RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

Similar documents
Blue Gate A Brave Installation guide V 2.4

EA-GSM-Interface-GB.odt

8848 GSM FWT (GATEWAY) USER S MANUAL

SafeLine GL5. Installation manual. A GSM alternative for all of our lift telephones with built-in power supply and battery backup.

GSM FAX Terminal-8848 User's Manual Version 1.1. GSM FAX Terminal User's Manual

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

The Packs Infotel. GSM Converter V2. Installation Manual V7

GSM Fixed Wireless Terminal

UP100-GSM. GSM based intercom and access control. Installation and user manual

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

SC-688 GSM FWT USER S MANUAL

LEITRONIC AG Swiss Security Systems EA-GSM-DIN. GSM-Gateway

Aristel Networks Pty Ltd NEOS Port GSM / 3G* Fixed Wireless Terminal

NEOS3000A GSM Least Cost Wireless Router

NEOS3000A GSM Least Cost Wireless Router

GSM FIXED WIRELESS TERMINAL

Voice Fax. User Manual

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

Aristel AN1001 GSM FIXED WIRELESS TERMINAL MANUAL V4.2. This manual contains important information. Please read before using the equipment.

Aristel AN1001 GSM FIXED WIRELESS TERMINAL MANUAL V4.2. This manual contains important information. Please read before using the equipment.

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

SunComm. Quad Band GSM/PSTN Wireless Terminal SC-355DP. User Manual

Content of delivery - GSM Gateway, art no Antenna SMA, magnet foot, art no GSM Gateway Manual (this document), art no.

SIMADO GFX11/GFX11E Quick Start

Cellulink Smartcell 111L. Cellular Gateway for a Single Analog Line User s Guide

Follow me GSM PSTN gateway. User s manual. Model:P168 P190. CHOUQIN TECHNOLOGY LIMITED 1

HUAWEI FT2260 Home Phone Connect Quick Start

ecoline GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2.0 and higher Document version:

Page 3 Accessoires. Page 4 to 8 Electrical / UTP Liftcable. Page 9 Led light. Page 10 Programming tools

GSM communicator GD-06 Allegro Complete manual

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

Connecting the THP-700RTS to a Telephone and Radio Console - Summary. DynaMetric. Made in USA THP-700RTS

UP200-GSM Intercom and access control unit operating on mobile GSM network

STD Simple Telemetry Application. Owner s Manual

Open gates & doors with your mobile phone.

Chiron Technology. IRIS 8xx Series Alarm over IP Dialler. Installation and User Guide

GSM Fixed Wireless Terminal WT User s Manual

PSTN-GSM Line Converter

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

Should you have any questions, you may inquiry by visiting our local customer care branches or reach us at toll free (STAR-NET) number

USER MANUAL. SAILOR 500/250 FleetBroadband

LEITRONIC AG Swiss Security Systems. System GSM-Nano ( A) GSM-Nano

User's Manual for GSM Gateway(FWT) Model:ET-8264

User Manual for the AN208

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

ProLine GSM. Installation manual

Analog Telephone Adapter Setup for Q-SYS Softphone

Quick Installation guide V1.1

Switch Board for communicator Alarm

Module Technical characteristics

Sprint User Guide. A downloadable, printable guide to your Sprint Phone Connect 4 and its features.

USER S MANUAL. Etross Printed for th edition

The Axesstel TX240G is a dual-band (800/1900Mhz) fixed wireless voice terminal that is perfect for a

GSM GPRS Modem 900 / 1800

AlarmBox-wireless, Type GSM 230V-Box with integrated GSM module and temperature sensor

FWT-8818 GSM Gateway USER S MANUAL

HSPA+ WiFi Router with Voice

Comsec Protection Systems

Installation Manual & User Instructions. MultiCom 500

Link GSM idp Manual v1.0

EZ864 UMTS Terminal Telit Cellular GSM Engine

GSM GATE VT 10. version 5.4 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC, Issued on May 16, 2007

Quick Reference Guide. For more information go to:

Alarm button Contact GSM-1M

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Installation Manual & User Instructions

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,

SIMADO GFX11 Fixed Cellular Terminal for Voice Applications

MUSITEL 52 T, 53T & 61E GSM GATEWAY. SimBox. User Manual. Checklist Packaging list, please check the contents of your unit: Models: 52T, 53T and 61E

GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone

DIGITAL ENHANCED CORDLESS TELEPHONE with Caller ID Function CL-3350 INF USER' S MANUAL

Aton H61 User Guide. en

Alcatel DECT 209 Wireless PBX System

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

User s Guide. Nokia is a registered trademark of Nokia Corporation, Finland Nokia Mobile Phones. All rights reserved.

GPRS Pager 3 INSTALATION AND USER MANUAL

SC-013G 3G FWT SC-013G 3G FWT. (Fixed Wireless Terminal) User Manual (V1.1)

EAR 1000 / ADRA 1000 / Installation and Programming Manual

GSM GPRS Modem 900 / 1800

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

Installation Manual & User Instructions. MultiCom 100 / 500

GSM communicator G16 USER MANUAL

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

CCTR-628 Long Standby Time GPS Tracker Using Guide

1 BUTTON GSM INTERCOM WITH KEYPAD (3G)

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

Installation Guide for Vodafone Cordless

INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

Getting Started How to insert the SIM card

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

MSS-UP200-GSM Single Dwelling GSM Intercom Unit. Operation Manual. [Ver /5/2015]

Fixed Wireless Phone. User Manual

4 PORTS GSM FIXED WIRELESS TERMINAL. User manual

A very quick guide to getting online

GPRS MODULE. Daily report and Error Message

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

USER MANUAL FEATURES

Transcription:

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK-1201 Assembled by : Engineer: Installation date : Phone number elevator : PIN : PUK: Battery changed on date : Name : Keep this manual on a save place, preferably in the logbook in the machineroom The RUKRA GSM / PSTN interface replaces a standard PSTN landline and can be installed in the engine room, the elevator shaft or on the roof of the cabin. Up to 5 RUKRA Elevator Phones can be connected parallel to one RUKRA GSM / PSTN interface. The RUKRA GSM / PSTN interface is simlock free and equipped with an internal battery. Comes with magnetic antenna, internal battery and a power adapter with 230VAC power cord with molded plug and is ready for immediate use without programming. No programming required, you only need an active SIM-card with or without PIN. The SIMcard can be protected against theft using PIN 1111, with this function the RUKRA GSM / PSTN interface make itself a new unknown PIN code. Read this manual carefully before you start the installation or programming RUKRA EUROPE B.V. WWW.RUKRA.EU INFO@RUKRA.EU

FEATURES 230 VAC / 9VAC powersupply with integreted backup battery Phone line for up to 5 RUKRA Elevator Phones or other brands elevator phones Every 14 days automatic control of the capacity of the backup battery Theft protection with function PIN 1111, there will be a new unknown PIN code generated Additional USB interface for use as a GSM modem (data, programming SMS, SMS, Mail) Roaming can be switched off (Roaming is communication between different networks abroad) Send SMS periodically from 1 to 30 days with information on network, power, temperature, etc. send SMS on the status of the power supply and battery status (power, voltage, capacity and battery defect) send SMS when they login to a network Send SMS when an input is activated (optional print) EXTERNAL CONNECTIONS RUKRA Elevator Phone (maximimum 5 pieces parallel) INTERNAL CONNECIONS The box can be opened without tools 1) Backup battery 9,6V / 800Mah 2) Connector Backup battery 3) Battery checker (BCH) 4) Be carefull when mounting BCH, always keep first pin free!! 5) Reset to facatorysettings: Disconnect the power supply and battery connection and place a wire jumper in this 2- pin connector. Connect the battery or power supply back on, LEDs will flash briefly and you can again remove the jumper, the factory settings are set now. INSTALLATION Use only the supplied 230VAC / 9VAC power adapter and the supplied 2-wire phone cord. Note: A 4 or 6 wire phone cord may cause interference and the yellow and green LEDs will blink. The RUKRA GSM / PSTN interface can be installed in the engine room, the lift shaft or on the roof of the elevator cabin. Always connect the 230VAC adapter to a fixed voltage (never on the cabin lights), always check if the RUKRA GSM / PSTN interface operates on only the power of the battery and only on the 230VAC / 9VAC power adapter. Install the RUKRA GSM / PSTN interface and the antenna always as far away from the RUKRA Lift Phone. The back of the housing is equipped with two slots for mounting and there is double sided tape included for attachment. 2

SIM CARD The SIM card can be used in two ways: without a PIN-Code or PIN-Code Without PIN-Code: 1- Install the sim card in a regular mobile phone. 2- Go to the menu "Security Settings" and set the option "Request PIN" on "OFF" With PIN-Code: 1- Install the sim card in a regular mobile phone. 2- In the Security settings menu, change the PIN code to 1111. 3- When the SIM card is inserted in the RUKRA GSM/PSTN Interface, the code will be changed to a random number, thus making it impossible to use the card in another mobile phone unless it is unblocked by means of the PUK code. Insert the SIM card into the RUKRA GSM / PSTN interface (note the angled corner) and connect the power supply adapter and the battery backup power alternately and check the LEDs to go on both times. The blue LED turns on and the green and yellow LEDs will flash. Wait an average of 60 seconds until the middle LED goes off and the lower LED continues to flash 1 to 5 times, the RUKRA GSM / PSTN interface is ready for use now. PROGRAMMING From the factory the RUKRA GSM / PSTN interface is set with standard settings which have normally not te be changed. Programming can be connected with a normal PSTN phone or by the USB interface. With a PSTN telephone: With an attached phone, you can change the parameters but you can not change phone numbers and SMS settings. Programming can be with or without the presence of a SIM card. With the USB interface: SMS settings, phone numbers and all other parameters can be programmed with a computer using the "GGSET" program and the USB Interface. Programming can be done with and without the presence of a SIM card. Programming procedure with a PSTN phone: Connect a phone to the line out, lift the handset and enter: # 0000 (0000 = default password) as the password is correct you will hear one after another short dial tones. After entering a correct setting you will hear three tones and then you dial hedge (#) and you hear a longer confirmation tone. Wait until you hear at least 2 short dialtones and then continue with programming. PARAMETER VALUE DESCRIPTION FACTORY SETTING 0 0 n n n n Password for programming 0 0 0 0 2 7 n Ask for PIN, n =0 Ask PIN disabled / n =1 Ask PIN enabled 0 7 5 n Roaming, 0 = Roaming OFF / 1 = Roaming ON 1 3 2 n n Waiting time after calling the numbers (2N setting n n = 1 0) 0 1 9 9 Reset to factorysettings 3

Programming procedure with the USB interface: the RUKRA GSM / PSTN interface can be programmed with a computer and the necessary software "GGSET" and the USB interface. The USB interface is connneted with a 6 conductor flat cable to the RUKRA GSM / PSTN interface. Parameters that are programmed with an attached phone can also be programmed with the PC except the PIN code of the SIM card. Phone numbers for SMS messages can only be programmed with a computer using the "GGSET" program and the USB Interface. Programming can be with or without the presence of a SIM card. On the website www.rukra.eu you can download the required software and the manual "Configuration software for RUKRA GSM / PSTN interface" USB Interface: You can control RUKRA GSM/PSTN interface directly via the USB Interface. The RUKRA GSM/PSTN interface can further be used like an ordinary GSM modem for data transmission, internet connection or for SMS messages. When the RUKRA GSM/PSTN interface is working as GSM modem then it is busy for voice connection. When you pick up the line you will hear busy tone. The RUKRA GSM/PSTN interface is monitoring data transmission by modem. The data transmission can not be permanent therefore the RUKRA GSM/PSTN interface stays in data mode 10 seconds after finishing of data transmission. Then is going back to Voice mode (calling). The same is when you are calling over RUKRA GSM/PSTN interface. It is busy for data transmission. The optional software supply to unit for sending and receiving SMS messages is SMS mail. It is working under Outlook and you can work with SMS as with normal e mails. It works in batches and allows programm communication interval (1 to 99 minutes) to RUKRA GSM/PSTN interface for sending and receiving SMS. Due this we avoid situation that the RUKRA GSM/PSTN interface is permanentlky blocked by data mode for voice communication. Further functionality of USB is monitoring RUKRA GSM/PSTN interface operation. It is possible record even incoming calls includes time and CLIP, signal strength, etc.. 4

MEANING OF THE LED S Manual Permanent light (lights up after power connection) Power supply or battery of GSM unit 10 seconds on, and off for 1 second PIN-code is wrong, can not read PIN-code Permanent light line OFF HOOK Doesnt light line ON HOOK Flashing in rhytm of busy tone Programming or PC connection mode Flashing in rhytm of busy tone Initialization mode after power supply connection, restart after programming etc.. 1-5 flashes with period 4 sec. stand by mode. Number of flashes = signal strength Permanent light GSM connection is running (call) Short lights off with period 2 sec. GSM modul doesnt communicate to CPU Flashing in period 2sec SIM is not ready Short flashes in period 2 sec. Gate is not registrate to GSM network SOLUTIONS FOR PROBLEMS All LED are not lighting:problem in power supply. Check connection to main 230V as same as connection of adapter to RUKRA GSM/PSTN interface and the connection of the internal battery. The LED power supply lights. When you make connection to RUKRA GSM/PSTN interface green LED is ON and in handset you hear busy tone. Yellow LED flashing in period GSM modul doesnt communicate with CPU. During work with USB could be programmed fix communication rate for GSM modul. Use USB to programm rate on autobauding. The yellow LED flashing in period PIN unreadable. After calling to RUKRA GSM/PSTN interface you get busy tone. The SIM card requires PIN, which is not preprogrammed or is preprogrammed wrongly. The LED communication to GSM is flash shortly one for 2 sec. After calling to RUKRA GSM/PSTN interface you are hearing busy tone. RUKRA GSM/PSTN interface is not log into GSM network bad signal. The yellow LED communication to GSM is flashing up signal strength. After calling to RUKRA GSM/PSTN interface Green LED is not light up and in analogue phone is quiet. It interrupted conduction of analogue line or so much big resistance in current loop (for example:(too long cabel between elevator and RUKRA GSM/PSTN interface). The RUKRA GSM/PSTN interface works but call is disturbed by interference. Incorrect position of antenna against telephone line. Change antenna position. 5

TECHNICAL SPECIFICATIONS Power Powersupply : 9VAC / 1000mA (ONLY USE THE SUPPLIED RUKRA POWER ADAPTER) Protection : Thermal fuse in powersupply Battery : 9,6V / 800MAh Dimensions : H x W x D - 130 x 100 x 36mm Type antenna connector : SMA (MAN) SMS MESSAGES SMS messages can only be programmed and activated with a computer Batteriycheck (BCH) : The battery voltage, capacity and battery or absence will be checked automatically. If There is something wrong with the battery an SMS will be send one phone number. The following SMS messages can be send: ACCU DEATH OR NOT CONNECTED = battery defect or not connected (check battery) POWER ACCU LOW (CONTROL 230V) = Power battery is low (Fault with 230V) CAPACITY ACCU LOW (CHANGE ACCU) = Capacity of the battery is low (replace battery) NOTE!! BATTERY MESSAGES ARE SENT ONCE AN EVENT Login network Network / linetest :Every time the RUKRA GSM interface is logged into the network a SMS message will be send to one phone number :The RUKRA GSM interface can send periodic ( 1 to 30 days) a SMS message to one phonenumber with information about the battery, last number called, temperature and signal strength. Analog PSTN phone connection Phoneconnector : RJ12 6/2 Impedantie : 600Ω ±20% Calling : Tone DTMF t > 30ms Voltage of the line : 24V Current of the line : 29mA Ringvoltage : 55V / 50Hz Signaling : 425Hz ± 20% Caller ID : FSK / CLIP Start and end connection : Polarity reversal Cable length : Maximum 200meter (from the RUKRA GSM/PSTN interface to the elevatorphone) Programming : USB interface or with connected PSTN phone GSM Module Fabricated : Telit GL865-DUAL Mobile network : GSM-module, quadband 850/900/1800/1900 MHz Sim Card : 3V en 1,8V CE 0889 : The CE symbol indicates that the product complies with the European directives. WARRANTY: Time Battery : 1 Year Carry in after deliveringdate : No warranty on the battery RUKRA EUROPE B.V. WWW.RUKRA.EU INFO@RUKRA.EU TEL: +31 33 711 39 34 6