SIPROTEC 5 Application Note

Similar documents
SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application. SIP5-APN-027: Change of switching authority via function keys.

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

SIPROTEC 5 Application Note

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

Extension of BI/BO for busbar protection SIPROTEC 7SS85

Change setting groups via CFC.

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Voltage Control of Transformers in Parallel Operation

Perfect protection smallest space

Perfect protection smallest space

Voltage control of transformers in parallel operation.

Always an eye to security

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIPROTEC 5 Protection, automation, and monitoring

Go beyond... IEC Leverage the full potential with leading-edge expertise. Answers for infrastructure and cities.

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

Substation to substation (ss2ss) GOOSE exchange for critical relay operations

Product Families and Positioning. Protection Portfolio

Catalog Edition 6 siemens.com/protection

Siprotec 7ST61 / 7ST63

SIPROTEC 5 Engineering Guide DIGSI 5

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Lecture 5 Substation Automation Systems. Course map

UPGRADE AND APPLICATION OF AUTOMATION SYSTEM IN T.S. 110/35/10 KV PETROVEC

Busbar protection REB 670

Easily configurable HMI system for power automation siemens.com/sicam

Time synchronization via IEE 1588

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Digital Substation Unrestricted Siemens AG 2017 siemens.com/digital-substation

This application note describes configuring automatic bus transfer (ABT) logic with two V57 relays.

Lecture 6 Substation Automation Systems

5SL Miniature Circuit Breakers

SPECIAL CONSIDERATION OF FEEDER PROTECTION FOR BREAKER-AND-A-HALF CONFIGURA- TIONS. G. Steynberg

Siemens AG All rights reserved.

SIPROTEC 5 Devices Protection, Automation and Monitoring

Air-insulated medium-voltage secondary distribution switchgear

SIMEAS Q80 quality recorder: Voltage quality starts with measurement.

SIPROTEC 5 New features of V7.5

SICAM AK 3. Flexible automation for all applications. Automation, telecontrol and communication for large data volume.

AUTOMATED TESTING OF BUSBAR DIFFERENTIAL PROTECTION USING A SYSTEM-BASED APPROACH. Christopher Pritchard, Florian Fink

Communication in Substations with IEC Simple Communication Test with IEC Johannes Bruss, Siemens AG, E D EA PRO LM Siemens AG 2008

Substation Automation Products. Line differential protection RED670 Relion 670 series

SIPROTEC Overcurrent Protection 7SJ80. Motor Protection 7SK80. Preface. Content. Data in the PROFINET IO Mapping 1. Standard Mapping

Uniform parameterisation, operation, and monitoring of intelligent switchboards

Jim McGhee, Utility Market Manager, RuggedCom Inc.

Energy Automation Catalog SICAM

Network Configuration Document Selection for New Substations Framework

Electrical Integration with Smart Communication

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

A solution for applying IEC function blocks in the development of substation automation systems

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Lars Frisk, Frantz Kruger, Integrator Partner Seminar 2012 Bay level product news Relion & supporting products

The complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00. Answers for energy.

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

Blueprint Data Center

PROTECTION, AUTOMATION & CONTROL

Miniature Circuit Breakers for Railway Applications

Automation System Solutions

Grid Automation Controller COM600 How it fits into the Smart Grid?

SIMEAS SAFIR The network quality system

HiPath Description. We are now Unify.

The System for Power Automation

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Secure energy supply Energy Automation for Infrastructure and Functional Buildings

SIPROTEC 4 6MD66 High-Voltage Bay Control Unit

ABB AG - EPDS. Gas-insulated switchgear Type ZX2

Verification of Utility Requirements on Modern Numerical Busbar Protection by Dynamic Simulation

Christian Pinzon, ABB Power Grids The power of one solution for distributed busbar protection What s new in Relion REB500 version 8?

Digital Protection Past, Present, and Future

How smart can the grid really be?

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Application Notes on Generator Protection Schemes

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Trends in Station Bus and Process Bus Communications Via the Several IEC Protocols. Schweitzer Engineering Laboratories, Inc.

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1

SIPROTEC 4 7SS52 Distributed Numerical Busbar and Breaker Failure Protection

Combinable for All Applications

Applications & Tools. SINAMICS G/S: Commissioningsupport scripts for SINAMICS drives. SINAMICS commissioning auxiliary scripts

THE INTEGRATED TESTING SOLUTION

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management

Hierarchical protection control system of smart substations

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

SIGUARD System for Phasor Data Processing

Automation Unit TM 1703 ACP. SICAM 1703 flexible for all applications. Answers for energy.

IDS SAS. Station Automation System for Complex Applications

SICAM ertu Your Entry to Telecontrol Technology with Extended Functionality

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Power Transmission and Distribution. I m on guard here! SIMEAS R reports power system weaknesses quickly and accurately

Transcription:

www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-012 : Control of Breaker-and-a-half diameters and double busbar configurations and use of Phasor Measurement Unit (PMU) Answers for infrastructure and cities.

SIPROTEC 5 - Application: SIP5-APN-012 Control of Breaker-and-a-half diameter and double busbar configurations and use of Phasor Measurement Unit (PMU) Content 1 Application: Control of Breaker-and-a-half diameters and double busbar configurations and use of Phasor Measurement Unit (PMU) 3 1.1 Summary 3 1.2 Introduction to the application 3 1.3 Solutions 3 1.3.1 Breaker-and-a-half application 3 1.3.2 Double busbar with switchgear interlocking protection 8 1.3.3 Phasor Measurement Unit (PMU) 10 SIP5-APN-012 2

1 Application: Control of Breaker-and-a-half diameters and double busbar configurations and use of Phasor Measurement Unit (PMU) 1.1 Summary This application description explains the use of SIPROTEC 5 bay controllers in breaker-and-a-half applications and in double busbar systems. It illustrates the basic principles and possible uses of the bay controllers and their integrated functions e.g PMU. 1.2 Introduction to the application This application note describes the following application examples: Breaker-and-a-half application: For control of breaker-and-a-half diameters there are in principal two methods: Controlling the entire diameter with 1 bay controller. This is possible with the modular and flexible SIPROTEC 5 bay controllers. Controlling the diameter with 3 bay controllers. This preserves the redundancy that exists in the primary equipment (1 ½ circuit breakers per feeder) also in the secondary equipment. Double busbar configurations Control and interlocking of a double busbar feeder with query of the coupling via GOOSE Phasor Measurement Unit with interface as per IEEE C37.118 1.3 Solutions 1.3.1 Breaker-and-a-half application Figure 1 shows a breaker-and-a-half configuration. The two lines 1 and 2 can be connected to busbar 1 or 2 via the 3 circuit breakers QA1, QA2 and QA3 in the three sections A, B and C. This implies a certain degree of redundancy in the primary equipment, because both lines can still be supplied reliably in any case even if one circuit breaker is faulted. A total of 17 switching devices (circuit breakers, disconnectors and grounding switches) exist in a breakerand-a-half diameter, as shown in Figure 1. Depending on the philosophy, the diameter can be controlled by one 6MD86 bay controller or by three bay controllers. The solution in the first case is cost-efficient and uses the full flexibility of the device when connecting multiple voltage transformers. In the second case, hardware redundancy is also ensured on the secondary side. In this application, we will concentrate on the first solution. We select a bay controller with 2 x IO202 and 3 x IO207 (available as standard variant). We thus obtain a quantity structure of 67 binary inputs, 39 binary outputs (incl. life contact), 8 current transformers and 8 voltage transformers. 3 SIP5-APN-012

Figure 2 shows the assignment of the voltage transformer connections of the bay controller to the breakerand-a-half diameter. The voltages of the feeders and busbars are used for the synchrocheck of the circuit breakers. Based on the disconnector positions, it is decided which of the two voltages the synchrocheck functions use for their decision. The voltage selection logic is created in CFC. Figure 1: Schema of a breaker-and-a-half diameter SIP5-APN-012 4

Figure 2: Controlling of a diameter with one 6MD86 bay controlle Figure 2 shows that a "2 out of 4" decision for the synchronization voltages must be created at each circuit breaker. This decision depends on the switch position. To this end, CFC charts evaluate the positions of the circuit breakers and disconnectors and derive the valid transformer combination for the corresponding situation. Figure 3 shows the entire diameter with protection devices and bay controllers. The current transformers are also depicted. The tasks are distributed as follows: The combined 7SL87 distance and differential protection devices assume the line protection with the backup protection function being configured for the other line respectively. They also assume the functions "circuit-breaker failure protection" and "automatic reclosing" for two circuit breakers respectively (the center breaker QA2 is operated twice). The bay controllers are responsible for controlling all 17 switching devices, synchrocheck of the circuit breakers and the measured values (e.g. power measurement in the line feeders). 5 SIP5-APN-012

Figure 3: Breaker-and-a-half diameter with protection and control In the following, we will look at the voltage selection for the synchrocheck in the 6MD86 bay controller. This selection is based on the position of the switching devices which are evaluated using the CFC chart. Figure 4 shows the configuration of the voltages to the inputs of the function group "circuit breakers" and Figure 5 shows an example of a CFC chart for selecting the voltage. Figure 4: Assigning the voltage inputs to the function groups SIP5-APN-012 6

Figure 5: Voltage selection in the "circuit breaker" function group Figure 6: CFC chart for voltage selection The voltage inputs are numbered consecutively in the device (see Figure 4: ID2-5). In the CFC chart, this number is assigned to the corresponding inputs (see Figure 5) depending on the switch positions. In the example of the breaker-and-a-half application, the input Vsync1 is always permanently connected to the voltage of ID4, while the CFC chart makes the selection for the input Vsync 2 based on the switch position. The voltages with the IDs 2, 3 and 5 are available for this purpose. 7 SIP5-APN-012

1.3.2 Double busbar with switchgear interlocking protection The double busbar shown in Figure 6 is controlled by one 6MD85 bay controller. The device additionally operates as Phasor Measurement Unit (PMU). Figure 7: Double busbar with bay controller This paragraph describes the switchgear interlocking protection of the bay. Moreover, the configuration of the Phasor Measurement unit in the bay controller is discussed. Other functions such as synchrocheck of the circuit breaker, protection function or measured value processing are possible. Switchgear interlocking protection The switchgear interlocking protection can be divided into bay-related switchgear interlocking protection and cross-bay switchgear interlocking protection. The bay-related switchgear interlocking protection only requires information that is available in the bay controller itself. The cross-bay switchgear interlocking protection also requires information from adjacent bays, for example concerning the switching status of the bus coupler. Such information is exchanged between the devices using the IEC 61850-GOOSE communication link (Figure 8). SIP5-APN-012 8

=C01 =C02 =C03 6MD85 6MD85 6MD85 Busbar disconnector closed Busbar disconnector closed Coupler closed Figure 8: Communication between multiple bays to exchange information regarding the switchgear interlockings The required interlockings are created in CFC. Figure 8 shows the resulting chart in the device for feeder bay C01. You can see the query of the indication "coupling closed" from device C02 in the coupling as additional release for the busbar disconnector (these can then be opened or closed). 9 SIP5-APN-012

Figure 9: Switchgear interlocking for busbar disconnectors and circuit breakers 1.3.3 Phasor Measurement Unit (PMU) Synchrophasors are perfectly suited to monitor the dynamic power system behavior. This function can be activated in the SIPROTEC 5 devices; an Ethernet communication module is required for this purpose. Select the communication protocol "Synchroph./PMU" on this module. For bay controllers this will typically be a second communication module (in addition to the module required for the substation automation system protocol). This module for PMU communication transmits the synchrophasors to a phasor data concentrator such as SIGUARD PDP via the IEEE C37.118 protocol where they are archived and evaluated (Figure 9). SIP5-APN-012 10

Figure 10: SIPROTEC 5 bay controllers as PMU in a wide area monitoring system By selecting the protocol "Synchrophasor/PMU", a PMU function group is created in the device which is, however, not displayed in DIGSI. This is due to the fact that all required parameters are available in the channel settings of the protocol (Figure 11). Figure 11: Configuration of the PMU in DIGSI 11 SIP5-APN-012

Fehler! Verweisquelle konnte nicht gefunden werden. Published by and copyright 2013: Siemens AG Infrastructure & Cities Sector Smart Grid Division Humboldtstr. 59 90459 Nuremberg, Germany Siemens AG Infrastructure & Cities Sector Smart Grid Division Energy Automation Humboldtstr. 59 90459 Nuremberg, Germany www.siemens.com/protection Printed on elementary chlorine-free bleached paper. All rights reserved. If not stated otherwise on the individual pages of this catalog, we reserve the right to include modifications, especially regarding the stated values, dimensions and weights. Drawings are not binding. All product designations used are trademarks or product names of Siemens AG or other suppliers. If not stated otherwise, all dimensions in this catalog are given in mm. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. For more information, please contact our Customer Support Center. Tel.: +49 180 524 8437 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.ic@siemens.com Application note: SIP5-APN-012 SIP5-APN-012 12