Power Prowler. Quick Start Guide. 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables 600V CAT III. For Live Energized Cables

Similar documents
Power Prowler USER MANUAL PLR In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables.

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

USER'S MANUAL DCL-650

Net Prowler TM. Identify, Monitor & Test LAN Issues Quick Start Guide TNP700 TNP800 TNP850K1

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

OPERATING INSTRUCTION

AC/DC TRUE RMS CLAMP METER ACM-2036

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Digital Clamp Meter User Manual

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Mini Digital Multimeter

User Guide True RMS Multimeter Extech EX205T

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

Model A Mini AC/DC Clamp Meter. User's Guide

Autoranging True RMS Multimeter User Manual

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Mini Digital Multimeter

Model R5010. TRMS Digital Multimeter. Instruction Manual

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Net Prowler TM. User Manual. Identify, Monitor & Test LAN Issues TNP700

Net Prowler TM Identify, Monitor & Test LAN Issues

2 in 1 LAN Tester and Multimeter Model:

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

USER MANUAL. True RMS Multimeter. Extech EX430A

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. Digital Multimeter. Model MN42

Mini Digital Multimeter Model MN15. User's Guide

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

Autoranging Mini Multimeter

AutoRanging Digital MultiMeter

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Industrial Multimeter Extech EX510

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

MTP INSTRUCTION MANUAL

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

General Warranty. For more details, please refer to the user manual, it can be downloaded at

Autoranging Multimeter Extech EX503

Digital Clamp-on Meter Instruction Manual

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

7032 Digital-Analog Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Wa r n i n g-wa r n i n g-wa r n i n g

General Warranty. For more details, please refer to the user manual, it can be downloaded at

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

Digital Clamp-on Meter Instruction Manual

True RMS Multimeter with IR Thermometer

110.4 Use of Equipment.

Digital Clamp-on Meter Instruction Manual

True RMS Industrial Multimeter Extech EX520

Model 7705 Control Module

True RMS Industrial Multimeter Extech EX530

Mini Digital Multimeter

Bluetooth/USB Data Logger USER S MANUAL. Hantek 365A/B/C/D/E/F V

POCKET MULTIMETER Model No: MM18

Transient Fault Location for Energized Dedicated Circuit Breakers. TFT100 User Manual. Toll Free:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

DC / AC True RMS Watt Clamp DMM

True RMS Multimeter with IR Thermometer

Model 2657A-LIM-3 LO Interconnect Module

User s Guide. 600A AC Clamp Meter. Model 38387

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

WARNING CAUTION 1. SAFETY

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

User's Guide. Phase Sequence and Motor Rotation Tester Model

Keysight U1602B and U1604B Handheld Digital Oscilloscopes

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Tone Generator and Probe

Laboratory Switch Mode Power Supply Series. Instruction Manual

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

Wireless TRMS Multimeter and Insulation Tester

General Warranty. For more details, please refer to the user manual, it can be downloaded at

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

80W (16V/5A) Power Supply with USB Output. User Manual

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

CAUTION CAUTION CAUTION HIGH VOLTAGE PRESENT

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Autoranging Mini Multimeter Model MN16A

DM3058/DM3058E Digital Multimeter

Digital Clamp-on Meter Amp Plus. Instruction Manual

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

True RMS Multimeter with IR Thermometer

Transcription:

Power Prowler 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables Quick Start Guide 600V CAT III For Live Energized Cables PLR600 Revison 08/19/13 www.t3innovation.com

Soft key functions are defined on the display above each button. Back Test Enter Direction cursors to move in LCD display On/Off Banana Jacks 600V CAT III DMM Meter Leads 600V CAT III Leader Cable: 5 feet 600V CAT III Flanged Crocodile Clips: red and black 600V CAT III UL/CSA Dual Banana to BNC Female BNC (M) to F Connection (F) 2 Power Prowler Quick Start Guide

Safety Information To ensure safe operation of the Power Prowler, follow the instructions carefully and observe the warning and caution messages listed below. Failure to observe warnings can result in severe injury or death and can damage the unit. Notification Definition The Power Prowler is designed for use on cabling systems with or without voltage. The Voltage! Icon turns on when the voltage exceeds Safety Extra Low Voltage (SELV) rating of 60 Volts peak AC or DC max. Internal components are protected to 600 Volts RMS peak AC or DC max. Operating the Power Prowler when a voltage source exceeds 600 Volts RMS peak AC or DC max may damage the unit and pose a safety hazard for the user. Do not use the Power Prowler or cables if they appear damaged or the unit is not working properly. Verify the Power Prowler s operation by testing a known voltage. Do not use with voltages higher than the Power Prowler s rated voltage (600V). When connecting to energized cabling use appropriate accessories that meet or exceed the cables voltages. Use with caution with voltages greater than 30V AC RMS, 42V AC peak, or 60V DC. Disconnect circuit power and discharge high-voltage capacitors when testing capacitance, continuity, diodes, or resistance. Do not use around explosive or flammable gas. Use only test leads approved by a safety agency and that have the same voltage, amperage, and category as the Power Prowler. Before opening the battery door, remove any connected adapters and cables. Always wear personal protective equipment when working with the Power Prowler. It is recommended to use caution when handling the probes and cable connections on the Power Prowler when the Voltage! Icon is present. Do not place equipment and its accessories in the trash. Items must be properly disposed in accordance with local regulations. T3 Innovation 3

Digital Multi Meter (DMM) Power on the Power Prowler. Use the left or right arrow buttons to highlight the DMM icon, then press enter or use the DMM soft key. Use the left and right arrow buttons to select VDC, VAC, LoZ VAC, Continuity, or Ohms. Press the Hold soft key to keep the displayed value on the screen. Press the Range soft key to manually select the range to be measured. To view the minimum and maximum measurements for AC and DC voltages, select the Min/Max soft key. 4 Power Prowler Quick Start Guide

How to Perform a Fault Location Test Power on the Power Prowler. Connect the proper adapter to the Power Prowler, then connect to the cable under test. Select the Fault location icon using the right arrow button, then press the enter button or press the ruler icon soft key. Use the left or right arrow buttons to scroll to the cable type to be tested.»» To edit an existing cable VOP, use the up and down arrows to change the VOP. Once the desired VOP is displayed, press the save soft key. To cancel, press the cancel soft key, or use the back arrow soft key to return to the test screen without saving the adjusted VOP. To restore the default VOP, press the default soft key.»» If the cable type is not listed, but the VOP is known, press the star soft key to add a custom cable type.»» If the VOP is not known, connect to a known length of the same cable type. Select the CAL soft key and adjust the length by pressing the up/down arrows or press the soft keys under +50ft and -50ft until the length of the cable is displayed. Press the test button to discover the VOP or press the cancel soft key to cancel. T3 Innovation 5

How to Perform a Fault Location Test (Cont d) Note: See Power Prowler Settings for instructions on how to select if a leader cable is or is not being used. The leader cable icon is displayed on the top left of the screen when the leader cable is in use. Press the test button to perform a Fault Location Test. The graphic on the left side of the screen will indicate if there is an open or a short condition. Open Short How to Perform a Live Event Detection Test Power on the Power Prowler. Connect the proper adapter to the Power Prowler, then connect to the cable under test. Use the right arrow button to scroll to the Live Event Detection icon then press the enter button or press the Live Event Detection soft key. Select cable type or edit VOP (refer to Fault Location instructions). Note: See Power Prowler Settings for instructions on how to select if a leader cable is or is not being used. The leader cable icon is displayed on the top left of the screen when the leader cable is in use. Press the test button to begin the test. The Power Prowler will detect any changes to the cable (change in length, open, or short condition). The Power Prowler will stop the test when a change in the cable condition is detected. The graphic on the left side of the screen will indicate if the change is an open or short condition. To stop the test, press the cancel soft key. 6 Power Prowler Quick Start Guide

Power Prowler Settings Power on the Power Prowler. Press the settings soft key to enter the Power Prowler settings menu. Use the up and down arrows to select a setting. Use the left and right arrows to adjust the selected setting. Press the save soft key Press the cancel soft icon to save any edited settings. to cancel and exit the settings menu.»» To select ft/m and Leader/No Leader, use the up or down buttons to highlight the ft/m option. Use the left or right buttons to select the desired option. For additional instructions please visit www.t3innovation.com/powerprowler to download the Power Prowler instruction manual. T3 Innovation 7

Power Prowler Quick Start PLR600 Power Prowler Main Unit DMM Meter Leads 600V CAT III Leader Cable: 5 feet 600V CAT III Flanged Crocodile Clips: red and black 600V CAT III BNC (F) to Double Banana Plug BNC (M) to F Connection (F) Hanging T3 Pouch Optional Accessories Part Number CA009 AD006 CA002 Description Cable Assembly, Power Cord to 3 Banana Plugs 300V Multi-pin Adapter 1000V CAT III BNC (M) to Alligator Clips For complete Power Prowler user manual, technical information and customer support, please visit www.t3innovation.com or send an email to support@t3innovation.com. Contact Numbers: Phone: 805-233-3390 Fax: 805-383-4507 Address: 808 Calle Plano Camarillo, CA 93012 Made in USA With Global Components www.t3innovation.com