SINAMICS DC Master (DCM) Base Drive

Similar documents
SINAMICS DCM Cabinet. DC drive converter cabinets for fast and simple system integration. siemens.com/sinamics. Answers for industry.

SIMOREG 6RA70 DC MASTER SIMOREG CM

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

SINAMICS S120. High-performance chassis unit drives. Unrestricted Siemens Industry, Inc usa.siemens.com/sinamics-s120

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

ENGINEERED SOLUTIONS. Solutions for Any Application. us.mitsubishielectric.com/fa/en/

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

What is your drive? Simply get started? SINAMICS GM150: The uncomplicated medium-voltage AC drive. sinamics

SINAMICS DCM. The innovative DC drive scalable and with integrated intelligence. usa.siemens.com/sinamics-dcm. Answers for industry.

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units. Catalog DA

SSW06. Soft Starters.

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Master the elements in water and wastewater applications siemens.com/sinamics-g120x

Siemens Industrial s

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

Master the elements in building automation siemens.com/sinamics-g120x

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

SED2 Variable Frequency Drives

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

SIMOCODE 3UF Motor Management and Control Devices

Motor Protection Solutions. Bulletins 193, 592, 809S, 813S, 814S, 817S and 825-P

ATV1200A kv kva

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

CATALOG SELECTION / PRODUCT SELECTION

SIMOREG Still leading the field - after years of success

SIMOREG DC-MASTER. Operating Instructions. 6RA70 Series. Microprocessor-Based Converters from 6kW to 2500kW for Variable-Speed DC Drives

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SINAMICS G120 Inverter chassis units 0.37 kw to 90 kw

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

DV-300 DC DRIVE. DV-300 DC Drive

HVAC Products. Introducing the SED2 Variable Frequency Drives

Technical Catalogue Softstarters

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

ABB Component Drives ACS55, 0.25 to 3 Hp

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

Solid-State Switching Devices

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

The innovative interface for the last few meters to the process

Advanced Features. High Performance Stepper Drive Description. Self Test and Auto Setup

5 MICROMASTER 440 specifications

Control strategies for web handling

SIMOREG 6RA70 DC MASTER Electronics

MP7. Uninterruptible Power Supply

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

SINAMICS G110D Distributed inverters 0.75 kw to 7.5 kw (1.0 hp to 10 hp)

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

SECTION VARIABLE FREQUENCY DRIVES

Power Meter PowerMonitor 500

3RA13, 3RA14 Contactor Assemblies

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

What fulfills the highest demands on the current and voltage quality?

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

5 MICROMASTER 420 specifications

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Bulletin 817 Thermistor Protection Relay

Intrinsically Safe Barriers

6.22 Migration of SIMOTION D4x5 to SIMOTION D4x5-2

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Andover ContinuumTM. b3850 Series Terminal Controllers

Mentor II & Quantum III High Performance DC Drives

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

MAJOR VA Power Inverter

SINAMICS S120. Line Modules and line-side components. Basic Line Modules in chassis format. 2/60 Siemens D Overview

OPTIDRIVE PLUS 3 GV 3 rd Generation Vector Control AC Variable Speed Drive kW

ACS Product Overview

SIPLUS S7-200 TD 400 C

Asynchronous motors. 5/48 Permissible combinations of mechanical designs for 1PL6 motors,

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

VersaMax IP I/O Module

UNIDRIVE M200. Manufacturing Automation drives. Flexible machine integration through communications

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

SIMATIC S plus TIA Portal

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

ADJUSTABLE SPEED DRIVES. GX7 Series

Motor Controllers. On-Road AC Motor Controller. Model 1239E.

Transcription:

High-performance drives SINAMICS DC Master (DCM) Base Drive 3 hp (2.2kW) to 800 hp (600kW) DC I-rated Unmatched reliabilty and flexibilty for your system upgrade For many applications, DC drives are the best solution. Since DC motors have an extremely long lifecycle, saving the motor and upgrading the drive is often the most cost-effective and best solution. Combining leading edge DC drive technology with an existing application or motor installation, provides overall process improvements and minimizes system downtime all while keeping costs under control. SINAMICS DC Master Base Drive offers unmatched reliability and flexibility for your system upgrade. The SIMANICS DCM Base Drive builds upon the success of the Siemens SIMOREG DC drive. The Base Drive Concept is perfect for the retrofit and upgrade scenarios where shutdown times need to be minimized. The SINAMICS DCM Base Drive is extremely flexible and cost-effective for both new installations and retrofits where space is limited. The pre-wired solution comes complete and tested with all the necessary components mounted on a back panel. The product is ideal for end-users and thirdparties such as a Siemens solution partners and system integrators. The DC Base Drive has been around for over 25 years, beginning with the third generation 6RA22 digital DC drives, circa 1986. The SINAMICS DCM Base Drive is unique in that the DC I rating of the converter is used for each panel design. The advantage is more power per panel in the same footprint as the previous two generations of base drive panels. This makes it easy to retrofit existing base drive installations. In addition, in new installations where150% overload is not needed (i.e. MG Set Field supplies), the SINAMICS DCM Base Drive offers a significant cost advantage. SINAMICS DCM Base Drive includes: n Ethernet Connectivity provided as standard n UL and cul (508A) certification n 65 ka SCCR (short circuit current rating) n Dual-rated voltages 240V / 480V AC n Multiple current ratings set by parameter n Panel dimensions equivalent to the previous two generations of base drives n Windows-based STARTER software common to all models of the SINAMICS drive family n Drawings available in AutoCad /.dwg n Available from stock Note: All SINAMICS DCM base drives are provided with the Advanced CUD and CBE20 cards installed. The CBE20 allows for Ethernet programming capability as standard. Take advantage of Siemens progressive developments in Industrial Ethernet technology and open connectivity. With direct network connectivity to PROFINET, EtherNet/IP and standard Ethernet TCP/IP, SINAMICS base drives fit comfortably within your plant s network, providing you with maximum productivity and capacity planning. usa.siemens.com/drives

With SINAMICS DC Master Base Drives, increased productivity and decreased project costs directly result from extraordinary product reliability, unsurpassed dynamic performance and seamless integrat\ion into the automation environment Highlights of SINAMICS DC Master Base Drive Standard features n 3 to 800 hp in DC I rating or up to 500 hp with DCII rating as a pre-engineered, standard design minimizing engineering and delivery times n AC Contactors Line Side 15 850A, DC Loop Contactor >1200A n DC Converter Includes Advanced Control Unit DC (CUD) (G00), PROFINET Card CBE20 (G20), Micro Memory Card (S01) and Basic Operator Panel (BOP20) n DC Converter The 450A 1200A converters include a single phase fan at 230Vac (L21) as standard on the base drives. n Fusing input fuses, field fuses, DC output fuse for regen units n Control power transformer Base Drive benefits Typical user or target group Business drivers n Standard 4-port Ethernet Switch provides Ethernet Connectivity and Programming Capability n Easy- to-install n Pre-wired and tested for easy startup n Converters can be replaced without changing the panel n Drop in replacement for 6RA24 and 6RA70 base drives n More current per panel than previous generations n SINAMICS options are easy to add n 210A and below base drives can be run at singlephase incoming supply with drive de-rating. n Machine builders n Distributors n End-users n System integrators n Solution partners n Increased productivity n Proven track record n High-dynamic performance n Decreased project cost n Reduced maintenance costs 2

Product selection Typical horsepower @ continuous current w/ 150% 1 minute Use DCII rating Current xy = S2 (2 Quad) V6 (4 Quad) SINAMICS DCM Base Drive SINAMICS DCM dimensions DC I DC II Continuous Continuous at 240V DC at 500V DC Curent Current Model No. H W D HP HP Amps Amps 3 7.5 15 13.9 6RA8013-2FV62-0AA0* 25.1 10.6 10.6 All horsepower ratings above are calculated with the continuous rating used with (DC II) and 150% overload for one minute. * Amp ratings for the 6RA80 SINAMICS DCM Base Drive are based upon DC I ratings. No overload capability. SIMOREG 6RA70 Base Drive Model Easy migration SIMOREG 6RA24 Base Drive Model 7.5 15 30 24.9 6RA8018-2FV62-0AA0* 25.1 10.6 10.6 6RA7013-2Fxy2-0 6RA2413-2Fxy2 15 30 60 53.1 6RA8025-2Fxy2-0AA0* 25.1 10.6 13.2 6RA7018-2Fxy2-0 6RA2418-2Fxy2 20 40 90 78.2 6RA8028-2Fxy2-0AA0* 28.9 10.6 13.2 6RA7025-2Fxy2-0 6RA2425-2Fxy2 30 60 125 106 6RA8031-2Fxy2-0AA0* 32.7 10.6 12.0 6RA7030-2Fxy2-0 6RA2428-2Fxy2 50 100 210 164 6RA8075-2Fxy2-0AA0* 38.6 11.4 11.7 6RA7072-2Fxy2-0 6RA2471-2Fxy2 75 150 280 226 6RA8078-2Fxy2-0AA0* 44.1 11.4 13.0 6RA7075-2Fxy2-0 6RA2474-2Fxy2 100 200 450 320 6RA8082-2Fxy2-0AA0* 47.3 21.7 13.4 6RA7077-2Fxy2-0 6RA2477-2Fxy2 150 300 600 470 6RA8085-2Fxy2-0AA0* 47.3 21.7 13.4 6RA7082-2Fxy2-0 200 400 850 658 6RA8087-2Fxy2-0AA0* 47.3 21.7 15.3 6RA7083-2Fxy2-0 6RA2483-2Fxy2 250 500 1200 884 6RA8091-2Fxy2-0AA0* 60.0 32.0 20.0 6RA7087-2Fxy2-0 6RA2487-2Fxy2 Note: Custom designs above 500 hp are available upon request. Please consult your Siemens Representative or send an e-mail: drives-marketing.industry@siemens.com Supplementary control unit DC options SINAMICS DCM options Non-coated Catalog No. Coated Standard features Standard CUD 6RY1803-0AA00-0AA1 6RY1803-0AA20-0AA1 n 4 digital inputs n 4 bi-directional DI/DO n 4 digital outputs n 7 analog inputs n 2 analog outputs n 1 HTL / TTL pulse encoder n 1 temperature sensor n PROFIBUS connection n RS232/RS485 n Paralleling ports n MMC Flash connector n 4 three-color status LEDs Advanced CUD 6RY1803-0AA05-0AA1 6RY1803-0AA25-0AA1 The Advanced CUD includes the connections / features of the Standard CUD plus: two DRIVE-CLiQ Connection and one Option Slot (CBE20). Connector board 6RY1803-0GA00 The connector board needs to be ordered in addition to a CUD board. The CUD boards do not include the Connector board when ordered as a spare part. Note: 1. Standard CUD and Advanced CUD parts are meant to be replacements (upgrade or spare) for the CUD supplied with the converter. These parts do not include the screws and connector board. 2. To upgrade the unit with an additional CUD, the customer will need to purchase the spare CUD and the connector board. The connector board comes with all of the screws and studs to mount the CUD in the drive. 3

Supplementary communication board options Catalog No. SINAMICS DCM options Non-coated Coated Standard features CBE20 6SL3055-0AA00-2EB0 The CBE20 communication can be used to connect PROFINET IO network via the Advanced CUD. The CBE20 can also be programmed to be used a SINAMICS Link function in conjunction with the memory card. Memory Card 6RX1800-0AS01 The memory card can be used in either the Standard or Advanced CUD. The memory card offers the following options: n Additional languages can be downloaded in the AOP30. n Perform an offline long time trace n Download DCC block library n Software updates n SINAMICS Link Supplementary external components options SINAMICS DCM options Catalog No. (Non-coated*) Standard features Sensor Module Cabinet SMC30 mounted via DRIVE-CLiQ to option 6SL3055-0AA00-5CA2 Mounted features include the following interfaces: 1 DRIVE-CLiQ interface 1 encoder connection Sub D 1 connection for electronics power supply via 24V DC 1 PE / protective conduction cable Terminal Module TM15 via DRIVE-CLiQ to Advanced CUD boards Terminal Module TM31 via DRIVE-CLiQ to Advanced CUD boards 6SL3055-0AA00-3FA0 6SL3055-0AA00-3AA1 24 bi-directional digital inputs / outputs 24 green LEDs 2 DRIVE-CLiQ sockets 1 connection for electronics power supply via 24V DC 1 PE / protective conduction cable 8 digital inputs 4 bi-directional digital inputs / outputs 2 relay outputs with changeover contact 2 analog inputs 2 analog outputs 1 temperature sensor input (KTY84-130 or PTC) 2 DRIVE-CLiQ sockets 1 connection for electronics power supply via 24V DC 1 PE / protective conduction cable TM150 Terminal Module for RTD monitoring 6SL30550AA003LA0 A range of temperature sensors is supported: Pt100 Platinum RTD ** 100 ohm and Pt1000 Platinum RTD 1,000 ohm, KTY84 temperature sensor, PTC (Positive temperature coefficient thermistor), Temperature switch contact (Thermoclick, bimetallic, NC) The TM150 supports: Up to 12 sensors in 2-wire connection or up to 6 sensors in 3- or 4-wire connection DRIVE-CLiQ Cables 0.11m pre-fabricated 6SL3060-4AB00-0AA0 0.11 meter in length See D23.1 for different part numbers and lengths Advanced Operator Panel AOP30 6SL3055-0AA00-4CA5 AOP30 Advanced operator panel is an optional door mount option. Graphical LCD Display (240 x 64) with backlighting for plain-text display and bar-type display for process viables LEDs: RUN=green, ALARM=yellow, FAULT=red RS232 and (RS485 - SINAMICS DCM) 24V DC power supply Help functions Time and date memory with internal battery backup 26-key membrane keyboard RS 485 Cable for AOP30 to connection one CUD to AOP30 RS 485 Cable for AOP30 to connection two CUD to AOP30 6RY1807-0AP00 6RY1807-0AP10 Connection cable with integrated 24V power supply 3 meter cable Connection cable with integrated 24V power supply 3 meter cable * The supplementary external components options are not available as coated. ** The RTD inputs are not galvanically isolated. Only temperature sensors that meet the insulation requirements per IEC 61800-5-1 may be connected. 4

Product selection example 1 Application: The customer has an existing winder application with the following requirements: Supply input of 480V AC, 200 hp DC motor with encoder feedback, a continuous current of 315 amps and an overload requirement of 150% for one minute every 15 minutes. The winder application requires regeneration. The interface requirements for the application are PROFIBUS communication protocol, (8) digital inputs, (6) digital outputs, (4) analog outputs, (3) analog inputs, (2) relay outputs, and an additional encoder input to measure the diameter of the roll. Solution: The first step is to select the SINAMICS DCM base drive based upon the power requirements. Per the product selection table, look under the current rating column for the DC II rating that allows for continuous current plus the 150% overload requirement. From the product selection table, the proper selection for the SINAMICS DC Master Base Drive is: 6RA80822FV620AA0 450A, 4-Quad Unit Next, determine whether the standard features of the Base Drive meet the interface requirements, or whether additional field-installed options are required. The Advanced CUD, which is standard, provides the PROFIBUS interface and all other options except for 4 of the I/O points, the two relay outputs and the additional encoder interface. The optional TM31 Terminal Module provides the additional 4 I/O and the two relay outputs. The optional SMC30 Sensor Module provides the encoder interface. Both the TM31 and SMC30 connect to the Advanced CUD via DRIVE-CLIQ. The ordering data are as follows: 1 6RA80822FV620AA0 450A, 4-Quad SINAMICS DCM Base Drive 1 6SL3055-0AA0-3AA1 Terminal Module 31 1 6SL3055-0AA00-5CA2 Sensor Module Please check Catalog D23.1 SINAMICS DCM to select the best length DRIVE-CLiQ cables. Product selection example 2 Application: The customer has an existing motor generator set and is looking to upgrade the field on the generator. The input power is 240V AC, the motor field is rated at 56 amps at 150V DC and there is no overload requirement. The customer has no communication protocol requirement and the Start / Stop and speed reference (0- +10V DC) is discrete wired. The customer wants to utilize the existing cabinet and to replace the existing contactor, fuses and control components. Solution: Siemens can meet the customer s expectations with the SINAMICS DCM Base Drive. Additionally, use of the Base Drive will save engineering and installation time since the pre-engineered components are mounted on a sub-panel. The application does not require any overloads, so we can size the drive according to the product selection table and reviewing the current column and using the IEC I rated of continuous current. From the product selection table, the 60A unit is the best solution. Since the field control for the MG set is non-reversing, a 2-Quad non-reversing drive can be used. The Advanced CUD, which is provided as standard, has sufficient I/O to meet the discrete control requirements, so no additional options are required. The ordering data is as follows: 1 6RA80252FS220AA0 60A, 2-Quad SINAMICS DCM Base Drive For any application, it would be prudent to get the required motor data overloads and duty cycle. This would give the customer the best opportunity to size the drive correctly and not over-size in certain applications. 5

Technical information Electrical data Supply voltages and output ranges 240V / 480V 3-phase AC, ±10%, 3 to 700 hp / single-phase AC with 30% de-rate up to 125A continuous current Grounded or ungrounded supplies 45 Hz to 65 Hz 0V DC to +/- 500V DC Max. 1.8x rated DC current SCCR per UL508A: 65 ka Supply systems Rated line frequency Output voltage Overload possibility. Short circuit current rating Mechanical data Type of enclosure and color Open IP00 Type of cooling Self ventilated / forced-air ventilation Noise level LpA (1 m) 70 to 74.4 db(a) at 60 Hz line frequency Compliance with standards UL listing UL and cul (508A), drive components are listed UL508C Ambient conditions Operation Storage Transport Ambient temperature 32 F to 113 F (0 C to +45 C) -40 F (-40 C) to 158 F (+70 C) -40 F (-40 C) to 158 F (+70 C) Relative humidity (non-condensing) 5% to 95% 5% to 95% 5% to 95% at 40 C Installation altitude Up to 3,300 ft (1000 m) above sea level without reduction in performance, > 3,300 ft see derating data For more comprehensive information on the SINAMICS DCM Base Drive, please refer to Catalog D23.1 or the base drive instruction manual. Engineering information Overload capability The rated DC current specified on the unit rating plate (maximum permissible continuous DC current) may be exceeded in operation. The extent to which this value is exceeded and how long this lasts are subject to certain limits. The absolute upper limit for the value of the overload currents is 1.8x the rated DC current. The maximum overload duration depends on the time characteristic of the overload current as well as on the load history of the unit and also depends on the specific unit. Each overload must be preceded by an under load (load phase with load current < rated DC current). Once the maximum permissible overload duration has elapsed, the load current must return to at least an absolute value the rated DC current. The SINAMICS DCM Base Drive may be operated with five different overload setting configured in the drive parameters. n DC I through DC IV rated a 40 C n DC I Continuous Duty without no overloads possible n DC II Continuous rating with 150% overload for 60 seconds with a 15 minute cool down below base load current setting. n DC III Continuous rating with 150% overload for 120 seconds with a 15 minute cool down below base load current setting. n DC IV Continuous rating with 200% overload for 10 seconds with a 15 minute cool down below base load current setting. n US Rated Continuous rating with 150% overload for 60 seconds with a 15 minute cool down below base load current setting. Ambient temp at 45 C 6

Load class (parameter) Load for the converter Load cycle DC I l DC I continous (l dn ) DC II l DC II for 15 min. and 1.5 x l DC II for 60 s DC III l DC III for 15 min. and 1.5 x l DC III for 120 s DC IV l DC IV for 15 min. and 2 x l DC IV for 10 s U.S. rating l US for 15 min and 1.5 x l US for 60 s Note: with this setting, for all unit types, an ambient and / or cooling medium temperature of 45 C is permissable. STARTER the drive commissioning tool This easy-to-use software provides graphical support when it comes to the configuration and commissioning of drive components. STARTER is menu-assisted and allows all of the relevant data to be imported from the electronic rating plates of the drive components. This significantly reduces the associated costs, speeds up parameterization and prevents possible incorrect entries. Entries can be checked and parameters can be optimized using integrated test functions Drive Control Charts (DCC) SINAMICS can handle classic closed-loop drive control using Drive Control Charts. Drive-related open-loop and closed-loop control tasks can be shifted into the drive itself. This ensures the highest degree of flexibility when it comes to optimum adaptation to specific drive and automation scenarios. It also relieves the load on higher-level controls, simplifies the implementation of machine sequences and significantly increases the overall machine performance. 7

Siemens Industry, Inc. 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 1-770-871-3800 Order No. DCBR-DCMBD-0115 Printed in USA 2013 Siemens Industry, Inc. The information provided in this brochure contains only general descriptions or performance features, which do not always apply in the manner described in concrete application situations or may change as the products undergo further development. Performance features are valid only if they are formally agreed upon when the contract is closed. Siemens is a registered trademark of Siemens AG. Product names mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice.