Description, continued

Similar documents
HC900 Remote Termination Panel (RTP) For Relay Outputs

Model T28 Transmitter

Push-Pull and E-Stop Switches. Datasheet

NN1 PH1 CC1 DM1 DB1. TABLE V - Options. Mounting Hardware. Instruction Books NN2 PH2 CC2 DM2 DB2. Certificates. PID Control NN C3.

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

+GF+ SIGNET ph/orp Transmitter Instructions

OPERATION MANUAL MODEL TT-LP

Controllers, Indicators & Set Point Programmers

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Solutions to the Most Challenging Environments

Distributor: Topac Inc 231 CJC Highway Cohasset MA Tel Fax

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Contents. 1. Installation

High Voltage DC Meter

Hanna Instruments HI9819X Multiparameter series

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

SIGNET ph/orp Transmitter

HIGH-VOLTAGE DC METER

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

LCI User Manual mantracourt.com

KOBOLD TDA Series Digital Temperature Transmitter

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Conductivity Transmitters

DEVAR Inc. Model d-rtti User Manual

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Universal power supply

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

MICRO SWITCH Sealed Subminiature Basic Switches. ZW Series. Datasheet

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Level-Lance Model 5400A

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

portable waterproof multiparameter meter

HI 9828 Multiparameter Water Quality Meter...

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

Industrial Wet/Wet Differential Pressure Transducer

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

LCI Load Cell Junction Box with Fault Monitor

Plug & Play Analytical Solutions Making Basic Measurements Easy

Global Water globalw.com. Global Water. Instrumentation, Inc.

Installation Guide MODELS 522 / 526. Pressure Transducers TOLL FREE FAX Web Site.

BTU 4 & Sensors. Installation and Operation Manual

Global Water Instrumentation, Inc.

Instrumentation for Process Analytics

Component identification

ivu TG Gen2 Image Sensor with Integrated Display

SMART Position Sensor, 100 and 180 Arc Configurations

Professional Waterproof Meters

Technical Note Series

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Model Q45H/64 2-Wire Dissolved Ozone Transmitter

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

How to build a Conductivity Measurement System

FLS M9.06. ph/orp MONITOR

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

HI 9828 Multiparameter Water Quality Meter...

200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

KOBOLD PDA Series Digital Pressure Transmitter

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

BusBlock Analog Input Module for the Smart Distributed System

WLS28-2 Dual Color LED Strip Light

MODEL 245 / 345 High Range

IRRIGANDER 4 SPLITTER SWITCH

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

Signet ph/orp Transmitter * *

MICRO SWITCH Military-Grade Toggle Switches. TL Series. Datasheet

T80 Universal Transmitter S80 Intelligent Sensors

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

MICRO SWITCH Military-Grade Toggle Switches TL Series Issue 4. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Torque Thrust Transducers Model Issue 1. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION PORTFOLIO VALUE TO CUSTOMERS

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

Humidity goes Digital

Rotary Switches. Datasheet

With this sensor, Honeywell has utilized MR technology through the ASIC at a level never before accomplished.

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

American Power Design, Inc.

MODEL 692E TWO-WIRE ELECTRODELESS CONDUCTIVITY TRANSMITTER

Model Q45P External DC Power ph Transmitter

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

CDD4 Duct Carbon Dioxide Transmitter

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Tempco Instruction Manual

Honeywell Model 700/800 Signal Processor and Viewing Head

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

MODEL 692P TWO-WIRE ph TRANSMITTER. Manual No. 692P Revision 9-898

Transcription:

DL424/425 DirectLine Sensor Module for DL5000 Dissolved Oxygen Probes Overview 70-82-03-48 4/02 Page of 8 Specification The DirectLine DL424/425 Sensor Modules are part of a family of products developed by Honeywell as part of a new generation of analytical instruments. The unique architecture of the DirectLine module combines the latest in microelectronics technology with the proven performance of Honeywell s DL5000 dissolved oxygen equilibrium probe to provide unequaled savings during installation, start-up, operation, and maintenance. The DirectLine electronics module can be mounted integrally or remotely on the DL5000 probe. It provides a 4-20 ma dc output proportional to dissolved oxygen. The output of the DirectLine sensor connects directly to any host monitor or control device that accepts standard 4-20 ma inputs and provides external loop power including: Honeywell UDC3300 /4-DIN Controller UMC800 Controller PLCs with analog inputs DCS systems A host of other recorder/controller products Description The Honeywell DirectLine architecture consists of an electronics module integral to a sensor or probe. This design eliminates the need and added cost of a separate analyzer or transmitter. The electronics module is sealed in a plastic weatherproof, corrosionresistant housing and is connected to the DL5000 dissolved oxygen probe on one side and a 4-20 ma output cable on the other via waterproof connectors. This housing design allows this system to be used in harsh environments where moisture and dust is a problem. Figure DirectLine DL424/425 Sensor Module Description, continued For submersion or special mounting applications, a remote mounting option is available which connects the electronics module to the DO probe via a cable. The module can be mounted on a 2-inch pipe, wall or DIN rail. Features Direct 4-20 ma output eliminates need for dedicated analyzers or transmitters, simplifying installation, start-up, operation, and maintenance tasks. Installation costs are also reduced since standard cable can be used for additional cable distances. Integral electronics with local HMI simplifies installation and shortens calibration times. Plug-in modular design allows probe to be safely removed and replaced without cycling power on the electronics module. Features, continued Local display and keypad facilitates quick set-up, calibration, and operational activities. Electronics and probe diagnostics reduces troubleshooting times. Air and sample calibration options accommodate individual calibration techniques and reduces calibration time. Playing card-sized guide facilitates simple, correct, and consistent calibration and configuration. Watertight sensor connection for reliability in submersion applications. Global approvals including: UL General Purpose CSA General Purpose IP66 Enclosure Industrial Process Control, 00 Virginia Drive, Fort Washington, PA 9034 Printed in U.S.A. Copyright 2002 Honeywell

Page 2 Electronics Module Integral Electronics/Sensor Design The DirectLine electronics module is loop-powered by 6-42 Vdc source and will modulate its supply current from 4-20 ma, depending upon the DO value sensed by the DL5000 probe. The output cable connects to the electronics module by a waterproof connector. The DirectLine sensor s output cable is a standard shielded twisted pair, which allows additional wiring to be added at minimal cost and time. The output cable length is available in either 20-ft. or 50-ft. lengths with tinned leads for easy connection by the customer. The DL424/425 module quickly attaches to the probe and is easily locked-in-place for assured safety and reliability during operation. The probe can be removed from the module safely without disrupting power to the electronics. Submersion Applications For submersion or special wiring applications, a remote electronics module option is available. The remote electronics module can be mounted on a 2-inch pipe, wall, or DIN rail. The remote probe cable is supplied with the DL5000 probe. It directly connects the electronics module to the probe with a submersible connector. Operator Interface The DirectLine electronics module configuration, calibration, and maintenance functions are performed locally from three buttons and a 4- digit, 7-segment LCD display on the front side of the electronics module. The process variable, temperature (if available), and any error diagnostics are viewable from the local LCD display. The following configuration functions are available. New Probe Reset Air Calibration Sample Calibration Atmospheric pressure Compensation Salinity Compensation (ppm only) Probe Bias Voltage Output configuration Noise suppression frequency selection The Honeywell DirectLine sensor eliminates the extra time needed to travel back and forth between the analyzer/transmitter and probe location while performing a calibration. The DL424/425 offers two calibration options: Sample and Air calibration. A playing card-sized guide comes with each DirectLine sensor to guide you through a configuration or calibration quickly. Online Diagnostics The DirectLine sensor continuously performs self-diagnostics on both the electronics and sensor. These prioritized self-diagnostics help to minimize the time and expense of troubleshooting during start-ups, maintenance, and calibrations. If a problem arises with either the module electronics or the sensor, the software prioritizes the problem type and displays only the highest priority error diagnostic thus simplifying the troubleshooting process. Once the diagnostic is corrected, the error code disappears from the display. Online Diagnostics, continued If the electrode s temperature or process variable value goes out of operation range, the output current is driven to approximately 2.8 ma to inform the host device of a problem. Once the problem is corrected, the output current is returned back to normal and the error code disappears. Error codes are also used to indicate calibration failures. DL5000 DO Probes DL5000 dissolved oxygen probes are based on a unique equilibrium probe technology which results in a probe which is: Unaffected by fouling or changes in sample flow Requires no periodic replacement of anode or electrolyte Features a heavy membrane which eliminates replacement requirements Available in PVC and stainless steel housings; ppm or ppb configuration; integral and remote mountings The DL5000: can be mounted using immersion, insertion or flow-through mountings measures and displays temperature as well as dissolved oxygen concentration

Page 3 Specifications Displayed Process Variable Displayed Temperature Range DL424: 0-20 ppm dissolved oxygen in ppm increments; DL425: 0-200 ppb dissolved oxygen in and 0 ppb increments 2.0 to 60.0 ºC (35.6 to 40ºF) Operating Temperature 20 C to +60 C (-4 F to +40 F) Storage Temperature DL424/425 Output Accuracy with DL5000 Probe DL424/425 with DL5000 Probe Measurement Response 20 C to +70 C (-4 F to +58 F) ppm: +/- 0.2ppm after stabilization ppb: +/-2ppb or 5% of reading after stabilization, whichever is greater 90% of value in minute (after probe warm-up) Display Resolution DL424: 0.0 ppm DL425: 0. ppb in the 0-20 ppb range; ppb in the 0-200 ppb range Output Type 4-20 ma (2-wire loop powered) Output Calibration Power Calibration Options Diagnostics 4-20 ma 6-42 Vdc Maximum Load Resistance: Air ; Sample Cal Sensor and electronics 250 ohms at 6 Vdc 600 ohms at 24 Vdc 400 ohms at 42 Vdc Physical Properties: Case Weatherproof, corrosion-resistant plastic housing Local Display and Buttons LCD 4-digit, 7-segment Output Cable Type Shielded twisted pair Output Cable Length: 20 feet or 50 feet User Termination Tinned leads Remote Mounting Pipe, Wall, or DIN Rail Dimensions H 23 mm (4.84 ) x W 48 mm (.89 ) x D 46 mm (.8 ) Weight Approximately 42 g (5.0 oz.) Approvals UL General Purpose CSA General Purpose IP66 Enclosure

Page 4 Dimensions Integral Mounting 48 mm.9 in. M O D E 2 95 mm 3.75 in. Electronics Module Front View Locking Screw in Rear of Housing 46 mm.8 in. Probe Side View Figure 2 Dimensions Figure 3 Integral Mounting of Electronics Module with DL5000 DO Probe

Page 5 Remote Mounting Electronics Module M O D E 2 2 3 4 5 6 DL5000 Probe Electronics Pigtail Shield (Black/White) Temperature Compensation (Orange) Temperature Compensation (Yellow) Anode (Red) Reference (Green) Cathode (Black) Earth Ground (Blue) Protective Vinyl Boot (remove) 6 5 4 2 3 Cover Strain Relief Compression Cap Remote Wiring Cable 20 Feet Probe Figure 4 Remote Mounting of DL424/425 Sensor Module with DL5000 Dissolved Oxygen Probe

Page 6 Remote Mounting Hardware Hose Clamp Slot for Pipe Mounting (Hose Clamp included in kit) Through Hole Through Hole for DIN Rail Mounting Metal clip for U DIN rail mounting Gray clip for G DIN rail mounting Mounting Kit View from End View from End Panel Panel Terminal Connectors Barriers, Repeater, Isolators Front View Front View U Style DIN Rail G Style DIN Rail Figure 5 Remote Mounting Hardware

Page 7 Instructions Select the desired key number. The arrow to the right marks the selection available. Make the desired selections from Table I using the column below the proper arrow. A dot ( ) denotes availability. No ( ) dot denotes not available. Key Number I II III _ - _ - _ - _ - IV Model Selection Guide Key Number - DirectLine TM Sensor Electronics Module (Specify electrodes, probes/cells separately) Selection Availability Stocking P/N ph For use with Durafet II, Meredian II & HPW7000 ph electrodes. DL42 5500259-00 ORP For use with ORP electrode. DL422 5500259-002 Conductivity For use with Contacting Conductivity Cells DL423 5500259-003 Dissolved Oxygen - PPM For use with Dissolved Oxygen ppm Probes DL424 5500259-004 Dissolved Oxygen - PPB For use with Dissolved Oxygen ppb Probes DL425 5500259-005 TABLE I - OUTPUT CABLE Output Cable for No cable required (replacement modules only) A c c c c c N/A Integral or Remote 20 Ft. of output cable B 550027-00 Mounting 50 Ft. of output cable C 550027-002 TABLE II - SENSOR CABLE/REMOTE CONNECTOR Integral Mounting Remote Mounting Cable No cable or connector required - Durafet II, Meridian II, Contacting Conductivity and Dissolved Oxygen 20 Ft. of sensor cable - Durafet II Remote Mounting 0 d e d d d d N/A 2 5500270-00 (Durafet only) 50 Ft. of sensor cable - Durafet II Remote Mounting 2 e 5500270-002 Remote Mounting Connector - Meredian II ph 3 e 5500768-00 Remote Mounting Remote Mounting Connector - Meredian II ORP 3 e 5500768-002 Connector (Cable supplied Remote Mounting Connector - HPW7000 4 e 5500768-003 with sensor or probe) Remote Mounting Connector - Conductivity 5 e 5500768-004 Remote Mounting Connector - Dissolved Oxygen 6 e e 5500768-005 TABLE III - REMOTE MOUNTING OPTIONS Mounting Kit for remote None Integral unit - mounting not required A N/A 2 Mounting 2" Pipe mounting bracket, wall mounting, & DIN Rail clip B 5500526-00 TABLE IV - OPTIONS Tagging Certificates None 00 N/A 2 Linen Customer ID Tag - 3 lines w/22 characters/line LT N/A 2 St. St. Customer ID Tag - 3 lines w/22 character/line SS N/A 2 None 00 N/A 2 Calibration (F3399) CA N/A 2 Conformance (F339) C0 N/A 2 Calibration & Conformance CC N/A 2 Notes:. Electrodes, Probes & Cells must be specified separately: For electrodes & available mountings see: MSG DL000 for Durafet ph, DL2000 for Meredian II, DL3000 for ORP, DL4000 for Contacting Conductivity and DL5000 for Dissolved Oxygen Probes 2 N/A=Not available via stocking part numbers. Order by model number. RESTRICTIONS Restrictions Letter c d e Available Only With Table Selection II 0 III A III B Table Not Available With Selection ORDERING INSTRUCTIONS:. Part numbers are provided to facilitate Distributor Stock. 2. Orders may be placed either by model selection or by part number. 3. Part numbers are shown within the model selection tables to assist with compatibility information. 4. Orders place by model selection are systematically protected against incompatability. 5. Compatibility assesment is the responsibility of the purchaser for orders placed by part number. 6. Items labeled as n/a are not available via the stocking program and must be ordered by model selection.

Page 8 Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Distributor : For more information, contact Honeywell sales at -800-343-0228. Industrial Process Control Honeywell 00 Virginia Drive Fort Washington, PA 9034 70-82-03-48 0402 Printed in USA www.honeywell.com/ipc