DLS 5405 Operating Manual High Bandwidth Noise Injection Unit

Similar documents
EOS-6000 Series Optical A/B Switch User Manual DC Version

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Agilent 70612B K18 Switch Matrix

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Broadband Automatic Disconnect Switch. User Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Model VT120 Fast Timing Preamplifier Operating and Service Manual

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide

User Guide. Control Box. RoscoLED TM.

DLS 8130 Operating Manual VDSL2 Wireline Simulator North America

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Kramer Electronics, Ltd. USER MANUAL. Model: VM-80HP. 1:8 Stereo Headphone Distributor

Line Impedance Stabilization Network (LISN)

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

iconverter 2-Module Power Chassis

Model 7705 Control Module

87421/22A Power Supply. Operating and Service Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

MPF-1, Mains Power Filter User Manual

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

User's Guide. Extech AM A AC Analog Clamp Meter

User s Guide. 600A AC Clamp Meter. Model 38387

Agilent OBSAI Protocol Tester

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

USER MANUAL. Kramer Electronics, Ltd. Models:

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

Kramer Electronics, Ltd. USER MANUAL. Model: VM-50AN. 1:5 Audio Distributor

Automated Tuner System Power Distribution Hub

Resolver to Digital Expansion Board

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200XLN. XGA Line Amplifier / DA

TDM-150 TIMER DISPLAY

USB Ranger 422 User Guide

Kramer Electronics, Ltd.

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Burson Audio DA-160 Audio DAC User Manual

User s Manual Power Supply IM E. 5th Edition

PS8 - II. Professional Power Sequencer. User s Manual

Kramer Electronics, Ltd. USER MANUAL

Sonic Ruptor 400. User Manual

TDM-170 TIMER DISPLAY

Model 4001A Modular System Bin Operating and Service Manual

Series 8000 RF Signal Switch Solution

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Model Channel TTL I/O

USB Ranger 110/410 User Guide

User's Guide. Model High Precision Quad Output DC Power Supply

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

1-36V, 0-3A DC Power Supply

Logitech Alert 700i/750i System Requirements & Support Guide

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

PSA200 User s Manual

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Model 7026 (1x32) 2-wire Multiplexer

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

VIP-812A DUAL NETWORKED STATION PORT

User s Guide. POWERVAR Single Phase Power Conditioners

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Model 2657A-LIM-3 LO Interconnect Module

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

USB 3.0 Spectra

UTAH-100/XHDA SERIES

HV-CS kv Edge Mount Triaxial Jack

Kramer Electronics, Ltd. USER MANUAL. Model: VP-2x2. 2x2 XGA/Audio Matrix Switcher

Product Documentation

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

User's Guide. Phase Sequence and Motor Rotation Tester Model

MTS-2000 USER S MANUAL

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

CiM-25. Quick Start Guide. IP-Enabled M&C Part Number CD/CIM25QSG.IOM Rev. 0

PCM-7140 Pulsed Current Source Operation Manual

Mini Digital Multimeter

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

SLA Battery Capacity Analyzer

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver

Installation Job Aid for Ethernet Routing Switch 3600 Series

Perle MCR200 Installation Guide

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Kramer Electronics, Ltd.

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Transcription:

DLS 5405 Operating Manual High Bandwidth Noise Injection Unit October 2005 71-000042 Revision B

DLS 5405 Operating Manual Copyright Notice 2005 Spirent Communications Manual Part Number 71-000042 Revision B All rights reserved. This manual is subject to change without notice. No part of this manual may be copied, reproduced, stored in a retrieval system, or transmitted in any form, or by any means, electronic, mechanical, or otherwise, without the prior written permission of Spirent Communications. Spirent Communications makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Trademarks Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Sun and Solaris are registered trademarks of Sun Microsystems, Inc. in the United States and other countries. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company Limited. Any other trademarks are the property of their respective owners. Spirent Communications 71-000042 Revision B

Contents DLS 5405 Operating Manual 1: Overview 1-1 1.1 Introduction... 1-1 1.2 Product Features... 1-1 1.3 System Level Block Diagram... 1-1 2: Getting Started 2-1 2.1 Receiving And Unpacking The Unit... 2-1 2.2 Quick Start Set Up... 2-1 2.3 Front Panel Connections... 2-2 2.4 Back Panel Connections... 2-4 2.5 DLS 5405 Control Software... 2-6 2.6 Calibration Setup... 2-6 3: Customer Support 3-1 3.1 Customer Service Contact Information... 3-1 3.2 Protecting Your Investment... 3-1 4: Warranty 4-1 5: Shipping The Unit 5-1 6: Specifications 6-1 7: Safety 7-1 7.1 Information... 7-1 7.1.1 Protective Grounding (Earthing)... 7-1 7.1.2 Before Operating the Unit... 7-1 7.1.3 Power Supply... 7-1 7.1.4 Fuses... 7-1 7.1.5 Connections to a Power Supply... 7-1 7.1.6 Operating Environment... 7-2 7.1.7 Class of Equipment... 7-2 7.2 Instructions... 7-2 7.2.1 Before Operating the Unit... 7-2 7.2.2 Operating the Unit... 7-2 7.3 Symbols... 7-3 Spirent Communications 71-000042 Revision B i

DLS 5405 Operating Manual 1. Overview 1.1 Introduction The DLS 5405 is the interface between a noise generator and a wireline simulator. It injects separate VDSL2 noise signals at either end of a wireline simulator. The DLS 5405 is 1U high and can be mounted in a standard 19" rack. 1.2 Product Features The DLS 5405 Dual VDSL2 Injection Unit product features include: Up to 40 MHz bandwidth noise injection (differential outputs). Maximum output level of -3 dbm for a signal with a crest factor of 5.0. Two RJ-45 jacks per side, one for the DUT (Device Under Test), one for the wireline simulator. Four 50 Ω unbalanced BNC noise inputs (two each for Side A and Side B). 1.3 System Level Block Diagram Figure 1-1 DLS 5405 System Level Block Diagram Spirent Communications 71-000042 Revision B Page 1-1

Chapter 1: Overview Noise profiles are supplied to the DLS 5405 by the DLS 5500. Each side must have two noise profiles connected to it, as shown in Figure 2-5 on page 2-5. The two noise signal inputs per side are summed by the DLS 5405 and output in differential mode at the injection point (DUT and Wireline jacks) on the front panel. The injection network is disconnected from the outputs (DUT and Wireline jacks) when the DLS 5405 is off or when first powered up. When the injection network is connected to the outputs (by a command from the DLS 5500), the injector loads the line slightly. The normally closed contacts between the DUT and Wireline jack are open momentarily for micro-interruption tests only, otherwise they remain closed. Page 1-2 71-000042 Revision B Spirent Communications

DLS 5405 Operating Manual 2. Getting Started 2.1 Receiving And Unpacking The Unit Each DLS 5405 chassis is shipped in a reinforced shipping container. Please keep this container in case you need to ship the wireline simulator to another location or for repair. The DLS 5405 system contains the following: AC power cable. Linear power supply (Spirent # DLS 5P02). Three RJ-45 (1 foot long) Spirent # 7102040514. Two RJ-45 short cables for Modem/DSLAM connections Spirent # 7102040525. DB-25 Interface serial cable. Check that you have received all the items on the list and report any discrepancies to Spirent Communications. 2.2 Quick Start Set Up The DLS 5405 High Bandwidth Noise Injection Unit works in conjunction with a DLS 5500 VDSL2 Noise Generator to inject noise at either end of a wireline simulator. For details on noise generation, see the DLS 5500 Operating Manual. NOTE Keep all interconnecting cables as short as possible. Follow these steps to set up and operation the DLS 5405: Step 1: Connect the outputs of the DLS 5405 to the inputs on the DLS 8130 wireline simulator using the RJ-45 cables provided with the DLS 5405 (see Figure 2-2). Step 2: Connect each output at the back of the DLS 5500 to an input at the back of the DLS 5405 as shown in Figure 2-5 on page 5. Use short 50 Ω coaxial cables with BNC connectors at each end. Step 3: Connect the RS-232 port at the back of the DLS 5405 (labelled DB-25 ) to one of the COM ports at the back of the DLS 5500 VDSL2 Noise Generator using the supplied serial cable. NOTE The DLS 5405 must be connected to the noise generator to activate noise injection. Step 4: Select the correct input voltage on the power supply for your area (115 or 230 VAC). Step 5: Connect the external power supply to an AC power source. Step 6: Connect the 5 pin linear power supply cord to the Power IN connector at the back of the DLS 5405. Step 7: Switch on the power supply. Spirent Communications 71-000042 Revision B Page 2-1

Chapter 2: Getting Started Step 8: On the DLS 5500 VDSL2 Noise Generator, select Start >> Programs >> Spirent Communications >> DLS 5500 >> DLS 5500. The DLS 5405 Control Application will start. Step 9: Select System >> Injector Loss from the menu bar in the control application main window. The Injector Loss dialogue box will open. Step 10: Choose the serial port to which the DLS 5500 is connected from the Communications drop-down list. Step 11: Click the Connect button. Step 12: Verify that the power and remote LED's on the front panel of the DLS 5405 are green. Step 13: Start tests. 2.3 Front Panel Connections Figure 2-1 DLS 5405 front view The front panel of the DLS 5405 contains the two noise injection points (Side A and Side B). Each injection point uses two RJ-45 jacks so that both the DUT and to the wireline simulator can be connected to the injection point. There are two status lights on the front panel. A green Power LED indicates that power is connected and the DLS 5405 has not detected any internal faults. A green Remote LED indicates that the DLS 5405 is communicating properly with the noise generator. All cables must be kept as short as possible for accurate wireline simulation. They must also be kept as far apart from each other as possible. The recommended setups (Figure 2-2 and Figure 2-3) yields the shortest interconnection cabling possible. The recommended configuration for VDSL2 North American Wireline Configuration is shown in Figure 2-2. It consists of a DLS 8130 wireline simulator, a DLS 5500 VDSL2 Noise Generator, and a DLS 5405 VDSL2 Noise Injector. The recommended configuration for ADSL2++ North American Wireline Configuration is shown in Figure 2-3. It consists of a DLS 410 wireline simulator, a DLS 5500 VDSL2 Noise Generator, and a DLS 5405 VDSL2 Noise Injector. For connections between the wireline simulators and DUT (Device Under Test), use the supplied 2-foot long cables (Spirent #7102040526). For connections between the DLS 5405 noise injector and the wireline simulators, use the supplied 1-foot long cables (Spirent # 7102040514). Page 2-2 71-000042 Revision B Spirent Communications

DLS 5405 Operating Manual Figure 2-2 VDSL2 North American Wireline Configuration Spirent Communications 71-000042 Revision B Page 2-3

Chapter 2: Getting Started Figure 2-3 ADSL2++ North American Wireline Configuration 2.4 Back Panel Connections Figure 2-4 DLS 5405 back view Each of the four noise signals generated by the DLS 5500 are connected to the four unbalanced BNC inputs at the back of the DLS 5405, using four 50 Ω coaxial cables (Figure 2-5). Connect the DLS 5500 to the DLS 5405 as shown in Figure 2-5. Page 2-4 71-000042 Revision B Spirent Communications

DLS 5405 Operating Manual The DLS 5405 and DLS 5500 must also be connected by a serial cable. The DLS 5405 will not function without it. Power to the DLS 5405 is supplied by an external power supply, and connected at the back of the unit. NOTE The power supply must be set to the correct line voltage for your area (115 or 230 VAC). Figure 2-5 DLS 5500, DLS 5405 And DLS 8130 wireline configuration (back view) Spirent Communications 71-000042 Revision B Page 2-5

Chapter 2: Getting Started 2.5 DLS 5405 Control Software The DLS 5405 is controlled by the noise generator via an RS-232 connection. The noise generator includes all necessary control software. 2.6 Calibration Setup Figure 2-6 illustrates the recommended setup for measuring noise profiles from the DLS 5405 High Bandwidth Noise Injection Unit. Note the following points when setting up for measurements: 1) Cabling between the Balun and the noise injector must be very short. Spirent recommends a maximum length of two inches. 2) Connect the center tap to the balun s metal case. 3) The frequency response of the balun transformers must be considered. Spirent recommends that you use the following North Hills balun transformers, depending on the frequency range: Frequency Range North Hills Balun Model 1 KHz 15 MHz 0311LB 100 KHz 40 MHz 0301BB Figure 2-6 Measuring electrical characteristics Page 2-6 71-000042 Revision B Spirent Communications

DLS 5405 Operating Manual 3. Customer Support 3.1 Customer Service Contact Information For all North American customers, please direct any questions or concerns regarding the operation of a purchased unit, to the Spirent Communications Customer Service team by one of the following methods: Toll Free: (800) 774-7368 Telephone: (613) 592-7301 Fax: (613) 592-0522 Internet: Email: http://support.spirentcom.com ae.service@spirentcom.com All other customers should check the Customer Service Center (CSC) website at: http://support.spirentcom.com for the contact information of the nearest Customer Service center or contact the main Spirent Communications service center for assistance (contact information is listed above). The most recently published user manuals, application notes, software and firmware updates are available on the CSC website. 3.2 Protecting Your Investment Spirent Communications is committed to providing the highest quality products and customer support possible. An annual calibration is required to ensure that your unit is operating properly. Spirent Communications is pleased to offer two cost effective optional service programs. Each of these programs is designed to improve the ease and efficiency of servicing Spirent Communications test equipment. Extended Warranty Spirent Communications' Extended Warranty gives two years in addition to the original one-year manufacturer s warranty. Under the warranty agreement, Spirent Communications repairs any covered product that needs service during the warranty period. At the time of repair, any required firm ware and/or software upgrades are installed free of charge and if required as part of the repair, the unit receives a complete calibration. Spirent Communications also provides return shipment of any unit covered under warranty at Spirent Communications s cost. The Extended Warranty gives: Extension of the original one-year limited warranty by two years (giving a total warranty coverage of three years). Required firm ware and software upgrades installed free at time of repair. If required because of a repair, free calibration due to repair during the coverage period. Prepaid, return shipment of repaired products worldwide. Spirent Communications 71-000042 Revision B Page 3-1

Chapter 3: Customer Support Spirent Communications' Extended Warranty can be purchased at any time up until the expiration of the original one-year manufacturer's warranty. Three-Year Calibration Agreement Spirent Communications three-year calibration agreement gives the opportunity to invest in a yearly calibration for three years at a significant cost saving, ensuring optimum product performance. Specific Spirent Communications products are shipped with a National Institute of Standards and Technology (N.I.S.T.) traceable calibration that expires one year from the original ship date. With ISO-9000 and other manufacturer specific metrology requirements, timely calibrations become critical to your operations. Spirent Communications sends out an e-mail reminder when the next calibration is due. A report containing all calibration data is shipped with the product. The Spirent Communications s three-year calibration agreement gives: Three yearly N.I.S.T traceable calibrations (one per year). Notification from Spirent Communications when calibration is due. Calibration data report. Prepaid return shipment of calibrated unit worldwide. The Spirent Communications three-year calibration agreement may be purchased at any time. Please contact Spirent Communications Customer Service for more information on these programs, or visit us on the web at ae.spirentcom.com. Page 3-2 71-000042 Revision B Spirent Communications

DLS 5405 Operating Manual 4. Warranty Spirent Communications warrants all equipment bearing its nameplate to be free from defects in workmanship and materials, during normal use and service, for a period of twelve (12) months from the date of shipment. In the event that a defect in any such equipment arises within the warranty period, it shall be the responsibility of the customer to return the equipment by prepaid transportation to a Spirent Communications service centre prior to the expiration of the warranty period for the purpose of allowing Spirent Communications to inspect and repair the equipment. If inspection by Spirent Communications discloses a defect in workmanship or material it shall, at its option, repair or replace the equipment without cost to the customer and return it to the customer by the least expensive mode of transportation, the cost of which shall be prepaid by Spirent Communications. In no event shall this warranty apply to equipment which has been modified without the written authorization of Spirent Communications, or which has been subjected to abuse, neglect, accident or improper application. If inspection by Spirent Communications discloses that the repairs required are not covered under this warranty, the regular repair charges shall apply to any repairs made to the equipment. For international customers, please contact your local Spirent Communications sales representative or check the ae.spirentcom.com web site for the contact information of the nearest service center. In North America, if warranty service becomes necessary, the customer must contact Spirent Communications to obtain a return authorization number and shipping instructions: Spirent Communications Toll Free: 1-800-SPIRENT International calls: +1 818-676-2616 Support Email: Web: ae.service@spirentcom.com http://support.spirentcom.com This warranty constitutes the only warranty applicable to the equipment sold by Spirent Communications, and no other warranty or condition, statutory or otherwise, expressed or implied, shall be imposed upon Spirent Communications nor shall any representation made by any person, including a representation by a representative or agent of Spirent Communications, be effective to extend the warranty coverage provided herein. In no event (including, but not limited to the negligence of Spirent Communications, its agents or employees) shall Spirent Communications be liable for special consequential damages or damages arising from the loss of use of the equipment, and on the expiration of the warranty period all liability of Spirent Communications whatsoever in connection with the equipment shall terminate. Spirent Communications 71-000042 Revision B Page 4-1

DLS 5405 Operating Manual 5. Shipping The Unit To prepare the unit for shipment, turn the power off, disconnect all cables (including the power cable) and pack the unit in its original carton. Do not place any cables or accessories directly against the front panel as this may scratch the surface of the unit. It is highly recommended that all shipments are marked with labels indicating that the contents are fragile. If sending a unit back to the factory, ensure that the Return Material Authorization (RMA) number given by the Spirent Communications Customer Service department is shown on the outside. The RMA number is mandatory and must be obtained from a Spirent Communications Customer Service center before shipping the unit (see Section 3 "Customer Support" for details on how to contact the nearest Spirent Communications Customer Service center). Spirent Communications 71-000042 Revision B Page 5-1

DLS 5405 Operating Manual 6. Specifications INJECTION POINT Number of injection points: Injection Mode Bandwidth 2 Differential 4 khz to 40 MHz Noise Floor: 4 khz to 100 khz: < -140 dbm/hz 100kHz to 40MHz < -150 dbm/hz NOISE INPUTS Noise Inputs: Input Mode Input Impedance: Power Loss * (between input and injection point) Frequency Response (with calibration load) Uncompensated: 4 (two for each side) Unbalanced 50 Ω 15.3 db ±0.25 db at 20 MHz relative to 20 MHz < ±0.5 db from 10 khz to 30 MHz WIRELINE Injector Insertion Loss < 0.1 db (4 khz to 40 MHz) Maximum Signal Output: -3 dbm (per output) assuming a crest factor of 5.0 Maximum Wireline Voltage: 200V DC + peak AC (tip to ring) *See notes next page Spirent Communications 71-000042 Revision B Page 6-1

Chapter 6: Specifications *Notes: 1) All specifications for levels and gains assume an input load of 50 Ω, and that the output is terminated with the calibration load. 2) The calibration load normally consists of two nominally 100 Ω loads in parallel (see Figure 2-6 "Measuring electrical characteristics" on page 2-6). By definition, the output power is the power in ONE of these resistors. 3) The calibration load for a small number of files is defined differently than in 2) above. Refer to the relevant ETSI standard for SDSL testing. Chassis: Height, Width, Depth: Weight: Power Supply: 1U rack mount chassis 1.75" (44mm), 19.0: (482mm), 17.75" (451mm) 8 lbs. (3.6 kg) 5P02 (switchable, 115 or 230 VAC) Environment: Operating Temperature: 5 to 40 C Humidity: Compliance: 95% non-condensing CSA, UL (ENTELA) CE, FCC for home and office usage Page 6-2 71-000042 Revision B Spirent Communications

DLS 5405 Operating Manual 7. Safety 7.1 Information 7.1.1 Protective Grounding (Earthing) This unit consists of an exposed metal chassis that must connect directly to a ground (earth) via a protective grounding conductor in the power cord. The symbol used to indicate a protective grounding conductor terminal in the equipment is shown in this section under symbols. 7.1.2 Before Operating the Unit Inspect the equipment for any signs of damage, and read this manual thoroughly. Become familiar with all safety symbols and instructions in this manual to ensure that the equipment is used and maintained safely. WARNING To avoid risk of injury or death, ALWAYS observe the following precautions before operating the unit: Use only a power supply cord with a protective grounding terminal. Connect the power supply cord only to a power outlet equipped with a protective earth contact. Never connect to an extension cord that is not equipped with this feature. Do not wilfully interrupt the protective earth connection. The protective conductor terminal must be attached to the mains supply earth. CAUTION When lifting or moving the unit, be careful not to apply any pressure to the plastic grid which is located on the bottom of the chassis, toward the front right corner. Lift the chassis by gripping it on both sides at the bottom, ensuring not to touch the plastic grid. 7.1.3 Power Supply WARNING To avoid electrical shock, do not operate the equipment if it shows any sign of damage to any portion of its exterior surface, such as the outer casting or panels. 7.1.4 Fuses The fuse type used is specified in the specifications chapter of this manual. 7.1.5 Connections to a Power Supply In accordance with international safety standards, the unit uses a three-wire power supply cord. When connected to an appropriate AC power receptacle, this cord grounds the equipment chassis. Spirent Communications 71-000042 Revision B Page 7-1

Chapter 7: Safety 7.1.6 Operating Environment To prevent potential fire or shock hazard, do not expose the equipment to any source of excessive moisture. 7.1.7 Class of Equipment The equipment consists of an exposed metal chassis that is connected directly to earth via the power supply cord. In accordance with HARMONIZED EUROPEAN STANDARD EN 61010-1:1993, it is classified as Safety Class I equipment. WARNING This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 7.2 Instructions The following safety instructions must be observed whenever the unit is operated, serviced or repaired. Failing to comply with any of these instructions or with any precaution or warning contained in the Operating Manual is in direct violation of the standards of design, manufacture and intended use of the equipment. Spirent AE assumes no liability for the customer s failure to comply with any of these requirements. 7.2.1 Before Operating the Unit Inspect the equipment for any signs of damage, and read the Operating Manual thoroughly. Install the equipment as specified in the relevant section of this manual. Ensure that the equipment and any devices or cords connected to it are properly grounded. WARNING The maximum signal between Tip and Ring must not exceed ±200 V. Exceeding this limit could damage the unit. 7.2.2 Operating the Unit Do not operate the equipment when its covers or panels have been removed. Do not interrupt the protective grounding connection. Any such action can lead to a potential shock hazard that could result in serious personal injury. Do not operate equipment if an interruption to the protective grounding is suspected. Ensure that the instrument remains inoperative. Use only the type of fuse specified. Do not use repaired fuses and avoid any situation that could short circuit the fuse. Unless absolutely necessary, do not attempt to adjust or perform any maintenance or repair procedure when the equipment is opened and connected to a power source at the same time. Any such procedure should only be performed by qualified service professional. Do not attempt any adjustment, maintenance or repair procedure to the equipment if first aid is not accessible. Page 7-2 71-000042 Revision B Spirent Communications

Chapter 7: Safety Disconnect the power supply cord from the equipment before adding or removing any components. Operating the equipment in the presence of flammable gases or fumes is extremely hazardous. Do not perform any operating or maintenance procedure that is not described in the Operating Manual. Some of the equipment s capacitors may be charged even when the equipment is not connected the power source. 7.3 Symbols When any of these symbols appear on the unit, this is their meaning: EQUIPOTENTIALITY FUNCTIONAL EARTH TERMINAL PROTECTIVE GROUNDING CONDUCTOR TERMINAL CAUTION - REFER TO ACCOMPANYING DOCUMENTS Page 7-3 71-000042 Revision B Spirent Communications