MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

Similar documents
MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

Spectra RMS Circuit Breakers with microentelliguard Trip Units

SACE Emax 2 Specification guide

www. ElectricalPartManuals. com Micro Versa Trip Plus and Micro Versa Trip PM Trip Units User's Manual

Featuring Spectra RMS Breakers

MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SURE TRIP RETRO KITS With RMS CURRENT MEASUREMENT

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

GE Industrial Solutions. Aftermarket Solutions. Product Portfolio

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

General Purpose Control Components Welcome to the Control Catalog!

SECTION SWITCHBOARDS

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

URC Utility Relay Company

IPS INTELLIGENT PUMP STARTER

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Electronic Submeter with Advanced WiFi Ethernet Capability

EntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability.

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

MODULAR CIRCUIT MONITORING SYSTEM

SECTION ( ) LIGHTING CONTROL PANELBOARD

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

PDI Modular Compact Remote Power Panel

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

920 Remote Control (RC) Switches

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

GE Power Management. MMII Intelligent MCC Controller

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Series 3000 User Manual and Product Features

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.

Smartstart Control Module

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

CDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Quick Start Installation Guide

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

DEH-433. Warnings, Cautions, and Notes as used in this publication

GE Entellisys Low Voltage Switchgear. System Test Kit. User Manual

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

GE Multilin 350 Feeder Protection Relay Specifications

160 AA02SF1 AF DS-D17

TR200 DRIVE STANDARD FEATURES

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

SENTRON 3VL Molded Case Circuit Breakers

Solid-State Switching Devices

Strand Lighting Specification

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

VIP 40/45 VIP 400/410

Crane Control Contactors and Relays

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

ASCO 920 Remote Control (RC) Switches

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

STANDARD SUBMITTAL PACKAGE

SECTION DISCONNECT SWITCHES

Series 2400 Paralleling Switchgear

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

Section 4 Ground-Fault Protection Devices

E 1. SPECOM - Network analyser. Content. E.2 Description. E.3 Specom C - Technical data. E.4 Specom M - Technical data. E.5 Data communication

60103 Circuit Breaker

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

AIR COOLED MODULAR RECTIFIER

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Tmax molded case circuit breakers Specification guide

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

UW Purchase Specification Section

USER MANUAL 2012 V1.1

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

PQM - Power Quality Monitoring

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

NW08 to NW63 fixed circuit breakers Circuit breakers

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

PGC 4000v2 POWER GENERATION CONTROLLER

ES Energy Saver Product Ranges 90Amp 6000Amp

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Transcription:

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure safe, reliable operation with ANSI C37.59 tested kits Improve system protection and increase productivity by eliminating nuisance tripping Integrate mixed switchgear with kits available for Westinghouse, I-T-E & GE low voltage power circuit breakers Allis Chalmers LA1600 Blue with MicroVersaTrip Plus trip unit upgrade The easy, cost-effective way to increase reliability, enhance performance and extend the life of your existing equipment. GE Industrial Systems

Now upgrade your low-voltage power circuit breakers with electronic trip unit technology Normal wear and tear of aging electro-mechanical trip devices on low-voltage power circuit breakers increases susceptibility to loss of calibration that can subsequently jeopardize electrical power system coordination, protection and reliability. GE has channeled its decades of circuit breaker trip system experience into the development of the MicroVersaTrip Plus and MicroVersaTrip PM conversion kits for GE, Westinghouse, I-T-E, and Allis Chalmers low-voltage power circuit breakers. ANSI C37.59 design verification tested to ensure safe, reliable operation, these kits are designed to extend the life of your mechanically sound breakers and Eliminate costly downtime due to nuisance tripping Improve electrical power system coordination and protection Permit easy upgrades to communicating Power Management Control Systems (PMCS) Provide safe, convenient closed-door local metering via the optional Remote Display Standard and optional features Standard MicroVersaTrip Plus and MicroVersaTrip PM adjustable trip unit functions include: Current setting Long time Long time delay Instantaneous Local fault trip indicators Optional features include: Short time Short time delay with or without I 2 t Ground fault Ground fault delay with or without I 2 t Switchable instantaneous/short time and ground fault (off) (not UL approved for a listed breaker) Full function metering (MicroVersaTrip PM) Protective relaying (MicroVersaTrip PM) Industry standard open communications capability (MicroVersaTrip PM) Remote display module Trip unit test set (TVRMS2) MicroVersaTrip Plus conversion kit features Superior trip unit accuracy and system protection is achieved by taking 64 samples per 60 Hz cycle. This provides true RMS sensing of electrical distribution systems that include AC and DC variable speed drives, rectifiers, induction heaters and other loads that contribute to non-sinusoidal (high-harmonic) current wave forms. Easy system coordination with maximum flexibility is obtained using multiple trip setpoints, time-delay bands and ramp time functions. Visual pickup and trip indicators for overload, short circuit and ground fault, display type of fault, phase and current magnitude when applicable Predictive and preventative maintenance decisions are made easily using the trip operations counter that stores the total number of Long time, Short time, Instantaneous and Ground Fault trips. Continuously self-testing microprocessor eliminates trip unit bench-testing Non-volatile memory High-visibility LCD display Cold setup capability and target viewing from long-life (5-year) field- replaceable lithium battery external power not required Positive setpoint recognition, values flash until entered and accepted Easy access 5-button keypad with positive action Phase selectable ammeter (±2% accuracy) Sealable, clear Lexan protective cover over LCD display and Enter key prevents unauthorized access to protective functions and target reset Interchangeable rating plug Quick-disconnect trip unit design speeds installation and allows for easy upgrade to MicroVersaTrip PM units with communications capability, full-function metering and optional protective relaying functions

Easy conversion kit and rating plug catalog number selection Catalog Number Structure ASL6B C 3 F 06 02 PM Breaker LA = ASL25 2 LA-25A = ASL2A 2 LA-600(Blue) = ASL6B 4,9 LAF-600(Blue) = ASL6B 4,9,10 LA-600(Gold) = ASL6G 5,9 LAF-600(Gold) = ASL6G 5,9,10 LA-50(800A) = ASL58 2,6 LA-800 = ASL80 5,9 LAF-800 = ASL80 5,9,10 RL-800 = ASR80 2 RLX-800 = ASR80 2 RLE-800 = ASR80 2 LA-50(1600A) = ASL51 2,7 LA-50(1600A) = ASL52 2,8 LA-1600(Blue) = ASL1B 4,9 LAF-1600(Blue)= ASL1B 4,9,10 LA-1600(Gold) = ASL1G 5,9 LAF-1600(Gold)= ASL1G 5,9,10 RL-1600 = ASR16 2 RLX-1600 = ASR16 2 RLE-1600 = ASR16 2 RL-2000 = ASR0 2 LA-75 = ASL75 2 LA-3000 = ASL30 2,9 LA-3200(Blue) = ASL3B 2,4,9 LA-3200(Gold) = ASL3G 2,5,9 RL-3200 = ASR32 2 LA-4000(Blue) = ASL4B 2,4,9 LA-4000(Gold) = ASL4G 2,5,9 RL-4000 = ASR40 2 Model C = Generation Wiring 3 Wire = 3 4 Wire 1 = 4 Definitions: Blue = Blue-Gray color version breaker with plastic escutcheon. Gold = Gold color version breaker with metal escutcheon. Sensor Type F = Fixed CTs Sensor Rating3 150A = 01 225A = 02 400A = 04 600A = 06 800A = 08 1600A = 16 2000A = 20 3000A = 30 3200A = 32 4000A = 40 Sensor Rating Selection Frame Breaker Catalog Numbers Sensors 225 Sensor Rating 150A not presently available. 225A 600 LA-25, LA-25A 225A LA-600, LAF-600 600A LA-50 (800A Version) 150A 800 LA-800, LAF-800 400A RL-800, RLE-800, RLX-800 800A 1600 LA-50 (1600A Version), LA-1600, LAF-1600 800A RL-1600, RLE-1600, RLX-1600 1600A 2000 RL-2000 2000A 3000 LA-75, LA-3000 3000A 3200 LA-3200, RL-3200 3200A 4000 LA-4000, RL-4000 4000A Trip Functions LI = 02 LIG = 03 LSI = 04 LSIG = 05 LS = 06 LSG = 07 LSIGX = 08 Options Blank = Plus M = Metering & Communication PM = Metering, Communication & Protective Relaying Trip Unit Functions LI Long Time & Instantaneous LIG Long Time, Instantaneous & Ground Fault LSI Long Time, Short Time & Instantaneous LSIG Long Time, Short Time, Instantaneous & Ground Fault LS Long Time & Short Time LSG Long Time, Short Time & Ground Fault LSIGX Long Time, Short Time/Inst. & Switchable Ground Fault (off), not approved for a UL listed breaker 1. Only applicable to trip units with ground fault. 2. Contact factory for availability. 3. Order rating plug separately, see chart on facing page. 4. Only applicable for Blue-Gray color version breakers. 5. Only applicable for Gold color version breakers. 6. 800-amp version of the LA-50 breaker. 7. Only applicable for 1600 -amp, 6-pole primary disconnect version of the LA-50 breaker. 8. Only applicable for 1600-amp, 12-pole primary disconnect version of the LA-50 breaker. 9. Applicable to both A and B version breakers. 10. Applicable to both nameplated versions of integral fused breakers. (i.e. LA-600F and LAF-600)

Easy conversion kit and rating plug catalog number selection Rating Plugs (Rating plugs priced and ordered separately) Frame Size Sensor Rating Current Rating Current Range Rating Plug (Amps) (Amps) (Amps) (Amps) Catalog No. 60 30-66 TR1B60 80 40-88 TR1B80 225 150 100 50-110 TR1B100 125 63-138 TR1B125 150 75-165 TR1B150 225 100 50-110 TR225B100 or 225 150 75-165 TR225B150 600 225 113-248 TR225B225 300 150-330 TR6B300 400 200-440 TR6B400 600 600 450 225-495 TR6B450 500 250-550 TR6B500 600 300-660 TR6B600 60 30-66 TR1B60 80 40-88 TR1B80 800 150 100 50-110 TR1B100 125 63-138 TR1B125 150 75-165 TR1B150 150 75-165 TR4B150 200 100-220 TR4B200 800 400 225 113-248 TR4B225 250 125-275 TR4B250 300 150-330 TR4B300 400 200-440 TR4B400 300 150-330 TR8B300 400 200-440 TR8B400 800 450 225-495 TR8B450 or 800 500 250-550 TR8B500 1600 600 300-660 TR8B600 700 350-770 TR8B700 800 400-880 TR8B800 Frame Size Sensor Rating Current Rating Current Range Rating Plug (Amps) (Amps) (Amps) (Amps) Catalog No. 600 300-660 TR16B600 800 400-880 TR16B800 1600 1600 1000 500-1100 TR16B1000 1100 550-1210 TR16B1100 1200 600-1320 TR16B1200 1600 800-1760 TR16B1600 800 400-880 TR20B800 1000 500-1100 TR20B1000 2000 2000 1200 600-1320 TR20B1200 1500 750-1650 TR20B1500 1600 800-1760 TR20B1600 2000 1000-2200 TR20B2000 1200 600-1320 TR30B1200 1600 800-1760 TR30B1600 3000 3000 2000 1000-2200 TR30B2000 2500 1250-2750 TR30B2500 3000 1500-3300 TR30B3000 1200 600-1320 TR32B1200 3200 3200 1600 800-1760 TR32B1600 2400 1200-2640 TR32B2400 3200 1600-3520 TR32B3200 1600 800-1760 TR40B1600 2000 1000-2200 TR40B2000 4000 4000 2500 1250-2750 TR40B2500 3000 1500-3300 TR40B3000 3600 1800-3960 TR40B3600 4000 2000-4400 TR40B4000 For details and ordering information, contact your local ED&C sales office, or visit us at www.ge.com/industrialsystems

MicroVersaTrip PM conversion kits Power management made easy The enhanced MicroVersaTrip PM trip unit adds power management system capability including advanced metering and protective relaying to the basic functions of the MicroVersaTrip Plus. When connected to GE s Power Management Control System (PMCS), it gives you the power to increase productivity and reduce costs while meeting all your electrical system monitoring needs. You can easily: Use standard graphics packages that allow the end user to view custom one-lines for metering and trending screens Analyze energy consumption and power factor trends to minimize utility demand and PF charges or provide low-cost allocations Collect precise sequences of alarm and event information to speed diagnosis and minimize downtime Use alarm and event logs to assist with preventive maintenance interval planning Analyze system harmonics (with data input from PQM, EPM 3710, EPM 3720 or EPM 7700 meters) Communicate with other devices, including Spectra Series molded case and Power Break insulated case breakers, full-function electronic power meters, programmable logic controllers, GE Multilin protective relays and smart motor starters Utilize GE s Power Management Control System and its industry standard Modbus RTU, Ethernet TCP/IP open protocols Additional features Full-function metering* including current (Amps, kamps) voltage (Ph-Ph, Ph-N) energy (kwh, MWh, GWh) real power (kw, MW) total power (kva, MVA) frequency (Hz) demand & peak demand (avg. kw, MW) Optional protective relaying* functions include undervoltage overvoltage voltage unbalance current unbalance power reversal power direction setup * Requires potential transformer and voltage conditioner inputs (not included in kits auxiliary panels sold separately) Optional Remote Display Provides safe, convenient closed-door access to breaker metering, status and setup functions Available for use with either MicroVersaTrip Plus or MicroVersaTrip PM trip units Rugged NEMA Type 1 enclosure with LCD display and keypad Mounts easily on outside of breaker compartment door Sealable, clear Lexan protective cover over display and Enter key prohibits unauthorized trip setting changes Connects to breaker trip unit via tough non-flammable, non-toxic 20-pin plug-in cable for fast installation Breaker trip unit operates independently if cable is disconnected

Everything you need in one package GE s MicroVersaTrip Plus and MicroVersaTrip PM kits are shipped complete with detailed installation instructions and everything needed for fast and easy trip unit conversions. All kits come complete with: Digital solid-state trip unit with quick disconnect Direct-acting flux shifter with automatic reset Epoxy encapsulated high-accuracy current transformers Specially designed mounting hardware and wire harnesses with communications cable for each breaker frame Detailed instruction manual Interchangeable rating plug (order separately) For details on other MicroVersaTrip Plus and MicroVersaTrip PM conversion kits, ask your ED&C sales engineer for these publications: DET-067B MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for I-T-E Power Circuit Breakers DET-093B MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers DET-066B MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for GE Power Circuit Breakers DEE-019 GE POWER LEADER Product Information DEP-041 MicroVersaTrip Plus & MicroVersaTrip PM Remote Display DEP-056A PMCS Auxiliary Panel Components - Pricing & Selection Guide GEP-1100 GE Buylog (Reference for Power Management Components) DET-226 1198 BL General Electric Company 41 Woodford Avenue, Plainville, CT 06062 www.ge.com/edc 1998 General Electric Company GE Industrial Systems