YASKAWA AC Drive J1000

Similar documents
YASKAWA AC Drive-J1000

YASKAWA AC Drive-J1000

YASKAWA AC Drive J1000

YASKAWA AC Drive J1000

V1000 Series AC Drive

YASKAWA AC Drive J1000

YASKAWA AC Drive-J1000 Compact V/f Control Drive Technical Manual

Analog Monitor Installation Manual

Analog Input Installation Manual

YASKAWA AC Drive - Z1000

YASKAWA AC Drive P1000

YASKAWA AC Drive J1000

YASKAWA AC Drive-1000 Series Option Operator Mounting Kit NEMA Type 4X, IP66 Installation Manual Model No.: UUX or UUX000527

YASKAWA AC Drive P1000

iqpump1000 AC Drive Intelligent Pump Controller Installation & Start-Up Guide

Installation, Operation and Maintenance Manual

YASKAWA AC Drive GA700

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

YASKAWA AC Drive GA700

MDM 011-Z1 Regen Resistor

YASKAWA AC Drive Z1000

YASKAWA AC Drive-A1000

YASKAWA AC Drive J1000

Siemens Industrial s

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

EQ5 SERIES Quick Start Guide for Constant Torque Applications

U1000 Industrial MATRIX Drive

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Installation & Technical Manual

YASKAWA AC Drive 1000-Series Option EtherNet/IP. Technical Manual

iqpump1000 AC Drive Intelligent Pump Controller

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

1000A AC Elevator Drive Quick Start Guide

YASKAWA AC Drive V1000

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

EtherNet/IP. EtherNet/IP. Installation Manual. YASKAWA AC Drive Option. Type: SI-EN3

Installation Manual. YASKAWA AC Drive-V1000 Option EtherNet/IP. Type SI-EN3/V

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

SMVector Additional I/O Module Installation and Operation Manual

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

YASKAWA AC Drive Option EtherNet/IP. Technical Manual

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

YASKAWA AC Drive-V1000 Option PROFIBUS-DP. Technical Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Inverter (VFD) Manual

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

J1000 QUICK START GUIDE

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT

E7 Drive User Manual. Document Number: TM.E7.01

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

YASKAWA AC Drive-J1000 Option. RS-232C Interface. Technical Manual Type SI-232/J, SI-232/JC RS-232C SI-232/J, SI-232/JC J1000

PROFIBUS-DP. Installation Manual. YASKAWA AC Drive Option PROFIBUS-DP

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

FR-A8AR INSTRUCTION MANUAL

Resolver to Digital Expansion Board

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ELV12 Series. Instruction Manual

Table of Contents Product Overview Before using the product Installation Procedure... 5

Installation Manual Type AO-A3

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

Model Number Structure

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

2 YASKAWA ELECTRIC SIEP C A V1000 Option Modbus TCP/IP Technical Manual

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

GV3000/SE AC Drive 1-20 HP, 230V AC

Tempco Instruction Manual

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Differential Liquid/Gas Pressure Transmitter

Ethernet/IP Single and Dual-Port

GV3000/SE AC Drive Hardware Reference, Installation, and Troubleshooting VAC Version 6.04

YASKAWA AC Drive Option PROFIBUS-DP. Technical Manual

1-36V, 0-3A DC Power Supply

Installation Instructions

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

7032 Digital-Analog Multimeter

YASKAWA AC Drive 1000-Series Option EtherNet/IP. Technical Manual

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

CUS150M1 Instruction Manual

2012 YASKAWA ELECTRIC CORPORATION

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model VT120 Fast Timing Preamplifier Operating and Service Manual

E7 Drive User Manual. Document Number: TM.E7.01

Transcription:

YASKAWA AC Drive J1000 Compact V/f Control Drive Installation & Start-Up Manual Type: CIMR-JA, CIMR-JT Models: 200 V Class, Three-Phase Input: 0.1 to 5.5 kw 200 V Class, Single-Phase Input: 0.1 to 2.2 kw 400 V Class, Three-Phase Input: 0.2 to 5.5 kw To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. Receiving 1 MANUAL NO. TOEP C710606 25B Mechanical Installation Electrical Installation Start-Up Programming & Operation Troubleshooting Periodic Inspection & Maintenance Peripheral Devices & Options Specifications Parameter List Standards Compliance 2 3 4 5 6 7 A B C

This Page Intentionally Blank Copyright 2008 YASKAWA ELECTRIC CORPORATION. All rights reserved. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. 2 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

Table of Contents i. PREFACE & GENERAL SAFETY...9 i.1 Preface... 10 Applicable Documentation...10 Symbols...10 Terms and Abbreviations...11 i.2 General Safety... 12 Supplemental Safety Information...12 Safety Messages...13 Drive Label Warnings...15 Warranty Information...16 Quick Reference...18 1. RECEIVING...19 1.1 Section Safety... 20 1.2 Model Number and Nameplate Check... 21 Nameplate...21 1.3 Drive Models... 24 1.4 Component Names... 25 IP20/Open-Chassis...25 Front Views...27 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 3

Table of Contents 2. MECHANICAL INSTALLATION... 29 2.1 Section Safety... 30 2.2 Mechanical Installation... 33 Installation Environment...33 Installation Orientation and Spacing...34 Removing and Attaching the Protective Covers...35 Exterior and Mounting Dimensions...35 3. ELECTRICAL INSTALLATION... 39 3.1 Section Safety... 40 3.2 Standard Connection Diagram... 43 3.3 Main Circuit Connection Diagram... 46 Single-Phase 200 V Class (CIMR-JoBA0001 ~ 0010)...46 Three-Phase 200 V Class (CIMR-Jo2A0001 ~ 0020); Three-Phase 400 V Class (CIMR-Jo4A0001 ~ 0011)...46 3.4 Terminal Block Configuration... 47 3.5 Protective Covers... 48 IP20/Open-Chassis Cover Removal and Installation...48 3.6 Main Circuit Wiring... 50 Main Circuit Terminal Functions...50 Wire Gauges and Tightening Torque...50 Main Circuit Terminal Power Supply and Motor Wiring...52 3.7 Control Circuit Wiring... 54 Control Circuit Terminal Block Functions...55 Terminal Configuration...56 Wiring Procedure...57 3.8 I/O Connections... 60 Sinking/Sourcing Mode Switch...60 3.9 Main Frequency Reference... 63 DIP Switch S1 Analog Input Signal Selection...63 3.10 Braking Resistor... 65 Installation...65 3.11 Interlocking with Connected Machinery... 67 4 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

Table of Contents Drive Ready Signal...67 4. START-UP PROGRAMMING & OPERATION... 69 4.1 Section Safety... 70 4.2 Using the Digital LED Operator... 73 Keys, Displays, and LEDs...73 Digital Text Display...74 LED Screen Displays...75 LO/RE LED and RUN LED Indications...75 Menu Structure for Digital LED Operator...77 4.3 The Drive and Programming Modes... 78 Navigating the Drive and Programming Modes...78 Changing Parameter Settings or Values...82 Verifying Parameter Changes: Verify Menu...83 Switching Between LOCAL and REMOTE...84 Parameters Available in the Setup Group...85 4.4 Start-up Flowcharts... 86 Flowchart: Basic Start-up and Motor Tuning...86 4.5 Basic Operation... 87 Initialize Parameter Values: A1-03...87 Frequency Reference Source: b1-01...87 Run Command Input Selection: b1-02...89 Stopping Method Selection: b1-03...91 Acceleration/Deceleration: C1-01 to C1-04...92 Drive Duty Mode and Carrier Frequency Selection: C6-01 and C6-02...93 Multi-Step Speed Operation (4-Step Speed)... 96 Drive Input Voltage Setting: E1-01...99 V/f Pattern Settings: E1-04 to E1-10... 100 Motor Parameters: E2-01 to E2-03... 103 Digital Output: H2-01... 103 Analog Outputs: H4-01 to H4-03... 104 Motor Protection: L1-01 and L1-02... 105 Notes on Controlling the Brake for the Hoist Application... 108 Drive Status Monitors: U1-01 to U4-13... 109 4.6 Powering Up the Drive...111 Powering Up the Drive and Operation Status Display... 111 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 5

Table of Contents V/f Pattern Setting... 111 4.7 No-Load Operation Test Run...113 No-Load Operation Test Run... 113 4.8 Test Run with Load Connected...115 Test Run with the Load Connected... 115 4.9 Verifying and Backing Up Parameter Settings...116 Parameter Access Level: A1-01... 116 Password Settings: A1-04, A1-05... 116 5. TROUBLESHOOTING... 117 5.1 Section Safety...118 5.2 Motor Performance Fine Tuning...121 Parameters for Tuning the Drive... 121 Motor Hunting and Oscillation Control Parameters... 121 5.3 Drive Alarms, Faults, and Errors...123 Types of Alarms, Faults, and Errors... 123 Alarm and Error Displays... 124 5.4 Fault Detection...126 Fault Displays, Causes, and Possible Solutions... 126 5.5 Alarm Detection...134 Alarm Codes, Causes, and Possible Solutions... 134 5.6 Operator Programming Errors...139 ope Codes, Causes, and Possible Solutions... 139 5.7 Diagnosing and Resetting Faults...141 Fault Occurs Simultaneously with Power Loss... 141 If the Drive Still has Power After a Fault Occurs... 141 Viewing Fault Trace Data After Fault... 141 Fault Reset Methods... 142 5.8 Troubleshooting without Fault Display...143 Cannot Change Parameter Settings... 143 Motor Does Not Rotate Properly after Pressing RUN Button or after Entering External Run Command... 143 6. PERIODIC INSPECTION & MAINTENANCE... 151 6 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

Table of Contents 6.1 Section Safety...152 6.2 Inspection...155 Recommended Daily Inspection... 155 Recommended Periodic Inspection... 156 6.3 Periodic Maintenance...159 Replacement Parts... 159 6.4 Drive Cooling Fans...161 Cooling Fan Replacement... 161 7. PERIPHERAL DEVICES & OPTIONS... 165 7.1 Section Safety...166 7.2 Peripheral Devices...168 7.3 Connecting Peripheral Devices...170 7.4 Installing Peripheral Devices...171 Installing a Molded Case Circuit Breaker (MCCB)... 171 Installing a Leakage Breaker... 172 Installing a Magnetic Contactor... 172 Connecting an AC or DC Reactor... 173 Connecting a Surge Absorber... 174 Connecting a Noise Filter... 174 Zero-Phase Reactor... 177 Installing Fuses on the Input Side... 178 Installing a Motor Thermal Overload (ol) Relay on the Drive Output... 178 NEMA Type 1 Kit... 180 7.5 Communication Options...185 A. SPECIFICATIONS... 187 A.1 Heavy Duty and Normal Duty Ratings...188 A.2 Single/Three-Phase 200 V Class Drive...189 A.3 Three-Phase 400 V Class Drives...190 A.4 Drive Specifications...191 A.5 Drive Watt Loss Data...194 A.6 Drive Derating Data...195 Temperature Derating... 195 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 7

Table of Contents B. PARAMETER LIST... 197 B.1 Parameter Groups...198 B.2 Parameter Table...199 A: Initialization Parameters... 199 b: Application... 199 C: Tuning... 201 d: References... 203 E: Motor Parameters... 204 H Parameters: Multi-Function Terminals... 206 L: Protection Function... 210 n: Advanced Performance Set-Up... 214 o: Operator Related Parameters... 214 U: Monitors... 216 B.3 Defaults Determined by Drive Capacity (o2-04) and ND/ HD (C6-01)...219 B.4 Defaults Determined by Carrier Frequency Selection (C6-02)...222 B.5 Defaults Determined by Carrier Frequency Reduction (L8-38)...223 C. STANDARDS COMPLIANCE... 225 C.1 Section Safety...226 C.2 European Standards...229 CE Low Voltage Directive Compliance... 229 EMC Guidelines Compliance... 230 C.3 UL Standards...236 UL Standards Compliance... 236 Drive Motor Overload Protection... 238 8 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

i Preface & General Safety This section provides safety messages pertinent to this product that, if not heeded, may result in fatality, personal injury, or equipment damage. Yaskawa is not responsible for the consequences of ignoring these instructions. I.1 PREFACE...10 I.2 GENERAL SAFETY...12 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 9

i.1 Preface i.1 Preface Yaskawa manufactures products used as components in a wide variety of industrial systems and equipment. The selection and application of Yaskawa products remain the responsibility of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all circumstances. All systems or equipment designed to incorporate a product manufactured by Yaskawa must be supplied to the end user with appropriate warnings and instructions as to the safe use and operation of that part. Any warnings provided by Yaskawa must be promptly provided to the end user. Yaskawa offers an express warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual. NO OTHER WARRANTY, EXPRESSED OR IMPLIED, IS OFFERED. Yaskawa assumes no liability for any personal injury, property damage, losses, or claims arising from misapplication of its products. This manual is designed to ensure correct and suitable application of Variable J1000-Series Inverters. Read this manual before attempting to install, operate, maintain, or inspect an Inverter and keep it in a safe, convenient location for future reference. Be sure you understand all precautions and safety information before attempting application. u Applicable Documentation The following manuals are available for J1000 series drives: J1000 Series Compact V/f Control Drive Installation and Start-Up Manual Read this manual first. This guide is packaged together with the product. It contains basic information required to install and wire the drive. This guide provides basic programming and simple setup and adjustment. Refer to the J1000 Technical Manual for complete descriptions of drive features and functions. J1000 Series Compact V/f Control Drive Technical Manual This manual describes installation, wiring, operation procedures, functions, troubleshooting, maintenance, and inspections to perform before operation. u Symbols Note: TERMS Indicates a supplement or precaution that does not cause drive damage. Indicates a term or definition used in this manual. 10 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

i.1 Preface u Terms and Abbreviations Drive: Yaskawa J1000 Series Drive YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 11

i.2 General Safety i.2 General Safety u Supplemental Safety Information General Precautions The diagrams in this manual may be indicated without covers or safety shields to show details. Restore covers or shields before operating the drive and run the drive according to the instructions described in this manual. Any illustrations, photographs, or examples used in this manual are provided as examples only and may not apply to all products to which this manual is applicable. The products and specifications described in this manual or the content and presentation of the manual may be changed without notice to improve the product and/or the manual. When ordering a new copy of the manual due to damage or loss, contact your Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover. If nameplate becomes worn or damaged, order a replacement from your Yaskawa representative or the nearest Yaskawa sales office. WARNING Read and understand this manual before installing, operating or servicing this drive. The drive must be installed according to this manual and local codes. The following conventions are used to indicate safety messages in this manual. Failure to heed these messages could result in serious or possibly even fatal injury or damage to the products or to related equipment and systems. DANGER Indicates a hazardous situation, which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. WARNING! will also be indicated by a bold key word embedded in the text followed by an italicized safety message. 12 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

i.2 General Safety CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. CAUTION! will also be indicated by a bold key word embedded in the text followed by an italicized safety message. Indicates a property damage message. NOTICE NOTICE: will also be indicated by a bold key word embedded in the text followed by an italicized safety message. u Safety Messages DANGER Heed the safety messages in this manual. Failure to comply will result in death or serious injury. The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings in this manual. Electrical Shock Hazard Do not connect or disconnect wiring while the power is on. Failure to comply will result in death or serious injury. Before servicing, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least one minute after all indicators are OFF and measure the DC bus voltage level to confirm safe level. YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 13

i.2 General Safety WARNING Sudden Movement Hazard System may start unexpectedly upon application of power, resulting in death or serious injury. Clear all personnel from the drive, motor and machine area before applying power. Secure covers, couplings, shaft keys and machine loads before applying power to the drive. Electrical Shock Hazard Do not attempt to modify or alter the drive in any way not explained in this manual. Failure to comply could result in death or serious injury. Yaskawa is not responsible for any modification of the product made by the user. This product must not be modified. Do not allow unqualified personnel to use equipment. Failure to comply could result in death or serious injury. Maintenance, inspection, and replacement of parts must be performed only by authorized personnel familiar with installation, adjustment and maintenance of AC drives. Do not remove covers or touch circuit boards while the power is on. Failure to comply could result in death or serious injury. Fire Hazard Do not use an improper voltage source. Failure to comply could result in death or serious injury by fire. Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power. CAUTION Crush Hazard Do not carry the drive by the front cover. Failure to comply may result in minor or moderate injury from the main body of the drive falling. 14 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

i.2 General Safety NOTICE Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit boards. Failure to comply may result in ESD damage to the drive circuitry. Never connect or disconnect the motor from the drive while the drive is outputting voltage. Improper equipment sequencing could result in damage to the drive. Do not perform a withstand voltage test on any part of the drive. Failure to comply could result in damage to the sensitive devices within the drive. Do not operate damaged equipment. Failure to comply could result in further damage to the equipment. Do not connect or operate any equipment with visible damage or missing parts. Install adequate branch circuit short circuit protection per applicable codes. Failure to comply could result in damage to the drive. The drive is suitable for circuits capable of delivering not more than 30,000 RMS symmetrical Amperes, 240 Vac maximum (200 V Class) and 480 Vac maximum (400 V Class). Do not expose the drive to halogen group disinfectants. Failure to comply may cause damage to the electrical components in the drive. Do not pack the drive in wooden materials that have been fumigated or sterilized. Do not sterilize the entire package after the product is packed. u Drive Label Warnings Always heed the warning information listed in Figure i.1 in the position shown in Figure i. 2. YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 15

i.2 General Safety WARNING Risk of electric shock. Read manual before installing. Wait 1 minute for capacitor discharge after disconnecting power supply. To conform to requirements, make sure to ground the supply neutral for 400V class. Figure i.1 Warning Information Warning Label Figure i.2 Warning Information Position u Warranty Information Warranty Period This drive is warranted for 12 months from the date of delivery to the customer or 18 months from the date of shipment from the Yaskawa factory, whichever comes first. 16 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

i.2 General Safety Scope of Warranty Inspections Customers are responsible for periodic inspections of the drive. Upon request, a Yaskawa representative will inspect the drive for a fee. If the Yaskawa representative finds the drive to be defective due to Yaskawa workmanship or materials and the defect occurs during the warranty period, this inspection fee will be waived and the problem remedied free of charge. Repairs If a Yaskawa product is found to be defective due to Yaskawa workmanship or materials and the defect occurs during the warranty period, Yaskawa will provide a replacement, repair the defective product, and provide shipping to and from the site free of charge. However, if the Yaskawa Authorized Service Center determines that the problem with the drive is not due to defective workmanship or materials, the customer will be responsible for the cost of any necessary repairs. Some problems that are outside the scope of this warranty are: Problems due to improper maintenance or handling, carelessness, or other reasons where the customer is determined to be responsible. Problems due to additions or modifications made to a Yaskawa product without Yaskawa's understanding. Problems due to the use of a Yaskawa product under conditions that do not meet the recommended specifications. Problems caused by natural disaster or fire. After the free warranty period elapses. Replenishment or replacement of consumables or expendables. Defective products due to packaging or fumigation. Other problems not due to defects in Yaskawa workmanship or materials. Warranty service is only applicable within Japan. However, after-sales service is available for customers outside of Japan for a reasonable fee. Contact your local Yaskawa representative for more information. Exceptions Any inconvenience to the customer or damage to non-yaskawa products due to Yaskawa s defective products whether within or outside of the warranty period are NOT covered by warranty. Restrictions The J1000 was not designed or manufactured for use in devices or systems that may directly affect or threaten human lives or health. YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 17

i.2 General Safety Customers who intend to use the product described in this manual for devices or systems relating to transportation, health care, space aviation, atomic power, electric power, or in underwater applications must first contact their Yaskawa representatives or the nearest Yaskawa sales office. This product has been manufactured under strict quality-control guidelines. However, if this product is to be installed in any location where failure of this product could involve or result in a life-and-death situation or loss of human life or in a facility where failure may cause a serious accident or physical injury, safety devices must be installed to minimize the likelihood of any accident. u Quick Reference Run a Motor of One-Frame Larger Capacity When using this drive for variable torque loads such as fans and pumps, a motor one frame size larger can be used. Know the Details of Safety Measures The functions listed below affect the safe operation of the drive. Ensure that the settings fit the application requirements prior to operation. Safe operations. Run by power on. Parameter setting b1-17. LOCAL/REMOTE key effective during stop in drive mode. Parameter o2-01. LED operator stop key priority selection. Parameter o2-02. Enter press required after changing the keypad frequency reference. Parameter o2-05. Operation interlock when program mode is selected. Parameter b1-08. Check the Maintenance Period Using Drive Monitors The maintenance period of fans and capacitors can be checked with drive monitors. Drive or Motor Faults are Displayed on a Digital Operator Refer to Fault Displays, Causes, and Possible Solutions on page 126 and Refer to Alarm Codes, Causes, and Possible Solutions on page 134. Standards Compliance Refer to European Standards on page 229 and Refer to UL Standards on page 236. C U R L US LISTED 18 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

1 Receiving This chapter describes the proper inspections to perform after receiving the drive and illustrates the different enclosure types and components. 1.1 SECTION SAFETY...20 1.2 MODEL NUMBER AND NAMEPLATE CHECK...21 1.3 DRIVE MODELS...24 1.4 COMPONENT NAMES...25 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 19

1.1 Section Safety 1.1 Section Safety CAUTION Do not carry the drive by the front cover. Failure to comply may cause the main body of the drive to fall, resulting in minor or moderate injury. NOTICE Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit boards. Failure to comply may result in ESD damage to the drive circuitry. A motor connected to a PWM drive may operate at a higher temperature than a utilityfed motor and the operating speed range may reduce motor cooling capacity. Ensure that the motor is suitable for inverter duty and/or the motor service factor is adequate to accommodate the additional heating with the intended operating conditions. 20 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

1.2 Model Number and Nameplate Check 1.2 Model Number and Nameplate Check Please perform the following tasks after receiving the drive: Inspect the drive for damage. If the drive appears damaged upon receipt, contact the shipper immediately. Verify receipt of the correct model by checking the information on the nameplate. If you have received the wrong model or the drive does not function properly, contact your supplier. u Nameplate Receiving 1 Drive model Input specifications Output specifications Lot number Serial number MODEL : CIMR-JA2A0004BAA C U L US MAX APPLI. MOTOR : 0.75kW / 0.4kW REV : A LISTED INPUT : AC3PH 200-240V 50 / 60Hz 2.7A / 1.4A IND.CONT.EQ. OUTPUT : AC3PH 0-240V 0-400Hz 1.2A / 0.8A 7J48 B MASS : 0.9 kg PRG : 1010 O / N : S / N : FILE NO : E131457 IP20 YASKAWA ELECTRIC CORPORATION PASS MADE IN JAPAN Software version Figure 1.1 Nameplate Information YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 21

1.2 Model Number and Nameplate Check CIMR - J A 2 A 0001 B A A Drive No. A T J1000 Series Region Code Japan Asia No. B 2 4 No. Customized Specifications No. Enclosure Type A Standard model B IP20 Voltage Class 1-phase, 200-240 Vac 3-phase, 200-240 Vac 3-phase, 380-480 Vac No. A M N S Environmental Specification <1> Standard Humidity- and dust-resistant Oil-resistant Vibration-resistant Design Revision Order Single-Phase 200 V Normal Duty Heavy Duty No. Max. Motor Capacity kw Rated Output Current A No. Max. Motor Capacity kw Rated Output Current A 0001 0.2 1.2 0001 0.1 0.8 0002 0.4 1.9 0002 0.2 1.6 0003 0.75 3.3 0003 0.4 3 0006 1.1 6 0006 0.75 5 0010 2.2 9.6 0010 1.5 8 Three-Phase 200 V Normal Duty Heavy Duty No. Max Motor Capacity kw Rated Output Current A No. Max Motor Capacity kw Rated Output Current A 0001 0.2 1.2 0001 0.1 0.8 0002 0.4 1.9 0002 0.2 1.6 0004 0.75 3.5 0004 0.4 3 0006 1.1 6 0006 0.75 5 0008 1.5 8.0 0008 1.1 6.9 0010 2.2 9.6 0010 1.5 8 0012 3.0 12 0012 2.2 11 0018 3.7 17.5 0018 3.0 14.0 0020 5.5 19.6 0020 3.7 17.5 22 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

1.2 Model Number and Nameplate Check Three-Phase 400 V Normal Duty Heavy Duty No. Max. Motor Capacity kw Rated Output Current A No. Max. Motor Capacity kw Rated Output Current A 0001 0.4 1.2 0001 0.2 1.2 0002 0.75 2.1 0002 0.4 1.8 0004 1.5 4.1 0004 0.75 3.4 0005 2.2 5.4 0005 1.5 4.8 0007 3.0 6.9 0007 2.2 5.5 0009 3.7 8.8 0009 3.0 7.2 0011 5.5 11.1 0011 3.7 9.2 <1> Drives with these specifications do not guarantee complete protection for the specified environmental condition. Receiving 1 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 23

1.3 Drive Models 1.3 Drive Models The following table describes drive models. Voltage Class Single-Phase 200 V Class Three-Phase 200 V Class Three-Phase 400 V Class Table 1.1 Drive Models IP20/Open-Chassis CIMR-Jo BA0001B BA0002B BA0003B BA0006B BA0010B 2A0001B 2A0002B 2A0004B 2A0006B 2A0008B 2A0010B 2A0012B 2A0018B 2A0020B 4A0001B 4A0002B 4A0004B 4A0005B 4A0007B 4A0009B 4A0011B 24 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

1.4 Component Names 1.4 Component Names This section illustrates the drive components as they are mentioned in this manual. u IP20/Open-Chassis Single-Phase AC200 V CIMR-JoBA0001B ~ 0003B Three-Phase AC200 V CIMR-Jo2A0001B ~ 0006B K I J A Receiving F G H C B 1 E D A Mounting hole B Heatsink C Cable cover D Terminal cover E Front cover screw F Option connector cover G Front cover H LED operator Refer to Using the Digital LED Operator on page 73 I Case J Cooling fan <1> K Fan cover <1> Figure 1.2 Exploded View of IP20/Open-Chassis Type Components Three-Phase AC200 V CIMR-Jo2A0006B <1> The drives CIMR-JoBA0001B ~ 0003B and CIMR-Jo2A0001B ~ 0004B do not have a cooling fan or a cooling fan cover. YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 25

1.4 Component Names Single-Phase AC200 V CIMR-JoBA0006B ~ 0010B Three-Phase AC200 V CIMR-Jo2A0008B ~ 0020B Three-Phase AC400 V CIMR-Jo4A0001B ~ 0011B K L J A I B G H D C F E A Mounting hole B Heatsink C Cable cover D Terminal cover E Bottom cover F Front cover screw G Option connector cover H Front cover I LED operator Refer to Using the Digital LED Operator on page 73 J Case K Cooling fan <1> L Fan cover <1> Figure 1.3 Exploded view of IP20/Open-Chassis Type Components Three-Phase AC200 V CIMR-Jo2A0012B <1> The drives CIMR-JoBA0006B and CIMR-Jo4A0001B ~ 0004B do not have a cooling fan or a cooling fan cover. 26 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

1.4 Component Names u Front Views CIMR-J 2A0006B CIMR-J 2A0012B G A B G A B F C D E A DIP switch S1 Refer to DIP Switch S1 Analog Input Signal Selection on page 63 B DIP switch S3 Refer to Sinking/ Sourcing Mode Switch on page 60 C Control circuit terminal Refer to Control Circuit Wiring on page 54 D Main circuit terminal Refer to Wiring the Main Circuit Terminal on page 53 F E Ground terminal F Terminal cover G Option unit connector Figure 1.4 Front Views of Drives C D E Receiving 1 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 27

1.4 Component Names This Page Intentionally Blank 28 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

2 Mechanical Installation This chapter explains how to properly mount and install the drive. 2.1 SECTION SAFETY...30 2.2 MECHANICAL INSTALLATION...33 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 29

2.1 Section Safety 2.1 Section Safety WARNING Fire Hazard Provide sufficient cooling when installing the drive inside an enclosed panel or cabinet. Failure to comply could result in overheating and fire. When multiple drives are placed inside the same enclosure panel, install proper cooling to ensure air entering the enclosure does not exceed 40 C. CAUTION Crush Hazard Do not carry the drive by the front cover. Failure to comply may result in minor or moderate injury from the main body of the drive falling. 30 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

2.1 Section Safety NOTICE Observe proper electrostatic discharge (ESD) procedures when handling the drive. Failure to comply could result in ESD damage to the drive circuitry. It may be difficult to perform maintenance on the cooling fans of drives installed in a vertical row inside an enclosure. Ensure adequate spacing at the top of the drive to perform cooling fan replacement when required. Operating the motor in the low-speed range diminishes the cooling effects, increases motor temperature, and may lead to motor damage by overheating. Reduce the motor torque in the low-speed range whenever using a standard blower cooled motor. If 100% torque is required continuously at low speed, consider using a special drive or vector motor. Select a motor that is compatible with the required load torque and operating speed range. Do not operate motors above the maximum rated RPM. Failure to comply may lead to bearing or other mechanical motor failures. The speed range for continuous operation differs according to the lubrication method and motor manufacturer. If the motor is to be operated at a speed higher than the rated speed, consult with the manufacturer. Continuously operating an oil-lubricated motor in the low-speed range may result in burning. Mechanical Installation 2 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 31

2.1 Section Safety NOTICE When the input voltage is 440 V or higher or the wiring distance is greater than 100 meters, pay special attention to the motor insulation voltage or use a drive-rated motor. Failure to comply could lead to motor winding failure. Motor vibration may increase when operating a machine in variable-speed mode, if that machine previously operated at a constant speed. Install vibration-proof rubber on the motor base or use the frequency jump function to skip a frequency resonating the machine. The motor may require more acceleration torque with drive operation than with a commercial power supply. Set a proper V/f pattern by checking the load torque characteristics of the machine to be used with the motor. The rated input current of submersible motors is higher than the rated input current of standard motors. Select an appropriate drive according to its rated output current. When the distance between the motor and drive is long, use a cable thick enough to connect the motor to the drive to prevent motor torque reduction. When using an explosion-proof motor, it must be subject to an explosion-proof test in conjunction with the drive. This is also applicable when an existing explosion-proof motor is to be operated with the drive. Since the drive itself is not explosion-proof, always install it in a safe place. Do not use a drive for a single-phase motor. Replace the motor with a three-phase motor. If an oil-lubricated gearbox or speed reducer is used in the power transmission mechanism, oil lubrication will be affected when the motor operates only in the low speed range. The power transmission mechanism will make noise and experience problems with service life and durability if the motor is operated at a speed higher than the rated speed. 32 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

2.2 Mechanical Installation 2.2 Mechanical Installation This section outlines specifications, procedures, and environment for proper mechanical installation of the drive. u Installation Environment To help prolong the optimum performance life of the drive, install the drive in the proper environment. The table below provides a description of the appropriate environment for the drive. Table 2.1 Installation Environment Environment Conditions Installation Area Indoors -10 C to +50 C (IP20/Open-Chassis) Ambient Drive reliability improves in environments without wide temperature fluctuations. Temperature When using an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the air temperature inside the enclosure does not exceed the specified levels. Do not allow ice to develop on the drive. Humidity 95% RH or less and free of condensation Storage Temperature -20 C to +60 C Install the drive in an area free from: oil mist and dust metal shavings, oil, water or other foreign materials radioactive materials Surrounding Area combustible materials (e.g., wood) harmful gases and liquids excessive vibration chlorides direct sunlight Altitude 1000 m or lower Vibration 10 to 20 Hz at 9.8 m/s 2 20 to 55 Hz at 5.9 m/s 2 Orientation Install the drive vertically to maintain maximum cooling effects. NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during installation and project construction. Failure to comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary cover before startup, as the cover will reduce ventilation and cause the drive to overheat. Mechanical Installation 2 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 33

2.2 Mechanical Installation u Installation Orientation and Spacing Install the drive upright as illustrated in Figure 2.1 to maintain proper cooling. A B B A Correct B Incorrect Figure 2.1 Correct Installation Orientation Single Drive Installation Figure 2.2 explains the required installation spacing to maintain sufficient space for airflow and wiring. Install the heatsink against a closed surface to avoid diverting cooling air around the heatsink. Side Clearance Top/Bottom Clearance A A C B C A 30 mm minimum B Airflow direction C 100 mm minimum Figure 2.2 Correct Installation Spacing 34 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

2.2 Mechanical Installation Multiple Drive Installation When installing multiple drives into the same enclosure panel, mount the drives according to Figure 2.2. When mounting drives with a minimum side-by-side clearance of 2 mm according to Figure 2.3, derating must be considered and parameter L8-35 must be set. Refer to Parameter List on page 197. A B 2 mm B C A Line up the tops of the drives. B 30 mm minimum C C 100 mm minimum D Airflow direction Figure 2.3 Space Between Drives (Side-by-Side Mounting) D Mechanical Installation 2 Note: When installing drives of different sizes into the same enclosure panel, the tops of the drives should line up. Leave space between the top and bottom of stacked drives for cooling fan replacement if required. Using this method, it is possible to replace the cooling fans later. u Removing and Attaching the Protective Covers Refer to Electrical Installation on page 39, for information regarding the removal and reattachment of protective covers. u Exterior and Mounting Dimensions The following table matches each drive model with its appropriate drawing. YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 35

2.2 Mechanical Installation Protective Design IP20/Open-Chassis Single-Phase 200 V Class BA0001B BA0002B BA0003B BA0006B BA0010B Table 2.2 Drive Models Drive Model CIMR-Jo Three-Phase 200 V Class 2A0001B 2A0002B 2A0004B 2A0006B 2A0008B 2A0010B 2A0012B 2A0018B 2A0020B Three-Phase 400 V Class Page 37 4A0001B 4A0002B 4A0004B 4A0005B 4A0007B 4A0009B 4A0011B 38 Note: Refer to Specifications on page 187 for information on the amount of heat generated by the drive and appropriate cooling methods. 36 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

2.2 Mechanical Installation IP20/Open-Chassis Drives Table 2.3 IP20/Open-Chassis (without an EMC filter) D2 W1 2-M4 t1 H1 H Voltage Class Single-Phase 200 V Class Three-Phase 200 V Class W Drive Model CIMR-Jo H2 D Dimensions (mm) W H D W1 H1 H2 D1 D2 t1 D1 Weight (kg) BA0001B 68 128 76 56 118 5 6.5 67.5 3 0.6 BA0002B 68 128 76 56 118 5 6.5 67.5 3 0.6 BA0003B 68 128 118 56 118 5 38.5 109.5 5 1.0 2A0001B 68 128 76 56 118 5 6.5 67.5 3 0.6 2A0002B 68 128 76 56 118 5 6.5 67.5 3 0.6 2A0004B 68 128 108 56 118 5 38.5 99.5 5 0.9 2A0006B 68 128 128 56 118 5 58.5 119.5 5 1.1 Mechanical Installation 2 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 37

2.2 Mechanical Installation Table 2.4 IP20/Open-Chassis (without an EMC filter) W1 4-M4 D2 W H2 H1 H D D1 t1 Voltage Class Single-Phase 200 V Class Three-Phase 200 V Class Three-Phase 400 V Class Dimensions (mm) Drive Model CIMR-Jo W H D W1 H1 H2 D1 D2 t1 Weight (kg) BA0006B 108 128 137.5 96 118 5 58 129 5 1.7 BA0010B 108 128 154 96 118 5 58 145.5 5 1.8 2A0008B 108 128 129 96 118 5 58 120.5 5 1.7 2A0010B 108 128 129 96 118 5 58 120.5 5 1.7 2A0012B 108 128 137.5 96 118 5 58 129 5 1.7 2A0018B 140 128 143 128 118 5 65 134.5 5 2.4 2A0020B 140 128 143 128 118 5 65 134.5 5 2.4 4A0001B 108 128 81 96 118 5 10 72.5 5 1.0 4A0002B 108 128 99 96 118 5 28 90.5 5 1.2 4A0004B 108 128 137.5 96 118 5 58 129 5 1.7 4A0005B 108 128 154 96 118 5 58 145.5 5 1.7 4A0007B 108 128 154 96 118 5 58 145.5 5 1.7 4A0009B 108 128 154 96 118 5 58 145.5 5 1.7 4A0011B 140 128 143 128 118 5 65 134.5 5 2.4 38 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

3 Electrical Installation This chapter explains proper procedures for wiring the control circuit terminals, motor and power supply. 3.1 SECTION SAFETY...40 3.2 STANDARD CONNECTION DIAGRAM...43 3.3 MAIN CIRCUIT CONNECTION DIAGRAM...46 3.4 TERMINAL BLOCK CONFIGURATION...47 3.5 PROTECTIVE COVERS...48 3.6 MAIN CIRCUIT WIRING...50 3.7 CONTROL CIRCUIT WIRING...54 3.8 I/O CONNECTIONS...60 3.9 MAIN FREQUENCY REFERENCE...63 3.10 BRAKING RESISTOR...65 3.11 INTERLOCKING WITH CONNECTED MACHINERY...67 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 39

3.1 Section Safety 3.1 Section Safety DANGER Electrical Shock Hazard Do not connect or disconnect wiring while the power is on. Failure to comply will result in death or serious injury. WARNING Electrical Shock Hazard Do not operate equipment with covers removed. Failure to comply could result in death or serious injury. The diagrams in this section may show drives without covers or safety shields to show details. Be sure to reinstall covers or shields before operating the drives and run the drives according to the instructions described in this manual. Always ground the motor-side grounding terminal. Improper equipment grounding could result in death or serious injury by contacting the motor case. Do not perform work on the drive while wearing loose clothing, jewelry or without eye protection. Failure to comply could result in death or serious injury. Remove all metal objects such as watches and rings, secure loose clothing, and wear eye protection before beginning work on the drive. Do not remove covers or touch circuit boards while the power is on. Failure to comply could result in death or serious injury. Do not allow unqualified personnel to perform work on the drive. Failure to comply could result in death or serious injury. Installation, maintenance, inspection, and servicing must be performed only by authorized personnel familiar with installation, adjustment, and maintenance of AC drives. 40 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

3.1 Section Safety WARNING Do not touch any terminals before the capacitors have fully discharged. Failure to comply could result in death or serious injury. Before wiring terminals, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least one minute after all indicators are off and measure the DC bus voltage level to confirm safe level. Fire Hazard Tighten all terminal screws to the specified tightening torque. Loose electrical connections could result in death or serious injury by fire due to overheating of electrical connections. Do not use improper combustible materials. Failure to comply could result in death or serious injury by fire. Attach the drive to metal or other noncombustible material. Do not use an improper voltage source. Failure to comply could result in death or serious injury by fire. Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power. Electrical Installation 3 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 41

3.1 Section Safety NOTICE Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit boards. Failure to comply may result in ESD damage to the drive circuitry. Never connect or disconnect the motor from the drive while the drive is outputting voltage. Improper equipment sequencing could result in damage to the drive. Do not use unshielded cable for control wiring. Failure to comply may cause electrical interference resulting in poor system performance. Use shielded, twisted-pair wires and ground the shield to the ground terminal of the drive. Check all the wiring to ensure that all connections are correct after installing the drive and connecting any other devices. Failure to comply could result in damage to the drive. Do not modify the drive circuitry. Failure to comply could result in damage to the drive and will void warranty. Yaskawa is not responsible for any modification of the product made by the user. This product must not be modified. 42 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

3.2 Standard Connection Diagram 3.2 Standard Connection Diagram Connect the drive and peripheral devices as shown in Figure 3.1. It is possible to run the drive via the digital operator without connecting digital I/O wiring. This section does not discuss drive operation; Refer to Start-Up Programming & Operation on page 69 for instructions on operating the drive. NOTICE: Inadequate branch short circuit protection could result in damage to the drive. Install adequate branch circuit short circuit protection per applicable codes. The drive is suitable for circuits capable of delivering not more than 30,000 RMS symmetrical amperes, 240 Vac maximum (200 V Class) and 480 Vac maximum (400 V Class). NOTICE: When the input voltage is 440 V or higher or the wiring distance is greater than 100 meters, pay special attention to the motor insulation voltage or use an inverter duty motor. Failure to comply could lead to motor insulation breakdown. NOTICE: Do not connect the AC control circuit ground to the drive enclosure. Improper drive grounding can cause the control circuit to malfunction. NOTICE: The minimum load for the multi-function relay output MA-MB-MC is 10 ma. Electrical Installation 3 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 43

3.2 Standard Connection Diagram For single phase 200 V power supply, use R/L1 and S/L2. Three phase R/L1 power supply S/L2 200 to 240 V T/L3 Thermal relay for motor cooling fan 1 MCCB MC 2 MCCB THRX OFF ON MC MC MC _ Terminals +1, +2,, B1, and B2 are for connecting options. Never connect power supply lines to these terminals. MA SA MC THRX SA TRX SA TRX Fault relay Forward run/stop Reverse run/stop External fault 2 MCCB r1 Fault reset Multi-step speed 1 main/aux switch <3> s1 t1 <4> R/L1 DC reactor (option) S/L2 Main circuit T/L3 S1 S2 S3 S4 S5 Jumper <1> J1000 Control circuit <2> Thermal relay (option) Braking resistor (option) +2 +1 - B1 B2 +24 V 8 ma Option unit connector I U/T1 V/T2 W/T3 DIP switch S1 V r1 s1 t1 MA Fault Motor Cooling fan FU FV FW U V W M M Ground 10 or less (400 V class) 100 or less (200 V class) Digital output 250 Vac, 10 ma to 1 A 30 Vdc, 10 ma to 1 A (default setting) <6> MB Digital inputs (default setting) SC <5> DIP switch S3 Sink Source 24 V MC Shield ground terminal Main speed frequency reference. Multi-function programmable 2 k Setting power supply +V +10.5 max. 20 ma A1 0 to +10 V (20 k ) (0)4 to 20 ma (250 ) AC AM AC Analog monitor + output AM 0 to +10 Vdc - (2 ma) Monitor output <7> shielded line main circuit terminal twisted-pair shielded line control terminal Figure 3.1 Drive Standard Connection Diagram (200 V Class Example) <1> Remove the jumper when installing an optional DC reactor. <2> The MC on the input side of the main circuit should open when the thermal relay is triggered. <3> Self-cooled motors do not require separate cooling fan motor wiring. <4> Connected using sequence input signal (S1 to S5) from NPN transistor; Default: sink mode (0 V com). <5> Use only a +24 V internal power supply in sinking mode; the source mode requires an external power supply Refer to I/O Connections on page 60. <6> Minimum load: 5 Vdc, 10 ma (reference value). 44 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

3.2 Standard Connection Diagram <7> Monitor outputs work with devices such as analog frequency meters, ammeters, voltmeters and wattmeters; they are not intended for use as a feedback-type of signal. WARNING! Sudden Movement Hazard. Do not close the wiring for the control circuit unless the multifunction input terminal parameter is properly set (S5 for 3-Wire; H1-05 = 0 ). Improper sequencing of run/stop circuitry could result in death or serious injury from moving equipment. WARNING! Sudden Movement Hazard. Ensure start/stop and safety circuits are wired properly and in the correct state before energizing the drive. Failure to comply could result in death or serious injury from moving equipment. When programmed for 3-Wire control, a momentary closure on terminal S1 may cause the drive to start. WARNING! When 3-Wire sequence is used, set the drive to 3-Wire sequence before wiring the control terminals and ensure parameter b1-17 is set to 0 (drive does not accept a run command at power up (default). If the drive is wired for 3-Wire sequence but set up for 2-Wire sequence (default) and if parameter b1-17 is set to 1 (drive accepts a Run command at power up), the motor will rotate in reverse direction at power up of the drive and may cause injury. Figure 3.2 illustrates an example of a 3-Wire sequence. Stop relay (N.C.) Run relay (N.O.) S1 S2 S5 SC Drive Run command (run on momentary close) Stop command (stop on momentary open) Foward/reverse command (multi-function input: H1-05 = 0) Sequence input common Electrical Installation Figure 3.2 3-Wire Sequence 3 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 45

3.3 Main Circuit Connection Diagram 3.3 Main Circuit Connection Diagram Refer to diagrams in this section for the Main Circuit wiring connections. Connections may vary based on drive capacity. The main circuit DC power supply powers the control circuit. NOTICE: Do not use the negative DC bus terminal - as a ground terminal. This terminal is at high voltage DC potential. Improper wiring connections could result in damage to the drive. u Single-Phase 200 V Class (CIMR-JoBA0001 ~ 0010) Jumper DC reactor (option) Braking Resistor Unit (option) Single-phase 200 Vac R/L1 S/L2 +2 +1 B1 Drive B2 U/T1 V/T2 W/T3 Motor Figure 3.3 Connecting Single-Phase Main Circuit Terminals NOTICE: Do not connect T/L3 terminal when using single-phase power supply input. Incorrect wiring may damage the drive. u Three-Phase 200 V Class (CIMR-Jo2A0001 ~ 0020); Three-Phase 400 V Class (CIMR-Jo4A0001 ~ 0011) Jumper DC reactor (option) Braking Resistor Unit (option) +2 +1 B1 B2 Three phase 200 Vac (400 Vac) R/L1 S/L2 T/L3 Drive U/T1 V/T2 W/T3 Motor Figure 3.4 Connecting Three-Phase Main Circuit Terminals 46 YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual

3.4 Terminal Block Configuration 3.4 Terminal Block Configuration The figures in this section provide illustrations of the main circuit terminal block configurations of the different drive sizes. Models: CIMR-J BA0001, 0002, 0003 CIMR-J 2A0001, 0002, 0004, 0006 Models: CIMR-J BA0006, 0010 CIMR-J 2A0008, 0010, 0012, 0018, 0020 CIMR-J 4A0001, 0002, 0004, 0005, 0007 0009, 0011 Electrical Installation 3 Figure 3.5 Main Circuit Terminal Block Configurations YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual 47