Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

Similar documents
Square D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions

Square D Homeline Load Centers and Circuit Breakers. Engineered for value

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Illinois and Northwest Indiana Metering Equipment

The Leviton Load Center THE FUTURE MADE CURRENT

Power Mod. Introduction and Contents. Revised 02/18/14

Meter Enclosure and Equipment Standards

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.

The Leviton Load Center THE FUTURE MADE CURRENT

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Powering innovation. Powering efficiency. Powering home

Power-Style QED-2, Series 2 Low Voltage Switchboards

SECTION PANELBOARDS

Help protect your home, possessions, and family.

US CATALOG. SENTRICITY Load Centers and Circuit Breakers Raising the standard in residential.

SECTION DISCONNECT SWITCHES

SECTION SWITCHBOARDS

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Residential Renovation Loadcenters and Accessories

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

PowerLogic High Density Metering System 1-Meter Enclosure

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

Elastimold Molded Vacuum Recloser - MVR

ICS Entrance Management Sign Installation Guide. Version 1.0

Series Amp Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

IS-DM220/IR/HB IS-DM220

Surge Protection V1-T2-2 V1-T2-2 V1-T2-3 V1-T2-4. Learn Online

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

DC Outdoor Power Supply/Chargers

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

The Center of Automation with IEC Products. CENTERLINE Motor Control Center. Allen-Bradley Replacements

Type 4X S.S. Disconnect Enclosures

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

CONGRATULATIONS!! You have given yourself the power & flexibility needed in today s ever-changing exterior environment. Got Lights?

Backpanel Attaching Hardware. Molded-in Threaded Housing for Mounting. Enclosure. Enclosure. Backpanel. Fuse Holder with Series Fuse

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

Application Techniques CENTERLINE 2100 Motor Control Centers

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Illustrated Parts List. Generator Systems. Reproduction MODEL Not for. 12,000 Watt. Generator Systems

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. 4. Electronic-grade panelboards.

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

From houses to high-rises

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Innovative POWER Solutions

Figure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.

Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

TYPE 4/12 PREMIER SERIES

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

SECTION WIRING DEVICES

DTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications

Nevco Outdoor LED Scoreboard Installation Manual

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

AlphaGateway SMG-01PE Quick Start Guide

EJB Junction Boxes Dimensions Pg. 132

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

FT Flexitest Family. Switches, Covers and Test Plugs

120 VAC 14x12x7 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fan and Solid State Fan Controller Model: NB FS

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features

Commodore SS Model CD General Specifications

Self Contained - Non-Jaw Clamping Lever Bypass

Secondary Surge Arrester Instruction Manual Page 1 of 5

Illustrated Parts List MODEL. Reproduction Not for. 8,000 Watt Generator Systems

4C Standard Horizontal Mailboxes

Nevco Indoor LED Scoreboard Installation Manual

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

US 5,634,357 D 385,7683 Bulletin: A28S4

Featuring Spectra RMS Breakers

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Self Contained - Non Lever Bypass

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate. Model: NB Applications and Features

Illustrated Parts List MODEL. Reproduction Not for. 8,000 Watt Generator Systems

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices

ASCO 920 Remote Control (RC) Switches

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

CONCEPT Stainless Steel Wall-Mount Enclosures

Power Supply (48Vdc, 2.5A)

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Type 4 Disconnect Enclosures

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

SECTION SWITCHGEAR

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Installing the DX LCD Display

Transcription:

Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions

VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry. And reliable, proven performance. These major benefits of Square D Meter Centers address the needs of electrical contractors, utilities, and their customers in multi-unit housing and light commercial applications. Square D UL-Listed indoor or rainproof MP METER-PAK and EZ METER- PAK Meter Centers offer ideal solutions for all your multimetering applications. For 2- to 6-unit apartments, MP METER- PAK Meter Centers give you the most reliable and easiest to install metering devices available. If you have metering applications which require multiple meter sockets, or where a main device is used for the incoming service, EZ METER-PAK Meter Centers offer the optimum in system flexibility, quality performance, and ease of installation. Key benefits of the Square D Meter Center family include: Ready for mounting right out of carton, with no disassembly or adjustment Time-saving installation features, including a separate mounting channel and swingable mounting brackets 9" centers on 125A and 200A devices to allow more sockets per branch device, reducing the need for branch devices and overall wall space Compact, lighter weight enclosures with ample wiring space to simplify installation and handling A full line of metering devices to meet EUSERC requirements Factory bussing with Belleville washers on all electrical connections to ensure high integrity Meter socket combinations with horn bypass, no bypass, or lever bypass and 4-, 5-, or 7-jaw configurations to meet a wide range of applications Tin-plated copper, spring-reinforced meter socket jaws for long-lasting performance Sealing provisions designed to meet utility sealing requirements, including stainless steel cover hasps for long-lasting security in corrosive environments. 2

Leading the way with metering solutions The Square D exclusive double-headed VISI-TITE Nut eliminates the need for special tools or time-consuming torque readings. When these double-headed nuts are tightened, the outer head twists off at the proper torque for the connection, leaving a single nut for future maintenance. A red indicator remains in position until the outer head twists off. Installation is simplified by several key features. Mounting methods include a separate mounting channel and rotating mounting feet to simplify mounting, drilling, and anchoring. No disassembly is required to reposition and the device does not have to be moved to drill into mounting holes. A swing-up rain channel also provides easy access to the enclosure during wiring. Phase balancing of networked metering applications is essential to ensure proper system functioning and prevent transformer overloads. EZ METER-PAK Meter Centers provide this level of protection by leaving the factory phase balanced to meet typical job requirements. This design also allows individual meter socket phase balancing when required. 3

EZ METER-PAK METER CENTERS Square D EZ METER-PAK Meter Centers are available from one to six high meter-breaker units. Greater selectivity means faster, easier installations. Plug-on QO two-pole circuit breakers are used in 125A units, while 200A residential units use factory-installed Q2 two-pole circuit breakers. 200A commercial devices use two- or three-pole QE circuit breakers. And 400A commercial applications utilize two- or three-pole LAL circuit breakers. Top and bottom wiring gutters with knock-outs allow branch circuits to exit from either the top, bottom, or back of the unit Meter-breaker units can be supplied with either 1-phase 3-wire, or 3-phase 4-wire service The main bus on residential units with 40A to 200A circuit breaker provisions is 800A, or 1200A in units using commerical 200A and 400A branch circuit breakers To suit individual applications, residential and commercial devices may be interconnected Basic devices for connection to 3- phase 4-wire 120/208Vac service are factory phase balanced to save installation time. The phase balancing may be modified in the field to meet most system variations 120/240Vac 1-Phase, 120/208Vac 1-Phase, 120/208Vac 3-Phase 1200A bussing available on all devices Meter sockets - 3-6 high stack available for 125A - 2-4 high stack available for 200A residential - 1-4 high stack available for 200A commercial - 1 and 2 high stack available for 400A commercial Ring and ringless style trims Factory-installed horn bypass and/or fifth jaw available for ringless devices Branch circuit breakers (40-400A) EUSERC devices available NEMA Type 3R for indoor or outdoor use Up to 100,000 AIC Lifting handles for EZM main device cover Crossbus closing cover is utility sealable for greater security Main devices for main circuit breaker, fusible switch or terminal box configurations: EZM mains are suitable for service entrance, and each can be top or bottom fed. Each main device can feed meter-breaker units from both sides, to suit the layout Swingable external mounting brackets: No disassembly is required to reposition the brackets or drill the mounting holes. This reduces installation time Combination overhead/underground feed 4

Individual meter socket covers available in ring or ringless styles Meter socket with front removable, springreinforced, tin-plated copper jaws 9" meter socket centers mean greater utility acceptance 5 Easy Steps 1. Draw guidelines and fasten mounting channel to the wall. Since the mounting channel is packed externally, the trims do not have to be removed before mounting. 2. Hang device on channel and position devices together. Swingable external mounting brackets quickly and permanently attach to the wall. 3. Remove device trims and bolt enclosures together. 4. Tighten VISI-TITE Nuts until outer head twists off. Branch circuit breakers: EZM utilizes Square D QO, Q2, LAL circuit breakers 5. Wire meter center and install trims. Powdercoat paint over galvannealed steel for long-lasting and durable finish Swing-up rain channel in all branch devices for ease of wiring Smaller, lightweight enclosures require less wall space 5

MP METER-PAK METER CENTERS Square D MP METER-PAK devices are available in two through six meter socket configurations. They re designed for use with QO twopole circuit breakers ranging from 40A to 125A and QOM2- MM branch circuit breakers ranging from 100A to 200A. 120/240Vac 1-Phase, 120/208Vac 1-Phase Bussing: 200A up to 800A 125A and 200A branch meter/breaker devices Ring and ringless style trims Factory-installed horn bypass and/or fifth jaw available on ringless devices Branch circuit breakers 40-200A Can be upgraded to meet EUSERC requirements NEMA Type 3R for indoor or outdoor use Combination overhead/underground feed with top hub provisions 9'' meter socket centers mean greater utility acceptance Small, lightweight enclosure for two to six meter socket positions Padlock clasp for circuit breaker cover door Individual meter socket covers available in ring or ringless styles Lifting handles for utility pull section cover (except on twoposition 125A device) 6 Stainless steel sealing and locking provisions for utility pull section covers

Powdercoat paint over galvannealed steel for a longlasting and durable finish Surface mount design, convertible to semi-flush with field-installed flange kit Factory-installed mechanical lugs (optional alternate lug kits and NEMA lug landing kits available) Meter socket with front removable, spring-reinforced, tin-plated copper jaws Uses Square D circuit breakers offering the highest level of protection on the market Swing-up mounting bracket for easy wiring 7

Square D: The Best In Electrical Protection. The comprehensive selection of Square D metering products is matched by a wide range of unsurpassed residential electrical distribution solutions. FPO Load Centers and Circuit Breakers Square D load centers and circuit breakers are designed for installation efficiency, superior reliability, and world-class quality in ISO registered plants. Our reputation is based on building the world s finest products and leading the industry with innovative features such as: Exclusive QWIK-OPEN protection on 15A and 20A single-pole circuit breakers that trip within 1/60th of a second. Exclusive QO VISI-TRIP indicators, which provide easy, visual identification of tripped circuit breakers. Ground Fault Protection Ground fault protection is required by code in many situations, and Square D GFCI branch circuit breakers are available to meet those needs. Oneand two-pole GFCI circuit breakers are available up to 60A for applications such as hot tubs and spas. SURGEBREAKER Secondary Surge Arrester The SURGEBREAKER Secondary Surge Arrester plugs on like a circuit breaker to help protect against surges up to 20,000 volts. SURGEBREAKER Plus Multi-Path Surge Arrester For whole-house surge protection, the SURGEBREAKER Plus Multi-Path Surge Arrester covers a home s electrical wiring, coax cable, and telephone lines. Arc-D-tect Arc Fault Circuit Interrupter The advanced technology of the exclusive Square D Arc-D-tect AFCI provides the highest level of circuit protection available today. These circuit interrupters are specifically designed to detect dangerous lowlevel arc faults and provide traditional overload and short circuit protection as well. This single-pole breaker installs as easily as our GFCI breaker and offers the same high level of reliability. FPO Air Conditioning Disconnects Square D air conditioning disconnects are used to provide overcurrent protection and a convenient shut-off for air conditioning compressors. They also can be used for other single-phase, two-wire disconnect applications. These disconnects are available in a variety of configurations, including molded case switches, pullouts, fused, and notfused. An exclusive mounting bracket is also available to simplify installation on stucco and lapped-siding projects. Square D,, QO, QWIK-OPEN, VISI-TITE and VISI-TRIP are registered trademarks of Square D Company. MP METER-PAK, EZ METER-PAK, SURGEBREAKER and Arc-D-tect are trademarks of Square D Company. Order Number 4100BR9801 02/99 Printed in U.S.A. 1999 Square D Company All Rights Reserved