MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Similar documents
MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: WL40EW2F. Wireless I/O WL40F Series

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: 40DN. Digital Panel Meters 40 Series

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

MODEL: 43AL1. Digital Panel Meters 43 Series

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

TABLE OF CONTENTS. Communication Functions

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

SYSMAC Remote Transistor Module

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MIC-2 MKII, Multi-instrument DATA SHEET

Power Transducers. Measuring most electrical parameters

Communications & Networking

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

SSI-1016H Specifications and Operation Manual

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

PGR-2601 MANUAL DC GROUND-FAULT RELAY

MODEL: CND. Multiplex Transmission System

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

I/O Expansion Module Installation & Reference

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

MODEL: 43DV2. Digital Panel Meters 43 Series

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

Communication Controller CC-Link/CPL Converter CMC10A

DATA CONNECT ENTERPRISE

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

FX-485PC-IF RS485 Interface Unit Hardware Manual

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Thread length (overall length) material

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Expansion Module HZS 541-1S

Terminal block 2 A 5 X 3. Specification

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

CNT24-2(USB)GY. Features. Isolated Counter Input Module for USB 2.0 CNT24-2(USB)GY 1. Ver.1.03

RS232C/RS485 Data can be easily monitored by LAN

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

MDA-8000 DIO User Manual

DIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

Measurement Systems Datascan Installation and User Guide

QSE-CI-NWK-E Control Interface

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

2. Actuator B: Ball type P: Pin type F: Flat type

Inductive Proximity Sensor

BA/BS4S Temperature Sensor Installation & Operating Instructions

Time Counters mini "h", DC Version

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Self-Powered Counters H7EC

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Simplified information where and how you want it.

Appendix 3 Using NS-AL002 Converters

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

Transcription:

PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system expansion via Modbus RTU Recorded data exportable to spreadsheet applications 175 (6.89) 115 (4.53) 40 (1.57) mm (inch) MODEL: -P4T-[1][2] ORDERING INFORMATION Code number: -P4T-[1][2] Specify a code from below for each [1] and [2]. (e.g. -P4T-M2/MSR/Q) Specify the specification for option code /Q (e.g. /C01) FIELD TERMINAL TYPE T: M3 screw terminals [1] POWER INPUT AC Power M2: 100 240 V AC (Operational voltage range 85 264 V, 47 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS (multiple selections) PC Recorder Software Package (must be specified) /MSR: With Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating PACKAGE INCLUDES... PC Recorder Software CD 9-pin D-sub connector, straight type (1 m or 3.3 ft) GENERAL SPECIFICATIONS Connection Power input, transmission: Euro type connector terminal (Wire size AWG24-12 (0.2 2.5 mm 2 ), stripped length 7 mm) : 9-pin D-sub connector (male) (Lock screw No. 4-40 UNC) I/O: M3 screw terminals (torque: 0.6N m) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Channel selector for the digital display: Rotary DIP switch; 1 thr. 8: ch.1 thr. ch.8 contact input A thr. D: ch.a thr. ch.d totalized counter input 0, 9, E, F: no display Isolation: or to I/O to power Node address setting: Rotary switch; 1 F (15 nodes) RUN indicator LED: Green light blinks in normal conditions. Count memory at power loss: Count value is saved in the the non-volatile memory (E 2 PROM) when the power supply is lost. Number of rewritable times: 10 5 times Data storing characteristics: 10 years at 20 C Indicators Digital display: 6-digit red LED; 4.6 mm high; Shows either totalized (lower 6 digits only) or momentary value; selectable with internal DIP switch COMMUNICATION Baud rate: 38.4 kbps Communication: Half-duplex, asynchronous, no procedure Protocol: Modbus RTU Standard: Conforms to, EIA Transmission distance: 10 meters max. Standard: Conforms to TIA/EIA-485-A Transmission distance: 500 meters max. Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) http://www.m-system.co.jp/ -P4 SPECIFICATIONS ES-5665 Rev.11 Page 1/5

INPUT SPECIFICATIONS Totalized Counter Input (high speed): Dry contact, 4 points Max. input frequency: 10 khz Minimum pulse width: 50 μsec. Max. counter value: 999 999 999 (reset to zero at overflow) Caution: The totalized counter itself can accept frequencies as high as 10 khz. In order to eliminate unwanted input by chattering, be careful to choose an input device to be free of the problem (e.g. mercury relay). Contact Input: Dry contact, 8 points Totalizing counter function Number of input channels: 8 Max. input frequency: 100 Hz Minimum pulse width: 5 msec. Max. counter value: 999 999 999 (reset to zero at overflow) Counter Reset Input: Dry contact, 1 point Logic: Enable at pulse edge sinking PERFORMANCE Multi-transmission time: 5 msec. Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute ( or RS- 485 to I/O to power to ground) OUTPUT SPECIFICATIONS Contact Output: Open collector, 8 points Rating: 24 V DC @ 50 ma (resistive load) Saturation voltage: 1.6 V DC For use with inductive loads, external protection of contact and noise quenching is recommended. INSTALLATION Power consumption AC: Approx. 10 VA DC: Approx. 7 W Operating temperature: -5 to +60 C (23 to 140 F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lb) http://www.m-system.co.jp/ -P4 SPECIFICATIONS ES-5665 Rev.11 Page 2/5

PC RECORDER SOFTWARE PC Recorder Software Package (model: MSRPAC-2010) is included with purchases of this model. Refer to the MSRPAC-2010 data sheet for the contents of the package and the requirements for the PC to be prepared by the user. EXTERNAL VIEW REAR VIEW Power Terminals 9-pin Connector RUN Indicator LED Connector Node Address Setting Rotary SW Configurator Jack TOP VIEW BOTTOM VIEW Totalized (lower 6 digits) or Momentary Value Display Contact Input LED T5 T6 T7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Channel Selector for Digital Meter Contact Output LED SW602 SW604 Totalized or Momentary Display Selector Momentary SW602 is fixed to the position 3. DO NOT CHANGE. Totalized (factory default) INTERFACE 1 5 6 9 ABBR. PIN NO. EXPLANATION OF FUNCTION BA (SD) 2 Transmitted Data BB (RD) 3 Received Data AB (SG) 5 Signal Common CB (CS) 7 Clear to Send CA (RS) 8 Request to Send 1 Not Used. 4 DO NOT connect. Connecting may 6 cause malfunctions. 9 http://www.m-system.co.jp/ -P4 SPECIFICATIONS ES-5665 Rev.11 Page 3/5

MODBUS WIRING CONNECTION CONNECTOR * 1 * 1 FG *2 *1. Internal terminating resistor is used when the device is at the end of a transmission line. *2. Install shielded cables to all sections and ground them at single point. CONNECTION DIAGRAM TOTALIZED COUNTER INPUT ch.a ch.b ch.c ch.d COUNTER RESET CONTACT INPUT CONTACT OUTPUT ch.1 ch.2 ch.3 ch.4 ch.5 ch.6 ch.7 ch.8 ch.1 ch.2 ch.3 ch.4 ch.5 ch.6 ch.7 ch.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 I/O Circuit Output Circuit Term. Resist. Power Circuit D-SUB CONNECTOR T5 T6 T7 + U (+) V ( ) FG Shielded Twisted-pair Cable To Other PC Recorders Jumper* POWER * When the device is located at the end of a transmission line via twisted-pair cable, (when there is no cross-wiring), close across the terminal with the attached jumper pin (or with a leadwire). When the device is not at the end, remove the jumper pin. DO NOT CONNECT to the terminals 5 thr. 8 or 10 thr. 16. Wrong connection may cause failure of the device. Caution: FG terminal is NOT a protective conductor terminal. http://www.m-system.co.jp/ -P4 SPECIFICATIONS ES-5665 Rev.11 Page 4/5

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) MODEL: -P4 175 (6.89) 10 (.39) 165 (6.50) T5 T6 T7 3 5 (.20) dia. MTG HOLES 15.5 (.61) 105 (4.13) 46 (1.81) 104 (4.09) DIN RAIL 35 mm wide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 14 (.55) 163 (6.42) FOR WALL MOUNT. 3 (.12) 40 (1.57) [6 (.24)] 6.2 (.24) 36 M3 I/O TERMINALS SYSTEM CONFIGURATION EXAMPLES RS-232C/ Converter (model: R2K-1) TC/DC Inputs (model: -GH2) Contact Inputs Contact I/O + Counter (model: -A1) (model: -P4) When the cable distance between the PC and the s is long, insert an / Converter for isolation. Specifications are subject to change without notice. http://www.m-system.co.jp/ -P4 SPECIFICATIONS ES-5665 Rev.11 Page 5/5