Empirical Validation of IES<VE> Simulation in Term of Daylight in Self- Shading Office Room in Malaysia

Similar documents
INTEGRATED BUILDING ENERGY AND LIGHTING SIMULATION IN THE FRAMEWORK OF EU PV LIGHT PROJECT

space is used effectively. Outdoor space components such as fences and trees affect the solar radiation that the building receives. These components a

BUILDING INTEGRATED PHOTOVOLTAICS IN A THERMAL BUILDING SIMULATION TOOL

Parametric Daylight Envelope: shading for maximum performance

IESVE Revit Plug-in User Guide <VE> 6.1

Ecotect is not intuitive. Finding the location of the tools and their purposes is very difficult and time consuming.

Calculation Methods. IES Virtual Environment 6.4 CIBSE Heat Loss & Heat Gain (ApacheCalc)

Development Of A Fast Simulation-aided-design Method For Office Building In Early Design Stage Ziwei Li 1, Borong Lin 1,*, and Hongzhong Chen 1 1 Scho

A lighting simulation tool for the new European daylighting standard

Daylighting. Note: Daylight is typically defined as diffuse light and is very different from sunlight (direct solar radiation).

version: 3/16/2009 A Design Sequence for Diffuse Daylighting Tiffany Otis Christoph Reinhart Harvard Graduate School of Design

SOFTWARE TOOLS FROM BUILDINGS ENERGY SIMULATION

Methods for integrating parametric design with building performance analysis

Energy Efficient Configuration of Non-Conventional Solar Screens Using Hybrid Optimization Algorithm

IESVE Plug-in for Trimble SketchUp Version 3 User Guide

Simplified Formula and Daylighting Performance of External Shading Device for Small Office Room

Control of an Adaptive Light Shelf Using Multi-Objective Optimization

Dynamic facade module prototype development for solar radiation prevention in high rise building

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

Dynamic daylight simulations for façade optimization (and some other applications)

A SIMPLE METHOD OF DETERMINING THE INFLUENCE OF THE OVERHANG ON WINDOW SOLAR GAINS

Guideline to building simulations with MicroShade in IDA ICE. Simulation of MicroShade in IDA ICE. About MicroShade. About IDA ICE

Questions and Answers

40 Thorndike Street Cambridge, MA Glare Potential Analysis - FINAL REPORT February 25, 2014

Combined Daylight and Thermal Calculation Tool for Annual Energy Performance Simulation of Rooms with Advanced Daylight-Controlled Lighting Systems

Urban Building Energy Model: A workflow for the generation of complete urban building energy demand models from geospatial datasets.

Practical use of new visual discomfort probability index in the control strategy for solar shading devices Johnsen, Kjeld

METHODOLOGY FOR NATURAL VENTILATION DESIGN FOR HIGH-RISE BUILDINGS IN HOT AND HUMID CLIMATE

Environmental Controls

SunCast - User Guide. IES Virtual Environment 2013

A guide for the building of daylight scale models

IES Virtual Environment 2014 Release Notes

Shading Calculation for Passive House Certification Discussion and Development of a New Method

ARCH 447 Electrical Services - Lighting

Comparative Daylight Glare Analysis Between Measured and Computer Simulation Predictions

ISSN: [Chenglin* et al., 6(5): May, 2017] Impact Factor: 4.116

solar energy. compared be able to with a low skyscrapers. buildings Solar The the room when the the sky, higher good view

A Parametric Analysis for the Impact of Facade Design Options on the Daylighting Performance of Office Spaces

ENCLOSURE SYSTEMS DESIGN AND CONTROL SUPPORT VIA DYNAMIC SIMULATION-ASSISTED OPTIMIZATION. Vienna, Austria. Bangkok, Thailand

The importance of software's and weather file's choice in dynamic daylight simulations

DAYLIGHTING SIMULATION OF JAPANESE ARCHITECTURE USING ALL SKY MODEL

Lighting: FlucsDL (daylighting)

Integrated Environmental Solutions Virtual Environment Release Notes

Development and Validation of a Radiance model for a Translucent Panel

Journal of American Science 2015;11(11)

Reliable, fast and intuitive daylight simulation for 3D architectural and urban models directly integrated within SketchUp graphic modeler

Access from the University of Nottingham repository: unmarked.

POTENTIAL FOR VIRTUAL DAYLIGHT SENSORS USING DAYLIGHT SIMULATION AND HIGH-RESOLUTION MEASUREMENT OF SOLAR RADIATION

A Simulation-Based Expert System for Daylighting Design

Solar Optical Properties of Roller Shades: Modeling Approaches, Measured Results and Impact on Daylighting Performance and Visual Comfort

Permanent Link:

Using Daylighting Performance to Optimise Façade Design. Colin Rees Consultancy Manager

EVALUATION OF WIND-DRIVEN VENTILATION IN BUILDING ENERGY SIMULATION: SENSITIVITY TO PRESSURE COEFFICIENTS

COMPUTER-OPTIMISED SHADING DESIGN. Dr. Andrew Marsh Welsh School of Architecture, Cardiff University, Wales, UK

Introduction. Abstract

HEED Validated Against the ASHRAE/BESTEST Standard 140

J. Alstan Jakubiec Jeff Neimasz Modeling Dynamic Shading Devices with the DIVA Advanced Shading Module 1 / 30

EUROPEAN RESEARCH PROJECT RE-VIS, DAYLIGHTING PRODUCTS WITH REDIRECTING VISUAL PROPERTIES

Building and HVAC system simulation with the help of

MicroShade datasheet. Type: MS-A Vertical. Application

FlucsDL User Guide <VE> 6.0

FlucsPro User Guide <Virtual Environment> 5.9

Solmetric isv iphone Application. User Manual

SHADING CALCULATIONS FOR PASSIVE HOUSES ACCURACY MATTERS! THE NEW PHIUS SHADING METHODOLOGY

NUMERICAL CALCULATION OF MEAN RADIANT TEMPERATURE AND TEMPERATURE ASYMMETRY FOR COMPLEX ROOM GEOMETRY

RECENT ADVANCES IN SIMULATION-POWERED BUILDING SYSTEMS CONTROL

GOAL-BASED DAYLIGHTING DESIGN USING AN INTERACTIVE SIMULATION METHOD

Building Models Design And Energy Simulation With Google Sketchup And Openstudio Ahmed Y Taha Al-Zubaydi

FlucsDL User Guide IES Virtual Environment 6.4. Lighting

DESIGN SUPPORT SIMULATIONS FOR A DOUBLE-SKIN FAÇADE

The 2016 Legislation.

Powering BIM Capitalizing on Revit for Building Energy Modeling

Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved.

MULTI-OBJECTIVE FACADE OPTIMIZATIO FOR DAYLIGHTI G DESIG USI G A GE ETIC ALGORITHM

Deft User Guide <Virtual Environment> 6.0

A Study on Development of Azimuth Angle Tracking Algorithm for Tracking-type Floating Photovoltaic System

Atrium Design Strategies for Daylighting and Natural Ventilation

EvalDRC: a new, versatile frontend for climate-based daylight assessment with Contribution Photon Mapping

DAYLIGHTING OPTIMIZATION IN SMART FAÇADE SYSTEMS.

A Preliminary Study on Daylighting Performance of Light Shelf according to the Depth of Space

Advanced Tips for Better Translation Autodesk Revit 2010 IES

Charles S. Sanchez, PhD and Zhang Xiaoqin, PhD Energy Research NTU

ONLINE SOFTWARE PLATFORM FOR DEDICATED PRODUCT RELATED SIMULATIONS

Daylight and Sunlight Study 47 Gainsford Road, London E17 6QB

An early design tool/method for assessing the performance of complex fenestration systems

A model study of the daylight and energy performance of rooms adjoining an atrium well

The benefits of FEM-SS-BES (Finite Element Method, State-Space, Building Energy Simulation) modeling exchange for building physics

COMPUTER-OPTIMISED SHADING DESIGN. Dr. Andrew Marsh Welsh School of Architecture, Cardiff University, Wales, UK

Architecture Engineering Training courses : Course BIM Architecture Diploma Revit Architecture 3D Max Vasari Navis Works Photoshop For Architects

IES <Virtual Environment> Tutorial RadianceIES (Version 6.0)

Using Autodesk Ecotect Analysis and Building Information Modeling

Performative Parametric Design of Radiation Responsive Screens

Lecture 4 Form & Space Form Defines Space

Weather station AP 257/51

A PARAMETRIC STUDY ON WINDOW-TO-FLOOR RATIO OF DOUBLE WINDOW GLAZING AND ITS SHADOWING USING DYNAMIC SIMULATION

Building Control GAMMA instabus

3D Modeling and Energy Analysis of a Residential Building using BIM Tools

Parametric BIM-based Energy Simulation for Buildings with Complex Kinetic Façades

IDA Indoor Climate and Energy 3.0 EQUA Simulation AB, January 2002

Simulating Complex Window Systems using BSDF Data

Transcription:

2013, TextRoad Publication ISSN 2090-4304 Journal of Basic and Applied Scientific Research www.textroad.com Empirical Validation of IES<VE> Simulation in Term of Daylight in Self- Shading Office Room in Malaysia Mansour Nikpour 1,2, Mohd Zin Kandar 1, Mohsen Roshan 1,3 1 Department of Architecture, Faculty of Built Environment, Universiti Teknologi Malaysia, Malaysia 2 Department of Architecture, Islamic Azad University, Bam Branch, Iran 3 Department of Architecture, Islamic Azad University, Lahijan Branch, Iran Received: Feb 7 2013 Accepted: March 3 2013 ABSTRACT In order for using building simulation tools, validation of building simulation should be evaluated. Integrated Environmental Solution<Virtual Environment> (IES<VE>) is Considered an environmental simulation tools for analyzing the buildings performance in term of different criteria such as daylighting and heat gain and energy consumption The objective of this study is to test IES simulation software in self shading room in term of daylight through comparison the simulation result with experimental measurement of office room in actual self shading building in Kuala Lumpur Malaysia. Comparative method was used to find out the differences between experimental measurement and simulation result in term of daylight factor as a performance indicator of daylight.. Finding of this study reveals that the differences between simulation result and empirical measurement is in the acceptable range, It can be concluded IES<VE> has enough validity to calculate the amount of daylight factor in self shading rooms. Therefore IES<VE> can be used for developing the design of self shading buildings especially in pre-design stage of self shading office buildings. KEYWORDS: Daylight, Empirical Validation, Simulation Program. Self shading, Office buildings INTRODUCTION Energy Commission Diamond Building is the most recently built at Putrajaya Malaysia. The building form is symbolizing a diamond shape, which creates self-shading effect that eliminates direct sunlight while allowing diffuse daylight. Besides, the building form ratio and extensive use of glazing façade are actually not suitable for tropical climate. However, with the use of self-shading, and some other technologies, this building is successful to achieve energy saving. Due to most of the internal surfaces are in white color to enhance the daylight reflection, a monotonous working environment is created. The diamond form with the Tilting Façade avoid direct sun rays Into building Tilting Façade results in smaller building footprint which allows for more area for landscape. Surrounding landscape reduce heat gain into the building (figure 1) [1]. Figure 1 Energy Commission Diamond Building * Corresponding Author: Mansour Nikpour, Faculty of Built Environment, Universiti Teknologi Malaysia, Johor, 81310, Johor Bahru, Malaysia. Tel: 0060177388722 Email: mnik56@gmail.com 106

Nikpour et al.,2013 IES (VE) software can simulate numerous results for the energy flow and environmental conditions within a building. Beevor (2010) validated the accuracy of the real world testing, and of the ability of IES (VE) simulations to provide accurate building performance data [2]. In order for using building simulation tools, Validation of simulation software should be evaluated. Simulation results were compared with the results of other simulation software or results of standard tests in the process of validation of any simulation tools. CIBSE specified simple methods for verification of simulations[3]. BESTEST is based on comparative testing, by comparing prescribed models with models simulated by the tools. IES virtual environment 5.8.0 is validated with BESTEST[4]. The IES (VE) energy analysis software tool offers high accuracy and interoperability with Building Information Modeling (BIM) tools. Integrated Environment Solutions is a software for integrated building performance analysis, providing tools for thermal analysis, cost planning, lifecycle, airflow, lighting,, in one integrated system. IES (VE) has the capability to store the thermal information about the building. IES (VE) calculates the heat gain calculations and cooling load calculations for a selected design day of the week, and for a range of design months. IES (VE) includes thermal, solar, lighting, energy costs, and heating/cooling load calculations [5]. IES (VE) simulation result passed both the normality test and the equal variance test. In the case of the total energy values, the analysis concluded that there was no considerable statistical difference in the mean values between simulation result and measuring data [5]. A study comparing 20 different building simulation programs concluded that IES (VE) is one of the most comprehensive and complete simulation packages, with its wide range of interlinked modules, and its unrivalled ability to analyze the heating and ventilation and lighting in buildings. The study also reports that IES (VE) has been tested and verified by both CIBSE and ASHRAE [6]. It has been demonstrated that the IES (VE) model is capable of making estimates and predictions to a reasonable level of accuracy for the purpose of examining design changes. It is unreasonable to expect any model to provide perfect predictions, but through the comparison of model predictions against real measurements, a reasonable level of confidence in the IES (VE) model estimates has been achieved [6]. IES (VE) use available data about the mount of direct and diffuse radiation. Results which were derived from IES (VE) hourly were close to calculation results Amount of direct and global radiation used in simulation are derived from the weather file[7]. IES (VE) was selected as the most favorable computer simulation software to evaluate energy efficiency in building industry out of 249 respondents in U.S. by 2009 (Attia et al., 2009). IES (VE) claimed to be the high accuracy simulation software due to its validated system [8]. However the validation of IES<VE> has been investigated by many researcher but The validation of IES<VE> in specific form of building (self-shading) need to be investigated in term of daylight..daylight quality of 2 office rooms in Energy Commission Diamond Building has been investigated by Nikpour, et al.(2012)[9]. MATERIAL AND METHODS This research has been conducted using two different methods, Experimental measurement of daylight in existing self-shading building and simulation of self shading room using simulation program IES<VE> Then experimental measurement result s were compared with simulation results in same condition. Therfore Data Logger and illuminance sensor were used for experimental measurement the amount of global illuminance and work plane illuminance The first step for measuring daylight parameter in Energy Commission Diamond Building was to set date, time and 10 minutes interval between each recording for Data Logger. Then the Data Logger was connected to illuminance sensor. The next step is to locate the devices on the roof top of the Energy Commission Diamond Building without any obstacle of solar radiation. The recording of exterior illuminance was started every 10 minutes by pushing the button LOG. Two individual office rooms were selected for measurement on the 6 th floor. All Geometrical characteristics of each room such as length, width, height, window size, projected ceiling with respect to floor were measured and the compass was used to determine the orientations of each room. The room index should be specified for identified the number of installed illuminance sensors in each office rooms. Equation 1 shows the computed room index for each room. Room index = (width lengths) / [Mounting height (width + length)] (1) 107

Table 1 shows the minimum number of required illuminance sensors according to the value of room index. Table 1: Number of points for work plane illuminance measurement Room index number of points for measurement <1 4 >1 and < 2 9 >2 and < 3 16 >3 25 Based on room index equation, room No.1 need 9 illuminance sensors and work plane illuminance for room No.2 required 4 illuminance devices. The Data Loggers were connected to illuminance sensors and were located at specified measuring positions on the height of work plane, then the amount of work plane illuminance were measured for all positions simultaneously, in addition to compare the mean interior illuminance with mean external illuminance the duration of measurement is recorded. Two selected office rooms in Energy Commission Diamond Building were measured and their physical features were collected and recorded. Table 2 and 3 shows the physical features of these two selected rooms, in addition figures 2,3,4and 5 show the plan and real pictures of surveyed rooms. WWR is determined as the ratio of the window s area to the total gross wall area. For room No. 1, WWR was equal to 0.54 and for room No.2, it was equal to 0.61[9]. Type Table 2: Physical features of measured rooms Floor Level Internal shading Room Plan Shape Artificial lighting Flourescent 1 Individual 6 venetian blind Linear 4 (2 tubes) 2 Individual 6 venetian blind Linear 2 (2 tubes) Table 3: Geometric characteristics of measured rooms Window Height (mm) Cill Height (mm) Window Orientation Ceiling Height (mm) Geometry (W x L x H) (mm) 1 2150 900 East (N10 ) 3600 6650 x 5000 x 3600 2 2150 900 East (N10 ) 3600 4800 x 3000 x 3600 Figure 2Measured room No.1 (plan, Section) 108

Nikpour et al.,2013 Figure 3 Measured room No.1 (Photo) Figure 4 Measured room No.2 (plan, Section) Figure 5 Measured room No.2 (Photo) In the other hand IES<VE> simulation program was used to get simulation result in term of daylight. Therefore two Models were made in IES<VE> under ModelIT option in IES<VE>.The weather data was selected Kuala Lumpure under aplocate. All characteristics of simulated rooms were look like the measured rooms in Energy 109

Commission Diamond building such as geometrical and physical characteristics, wall and window construction type, surface reflectance(figure 6,7) Figure 6 Simulated Room No.1 Figure 7 Simulated Room No.2 Then FlucsDL option under lighting menu was used for lighting analysis. FlucsDL is a module available in IES(VE) for performing day lighting analysis calculations. The menus and toolbars for this view provide tools for performing FlucsDL calculations. The program can perform daylighting analysis using the point-by-point method. Analysis can be performed in single-room mode or in multi-room mode. This tool displays the APLocate dialogue box where it is possible to set the building location. The only items of importance for the lighting calculations are the latitude. The Analysis dialogue box allows running an analysis calculation. Preferences can be set using the Settings followed by Analysis option. Page dialogue box is as shown in figure8: 110

Nikpour et al.,2013 Figure8 Daylight Analysis page After making models with Model IT option in IES (VE). Each selected model was simulated with FlucsDL option which is located under lighting in IES(VE) software. Before lighting simulation, some parameters should be set. Type of illuminance calculation is planar on the horizontal plane for working plane and task areas only. Daylight Analysis have been done under same sky condition with experimental measurement FINDING AND DISCUSSION Working Plane Illuminance This experimental measurement was held on October 11, 2011. Table 4 shows the reported of mean outdoor illuminance for both selected rooms during measurement. In addition the work plane illuminance for each point of selected rooms is shown in Table 5 when lights were off. Table 4: Mean global illuminance during measurement Time Mean global Illuminance During measuring room No.1 41920.00 During measuring room No.2 44645.00 Table 5: Work Plane Illuminance, (Lux) Points A1 A2 A3 B1 B2 B3 C1 C2 C3 Ave Room 1 1591 338 148 1738 352 147 1084 311 132 649 Room 2 1055 267 ----- 915 242 ----- ----- ----- ----- 619.75 Daylight Factor Daylight factor means the probable of each space for using the daylight Equation.2 shows the computed daylight factor by dividing the mean internal work plane illuminance with the mean external illuminance. Daylight factor = (internal illumination/external illumination) 100 (.2) According to MS1525, for having a space with sufficient potential for proper using of daylight, the daylight factor should be above 1.5 %. Table 6 shows the amount of daylight factor in different points of both selected rooms and their averages. Table 6: Daylight factor for two measured rooms Points A1 A2 A3 B1 B2 B3 C1 C2 C3 Average Room 1 3.79 0.8 0.35 4.14 0.83 0.35 2.67 0.74 0.31 1.5 Room 2 2.36 0.59 --- 2.04 0.54 ---- --- ---- --- 1.38 Surface Reflectance Reflectance of each plane is a proportion of to the amount reflected light to the amount of received light by a plane. In order to measure the reflectance of each surface in the room, the amounts of light which were received by 111

illuminance sensor were recorded in two positions of sensor when the sensor was facing to the surface and when the sensor was located in the reverse to the surface. 20, 50 and 70% are acceptable surface reflectance for floor, wall and ceiling respectively. Reflectances of surfaces are 0.70 and 0.78% for walls in room nq.1 and room no.2 respectively. Furthermore surface reflectance were 0.89 and 70% for the ceiling in room no.1 and room no.2 respectively. Therefore surface reflectance for wall and ceiling in both measured office rooms in Energy Commission Diamond building are more than the recommended value for wall and ceiling. Surface reflectance for floor in room no.1 was 20 %. As the floorcovering was carpet, the floor reflectance in room no.1 was by 10% (Table 7)[9]. Table 7: Surface Reflectance (%) Wall Floor Ceiling Room 1 0.70 0.20 0.89 Room 2 0.87 0.10 0.70 For Validation of IES (VE) in this research, two individual office rooms in Energy Commission Diamond Building were modeled in IES (VE) as similar as real measured rooms. Dimensional properties, orientation and construction type of materials were set like the existing rooms in Energy Commission Diamond Building. Simulation result shows that the amount of mean daylight factor were 1.5 and 1.3 for room no.1 and no 2 respectively while the experimental results shows daylight factor 1.5 and 1.38 for room no.1 and no.2 respectively Conclusion Simulation results and experimental measurement in one of office room exactly is same in term of daylight factor. and the differences between simulation results and experimental measurement in the other office room is not more than 10% in term of daylight factor. The comparison between experimental and simulation results shows that IES has enough validity for daylight analysis in term of daylight factor as an important performance indicator of daylight in rooms with inclined walls. Therefore daylight factor can be selected as performance indicator of daylight for conducting the future research in self shading building for daylight analysis. ACKNOWLEDGMENT The authors declare that they have no conflicts of interest in the research. REFERENCES 1. Zain-Ahmed, A., 2008. Integrating Sustainable Energy in Buildings: A Case Study in Malaysia.FAU Conference.14-15 May. Denmark. 2. Beevor, M., 2010. Smart Building Envelopes. London: University Of Cambridge. 3. Rees, S. J., Spitler, J. & Xiao, D., 2002. An Analytical Verification Test Suite for Building Fabric Models In Whole Building Energy Simulation Programs. ASHRAE Transactions. 108 (1): 30-41. 4. Hensen, J.L.M., Dipl. Ing. Marija Trcka, Costola, D., Ir. Pieter-Jan Hoes,Mirsadeghi M., Sulaiman R., Ing. Wiebe Zoon, 2009. State Of The Art inbuilding Performance Simulation for Integrated Solution, Eindhoven: Eindhoven University of Technolog. 5. Chinnayeluka, S. R., 2011. Performance Assessment Of Innovative Framing Systems Through Building Information Modeling Based Energy Simulation. Master thesis. Osmania University. 6. Booth, A., 2009. Modelling and Simulation of Building Physics. Fourth-Year Undergraduate Project in Group D, Robinson College. 7. Waddell, C., Kaserekar, S. & Ten, A., 2010. Solar Gain and Cooling Load Comparison Using Energy Modeling Software. Fourth National Conference of IBPSA-USA. 11 13 August. New York, pp:150-159. 8. Attia, S. & De Herde, A.,2011. Early Design Simulation Tools for Net Zero Energy Buildings: A Comparison of Ten Tools. Proceedings of Building Simulation. 14-16 November. Sydney, Australia. pp:204-211. 9. Nikpour, M., Mohd Zin, K., Mosavi, E. 2012, Investigating Daylight Quality Using Self-Shading Strategy in Energy Commission Building in Malaysia. Journal of Indoor and Built Environment. DOI: 10.1177/1420326X12458512. 112