SECTION DISCONNECT SWITCHES

Similar documents
SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

1510 MOTOR CONTROLLERS

SECTION PANELBOARDS

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. 4. Electronic-grade panelboards.

SECTION PANELBOARDS

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

SECTION SWITCHGEAR

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION SWITCHBOARDS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III 100% CONSTRUCTION DOCUMENTS

1. Coordination of series-rated devices is permitted where indicated on Drawings.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

PANELBOARDS: SIGNIFICANT (OR TOTAL) DELETION OF EXISTING TEXT

Emery County Senior Center Green River 06/07

A. Operation and Maintenance Data: For the overcurrent protective devices to include in emergency, operation, and maintenance manuals.

SECTION WIRING DEVICES

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

SECTION DISTRIBUTION SWITCHBOARDS

Free Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL

Tmax molded case circuit breakers Specification guide

920 Remote Control (RC) Switches

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

SECTION SURGE PROTECTIVE DEVICES

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

ASCO 920 Remote Control (RC) Switches

Application Techniques CENTERLINE 2100 Motor Control Centers

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Document C0. Use for:

60103 Circuit Breaker

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

PDI Modular Compact Remote Power Panel

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Bulletin Installation of solar photovoltaic systems Rules , , , , and

SECTION LOW-VOLTAGE VARIABLE FREQUENCY DRIVES

SACE Emax 2 Specification guide

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Power-Style QED-2, Series 2 Low Voltage Switchboards

SECTION WIRING DEVICES

Quick Start Guide TS A

BuildingName The Description of the Project P DOCUMENTS

Section 4 Ground-Fault Protection Devices


E-Series General Specifications

Common Departures Interconnecting Facilities Requirements

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

SECTION WIRING AND CONTROL DEVICES

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Time Delay Values (E-Series)

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

INSTALLATION INSTRUCTIONS

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

1. Division 26 Section "Motor-Control Centers" for VFCs installed in motor-control centers.

PowerFlex 400 AC Drive Guide Specification

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads.

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

SECTION ( ) LIGHTING CONTROL PANELBOARD

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

UL 489 DIN Rail Miniature Circuit Breakers

POWER SYSTEMS STUDY: SIGNIFICANT (OR TOTAL) DELETION OF EXISTING TEXT

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

UL 489 DIN rail branch circuit breakers

UL 489 DIN Rail Miniature Circuit Breakers

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

WMS SUPPLEMENTARY PROTECTORS

3RV1 Circuit-Breakers

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

Magnetically Actuated Safety Interlock Switches

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

White Paper. UL Standards for Power Control System Equipment

Protection Equipment

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Transcription:

SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section. 1.02 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Shunt trip switches. 4. Molded-case circuit breakers (MCCBs). 5. Molded-case switches. 6. Enclosures. 1.03 DEFINITIONS A. NC: Normally closed. B. NO: Normally open. C. SPDT: Single pole, double throw. 1.04 PERFORMANCE REQUIREMENTS A. Seismic Performance: Enclosed switches and circuit breakers shall withstand the effects of earthquake motions determined according to ASCE/SEI 7. 1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces specified and the unit will be fully operational after the seismic event." 1.05 SUBMITTALS A. Product Data: For each type of enclosed switch, circuit breaker, accessory, and component indicated. Include dimensioned elevations, sections, weights, and manufacturers' technical data on features, performance, electrical characteristics, ratings, accessories, and finishes. 1. Enclosure types and details for types other than NEMA 250, Type 1. 2. Current and voltage ratings. 3. Short-circuit current ratings (interrupting and withstand, as appropriate). 4. Include evidence of NRTL listing for series rating of installed devices. 04/01/2013 BID DOCUMENTS Noel MS 16440-1

5. Detail features, characteristics, ratings, and factory settings of individual overcurrent protective devices, accessories, and auxiliary components. 6. Include time-current coordination curves (average melt) for each type and rating of overcurrent protective device; include selectable ranges for each type of overcurrent protective device. B. Shop Drawings: For enclosed switches and circuit breakers. Include plans, elevations, sections, details, and attachments to other work. 1. Wiring Diagrams: For power, signal, and control wiring. C. Operation and Maintenance Data: For enclosed switches and circuit breakers to include in emergency, operation, and maintenance manuals. In addition to items specified in Division 01 Section "Operation and Maintenance Data," include the 1. Manufacturer's written instructions for testing and adjusting enclosed switches and circuit breakers. 2. Time-current coordination curves (average melt) for each type and rating of overcurrent protective device; include selectable ranges for each type of overcurrent protective device. 1.06 QUALITY ASSURANCE A. Source Limitations: Obtain enclosed switches and circuit breakers, overcurrent protective devices, components, and accessories, within same product category, from single source from single manufacturer. B. Product Selection for Restricted Space: Drawings indicate maximum dimensions for enclosed switches and circuit breakers, including clearances between enclosures, and adjacent surfaces and other items. Comply with indicated maximum dimensions. C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. D. Comply with NFPA 70. 1.07 COORDINATION A. Coordinate layout and installation of switches, circuit breakers, and components with equipment served and adjacent surfaces. Maintain required workspace clearances and required clearances for equipment access doors and panels. 1.08 EXTRA MATERIALS A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Fuses: Equal to 10 percent of quantity installed for each size and type, but no fewer than three of each size and type. 2. Fuse Pullers: Two for each size and type. 04/01/2013 BID DOCUMENTS Noel MS 16440-2

PART 2 - PRODUCTS 2.01 FUSIBLE SWITCHES B. Type HD, Heavy Duty, Single Throw, 600-V ac, 1200 A and Smaller: UL 98 and NEMA KS 1, horsepower rated, with clips or bolt pads to accommodate indicated fuses, lockable handle with capability to accept three padlocks, and interlocked with cover in closed position. C. Accessories: 1. Equipment Ground Kit: Internally mounted and labeled for copper and aluminum ground conductors. 2. Neutral Kit: Internally mounted; insulated, capable of being grounded and bonded; labeled for copper and aluminum neutral conductors. 3. Isolated Ground Kit: Internally mounted; insulated, capable of being grounded and bonded; labeled for copper and aluminum neutral conductors. 4. Class R Fuse Kit: Provides rejection of other fuse types when Class R fuses are specified. 5. Auxiliary Contact Kit: Two NO/NC (Form "C") auxiliary contact(s), arranged to activate before switch blades open. 6. Hookstick Handle: Allows use of a hookstick to operate the handle. 7. Lugs: Mechanical type, suitable for number, size, and conductor material. 2.02 NONFUSIBLE SWITCHES B. Type HD, Heavy Duty, Single Throw, 600-V ac, 1200 A and Smaller: UL 98 and NEMA KS 1, horsepower rated, lockable handle with capability to accept three padlocks, and interlocked with cover in closed position. C. Accessories: 1. Equipment Ground Kit: Internally mounted and labeled for copper and aluminum ground conductors. 2. Neutral Kit: Internally mounted; insulated, capable of being grounded and bonded; labeled for copper and aluminum neutral conductors. 3. Isolated Ground Kit: Internally mounted; insulated, capable of being grounded and bonded; labeled for copper and aluminum neutral conductors. 4. Auxiliary Contact Kit: Two NO/NC (Form "C") auxiliary contact(s), arranged to activate before switch blades open. 04/01/2013 BID DOCUMENTS Noel MS 16440-3

5. Hookstick Handle: Allows use of a hookstick to operate the handle. 6. Lugs: Mechanical type, suitable for number, size, and conductor material. 2.03 MOLDED-CASE CIRCUIT BREAKERS B. General Requirements: Comply with UL 489, NEMA AB 1, and NEMA AB 3, with interrupting capacity to comply with available fault currents. C. Thermal-Magnetic Circuit Breakers: Inverse time-current element for low-level overloads and instantaneous magnetic trip element for short circuits. Adjustable magnetic trip setting for circuit-breaker frame sizes 250 A and larger. D. Adjustable, Instantaneous-Trip Circuit Breakers: Magnetic trip element with front-mounted, field-adjustable trip setting. E. Electronic Trip Circuit Breakers: Field-replaceable rating plug, rms sensing, with the following field-adjustable settings: 1. Instantaneous trip. 2. Long- and short-time pickup levels. 3. Long- and short-time time adjustments. 4. Ground-fault pickup level, time delay, and I 2 t response. F. Current-Limiting Circuit Breakers: Frame sizes 400 A and smaller, and let-through ratings less than NEMA FU 1, RK-5. G. Integrally Fused Circuit Breakers: Thermal-magnetic trip element with integral limiter-style fuse listed for use with circuit breaker and trip activation on fuse opening or on opening of fuse compartment door. H. Ground-Fault, Circuit-Interrupter (GFCI) Circuit Breakers: Single- and two-pole configurations with Class A ground-fault protection (6-mA trip). I. Ground-Fault, Equipment-Protection (GFEP) Circuit Breakers: With Class B ground-fault protection (30-mA trip). J. Features and Accessories: 1. Standard frame sizes, trip ratings, and number of poles. 2. Lugs: Mechanical type, suitable for number, size, trip ratings, and conductor material. 3. Application Listing: Appropriate for application; Type SWD for switching fluorescent lighting loads; Type HID for feeding fluorescent and high-intensity discharge lighting circuits. 4. Ground-Fault Protection: Comply with UL 1053; integrally mounted, self-powered type with mechanical ground-fault indicator; relay with adjustable pickup and time-delay settings, push-to-test feature, internal memory, and shunt trip unit; and three-phase, zerosequence current transformer/sensor. 5. Shunt Trip: Trip coil energized from separate circuit, with coil-clearing contact. 04/01/2013 BID DOCUMENTS Noel MS 16440-4

6. Undervoltage Trip: Set to operate at 35 to 75 percent of rated voltage without intentional time delay. 2.04 ENCLOSURES A. Enclosed Switches and Circuit Breakers: NEMA AB 1, NEMA KS 1, NEMA 250, and UL 50, to comply with environmental conditions at installed location. 1. Indoor, Dry and Clean Locations: NEMA 250, Type 1. 2. Outdoor Locations: NEMA 250, Type 3R. PART 3 - EXECUTION 3.01 EXAMINATION A. Examine elements and surfaces to receive enclosed switches and circuit breakers for compliance with installation tolerances and other conditions affecting performance of the Work. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.02 INSTALLATION A. Install individual wall-mounted switches and circuit breakers with tops at uniform height unless otherwise indicated. B. Install fuses in fusible devices. C. Comply with NECA 1. 3.03 IDENTIFICATION A. Comply with requirements in Division 26 Section "Identification for Electrical Systems." 1. Identify field-installed conductors, interconnecting wiring, and components; provide warning signs. 2. Label each enclosure with engraved metal or laminated-plastic nameplate. 3.04 ADJUSTING A. Adjust moving parts and operable components to function smoothly, and lubricate as recommended by manufacturer. B. Set field-adjustable circuit-breaker trip ranges as specified in Division 26 Section "Overcurrent Protective Device Coordination Study". END OF SECTION 16440 04/01/2013 BID DOCUMENTS Noel MS 16440-5