TS Series. Description

Similar documents
TS Series. TS Series. Fieldbus System. TRUNKSAFE Fault Tolerant. May F. Fieldbus System

RM100. ROUTE-MASTER Fieldbus System (Intrinsically-Safe Installations)

HIT/HIX HART Isolator

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

TG200 TG200. (General Purpose and Non-Incendive Locations) May E

SIY. New. Features! Features. PC-Programmable Signal Isolator/Converter

5 Fieldbus Technology

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

SDY. PC-Programmable Signal Isolator/Converter with Display

MANUAL Surge Protectors

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur

SFY Functional Safety Frequency-to-DC Transmitter with Display

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

SITOP in the SIMATIC Design

SIY. Features. PC-Programmable Signal Isolator/Converter

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

BA414DF Fieldbus indicator Single variable

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Technical Data. General specifications. Rated operating distance s n 3 mm

Installing Fieldbus. Installing Fieldbus

STA SIL 2 and SIL 3 Capable Programmable Current/Voltage and RTD/Thermocouple Safety Trip Alarms

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

HES. Description. Industrial Internet of Things - HART Over Ethernet

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Distributed Intrinsically Safe Fieldbus Applications

DeltaV Bulk Power Supplies

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

3420 Fieldbus Interface Module (FIM) Contents

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

DeltaV Bulk Power Supplies

CompactBlock Guard I/O EtherNet/IP Safety Modules

Inductive sensor NI3-EG08K-Y1-H1341

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

Inductive sensor BI1.5-EG08-Y1-H1341

PAC BI-DP BIM and 8701-CA-BI Carrier

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

M-series DC to DC Power Supply

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Industrial Power Supplies

microblox I/O Modules w/ Bluetooth Wireless Technology Introduction to the microblox Module Family

VersaMax IP I/O Module

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

PI-EX-ME-2NAM/COC-24VDC

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Technical Datasheet #TDAXTC20 Thermocouple Scanner 20 Thermocouple Channels CAN, SAE J1939 with Electronic Assistant P/N: AXTC20 Description:

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

F11 Fieldbus Power Hub

Faults on the system Proximity switch connection technology:

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

IMC-101 Series Quick Installation Guide

Simple but elegant look and ease of installation make it ideal for various industrial applications.

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Temposonics. Magnetostrictive, Linear-Position Sensors. G-Series Embedded Redundant Model GTE Analog (Voltage/Current) Data Sheet

FOUNDATION. Product Overview. Foundation Fieldbus

SIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS

ZFM ZFM DIGITAL MASS FLOW METER

Industrial Power Supplies

Conveyor Belt Alignment Switches from IDEM

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

S-series Foundation Fieldbus I/O

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Velomitor* CT Velocity Transducer

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Model Number Structure

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

microncs Description Features MODBUS RTU Master and Distributed I/O System

S-series Sequence of Events Card

SITOP PSU8600 power supply system

PROFIBUS-PA Positioner Type 3785

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

FF Physical Layer Components

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Transcription:

July 2013 Description The TRUNKSAFE Fault-Tolerant Fieldbus System provides a cost-effective, yet highly reliable, strategy to maintain continuous communications between field devices and a host system in the event of any single point failure (such as any open single wire) on a FOUNDATION fieldbus H1 or PROFIBUS PA segment. Delivers High-Availability Fieldbus Segments Designed for important and plant-critical fieldbus segments, TRUNKSAFE utilizes two trunk cables (or legs ) for physical layer redundancy to ensure no single point of failure will shut down the network. Under normal operation, the fieldbus segment is terminated at each end of the segment at the TRUNKSAFE Redundant Power Conditioners. TRUNKSAFE maintains fieldbus communications throughout the entire segment until a fault (open- or short-circuit) is detected. Upon fault detection, the TRUNKSAFE Device Coupler initiates its automatic segment termination so that the healthy leg is properly terminated. This patented*, automatic system for fault detection and termination allows uninterrupted fieldbus communications throughout the segment (see Figure 1). The host is informed about the fault via a contact closure output. TRUNKSAFE is fully compliant with FOUNDATION fieldbus FF831-1 (the technical specification for fieldbus power supplies) and FF846-1 (the technical specification for device couplers). 2013 Moore Industries-International, Inc. 920156D Fault-Tolerant Protection Against All Physical Layer Faults One difficulty still remains with fieldbus technology: all segment communications and power integrity are vulnerable to a single broken twisted wire cable. Until now, the only ways to protect plantcritical segments were expensive duplication of an entire segment s hardware, complex software voting schemes and restricting the number of devices per segment. With TRUNKSAFE, critical process loops can use fieldbus technology without worrying about cable failures. This allows full access to advanced diagnostics and uninterrupted measurement and control communications that can be realized using fieldbus technology. * United States Patent Numbers 7,454,252 and 7,505,819 All product names are registered trademarks of their respective companies. TRUNKSAFE Fieldbus Device Couplers and Power Conditioners install on a DIN-style rail. Device couplers can be ordered in rugged field-mount enclosures with cable glands. Features Complete redundant fieldbus physical layer. TRUNKSAFE is comprised of a Host Interface, two redundant fieldbus DC Power Conditioners and a specially-engineered Device Coupler that, in combination, maintain continuous segment communications even in the event of a cable break (open- or short-circuit) or failures to a TRUNKSAFE Power Conditioner. Compatible with FOUNDATION Fieldbus H1 and PROFIBUS PA networks. Completely compliant with fieldbus physical layer standard IEC 61158-2; no modification is required to fieldbus devices or to DCS-level software. Advanced Fieldbus physical layer diagnostics. TRUNKSAFE Diagnostic Modules offer simple hardware-based alarm LEDs and voltage free relay for DC power status, segment noise, power conditioners and network status. Certifications Factory Mutual (cfmus) US/Canada File No. 3032513C Non-Incendive - Class I, Division 2, Groups A, B, C, D; T4A Ta=70 C ATEX Certificate No. MII13ATEX0002X II 3 G Ex na nc [ic] IIC T4 Ta: 40 C to +70 C IECEx Certificate No. FMG 08.0007X Ex na nc [nl] IIC T4 CE Conformant EMC Directive 2004/108/EC EN 61326 Page 1

Figure 1. TRUNKSAFE maintains continuous segment communications between field devices and a host system in the event of any single point failure, such as an open- or short-circuit. Two Trunk Cable B (less than 30m) Fieldbus Trunk Cable A (less than 30m) Legs T Termination is NOT ACTIVE TPS201-4 DCS Redundant H1 or PA Interface Moore Industries Host Interface Kit Available Host Interface Kits accommodate the specific architectures of host specific configurations. These provide a seamless connection to the redundant physical H1 layer without affecting host hardware or software. (See the TRUNKSAFE User s Manual for details.) T Termination is ACTIVE TPS201-4 Power Conditioner DIN Carrier + S - Auto-detects system and field cable failure and then prevents communications on that side of the trunk + S - SPM201 Surge Protection Module (optional) BREAK! Total cable length per segment can be up to 1,900m (6,233ft), with a maximum of 1,000m (3,280ft) trunk on one side Cable lengths on each side do not need to be balanced FDM252 On-board Diagnostics Module provides comprehensive fieldbus physical layer diagnostics Uninterrupted Fieldbus Segment Communications TPS202 Advanced Power Conditioner Module Up to 350mA of isolated, redundant and conditioned power per segment TS206 TRUNKSAFE Device Coupler + S + S LED ON indicates active trunk status TRUNK A TRUNK B + S + S + S + S + S + S FF/PA Devices Field Enclosure (optional) Auto-Termination is ACTIVE TRUNKSAFE s Automatic Segment Termination is initiated upon fault detection on either side of the trunk Page 2

Simple, Yet Secure, Redundancy The TRUNKSAFE Fault-tolerant Fieldbus System is comprised of three main sections: a Host Interface Kit (with Fieldbus Redundancy Adaptors), two fieldbus DC Power Conditioners, and a single field-based Device Coupler (Figure 1). TRUNKSAFE s major advantage is that no single point of failure will cause the loss of fieldbus communications with the host system. TRUNKSAFE s Host Interfaces are unique to each host system, since each supplier has their own method of supporting redundant H1 cards or a PA coupler. The TRUNKSAFE concept is to convert these single H1 or PA trunk outputs into two trunk outputs that will be carried all the way to the Device Coupler in the field. Typically this is done with Fieldbus Redundancy Adapters connected on the host H1 cards or terminal board (See the TRUNKSAFE User s Manual for details). Additional Fieldbus Redundancy Adapters (when needed) ensure that active modules can be replaced without shutting down H1 or PA communications. The resultant two trunk outputs begin the redundant H1 segment, and are then wired to separate TRUNKSAFE Power Conditioner DIN Carriers (TPS201). In most cases this is accomplished with a plug-to-plug cable connector carrying four segments. Each segment has two trunks, and each trunk is connected to a separate Fieldbus Power Conditioner DIN Carrier Board. Each Carrier Board supports four trunks with an individual Power Conditioning Module (TPS202) for each trunk. The segment has redundant Power Conditioner Modules (one on each DIN Carrier Board) providing conditioned power to the trunk and fieldbased Device Coupler. The Device Coupler receives power and communications from each trunk. In normal operation, integral fieldbus terminators are provided at each Power Conditioner Module. Completely compliant with IEC 61158-2, the system will support a total cable length including the redundant leg and spurs of up to 1,900 meters (6,233 feet). Reaction to Cable Fault Detection TRUNKSAFE provides industry-first secure communications for a fieldbus network. Advanced Redundant Power Conditioners Both of TRUNKSAFE s Power Conditioners continuously monitor its segment cable leg. In the event of a field cable (open-circuit, short-circuit or broken wire) or host failure, the Power Conditioner immediately detects, reports and isolates the faulty leg. System communications will continue over the remaining leg. Device Couplers with Fully-Automatic Segment Terminator The TRUNKSAFE Device Coupler simultaneously detects the absence of DC power on the incoming trunk as a cable fault on one leg, and activates its terminator. This maintains normal fieldbus communications on the healthy leg. Internal blocking circuitry prevents current flow out of the device coupler so that a trunk short-circuit on one side cannot affect the trunk on the other side. The TRUNKSAFE Device Coupler automatically resets when cable integrity is restored. This functionality allows TRUNKSAFE to maintain all fieldbus communication functions in spite of any single system fault, and provide for automatic reset once the faults are removed. TRUNKSAFE Advanced Fieldbus Power Conditioner The TRUNKSAFE Power Conditioner is composed of a TRUNKSAFE DIN Carrier (Model TPS201) populated with up to four TRUNKSAFE Advanced Power Conditioner Modules (Model TPS202). Each Power Conditioner provides up to 350mA of isolated and conditioned DC power for FOUNDATION fieldbus H1 or PROFIBUS PA segments. The system s power conditioner pairs are fully load-sharing in normal operation. Each also incorporates a hard-wired segment terminator that is always ON. Physical Layer Diagnostics The TRUNKSAFE system incorporates a diagnostics module which maintains overall system high-availability by giving advance notice of cable faults as well as potential failures (See Page 6 for additional information). TRUNKSAFE Fieldbus Device Coupler Available in 6- and 12-spur configurations, TS200 Device Couplers have designed in redundancy and feature: Automatic Segment Termination TRUNKSAFE delivers the unique advantage of being able to identify a open- or short-circuit, isolate the faulty leg, and automatically terminate the leg of the TRUNKSAFE system that continues operating normally. Short Circuit Protection TRUNKSAFE Device Couplers provide electronic and fully auto-resetting spur short-circuit protection that prevents segment failure caused by single device faults. Utilizing a FoldBack technique, any spur that attempts to draw more than 48mA is automatically switched off and not permitted any current flow until the fault is removed. This is a significant advantage over current-limiting designs on competing units which hold a fault permanently on the segment at a higher than normal current level. This often results in segment failure by overloading the segment power supply. With removal of the short, the TRUNKSAFE Device Coupler automatically reconnects the spur to the fieldbus segment. Diagnostic LEDs and hand-held connections Diagnostic LEDs positively indicate status of each incoming trunk, power status on each spur, spur short circuits and status of auto termination. The front panel features convenient connections for a fieldbus hand-held configurator (see Page 6). Page 3

Specifications TRUNKSAFE Advanced Fieldbus Power Conditioner Terminals Indicators TPS201-4 Power Conditioner DIN Carrier Number of Segments: 4 Supply Voltage: 19.2 to 32Vdc, reverse polarity protected Type: Removable terminals with screwclamp retaining screws Wire Size: Handles 0.8-2.5mm 2 /12-24AWG cable sizes TPS202 Power Conditioner Module Output Capacity: 350mA per segment; up to 25.5V (no load) Power Requirements: 13.5VA @350mA per segment Power Dissipation: 5.5W @350mA per segment Terminator: 100 ohms/1microfarad per segment DC/DC Isolation: 500Vdc (segment to power supply) LED (Power): GREEN, normal; ORANGE, Output Voltage <18V LED (Short): GREEN, normal; RED, Cable Short LED (Open): GREEN, normal; RED, Cable Open LED Indicators Alarm Relay Output FDM252 Fieldbus Diagnostics Module Power Dissipation: 0.5W maximum LED Type: GREEN, Normal; RED, Fault LED A: DC A Input Voltage Low (<18V) LED B: DC B Input Voltage Low (<18V) LED 1: Segment #1 Noise High (>75mV p/p) LED 2: Segment #2 Noise High (>75mV p/p) LED 3: Segment #3 Noise High (>75mV p/p) LED 4: Segment #4 Noise High (>75mV p/p) Type: Relay (failsafe, open on alarm) Contact Rating: 5A@250Vac 50/60Hz or 24Vdc, non-inductive load Ambient Conditions (All Components and Options) SPM201 Surge Protection Module Complies with: -IEC 61158-2, for 31.25kB/s and testing according to -IEC 61643-21 Maximum Surge Current Isn: 20kA (8/20μsec) Nominal Discharge Current Isn: 3kA(8/20μsec) Nominal Rated Current In: 650mA Maximum Continuous Operating Voltage (MCOV): 35V Peak Common Mode: 230V Limiting Voltage Vlim: 50V@3kA (8/20μsec) Nominal Voltage Vn: 32V Line Attenuation: Rs: 1 ohm capacitance:1nf IP Rating: IP20 Operating Range: 20 C to +60 C ( 4 F to +140 F) Storage Range: 40 C to +85 C ( 40 F to +185 F Relative Humidity: 0-95%, non-condensing RFI/EMI Immunity: 10V/m@80-1000MHz, 1kHz AM when tested according to IEC61326 TRUNKSAFE Fieldbus Device Coupler (TS200) Communications FOUNDATION Fieldbus H1 or PROFIBUS PA Maximum Quiescent Current: TS206: 13.5mA TS20W: 25mA Maximum Spur Output Current: I Slim =48mA Spur Short Circuit Load: I Ssc 2mA (typical)/6ma max. Spur Voltage Drop: 0.5V@20mA spur current (typical), 1V maximum Maximum Spur Voltage: 24V max. no load LED Indicators Terminals Enclosures (Optional) Trunk: GREEN (Active); OFF (Inactive) Spur: GREEN (Normal); RED (Fault) Auto-Terminator: YELLOW (Terminator On); OFF (Terminator Off) Type: Removable terminals with screwclamp retaining screws Wire Size: Handles sizes between 0.8-2.5mm 2 /12-24AWG Type: Aluminum IP66; Stainless Steel 316 IP66; GRP (Glass Reinforced Polyester) IP66 Cable Gland (Device Couplers with Enclosures) Ambient Conditions Type: Armored/ Unarmored Material: Nickel-plated brass Operating Range: 40 C to +70 C ( 40 F to +158 F) Storage Range: 40 C to +85 C ( 40 F to +185 F) Relative Humidity: 0-95%, non-condensing RFI/EMI Immunity: 10V/m@80-1000MHz, 1kHz AM when tested according to IEC61326 Page 4

Ordering Information TRUNKSAFE Advanced Fieldbus Power Conditioner and Associated Accessories Description TRUNKSAFE Advanced Power Conditioner DIN Carrier (Handles up to 4 TPS202 Advanced Power Conditioners) TRUNKSAFE Advanced Power Conditioner Modules (Specify up to 4 per TPS201-4 DIN Carrier) TRUNKSAFE Fieldbus Diagnostics Module (One module per TPS201-4 DIN Carrier) TRUNKSAFE Surge Protection Module (Optional, one per active segment requiring protection) Model Number TPS201-4 TPS202 FDM252 SPM201 Unit TS2 TRUNKSAFE Fault-Tolerant Fieldbus System Mounting/ Enclosure Type 0 DIN-Rail Mount (No enclosure; for installation in another manufacturer s enclosure; IP54 protection is recommended) TRUNKSAFE Fieldbus Device Coupler Number of Spurs Gland Connector Type Gland Entry Size Certification 6 Fieldbus Spurs W 12 Fieldbus Spurs Not Applicable -DIN (No cable glands) Universal DIN-style enclosure mounts on 32mm (EN50035) G-type and 35mm (EN50022) Top Hat DIN-rails -ATEX For use in Zone 2 with [ic] spurs 5 Standard Aluminum, Solid Cover, IP66 Enclosure 6 Standard Aluminum, Clear Cover, IP66 Enclosure 4 Stainless Steel 316, IP66 Enclosure with E-Z vertically removable lid and bottom entry cable gland plate 3 GRP (Glass Reinforced Polyester), IP66 Enclosure 6 Fieldbus Spurs W 12 Fieldbus Spurs 6 Fieldbus Spurs -A Unarmored Cable Glands (standard) -B Armored Cable Glands -C Compound Seal Cable Glands -D No Cable Glands -E M12 Turck Eurofast Sockets -F 7/8-in. Turck Minifast Sockets NOTES: 1. Gland/connector selection is for all entry ports. 2. Choices -E and -F have male sockets for Trunk In and female sockets for Trunk Out and Spurs. 3. Weatherproof seals are provided for all glands, but not sockets. 4. Compound seal glands are epoxy filled on installation and prevent gas transmission into enclosures; no seal pot required from Division 1 to Division 2. When ordering, specify: Unit Mounting or Enclosure Type Number of Spurs -Gland/Connector Type -Gland Entry Size Model number example: TS256-DIN-ATEX (6-Spur Device Coupler in Aluminum Enclosure with Cable Glands for Unarmored Cable with ATEX Certification) Typical TRUNKSAFE Bill of Materials (for single segment TRUNKSAFE network): GLAND ENTRY SIZE FOR: -O (standard) Unarmored Cable (7.5-11.9mm O.D.); Armored Cable (9.5-16.0mm O.D.) -S Unarmored Cable (3.0-8.0mm O.D.); Armored cable (5.5-12.0mm O.D.) 1 ea. Host Interface Kit Host Interface Kit (See the TRUNKSAFE User s Manual for Details) 2 ea. TPS201-4 4-Position TRUNKSAFE Advanced Power Conditioner DIN Carrier 2 ea. TPS202 TRUNKSAFE Power Conditioner Module 2 ea. FDM252 TRUNKSAFE Fieldbus Diagnostics Module 2 ea. SPM201 TRUNKSAFE Surge Protection Module 1 ea. TS256-A-0 6-Spur TRUNKSAFE Device Coupler in Aluminum Enclosure with Cable Glands for Unarmored Cable Page 5

Intelligent Physical Layer Diagnostics The TRUNKSAFE Redundant Fieldbus System delivers comprehensive diagnostic capabilities at every level. Power Supply Diagnostics LEDs on the TRUNKSAFE Power Conditioner Modules alert users to potential problems: Host or field cable open-circuit Host and field cable short-circuit High field current (>350mA) Low Power Conditioner output voltage (<18V) The TRUNKSAFE Diagnostic Module provides additional information on vital parameters influencing the physical layer. A volt-free contact closure can be wired as a general alarm, with individual LEDs on the Diagnostic Module reporting the following faults: DC Input Voltage #1 Low (<18V) or Loss of Input Supply DC Input Voltage #2 Low (<18V) or Loss of Input Supply Segment #1 Noise High (>75mVpp) Segment #2 Noise High (>75mVpp) Segment #3 Noise High (>75mVpp) Segment #4 Noise High (>75mVpp) NOTE: Advanced Diagnostics Advanced physical layer diagnostic modules with communications to a host are available from several vendors. We suggest selective use of this capability tied to control or critical segments. Third-party DINrail mounted Advanced Diagnostic Modules can easily be attached to any MooreHawke segment. Consult the factory for details. Device Coupler Diagnostics LEDs on the TRUNKSAFE s Device Couplers provide instant indication of: Power status each TRUNK Power status per SPUR Short-circuit status per SPUR Auto-termination ON/OFF NOTE: The TRUNKSAFE system provides complete fault tolerant segment communications independent of the TRUNKSAFE Diagnostics Module. However, all advanced diagnostics and all alarms require the Diagnostics Module to be specified with the system. Fieldbus Redundancy Adaptor A TRUNKSAFE host-specific Fieldbus Redundancy Adaptor installs between the H1/PA interface card(s) and the TRUNKSAFE Power Conditioner DIN Carrier Board, and routes the fieldbus signal to both trunks of the TRUNKSAFE network. The Fieldbus Redundancy Adaptor and Interface Adaptor (if necessary) has no effect on the operation or performance of the H1/PA cards, and is typically mounted in close proximity to the H1/PA card or module. TRUNKSAFE Fieldbus Host Interface Kits are available to accommodate the architectures of the major host manufacturers including ABB, Emerson Process Management, Honeywell, Invensys, Siemens and Yokogawa. A generic redundancy adaptor is also available to accommodate other host suppliers or when a single H1 Card or PA Coupler is used in a host system. Surge Protection Module The SPM201 Surge Protection Module prevents surges and over voltage spikes occurring directly on the main trunk from causing damage to the TRUNK- SAFE Power Conditioner Modules, as well as the host system. Inserted onto the field side pluggable terminal position, the SPM201 is fitted with a combination of solid state electronics and a gas discharge tube to withstand a surge of up to 20kA. It diverts surges to a safe earth connection, with no effect on the performance of the TRUNKSAFE Power Conditioner. All TRUNKSAFE Power Conditioner Carriers (TPS201-4) fitted with SPM201 Modules must have a secure low-impedance (<0.1 ohm) connection to the main local ground. Figure 2. SPM201 schematic. (+) TO FIELD ( ) (s) a s b Gas Discharge Tube a s Gas Discharge Tube TO POWER CONDITIONER Page 6

Figure 3. TPS201/202 Advanced Power Conditioner with DIN-Rail Mounting Installation Dimensions. Figure 4. TS200 Device Coupler DIN-Rail Mounting Installation Dimensions (Base Unit). 216mm (8.50 in) TOP VIEW 127mm (5.00 in) 6-Spur (Shown) 204mm (8.05 in) 12-Spur TOP VIEW TPS200 114mm (4.50 in) 82mm (3.23 in) 121mm (4.77 in) SIDE VIEW (Shown with SPM Surge Protection Module Installed) SIDE VIEW 51mm (1.99 in) Figure 5. Standard Aluminum Enclosure Installation Dimensions for 6-Spur (TS256) and 12-Spur (TS25W) Models. 156mm (6.14 in) 175mm (6.89 in) 322mm (12.68 in) 293mm (11.54 in) 274mm (10.79 in) GROUND STUD SCREW #10-32 DIA. 4.8mm (0.190 in) 367mm (14.45 in) 107mm (4.21 in) Page 7

Model No : Serial No : Tag No : Model No : Serial No : Tag No : TS Series Figure 6. Stainless Steel 316 with E-Z Vertically Removable Lid and Bottom Entry Cable Gland Plate 12-Spur Models (TS24W). 35mm (1.50 in) MIN CLEARANCE FOR LID REMOVAL 319mm (12.56 in) FOR PLASTIC ENCLOSURES: CLEAN ONLY WITH DAMP CLOTH TRUNKGUARD Series 200 Device Coupler Moore Industries-International North Hills CA, USA 260mm (10.24 in) Padlock fixing GROUND STUD M10 DIA. 10mm (0.394 in) 183mm (7.20 in) REMOVABLE GLAND PLATE 135mm x 175mm (5.31 in x 6.89 in) PRE-DRILLED M20 ENTRIES 2x PLATES 224mm (8.82 in) 248mm (9.76 in) Figure 7. GRP (Glass Reinforced Polyester) Enclosure Installation Dimensions for 6-Spur (TS236) Models. Figure 8. TS2XX-DIN with -ATEX option TOP VIEW 127mm (5.00 in) 6-Spur (Shown) 204mm (8.05 in) 12-Spur FOR PLASTIC ENCLOSURES: CLEAN ONLY WITH DAMP CLOTH TRUNKSAFE Series 200 Device Coupler Moore Industries-International North Hills CA, USA 244mm (9.60 in) 82mm (3.23 in) 260mm (10.24 in) Shown with Unarmored Cable Glands 140mm (5.51 in) 160mm (6.30 in) 55mm (2.17 in) 105mm (4.13 in) SIDE VIEW 51mm (1.99 in) 73mm (2.90 in) United States info@miinet.com Tel: (818) 894-7111 FAX: (818) 891-2816 Australia sales@mooreind.com.au Tel: (02) 8536-7200 FAX: (02) 9525-7296 www.miinet.com Belgium info@mooreind.be Tel: 03/448.10.18 FAX: 03/440.17.97 The Netherlands sales@mooreind.nl Tel: (0)344-617971 FAX: (0)344-615920 China sales@mooreind.sh.cn Tel: 86-21-62491499 FAX: 86-21-62490635 United Kingdom sales@mooreind.com Tel: 01293 514488 FAX: 01293 536852 Page 8 Specifications and information subject to change without notice.