IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3

Similar documents
November 2013 IEEE 802.3

November 2010 IEEE 802.3

Industry Standards Activity Overview

Atras Network Communications

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

LAN Standards, News & Trends Update 2017 June 15, 2017

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

LAN Standards, News & Trends. Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008

Optical Fiber Premises Standards News & Trends

History of Standards

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

Introduction to Key Principles of Telecommunications Cabling

AMENDED FINAL REPORT FOR:

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

ANSI/TIA/EIA-568-B Cabling Standard

NGBASE-T Cabling Requirements

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Certification for 10G copper cabling

Standards Update. by Paul Kish NORDX/CDT

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

Optical Fiber Networks: Industry. and New Options for Networks

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

IEEE Working Group November 2014 Plenary Week

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

1 of 5 12/31/2008 8:41 AM

Structured Cabling Organizations and Standards

AMENDED FINAL REPORT FOR:

Fiber backbone cabling in buildings

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

ProCurve Mini-GBICs. Used with the following

TIA TR-42 Liaison to IEEE

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

AMENDED FINAL REPORT FOR:

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions

Fiber in Data Centers What s Next? Srinivasan B, RCDD

The following pages contain a guide for the installation

IEEE GBASE-T Study Group Closing Plenary Meeting Report

Copper Cabling Standards

Fiber Optic Cabling Systems for High Performance Applications

IEEE P802.3bt Guidelines For Field Deployment

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

The Emerging Role of Single-Pair Cabling in Enterprise Networks

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Physical Layer Part 3

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

Anixter Standards Reference Guide

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

IEEE Working Group July 2018 Plenary Week

IEEE Working Group March 2014 Plenary Week. David Law Chair, IEEE Working Group Web site:

ISO/IEC TR Guidance on 40GBASE-T T Cabling

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond

CERTIFICATION PLUS SM

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

PANGEN SYSTEM WARRANTY. Warranty Guide

IEEE Working Group March 2018 Plenary Week

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture

Optical Fiber for Today s Premises Applications

THE OFFICIAL TRADE JOURNAL OF BICSI. November/December 2015 Volume 36, Number 6

Fiber Backbone Cabling in Buildings

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

Siemon PON Fiber Cabling Solutions

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

FTTE Revisited for New Technologies

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

IEEE Working Group Opening Plenary 9 th July 2018

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

Physical Layer Part 3

Cabling a Data Center to TIA-942 Standard

Siemon Interconnect Solutions

(Data Center Networks & Cloud Computing Security)

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Canadian Codes & Standards Updates

INTERNATIONAL STANDARD

EDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Balanced single-pair cabling channel specifications

Highlights: ISO/IEC SC25/WG3 Meeting Geneva: Sep Customer Premises Cabling -

Standardization Activities in International Electrotechnical Commission Technical Committee 86 (Fiber Optics)

Data Centers & Storage Area Networks Trends in Fiber Optics & Cabling Systems

Clause 86 MDI Optical Pin Layout and Connector. Paul Kolesar, CommScope Sharon Lutz, USConec IEEE P802.3ba January 2009

INTERNATIONAL STANDARD

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

IEEE Liaison report (Oct ) T v000 Tom Palkert, Macom

Cabling to Maximize n Wireless Performance

NGEAB-T Use Case ad hoc February 6, 2015

Wideband Multimode Fiber What is it and why does it make sense?

INTERNATIONAL STANDARD

IEEE P802.3ba 40 GbE and 100 GbE Standards Update

Application Note. Data Center Standards and Layouts

10 Gb/s Ethernet on FDDI-grade MM Fiber

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters

IEEE Working Group Interim meeting 17 th September 2015

IEEE GBASE-T T Study Group Agenda and General Information. Vancouver, BC January 9, 2003

Transcription:

IEEE 802.3 Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire The Siemon Company Dallas, TX November 9, 2015 Page 1

Introduction to TIA Telecommunications Industry Association www.tiaonline.org TR-42: Defines mechanical and transmission requirements for copper twisted-pair, optical fiber, and coaxial cabling and components Chris DiMinico is outgoing liaison from IEEE 802.3 to TIA TR-42 Page 2

Agenda and TIA Meeting Overview Most recent TR-42 Plenary week: October 12-16, 2015 in Denver, CO Review TR-42 subcommittee activities 10 subcommittees met Update on project development This symbol highlights key points of interest Page 3

2 TIA TR-42 Liaison Letters to IEEE 802.3 1. Draft 3.0 of TSB-184-A Guidelines for Supporting Power Delivery Over Balanced Twisted-Pair Cabling shared and available in the private area 2. Draft 0.1d of TSB-5021 Guidelines for the Assessment and Mitigation of Installed Cabling to Support 2.5GBASE-T and 5GBASE-T shared and available in the private area - Note that this is an early draft that has not been subject to the TIA public comment process Page 4

TR-42.1 (Commercial Building Cabling): ANSI/TIA-862-B, Building Automation Systems Cabling Standard approved for publication ANSI/TIA-568.1-D, Commercial Building Telecommunications Cabling Standard approved for publication New project: ANSI/TIA-5017, Telecommunications Physical Network Security Standard circulating for default ballot Page 5

TR-42.1 (Commercial Building Cabling), cont.: New project: ANSI/TIA-5018 Structured Cabling Infrastructure Standard to support Distributed Antenna Systems circulating for committee ballot New project: ANSI/TIA-1179-A Healthcare Facility Telecommunications Infrastructure Standard circulating for committee ballot New project: ANSI/TIA-942-B Telecommunications Infrastructure Standard for Data Centers under development Page 6

TR-42.5 (Terms and Symbols): Definitions, acronyms, units of measure, and symbols maintained in a working document New project: ANSI/TIA-440-C, Fiber Optic Terminology circulating for industry ballot TR-42.6 (Infrastructure Administration): New project: ANSI/TIA-606-B-1, Automated Infrastructure Management Systems circulating for industry ballot Page 7

TR-42.7 (Copper Cabling): New project: ANSI/TIA-1183-1, Test Fixtures for Balunless Measurements of Balanced Components and Systems to 2 GHz circulating for industry ballot New project: TSB-184-A, Guidelines for Supporting Power Delivery Over Balanced Twisted-Pair Cabling circulating for committee ballot (draft 3.0 available in the IEEE P802.3bt private area) Page 8

TR-42.7 (Copper Cabling), cont.: New project: ANSI/TIA-568-C.2-1, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, Addendum 1: Specifications for 100Ω Category 8 Cabling circulating for committee ballot (draft 3.2 available in the IEEE P802.3bq private area) 2-connector, 30-meter channels 2-connector, 24-meter permanent links Direct attach 1 MHz - 2 GHz frequency bandwidth Page 9

TR-42.7 (Copper Cabling), cont.: Class II channel performance criteria/limits documented The Class II task group is working to capture the category 8.2/class II transmission and electrical performance for cables, connectors, channel, permanent link, and patch cords as they exist in ISO 11801-1 now and present it to TR-42.7 for further guidance Page 10

TR-42.7 (Copper Cabling), cont.: New project: ANSI/TIA-1152-A, Requirements for Field Test Instruments circulating for committee ballot New project: TSB-5021, Guidelines for the use of Installed Cabling to Support 2.5GBASE-T and 5GBASE-T under development (draft 0.1d available in the IEEE P802.3bz private area) Page 11

TR-42.7 (Copper Cabling), cont.: New project: ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard opened (development to begin after ANSI/TIA-568-C.2-1 is approved for publication) New project: ANSI/TIA-568.4-D, Broadband Coaxial Cabling and Components Standard opened (development to begin after ANSI/TIA-568-C.2-1 is approved for publication) Page 12

TR-42.9 (Industrial Infrastructure): New project: ANSI/TIA-1005-A-x, Industrial cabling for one pair Link Segment Type B, 1000BASE-T1 including MICE 2 and MICE 3 under development New project: ANSI/TIA-1005-A-x, Performance requirements for four-pair industrial cables and cabling supporting 1000BASE-T for MICE2 and MICE3 environments under development Page 13

TR-42.10 (Sustainable Information Communications Technology) New project: ANSI/TIA-5011, Standard Process for Sustainable Information Communications Technology Manufacturers under development Page 14

TR-42.11 (Optical Fiber Systems): New project: ANSI/TIA-568.3-D: "Optical Fiber Cabling and Components Standard circulating for industry ballot New project: TSB-5040: "Understanding Duplex and Single Row Fiber Polarity under development TR-42.12 (Optical Fibers and Cables): ANSI/TIA-455-25-D, FOTP-25 Impact Testing of Optical Fiber Cables approved for publication Page 15

TR-42.12 (Optical Fibers and Cables), cont.: New project: ANSI/TIA-598-D-1, Optical Fiber Color Coding in Cable, Addendum for Additional Colors circulating for industry ballot New project: TIA-492AAAE, Detail Specification for 50-µm Core Diameter/125-µm Cladding Diameter Class 1a Graded-Index Multimode Optical Fibers with Laser-Optimized Bandwidth Characteristics Specified for Wavelength Division Multiplexing circulating for committee ballot 10+ documents circulating for reaffirmation or committee ballot Page 16

TR-42.13 (Passive Optical Devices and Metrology): ANSI/TIA-604-18, Fiber Optic Connector Intermateability Standard Type MPO-16 (FOCIS-18) approved for publication TIA-604-5-E: "Fiber Optic Connector Intermateability Standard, Type MPO (Multi-fiber Push On) (FOCIS 5) approved for publication Page 17

TR-42.13 (Passive Optical Devices and Metrology) cont.: New project: ANSI/TIA-455-171-B, "FOTP-171 IEC 61300-3-4 Attenuation by Substitution Measurement for Short Length Multimode Graded Index and Single-Mode Optical Fiber Cable Assemblies circulating for committee ballot TR-42.16 (Grounding and Bonding): ANSI/TIA-607-C, Structural Metal approved for publication Page 18

Upcoming TIA Meetings TR-42.7 Interim Meeting December 8-9, 2015 Miami, FL TR-42 Plenary Meetings January 25-29, 2016 New Orleans, LA www.tiaonline.org Page 19

Thank you Contact Information: Valerie Maguire The Siemon Company 101 Siemon Company Drive Watertown, CT 06795 phone: (602) 228-7943 valerie_maguire@siemon.com Page 20