Instructions for Installing the ShopBot 3- Button Pendant Retrofit for PRT/PRSalphas

Similar documents
Control Box Setup - PRSalpha

Installing 6 Indexer: PRS Standard Tools

CNC Router Parts. Plasma Upgrade Kit. Installation Instructions Version 2016Q3.1

Installing a Power over Ethernet injector

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

M215 (M215-60) Safety

Service Bulletin. MiTek. RoofTracker Roof Truss Roller Press. Machinery Affected: Adding an Operator Platform. Machinery Division

Replacing the Power Supply

3 Indexer Installation For PRSalpha Tools

Removal and Installation8

Plasma Retrofit Guide Upgrade Kit Installation Instructions

To connect the AC adapter:

Royal RVV-500 (B) Retrofit Kit

SERVICE INSTRUCTIONS CONVERT OLD SFC TO NEW SFC WARNING WARNING WARNING

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

Series 3700 Screw Terminal Assemblies Installation Instructions

M250 (M LL) Safety

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Upgrading to a RBK Control Box

Megatouch FORCE Monitor Chassis Board Replacement

E1135C PDU and Pod Upgrade Procedure

M215-Z Safety Information (M LL-IG-ZC)

Removing and Replacing Parts

INSTALLATION INSTRUCTIONS. This document describes the installation procedures for the TMM-441 Touchscreen Master Module.

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

A-dec 584 Monitor Mount on a Central Cabinet

Installation and Start-Up Instructions

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

JAN 16 Rev B

Installation Instructions

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

IMPORTANT AS YOU REMOVE THE CONNECTORS LABEL THE CONNECTOR WITH THE NAME OF PLUG WITH THE SHARPIE

Written By: John Sutton

Model No. ET-JPF200BE

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual

Replacing the Gateway M405 Keyboard

ColorMaxLP Label Roll Rewinder

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

Printhead alignment. 1. Turn the printer off. 2. Remove the top cover. See Additional information top cover removal on page 8.

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

Service & Maintenance

InView Communication Modules

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

This Datasheet is for the IC693MDL /24 Volt DC, 0.5A Positive Logic Output, 32 Point.

INSTALLATION INSTRUCTIONS

Dell Latitude C800 Service Manual

System Storage EXP3000 Rack Installation Instructions

Register your product and get support at CEM2000. Quick Start Guide

PM Series Power Meter

CARD PRINTER PRINTHEAD REPLACEMENT INSTRUCTIONS

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Marina HDMI Install Instructions

Peel/Rewind Upgrade Kit

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual

HD Flex Zero RU Cassette Holder and Bracket

Quick Installation Guide

PACSystems* RX3i IC695ACC650

HL-DL. Direct View Architectural Delineation LED System INSTALLATION GUIDE

Procedure to Replace a TCD DPM with an IS TCD DPM in a Maxum or Maxum II Analyzer

Installation Instructions

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

Procedure to Upgrade from SYSCON+ to SYSCON2 and Implement Release 5.0 in a Working Maxum Network Access Unit (NAU)

Canon EOS Rebel T2i Top Cover Replacement

Installation Instructions

Chore-Tronics IDM Board Instruction

2017 TigerStop,LLC. Printer. February 2017 Mk1

Gateway Profile 4 service guide

Software Installation Guide

Replacing the Gateway M305 Optical Drive

LCD Meter for Model 3051 Pressure Transmitters English Rev. AA

AC LEISURE PRO SHORE COMMANDER

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Quick Installation Guide

DST550 Digi-Stem Thermometer

PS/IO Circuit Board Retrofit

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

Replacing the Gateway M275 Keyboard

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

FR-A8AR INSTRUCTION MANUAL

LED Maintenance Instructions

Print Mechanism Maintenance Kit

edrive RAM Battery Alternate Replacement Procedure

Made In America 2017 TigerStop, LLC. Tablet Package. Installation Guide. February 2017 Mk1

Keypad Lock. Operation and Service Manual. Order parts online

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2

MacBook Core Duo Left I/O Frame Replacement

641G-001A PRINTER KIT INSTRUCTIONS

ReachFree ID Installation Instructions for Wash Select II. Unitec

Replacing the TFM coupler

EASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations

Mac mini Mid 2011 Heat Sink Replacement

Assembly and Operating Instructions Door Control

Enphase S-Series Microinverter and Engage Cable Safety

AFCS Fluid Guard 2 Model

MobileView Junction Box

Manual No: Revision: D. Mag Retrofit Probe. Installation Guide

ILC LightLEEDer MicroLite 1000P Retrofit Installation

Transcription:

Installing the 3-Button Pendant Retrofit Page -1- Instructions for Installing the ShopBot 3- Button Pendant Retrofit for PRT/PRSalphas The 3-Button Pendant can be added to PRS/PRT alpha ShopBots and can be placed in a convenient location to allow ready access to the Start, Reset and E-Stop. The buttons on this pendant work in addition to the exising Start, Reset and E-Stop. The 30ft cord allows the operator to carry it to virtually any location around the table or it can be mounted near the computer controlling the ShopBot. Only alpha models can use this retrofit. ShopBot Tools, Inc 3333B Industrial Dr Durham, NC 27704 919-680-4800 or 888-680-4466 www.shopbottools.com

Installing the 3-Button Pendant Retrofit Page -2- WARNING ELECTRIC SHOCK CAN KILL Use extreme caution when working near live electrical circuits. Dangerous voltages exist inside the control box that can cause serious injury or death. Always use safe practices and good judgment. Installation The 3-button pendant can only be wired into alpha control boxes produced prior to February 2008. The pendant has 6 twisted pairs of colored wires (12 total) that will be used to wire in the device. These twisted pairs will be bundled for 3 areas: Start Button: Green / Black twisted pair Reset Button: Yellow / Black twisted pair Brown / Black twisted pair Blue / Black twisted pair E-Stop: White / Black twisted pair Red / Black twisted pair

Installing the 3-Button Pendant Retrofit Page -3- Before installing the 3-button pendant, make sure all power has been disconnected going into the ShopBot control box and to the spindle/router. Removing the Existing Reset and Start Button Switch Housings Removing the switch housings makes it easier to install the wiring. Open the control box door. Look into the upper left corner of the box and find the switch housings for the Reset and Start buttons. These have a snap-in connector that is released by moving the release switch towards the front of the box. With the release switch depressed to the front, the switch housing will pull out toward the interior of the control box. Remove both the Reset (front of box) and Start (back of box) button switch housings. Routing the Cable from the Pendant into the Control Box On the right side of the control box is the Roxtech cable management system. Using a screw driver in the upper hole of this system, rotate the block upward to release the cam tension of the block. Route the cable from the 3-button pendant into the control box. Leave the Roxtech system open until everything has been wired in.

Installing the 3-Button Pendant Retrofit Page -4- Connecting the Wires from the Pendant In most instances it is not necessary to remove the preexisting wires from the Start and Reset buttons. If these are removed, be careful not to lose the white labeling tags that mark these wires. Wiring into the existing start button Locate the Start button bundle: Green / Black twisted pair from the 3-button pendant and Start button (closest to back of control box). With a screw driver, loosen the terminal on the top of the button. Insert the Green wire from the Green/Black twisted pair into the terminal. Both the Green wire and ST1 will be shared in this terminal. Tighten securely. Loosen the terminal on the bottom of the button. Insert the Black wire from Green/Black twisted pair into the terminal. Both the Black wire and ST2 will share this terminal. Tighten securely. Refer to wiring diagram on last page if needed.

Installing the 3-Button Pendant Retrofit Page -5- Wiring into the existing Reset Button Locate the reset button bundle (Yellow/Black twisted pair, Brown/Black twisted pair, and Blue/Black twisted pair) from the 3-button pendant and Reset button (closest to front of control box). With a screw driver, loosen the terminal on the top left of the button. Insert the Yellow wire from the Yellow/Black twisted pair into the terminal. Both the Yellow wire and RX2 will share this terminal. Tighten securely. Loosen the terminal on the bottom left of the button. Insert the Black wire from Yellow/Black twisted pair into the terminal. Both the Black wire and RX1 will share this terminal. Tighten securely. With a screw driver, loosen the terminal in the top middle of the button. Insert the Blue wire from the Blue Black twisted pair into the terminal. Both the Blue wire and RX6 will share this terminal. Tighten securely. Loosen the terminal in the bottom middle of the button. Insert the Black wire from Blue/Black twisted pair into the terminal. Both the Black wire and RX5 will share this terminal. Tighten securely. With a screw driver, loosen the terminal on the top right of the button. Insert the Brown wire from the Brown/Black twisted pair into the terminal. Both the Brown wire and RS1 will share this terminal. Tighten securely. Loosen the terminal on the bottom right of the button. Insert the Black wire from Brown/Black twisted pair into the terminal. Both the Black wire and RS2 will share this terminal. Tighten securely. Refer to wiring diagram on last page if needed.

Installing the 3-Button Pendant Retrofit Page -6- Wiring into the existing E-Stop Locate the E-Stop bundle (White/Black twisted pair and Red/Black twisted pair) from the 3-button pendant and the blue E-Stop terminal block which is found on the control board. Remove the Blue terminal block from the control board. Orient the wires from the E-Stop so that the White wire is in the 2nd terminal from the left (ES2) and the Green wire is in the 3rd terminal from the left (ES3). Remove the Red and Black wires from the terminal block. Place the Black wire from the Red/Black twisted pair into the 1st terminal on the left (ES1). Place the White wire from the White/Black twisted pair in to the last terminal from the left (ES4). Crimp together the remaining Red wires and then the remaining Black wires. Refer to wiring diagram on last page if needed.

Installing the 3-Button Pendant Retrofit Page -7- Reinstalling the Existing Buttons and E-Stop Reinstall the Reset and Start buttons in the upper left corner of the ShopBot control box. Reinstall the E-Stop s blue terminal block back onto the control board. Securing the Cabling Make sure that there is adequate amount of slack left inside the control box for the 3-button pendant. This will mean that no connection is under any strain; use wire ties if needed. Secure the cable from the 3-button pendant in the Roxtech cable management system (See Routing the Cable). Using a screw driver in the upper hole of this system, rotate the block downward to apply pressure on the spacers.

Installing the 3-Button Pendant Retrofit Page -8- Testing the 3-Button Pendant Now that the 3-button pendant is wired, it is now time to test the button system. Both the newly installed 3-button pendant and the existing buttons and E-Stop need to be tested to ensure all connections are working properly. Test the buttons on the new pendant Close the ShopBot control box and reconnect the power to the control box and spindle/router. Turn on the switch on the front face of the control box. Press the Reset button on the pendant and listen for the contactors in the control box to engage. Type K (Keypad) in the ShopBot control software and turn on output #1. Press the Start button on the pendant. The spindle should come on. Hit the E-Stop on the 3-button pendant. This should kill power to the control box. If any of these procedures failed, recheck the wiring diagram on page 6. Test the existing buttons Close the ShopBot control box and reconnect the power to the control box and spindle / router. Turn on the switch on the front face of the control box. Press the Reset button on the side of the control box and listen for the contactors inside to engage. Type K (Keypad) in the ShopBot control software and turn on output #1. Press the Start button on the side of the control box. The spindle should come on. Hit the E-Stop previously installed. This should kill power to the control box. If any of these procedures failed, recheck the following wiring diagram.

Installing the 3-Button Pendant Retrofit Page -9-