OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Similar documents
OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 45

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

PIM-Mini Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual

Resolver to Digital Expansion Board

Profibus DP Expansion Board

DCM Digital Control Modules

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

User Guide. Control Box. RoscoLED TM.

FA-2448 SIX POSITION Filter Wheel

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Relay Board. User Manual. 1.0, Oct 2013

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

SATA II HDD Canister KISS DA 435 Quick Reference Guide

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

TB-100 ControLynx Terminal Block

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

TDM-170 TIMER DISPLAY

Model VT120 Fast Timing Preamplifier Operating and Service Manual

ACLD Channel Opto-isolated Digital Input Board

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

FTC-200 X-ray Tube Controller Users Manual

I/O SIGNAL CONDITIONER

TDM-150 TIMER DISPLAY

Install Motor Controller User Manual

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Proliphix EPA-60 Installation Guide

User s Guide. POWERVAR Single Phase Power Conditioners

User Manual TLS HDMI Switch Splitter 3/2

DIGITAL VOLTAGE INDICATOR

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

DeviceNet Expansion Board

Digital Electronic Lock OWNER S MANUAL

PROFIBUS DP Option. for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1911

Model 3526-B Digi-Probe Multimeter

Automated Tuner System Power Distribution Hub

Model 7705 Control Module

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

iconverter 2-Module Power Chassis

PSA200 User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

HD-1X4-4K User Manual

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

WARRANTY & LIMITATION OF LIABILITY

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

User's Guide. MiniTec TM Series Model MN25 MultiMeter

OP8/16 Optoisolated Digital Input Board User's Manual

FNet Repeater Installation & Operator s Instruction Manual

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

User's Guide. Model High Precision Quad Output DC Power Supply

LCI Load Cell Junction Box with Fault Monitor

User's Guide. Extech AM A AC Analog Clamp Meter

Broadband Automatic Disconnect Switch. User Manual

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

AL5812EV3 User Guide 150mA, 60V Low-side Adjustable Linear LED Driver

SC-9

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

TSD-SEQ6 Sequencer Controller

1-36V, 0-3A DC Power Supply

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

NAS LCP CONTROLLER WITH PANEL FACEPLATE

Sonic Ruptor 400. User Manual

AMT-12 AMT-15. Professional Loudspeakers. Installation and Use Manual

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

LCI User Manual mantracourt.com

VIP-812A DUAL NETWORKED STATION PORT

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

COBEX RECORDERS, INC.

WS115 BREAKOUT ADAPTER USER MANUAL

VK-3iX WARRANTY REGISTRATION FORM

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Power Quality Recorder

Three Channel XLR Balanced Patch Bay. Artcessories. User's Manual

Enhanced Mini-Chansim Model VCS-232

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

OPERATING INSTRUCTIONS FOR MODEL ST-15 5-DIGIT SPORTS TIMER

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

User s Guide. 600A AC Clamp Meter. Model 38387

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Application Guide. M 2174B Moloney Replacement Adapter Panel

User's Guide. Phase Sequence and Motor Rotation Tester Model

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply

3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

PS8 - II. Professional Power Sequencer. User s Manual

Transcription:

OPERATING AND SERVICE MANUAL Universal Interface Device 47

MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202

SAFETY NOTICE Universal Interface Device 47 (UID47) connects two or more power supplies for master/slave configurations or for other user configured applications. Before applying power to the system, verify that the system is configured properly for the specific application and that ratings are not exceeded on any input or output terminal. Installation and service must be performed only by properly trained and qualified personnel who are aware of dealing with electrical hazards. Ensure that the ac power line ground is properly connected to the power supply chassis. Furthermore, other power grounds, including those connected to application maintenance equipment, must be grounded for both personnel and equipment safety. Always ensure that facility ac input power is de-energized prior to connecting or disconnecting the input and output power cables. Caution: While the UID47 is a low voltage device, lethal voltages may be present inside the connecting power supply even when the ac input voltage is disconnected. Only properly trained and qualified personnel should remove covers and access the inside of the power supply. During normal operation, the operator does not have access to hazardous voltages within the cabinet. Depending on the user s application, high voltages hazardous to human safety may be generated normally on the output terminals of the connecting power supply. Ensure that the output power cables are properly labeled as to the safety hazards and that any inadvertent contact with hazardous voltages is eliminated. The connecting power supply is designed to be permanently connected to the power source requiring a readily accessible disconnect device incorporated in the fixed wiring. These operating instructions form an integral part of the equipment and must be available to the operating personnel at all times. All the safety instructions and advice notes are to be followed. Neither Magna-Power Electronics, Inc. nor any of the associated sales organizations can accept responsibility for personal injury, consequential injury, loss, or damage that results from improper use of the equipment and accessories. i

LIMITED WARRANTY The following is made in lieu of all warranties expressed or implied. Magna-Power Electronics, Inc. warranties its products to be free of manufacturing defects for a period of two (2) years from date of original shipment from its factory. Magna-Power Electronics, Inc. will repair, replace, or refund the purchase price at its discretion, which upon examination by Magna-Power Electronics, Inc., is determined to be defective in material or workmanship, providing such claimed defective material is returned upon written authorization of Magna-Power Electronics, Inc., freight prepaid. For products failing within the first 30 days of the warranty period, Magna-Power Electronics, Inc. will return the repaired product at its expense using a standard shipping method; after 30 days of the warranty period, the repaired product will be returned at the customer s expense using the customer s requested shipping method. Damage due to corrosion, customer alterations, excessive dust, extreme environmental or electrical conditions, and/or misuse will be evaluated upon inspection. If inspection reveals that the cause of damage is not due to materials or workmanship, repair of the product will be treated on a non-warranty basis. All electrical, commercial supply parts, and items not manufactured by Magna-Power Electronics, Inc. shall carry the warranty of the original manufacturer and no more, but under no circumstances to exceed the warranty period. Replacement parts shall be warranted for a period of 90 days. Warranty labor shall only apply if the product, assembly, or part is returned to the factory freight prepaid and insured. Damage or breakage while in transit is not covered by this warranty. Magna-Power Electronics, Inc. assumes no responsibility to Buyer for labor to diagnose and remove defective product and installation of replacement product. Furthermore, Magna-Power Electronics, Inc. is not liable to Buyer or to any third party for consequential or incidental damages under any circumstances, whether due to defect in the product, due to delay or failure of delivery, due to a failure of the product to perform as specified, or for any other reason or cause. Buyer and Magna-Power Electronics, Inc. agree that Buyer s sole remedy and Magna- Power Electronics, Inc. s sole liability to Buyer is limited to repair, replacement, or refund of the purchase price of the product as described herein, whether Buyer s claim arises out of contract or in tort. All claims against the warranty shall be the final determination of Magna-Power Electronics, Inc. ii

CLAIM FOR DAMAGE IN SHIPMENT This instrument received comprehensive mechanical and electrical inspections before shipment. Immediately upon receipt from the carrier, and before operation, this instrument should be inspected visually for damage caused in shipment. If such inspection reveals internal or external damage in any way, a claim should be filed with the carrier. A full report of the damage should be obtained by the claim agent and this report should be forwarded to us. We will then advise you of the disposition to be made of the equipment and arrange for repair or replacement. When referring to this equipment, always include the model and serial number. RETURNING EQUIPMENT Before returning any equipment to the factory, the following steps should be taken:. Contact our technical service department. Give a full description of the difficulty and include the model and serial number of the unit. On receipt of this information, we will give you service information or shipping instructions. 2. Packaging and method of shipment must be coordinated with the factory to insure safe delivery. All equipment returned for repair require a Return Authorization Number and must be insured. No returns will be accepted without assignment of a Return Authorization Number. 3. For non-warranty repairs, we will submit a cost estimate for your approval before proceeding. iii

TABLE OF CONTENTS Section Title Page.0 GENERAL INFORMATION. Description.2 Features.3 IEC Symbols Used in Manual.4 Power Requirements. Specifications 2.0 INSTALLATION AND OPERATION 4 2. General 4 2.2 Master/Slave Parallel Operation 4 2.3 Master/Slave Series Operation 7 2.4 Custom Configurations 8 iv

.0 GENERAL INFORMATION. Description This manual contains operation and maintenance instructions for Magna-Power Electronics' Universal Interface Device 47 (UID47). The UID47 allows users to connect power supplies for master/slave parallel or series operation or allows connections to external control circuitry with easy access screw terminals..2 Features The UID47 is a general purpose device for connection to Magna-Power Electronics XR Series III, TS Series IV, MS Series IV, and MT Series VI power supplies. The device contains the necessary circuitry for configuring power supplies for master/slave parallel or series operation. Master/slave parallel operation allows two or more power supplies to equally share output current when connected together. Master/slave series operation allows two or more power supplies to equally share output voltage when connected together. The UID47 can be used as an interface for connecting control and monitoring lines to external circuitry. It also contains an area on the printed circuit board for interconnecting wires and placing components for specific user applications..3 IEC Symbols Used in Manual The following IEC symbols are used in this manual. Caution, risk of electric shock Caution, risk of danger Protective conductor terminal Three-phase alternating current.4 Power Requirements None. Specifications

The following specifications describe the published operational characteristics of the UID47. UID47 connectors, see figure. for details: JR,2,3: 37 pin D-subminature, female JR4: 0 pin plug connector Size:.20"H x 7.40"W x 4.00"D, see figure.2 for details. Weight: 6.4 oz. 37 9 20 (a) 0 (b) Figure. UID47 connectors (a) JR,2,3 and ( b) JS4 (viewed from UID47) 2

Figure.2 UID47 Enclosure 3

2.0 INSTALLATION AND OPERATION 2. General The UID47 is a general purpose device for connection between Magna-Power Electronics XR Series III, TS Series IV, MS Series IV, and MT Series IV power supplies and user devices. Figure 2. shows the electrical circuit of the UID47 and figure 2.2 shows jumpers connections for master/slave parallel and series operation. The following sections describe how to use the device for master/slave parallel and series operation and for custom applications. Caution: As shipped, the UID47 is configured for master/slave parallel operation. 2.2 Master/Slave Parallel Operation Two or more Magna-Power Electronics power supplies can be connected in parallel to obtain a total output current greater than that available from one power supply. The total output current is the sum of the output currents of the individual power supplies. Each power supply can be turned on or off separately. Master/slave parallel operation permits equal current sharing under all load conditions and allows complete control of output current from one master power supply. To configure the power supplies for master/slave parallel operation, disconnect power to the power supplies and connect all units and loads in parallel as shown in Figure 2.3. Remove the cover of the UID47 and set the jumpers settings according to Figure 2.2 for master/slave parallel configuration. This is the factory default setting. Replace the cover and connect a 37-conductor male to male cable from connector JS of the master power supply to connector JR2 of the UID47. Connect a second 37-conductor male to male cable from connector JS of the slave power supply to connector JR of the UID47. The jumper settings perform the following functions:. Jumper connection between terminals 2,26 connects the slave power supplies current monitoring outputs, ISO, to the master power supply current monitoring input, ISI. This allows the current of all slave power supplies to be summed along with that of the master power supply. 2. Jumper connection between terminals 23,24 connects the control lines between the master and slave power supplies. Command of the control line is automatically selected with the jumper connections. 4

JR4 JX3 USER USER2 USER3 USER4 USER USER6 USER7 USER8 USER9 USER0 8 8 2 3 4 6 7 2 3 4 6 7 9 0 9 0 JP 2 3 4 6 7 8 9 0 2 3 4 6 7 8 9 20 2 22 23 24 2 26 SLAVE CONNECTION JR JX2 JX JR3 JR2 9 9 VO2 REF GND 20 VO2 0 0 24 IO2 IO2 VMOD VMOD 2 2 2 2 2 6 6 6 +2.V REF CAL +2.V REF CAL 2 2 3 3 2 REF GND REF GND 20 2 2 20 REF GND REF GND REF GND 2 2 4 4 2 +0V REF +0V REF 3 3 3 VREF EXT VREF EXT 22 22 6 6 22 IREF EXT IREF EXT 4 4 7 7 4 TVREF EXT TVREF EXT 23 23 8 8 23 TIREF EXT TIREF EXT 3 3 32 32 3 ISI ISI 6 6 3 3 6 ISO ISO 36 36 34 34 36 ARM ARM 8 8 3 3 8 CLEAR CLEAR 37 37 36 36 37 INTERLOCK SET INTERLOCK SET 9 9 37 37 9 STOP STOP 7 7 33 33 7 START START 7 7 3 3 7 GND GND 26 26 4 4 26 +V +V 3 3 24 24 3 CONTROL CONTROL 2 2 23 23 2 STANDBY/ALARM STANDBY/ALARM 32 32 26 26 32 OCT OCT 3 3 2 2 3 ALM ALM 33 33 28 28 33 INT CTL INT CTL 4 4 27 27 4 EXT CTL EXT CTL 34 34 30 30 34 OVT OVT 29 29 FUSE FUSE 27 27 6 6 27 PGM LINE PGM LINE 8 8 8 POWER POWER 28 28 8 8 28 STANDBY STANDBY 9 9 7 7 9 THERMAL THERMAL 29 29 20 20 29 PHASE LOSS PHASE LOSS 0 0 9 9 0 INTERLOCK INTERLOCK 30 30 22 22 30 VOLT CTL VOLT CTL 2 2 CUR CTL CUR CTL 24 24 MASTER CONNECTION Figure 2. Schematic of UID47 JP 2 3 4 6 7 8 9 0 2 3 7 9 2 23 2 4 6 8 20 22 24 26 JP 2 3 4 6 7 8 9 0 2 3 7 9 2 23 2 4 6 8 20 22 24 26 MASTER/SLAVE PARALLEL MASTER/SLAVE SERIES (a) (b) Figure 2.2 Jumper JP settings for (a) master/slave parallel and (b) master/slave series

3. Jumper connection between terminals,2; 9,0;,6 sets the external voltage and current set points to zero. This enables control of the slave power supplies from the master power supply. 4. Jumper connection between terminals,2 connects the power output digital control line of the master power supply to the start digital control line of the slave power supplies. This connection causes slave units to turn on when the master unit is turned on.. Jumper connection between terminals 3,4 connects the standby/alm digital control line of the master power supply to the stop digital control line of the slave power supplies. This connection causes the slaves units to turn off when the master unit is turned off or when a diagnostic condition appears. 6. Jumper connections between terminals 3,4;,6; 7,8 set the slave voltage trip and over current trip set points just beyond full scale values. The slave power supplies must be configured for external program input. The master unit can be configured for rotary, keypad, external program, or remote input. Refer to the power supply manual for setting the configuration commands. Three or more parallel connected power supplies can be interconnected by applying additional UID47 units; one UID47 is required for every slave power supply. As illustrated in figure 2.3 for two slave power supplies, follow the previous instructions plus connect an additional 37- conductor male to male cable from JS of the second slave power supply to JR of the second UID47. Connect a 37-conductor male to male cable between connector JR3 and JR2 of the two UID47 units. Interconnecting UID47 units routes master control and monitoring signals to all of the slave power supplies. TO THIRD SLAVE JR3 USER INTERFACE DEVICE 4 JR JR2 CURRENT VO+ MODE CONTROL JS SLAVE JR CURRENT VO+ MODE CONTROL JS CURRENT VO+ MODE CONTROL JS JR3 JR SLAVE LOAD SLAVE LOAD JR2 JS VO+ JR2 JS VO+ USER INTERFACE DEVICE 4 MASTER USER INTERFACE DEVICE 4 MASTER (a) (b) Figure 2.3 Master/slave parallel connection for (a) one or (b) more slave power supplies 6

2.3 Master/Slave Series Operation Two or more power supplies can be connected in series to obtain a total output voltage greater than that available from one power supply. The total output voltage is the sum of the output voltage of the individual power supplies. Each power supply can be turned on or off separately. Caution: Two or more power supplies may be connected in series. For models rated 000 V or less and regardless of the number of units or the voltage ratings of the series connected power supplies, the voltage potential from any output terminal to chassis ground should not exceed 000 Vdc. For models rated greater that 000 V and regardless of the number of units or the voltage ratings of the series connected power supplies, the voltage potential from any output terminal to chassis ground should not exceed 2000 Vdc + VO/2 where VO is the output voltage of the power supply. Master/slave series operation permits equal voltage sharing under all load conditions and allows complete control of output voltage from one master power supply. To configure the power supplies for master/slave series operation, disconnect power to the power supplies and connect all units and loads in series as shown in Figure 2.4. Remove the cover of the UID47 and set the jumpers settings according to Figure 2.2 for master/slave series configuration. Replace the cover and connect a 37-conductor male to male cable from connector JS of the master power supply to connector JR2 of the UID47. Connect a second 37-conductor male to male cable from connector JS of the slave power supply to connector JR of the UID47. The jumper settings perform the following functions:. Jumper connection between terminals 7,8 connects the voltage monitoring voltage, VO2, on the master power supply to the external voltage set point input on the slave power supplies. This makes the slave power supplies operate at the same voltage output as the master power supply 2. Jumper connection between terminals,2 connects the power output digital control line of the master power supply to the start digital control line of the slave power supplies. This connection causes the slave units to turn on when the master unit is turned on. 3. Jumper connection between terminals 3,4 connects the standby/alm digital control line of the master power supply to the stop digital control line of the slave power supplies. This connection causes the slave units to turn off when the master unit is turned off or when a diagnostic condition appears. 4. Jumper connections between terminals,2; 3,4;,6; 7,8;,6 set the slave current set point to maximum and the voltage trip and over current trip set points just beyond full scale values. 7

The slave power supply must be configured for external program input. The master unit can be configured for rotary, keypad, external program, or remote input. Refer to the power supply manual for setting the configuration commands. Three or more series connected power supplies can be interconnected by applying additional UID47 units; one UID47 is required for every slave power supply. As illustrated in figure 2.4 for two slave power supplies, follow the previous instructions plus connect an additional 37- conductor male to male cable from JS of the second slave power supply to JR of the second UID47. Connect a 37-conductor male to male cable between connector JR3 and JR2 of the two UID47 units. Interconnecting UID47 units routes master control and monitoring signals to all of the slave power supplies. TO THIRD SLAVE JR3 USER INTERFACE DEVICE 4 JR JR2 VOLTAGE VO+ MODE CONTROL JS SLAVE JR VOLTAGE VO+ MODE CONTROL JS JR3 JR VOLTAGE VO+ MODE CONTROL JS SLAVE SLAVE LOAD LOAD JR2 JS VO+ JR2 JS VO+ USER INTERFACE DEVICE 4 MASTER USER INTERFACE DEVICE 4 MASTER (a) (b) Figure 2.4 Master/slave series connection for (a) one or (b) more slave power supplies 2.4 Custom Configurations The UID47 permits users to design and implement their own control circuitry to control or monitor the power supply s inputs or outputs. As shown in figure 2., the UID47 has a general purpose area on its printed circuit board to configure custom circuitry or to provide interconnections to utilize connector JR4. Table 2. shows the interface of master and slave connectors JR through JR3 with corresponding pad areas of JX and JX2. Connectors JR2 and JR3 are interconnected to allow daisy chain connections for multiple UID47 units. JR4 is a 0 terminal connector that mates to a screw terminal plug. This connector is user defined 8

and can be utilized to externally monitor or control power supply functions. Table 2.2 shows the interface of connector JR4 and the corresponding pad area. For example, connecting a wire from terminal of JX3 (USER) to terminal of JX provides a signal to indicate the master power supply is operational. The multipurpose area in the center of the PCB enables the user to add circuitry within the UID47. The multipurpose area provides sufficient space to add components like or ing diodes for simultaneously monitoring two diagnostic signals. One example is to connect the anodes of two diodes to the OCT and OVT alarm signal and interconnect the cathodes. This provides a diagnostic signal on either the OCT or OVT alarm signal. Table 2. JR JR2 JR3 2 3 4 6 7 8 9 0 2 3 4 6 7 8 9 JX JX2 CONNECTION INTERFACE DESCRIPTION FOR JR, JR2, AND JR3 3 7 9 3 7 9 2 23 2 27 29 3 33 3 37 Description REF GND REF GND VREF EXT TVREF EXT VO2 +2.V REF CAL GND POWER THERMAL INTERLOCK CUR CTL STANDBY/ALM ALM EXT CTL FUSE ISO START CLEAR STOP JR JR2 JR3 20 2 22 23 24 2 26 27 28 29 30 3 32 33 34 3 36 37 JX JX2 2 4 6 8 0 2 4 6 8 20 22 24 26 28 30 32 34 36 Description REF GND +0V REF IREF EXT TIREF EXT IO2 VMOD +V PGM LINE STANDBY PHASE LOSS VOLT CTL CONTROL OCT INT CTL OVT ISI ARM INTERLOCK SET 9

Table 2.2 CONNECTION INTERFACE DESCRIPTION FOR JR4 JR4 JX3 Description 2 3 4 6 7 8 9 0 2 3 4 6 7 8 9 0 USER USER2 USER3 USER4 USER USER6 USER7 USER8 USER9 USER0 Figure 2. Printed circuit board layout of the UID47 0