not itself configured apart from the ID switch. For further details on configuring the host controller you are referred to the relevant configuration software manual (refer to the section entitled Bibliography elsewhere in this document). 4

Specifications 3 SPECIFICATIONS 3.1 PART NUMBERING 2133-001 - 00 Product type DSE 2133 RTD / Thermocouple input expansion module 2133 Variant Standard product Hardware revision 00 Revision 1 001 At the time of this document production, there are no variants of this product and there have been no revisions of the module hardware. 3.1 POWER SUPPLY Minimum supply voltage 8V continuous, 4V for up to 5 minutes. Cranking dropouts Able to survive 0V for 50mS providing the supply was at least 10V before the dropout and recovers to 5 volts afterwards. Maximum supply voltage 35V continuous (protection to 60V) Maximum operating current 56mA at 12V, 20mA at 24V Conditions: All inputs configured as 3 wire PT100 Minimum operating current 50mA at 12V, 18mA at 24V Conditions: All inputs configured as thermocouple 3.2 TERMINAL SPECIFICATION Connection type Screw terminal, rising clamp, no internal spring Min cable size 0.5mm² (AWG 20) Max cable size 2.5mm² (AWG 14) 5

Specifications 3.3 INPUTS 3.3.1 RTD INPUTS Min Temp Max Temp R @ Min Temp R @ Max Temp Type ( C) ( C) (Ω) (Ω) PT100-200 +850 15 400 3.3.2 THERMOCOUPLE INPUTS Thermocouples Type Min Temp Max Temp V @ Min Temp V @ Max Temp ( C) ( C) (mv) (mv) J type -40 +750-2 +43 K type -200 +1350-6 +55 3.4 DSENET DSEnet is the interconnection cable between the host controller and the expansion module(s) and must not be connect to any device other than DSE equipment designed for connection to the DSEnet. Cable type Two core screened twisted pair Cable characteristic impedance 120Ω Recommended cable Belden 9841 Belden 9271 Maximum cable length 1000m (1km) when using Belden 9841 or direct equivalent. 500m (0.5km) when using Belden 9271 or direct equivalent. DSEnet topology Bus with no stubs (spurs) DSEnet termination 120Ω. Fitted internally to host controller. Must be fitted externally to the last expansion module by the customer. Maximum expansion modules Refer to host controller documentation NOTE : As a termination resistor is internally fitted to the host controller, the host controller must be the first unit on the DSEnet. A termination resistor MUST be fitted to the last unit on the DSEnet. For connection details, you are referred to the section entitled typical wiring diagram elsewhere in this document. 6

Specifications 3.5 DIMENSIONS Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres 164.6mm x 76.4mm x 48.9mm (6.48 x 3.01 x 1.93 ) 150g (0.6lb) DIN rail or chassis mounting EN 50022 35mm type only M4 clearance 152.37mm x 64.50mm (6.00 x 2.54 ) Dimensions in mm 7

Specifications 3.6 APPLICABLE STANDARDS BS 4884-1:1992 BS 4884-2:1993 BS 4884-3:1993 BS EN 60068-2-1 (Minimum temperature) BS EN 60068-2-2 (Maximum temperature) BS EN 60950 BS EN 61000-6-2 BS EN 61000-6-4 BS EN 60529 (Degrees of protection provided by enclosures) UL508 NEMA rating This document conforms to BS4884-1 1992 Specification for presentation of essential information. This document conforms to BS4884-2 1993 Guide to content This document conforms to BS4884-3 1993 Guide to presentation -30 C (-22 F) +70 C (158 F) Safety of information technology equipment, including electrical business equipment EMC Generic Immunity Standard (Industrial) EMC Generic Emission Standard (Industrial) IP21 enclosure type 1 (indoor use only) In line with our policy of continual development, Deep Sea Electronics, reserve the right to change specification without notice. 8

Installation 4 INSTALLATION The DSE2133 is designed to mounted within a control panel, either on the panel DIN rail utilising the integral mounts, or chassis mounted, utilising the mounting holes. For dimension and mounting details, see the section entitled Specification, Dimensions elsewhere in this document. 4.1 USER CONNECTIONS 4.1.1 CONNECTOR A Terminal Function Recommended size Notes 1 DC supply positive 1.0mm² (AWG18) 2 DC supply negative 1.0mm² (AWG18) 3 Screen DSEnet only 4 A 0.5mm² (AWG20) DSEnet only 5 B 0.5mm² (AWG20) DSEnet only 4.1.2 CONNECTOR B See typical wiring diagram for connection options. Terminal Function Recommended size 6 Channel A + 0.5mm² (AWG20) 7 Channel A - 0.5mm² (AWG20) 8 Channel B + 0.5mm² (AWG20) 9 Channel B - 0.5mm² (AWG20) 10 RTD 3 rd wire: Channel A & B 0.5mm² (AWG20) 11 Channel C + 0.5mm² (AWG20) 12 Channel C - 0.5mm² (AWG20) 13 Channel D + 0.5mm² (AWG20) 14 Channel D - 0.5mm² (AWG20) 15 RTD 3 rd wire: Channel C & D 0.5mm² (AWG20) 16 Channel E + 0.5mm² (AWG20) 17 Channel E - 0.5mm² (AWG20) 18 Channel F + 0.5mm² (AWG20) 19 Channel F - 0.5mm² (AWG20) 20 RTD 3 rd wire: Channel E & F 0.5mm² (AWG20) 21 Channel G + 0.5mm² (AWG20) 22 Channel G - 0.5mm² (AWG20) 23 Channel H + 0.5mm² (AWG20) 24 Channel H - 0.5mm² (AWG20) 25 RTD 3 rd wire: Channel G & H 0.5mm² (AWG20) 9

Installation 4.2 SCHEMATIC INTERCONNECTION DIAGRAM 4.3 TYPICAL WIRING DIAGRAM NOTE : Configuration of the inputs is performed in the host controller. 10

Controls and Indications 5 CONTROLS AND INDICATIONS Address Switch Power on / Link lost LED 5.1 LED INDICATIONS Function Colour Action Power on / Link lost RED Steady when DC supply is connected and data is being received from the host controller. Flashing when the DC supply is connected and the data connection to the host controller is not operating. 5.2 ID SWITCH The rotary ID switch is used to select the Identification of the DSE2133 expansion module as the host controller is capable of giving instructions to a number of DSE2133 expansion modules at the same time. Consult the relevant module s operating instructions for further details on number of supported expansion units (refer to the section entitled Bibliography elsewhere in this document). The enclosure cover must be unclipped and removed to gain access to the switch. The switch should be operated using a small screwdriver and set to match the required ID. NOTE : The ID must be set to be a unique number, different from the ID of any other DSE2133 input expansion module connected on the DSEnet. The ID of the DSE2133 will not interfere with the ID of any other type of expansion module. For instance it s OK to have a DSE2133 with ID1 and a 2157 with ID1. As the two modules are different type 11

Appendix 6 FAULT DIAGNOSIS Nature of problem Inputs don t activate on the host controller Power LED indication does not illuminate Power LED flashes Suggestion Ensure the host controller is correctly configured to accept the module. Check polarity and size of the connected DC supply are within the specifications. This means the the communications link to the host controller has been lost. Check the connection of the DSEnet paying particular attention to the cable type being used and the positioning of the termination resistors. 7 MAINTENANCE, SPARES, REPAIR AND SERVICING The module is designed to be Fit and Forget. As such, there are no user serviceable parts. In the case of malfunction you should contact your original equipment supplier (OEM). 8 WARRANTY DSE provides limited warranty to the equipment purchaser at the point of sale. For full details of any applicable warranty, you are referred to your original equipment supplier (OEM). 9 DISPOSAL 9.1 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT) Directive 2002/96/EC If you use electrical and electronic equipment you must store, collect, treat, recycle and dispose of WEEE separately from your other waste. 9.2 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES Directive 2002/95/EC:2006 To remove specified hazardous substances (Lead, Mercury, Hexavalent Chromium, Cadmium, PBB & PBDE s) Exemption Note: Category 9. (Monitoring & Control Instruments) as defined in Annex 1B of the WEEE directive will be exempt from the RoHS legislation. This was confirmed in the August 2005 UK s Department of Trade and Industry RoHS REGULATIONS Guide (Para 11). Despite this exemption DSE has been carefully removing all non RoHS compliant components from our supply chain and products. When this is completed a Lead Free & RoHS compatible manufacturing process will be phased into DSE production. This is a process that is almost complete and is being phased through different product groups. 12