Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI

Similar documents
Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Lucy Phantom MR Grid Evaluation

Computational Algorithm for Estimating the Gradient Isocenter of an MRI Scanner

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Magnetic Resonance Elastography (MRE) of Liver Disease

COMPREHENSIVE QUALITY CONTROL OF NMR TOMOGRAPHY USING 3D PRINTED PHANTOM

S. Guru Prasad, Ph.D., DABR

3-D Compounding of B-Scan Ultrasound Images

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Use of MRI in Radiotherapy: Technical Consideration

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

New Technology Allows Multiple Image Contrasts in a Single Scan

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

MRI distortion: considerations for MRI based radiotherapy treatment planning

Investigation of a 3D system distortion correction method for MR images

Following on from the two previous chapters, which considered the model of the

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

MRI Physics II: Gradients, Imaging

Supplementary Information

Imaging protocols for navigated procedures

Abbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology

Automated segmentation methods for liver analysis in oncology applications

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

MRI-LINAC Dynamic Phantom

A Transmission Line Matrix Model for Shielding Effects in Stents

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

MR IMAGE SEGMENTATION

Overview of Proposed TG-132 Recommendations

Computational Medical Imaging Analysis Chapter 4: Image Visualization

The MSKCC Approach to IMRT. Outline

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

M R I Physics Course

Methodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion

RADIOMICS: potential role in the clinics and challenges

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

A Study of Medical Image Analysis System

3D imaging with SPACE vs 2D TSE in MR guided prostate biopsy

Development and Optimization of Fourdimensional Magnetic Resonance Imaging (4D-MRI) for Radiation Therapy

Sphere Extraction in MR Images with Application to Whole-Body MRI

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

TUMOR DETECTION IN MRI IMAGES

ANALYSIS OF PULMONARY FIBROSIS IN MRI, USING AN ELASTIC REGISTRATION TECHNIQUE IN A MODEL OF FIBROSIS: Scleroderma

Fmri Spatial Processing

Correlation between Model and Human Observer Performance on a Lesion Shape Discrimination Task in CT

Evaluation of AutoQA Lite TM Image Quality Measurement Software

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

Automatic Quantification of DTI Parameters along Fiber Bundles

A fast breast nonlinear elastography reconstruction technique using the Veronda-Westman model

Determination of rotations in three dimensions using two-dimensional portal image registration

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Effects of the difference in tube voltage of the CT scanner on. dose calculation

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

Virtual Phantoms for IGRT QA

Artefacts in body and breast MRI: lessons learned from second reading

Artefacts in body and breast MRI: lessons learned from second reading

k-space Interpretation of the Rose Model: Noise Limitation on the Detectable Resolution in MRI

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

Computer-Aided Diagnosis in Abdominal and Cardiac Radiology Using Neural Networks

A Virtual MR Scanner for Education

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM

Segmentation of Bony Structures with Ligament Attachment Sites

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

A Model-Independent, Multi-Image Approach to MR Inhomogeneity Correction

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

CHAPTER 3 RETINAL OPTIC DISC SEGMENTATION

Removal of EPI Nyquist Ghost Artifacts With Two- Dimensional Phase Correction

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

Data. MAGNETOM Symphony, A Tim System Matrix Coils

Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

MARP. Physicist s Role in ACR MRAP Accreditation May Carl R. Keener, Ph.D., DABMP, DABR Medical & Radiation Physics, Inc.

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

Correction for EPI Distortions Using Multi-Echo Gradient-Echo Imaging

Prostate Detection Using Principal Component Analysis

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2008 May 26.

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

Toward Magnetic Resonance Only Treatment Planning: Distortion Mitigation And Image- Guided Radiation Therapy Validation

An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy

This Time. fmri Data analysis

A two-step scheme for distortion rectification of magnetic resonance images

A study on image quality provided by a kilovoltage cone-beam computed tomography

Brilliance CT Big Bore.

Global Thresholding Techniques to Classify Dead Cells in Diffusion Weighted Magnetic Resonant Images

Conference Biomedical Engineering

A Comprehensive Method for Geometrically Correct 3-D Reconstruction of Coronary Arteries by Fusion of Intravascular Ultrasound and Biplane Angiography

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

ECSE 626 Project Report Multimodality Image Registration by Maximization of Mutual Information

An Improved Tracking Technique for Assessment of High Resolution Dynamic Radiography Kinematics

Automatic Quantification of DTI Parameters along Fiber Bundles

Where are we now? Structural MRI processing and analysis

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

Interpolation of 3D magnetic resonance data

Transcription:

Bio-Medical Materials and Engineering 26 (2015) S1431 S1438 OI 10.3233/BME-151441 IOS Press S1431 Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI Jochi Jao a, Mingye Cheng b, Hsintien Lee b, Julius Ting b and Pochou Chen c, * a epartment of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, 100, Shih-Chuan First Rd., Kaohsiung City, 80708, Taiwan, R.O.C. b epartment of Radiology, Antai Medical Care Cooperation Antai Tian-Sheng Memorial Hospital, No.210, Sec. 1, Zhongzheng Rd., onggang Township, Pingtung County 928, Taiwan, R.O.C. c epartment of Biomedical Engineering, I-Shou University, No.8, Yida Rd., Jiaosu Village Yanchao istrict, Kaohsiung City, 82445, Taiwan, R.O.C. Abstract. Magnetic Resonance Imaging (MRI) has been one of the most revolutionary medical imaging modalities in the past three decades. It has been recognized as a potential technique in the clinical diagnosis of diseases as well as tumor differentiation. Although MRI has now become the preferred choice in many clinical examinations, there are some drawbacks, which still limit its applications. One of the crucial issues of MRI is the geometric distortion caused by magnetic field inhomogeneity and susceptibility effects. The farther the lesion from the center of a magnetic field (off-center field), the more severe the distortion becomes, especially in low-field MRI. Hence, it might hinder the diagnosis and characterization of lesions in the presence of field inhomogeneity. In this study, an innovative multi-orientated water-phantom was used to evaluate the geometric distortion. The correlations between the level of image distortion and the relative off-center positions, as well as the variation of signal intensities, were both investigated. The image distortion ratios of axial, coronal and sagittal images were calculated. Keywords: Geometric distortion, field inhomogeneity, off-center field, multi-orientated water-phantom 1. Introduction Magnetic Resonance Imaging (MRI) is an imaging modality that has revolutionized medical imaging in the past three decades, possessing the advantages of three-dimensional imaging capability with no ionizing radiation involved and is non-invasive over other imaging modalities. MRI has now become the preferred choice in many clinical examinations because of its superior capability of providing high contrast among soft tissues. It can differentiate not only abnormal tissue from normal tissue but different tissue types as well. However, the possibility of geometric distortion in MR images * Address for correspondence: Pochou Chen, epartment of Biomedical Engineering, I-Shou University, No.8, Yida Rd., Jiaosu Village Yanchao istrict, Kaohsiung City, 82445, Taiwan, R.O.C.. Tel.: +886937633143; Fax: +886761515150; E- mail: pcchen@isu.edu.tw. 0959-2989/15/$35.00 2015 IOS Press and the authors. This article is published with Open Access and distributed under the terms of the Creative Commons Attribution and Non-Commercial License.

S1432 J. Jao et al. / Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI somewhat limits its full potential for use in some clinical applications. Geometric distortion in MRI can be classified as hardware-related [1-3] and tissue-related [3-5]. The hardware-related geometric distortion from MRI hardware is mainly the inhomogeneity in the main magnet, the gradient field nonlinearity, and the eddy currents induced by the switching of the gradient coils that are prominent in echo planar imaging (EPI). The tissue-related geometric distortion is mainly caused by susceptibility and chemical shift, which is imaging object-dependent. The image quality of MRI strongly depends on magnetic field strength and homogeneity [6-8]. Geometric distortion has long been regarded as a serious drawback of MRI. Geometric distortion caused by magnetic field inhomogeneity might not be readily depicted in high-field-strength MRI because the signal-to-noise ratio (SNR) is high. However, it will be notable in a low-field-strength MR scanner. In addition, it is found that the farther the region of interest is from the main magnet center, the more the geometric distortion [9]. For example, the MR images of a proximal femur and distal pelvis at 0.2 T are shown in Figure 1. Geometric distortions are clearly seen on both images. For MRI-based treatment planning for radiotherapy, high precision and accuracy is particularly required [6, 10]. A 3 multi-compartment phantom has been used to perform geometric distortion studies [9, 11]. Some 3 phantoms were used to study the effects of geometric distortion at 0.2 T and 1.5 T MRI respectively, in radiotherapy treatment planning of prostate cancer [12-15]. The geometric distortion is related to field-strength and homogeneity and regarded as an important issue in MRI. Hence, it would be valuable to evaluate the correlation among them. In this study, an innovative multi-orientated water-phantom was used for measurements of the geometric distortion. In contrast to other phantoms used to evaluate geometric distortions on MR images, this specially designed phantom is simple and feasible to obtain multi-circle images in all three orientations without repositioning the phantom. The correlations among the levels of image distortion related to the relative off-center position, as well as the variations of signal intensities, were investigated. 2. Materials and methods An innovative multi-orientated water-phantom was designed in order to perform axial, coronal and sagittal scans. This is a parallelepiped tank without upper parallelogram made of 1-cm thickness Plexiglas, and the dimension was 30 cm (L) 30 cm (W) 21 cm (H). 3 water-phantom used to perform the quantitative assessment for related geometric distortion of the MR scanner is shown in Figure 2. In order to achieve multi-orientated purpose, the water-phantom included removable test plate slots to slide the specially designed experimental test plates. The dimensions of the two experimental test plates were 30 cm 20 cm for axial and sagittal and 30 cm 30 cm for coronal orientation. Both experimental plates were designed to have similar test patterns with 9 9 and 9 5 2 equally spaced circular holes. The diameter of each hole is 16 mm and the equal center-to-center distance between two adjacent holes is 32 mm. Components of multi-orientated water-phantom containing slotted water tank and two removable test plates are shown in Figure 3. The phantom was filled with a water solution doped with NiCl2 6H2O (3.3685 g/l) and NaCl (2.4g/L). The study was performed on a GE Signa Profile Excite 0.2-Tesla MR system (GE Medical Systems, Milwaukee, WI) which is an open low-field permanent magnet MR unit. The saddle type Body Flex II (L size) coil, a receive-only coil with 1.45 m diameter, was used to cover the entire water phantom. After 3-plane (axial, coronal and sagittal) localizer scan, T1 weighted images (T1WI) were obtained using 2 Gradient Echo pulse sequence. The scanning parameters were listed as follows: TR/TE = 100 ms/min Full, 80, BW = 7.81 khz, Matrix size = 256 256, NEX = 12, FOV = 40 cm, slice thickness = 5 mm. The scan time was 5 minutes and 10 seconds. The scans were performed under au-

J. Jao et al. / Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI S1433 to-shim mode. The tape and landmark laser light were used to adjust the location of the coil to ensure that the coil was in the center of the gantry. The A4 copy papers were used to adjust the experimental test plate in the water phantom to the center of the coil. Afterwards, the experimental test plate was put into the water phantom before MRI scans. In order to avoid the presence of artifacts caused by air bubbles on MR images, all the air bubbles in the water phantom were carefully removed. A custom program using MATLAB software was used to analyze the T1WI. The center coordinate displacements, circularity, geometric distortion, and SNR of circle holes were evaluated. Afterwards, SSPS statistical software was used to perform statistical analysis. 2.1. The center coordinate displacements of circle holes in x-axis ( x ), y-axis ( y ) and z-axis ( z ) The definition of center coordinate displacement is the region of interest (ROI) center s coordinate of each circle hole on image subtracting the actual corresponding circle center s coordinate on Plexiglas as shown in Eq. (1). The MR images of multi-orientated water-phantom in three orientations are shown in Figure 4. Fig. 1. MR images of proximal femur (left) and distal pelvis (right). White arrows show the areas of geometry distortion. Fig. 2. Multi-orientated water-phantom in (a) axial (b) coronal and (c) sagittal configurations.

S1434 J. Jao et al. / Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI Fig. 3. Components of multi-orientated water-phantom containing slotted water tank and two removable test plates. x y z x x i i i z z i0 y y i0 i0 (1) whereas x i, yi and zi are the ROI center s coordinate of each circle hole on images along the x-axis, z are the actual corresponding circle center s coordinates on Plexiglas along the x-axis x i0, yi0 and i0 y-axis and z-axis, respectively. 2.2. Area distortion ratio ( Area ) The definition of Area distortion ratio is the ratio of ROI area of each circle hole to that of the center circle as shown in Eq. (2). A Area 100%, (2) A C whereas is the ROI area of each circle hole on images and hole on images. AC is the ROI area of center circle 2.3. Geometric distortion ratio ( g ) of the long axis and short axis The definition of geometric distortion ratio (circularity) is the ratio of the length of the short axis (i.e. shortest distance of two points on the circle and passing through the circle mass center) of each circle hole to the length of the long axis (i.e. longest distance) of each circle hole as shown in Eq. (3). llong g 100%, (3) l short whereas is the length of the long axis of each circle hole on images and is the length of the short axis of each circle hole on images.

J. Jao et al. / Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI S1435 2.4. SNR The definition of SNR is the ratio of ROI value (i.e. average signal intensity) of each circle hole to the standard deviation of background circle s ROI as shown in Eq. (4). ROI C SNR, (4) ROI BG whereas is the ROI value of each circle hole and is the standard deviation of background circle s ROI. ROI BG 3. Results 3.1. isplacement of the center's coordinate It was found that the distribution of magnetic field homogeneity tended to shift to the left along the x-axis, shift to the anterior along the y-axis, and shift to the inferior along the z-axis as shown in Figure 4. It was also found that the magnetic field homogeneity along the z-axis was superior. The displacements of the center's coordinate along x-axis, y-axis, z-axis respectively were in the range of - 4.56 mm to +6.13 mm, -6.13 mm to +6.13 mm, and -2.3 mm to +2.31 mm, as shown in Table 1. 3.2. Area distortion ratio It was found that the distortion ratio was in the range of 0.93-1.10 in the axial plane, 0.75-1.06 in the coronal plane and 0.89-1.10 in the sagittal plane as shown in Table 2. 3.3. Geometric distortion of the long axis and short axis It was found that the circularity was in the range of 1.00-1.19 in the axial plane, 1.00-1.20 in the coronal plane and 1.00-1.12 in the sagittal plane as shown in Table 3. 3.4. Signal-Noise ratio It was found that the largest ROI value was in the coronal plane, and was in the order of coronal > axial > sagittal as shown in Table 4. The box plots of SNR and center-displacements in three anatomically oriented slices as shown in Figure 5 were obtained by using SSPS statistical software. The SNR box plot clearly shows that the variation of SNR is different among the three orientated planes.

S1436 J. Jao et al. / Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI Fig. 4. MR image of the multi-orientated water-phantom in axial (left), sagittal (middle), and coronal (right) orientations. Table 1 Center s coordinate displacement of circle holes in three directions No. Min. (mm) Max. (mm) Mean S.. (mm) X-shift 171-4.56 6.13 0.37 0.11 Y-shift 171-6.13 6.13 0.25 0.14 Z-shift 171-2.31 2.31-0.10 0.05 Table 2 Geometric deformation of circle holes in three anatomical slices No. Min. (mm) Max. (mm) Mean S.. (mm) Axial 45.93 1.10.99.005 Coronal 81.75 1.06.95.008 Sagittal 45.89 1.10 1.01.006 Table 3 Geometric deformation of circle holes in three anatomical slices No. Min. (mm) Max. (mm) Mean S.. (mm) Axial 45 1.00 1.19 1.04.005 Coronal 81 1.00 1.20 1.05.004 Sagittal 45 1.00 1.12 1.05.004 Table 4 SNR of circle holes in three anatomical orientated slices No. Min. Max. Mean S. Axial 45 77.43 117.30 90.75 9.16 Coronal 81 70.88 123.13 94.49 13.14 Sagittal 45 56.37 104.67 85.45 10.71 SNR Contour lines of axial, coronal and sagittal planes were obtained by using a custom MATLAB program as shown in Figure 6. SNR was smaller at the center part in the left-right direction in the axial plane, especially, at the anterior and posterior sides. SNR was larger at the center part in the superior-

J. Jao et al. / Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI S1437 inferior direction in the coronal plane, especially, at the left and right sides. SNR was larger at the center part in the superior-inferior direction in the sagittal plane, especially, at the anterior and posterior sides. Generally speaking, the closer the coil is to the object, the higher the SNR. In conclusion, the SNR is in the order of coronal plane > axial plane > sagittal plane. However, the homogeneity of SNR obtained from the standard deviations is in the order of axial plane > sagittal plane > coronal plane. 4. iscussions It has been proven that the geometric distortion highly depends on magnetic field inhomogeneity in MRI. The geometric distortion of MR image initiates at the magnet center and presents in a radial manner. The farther the region of interest from the center, the more geometric distortion created. Fortunately, the field of view (FOV) is mostly less than 24 cm 24 cm in routine MRI examinations, excluding the chest, abdomen and pelvic examinations. It means that obvious image distortion is mostly present outside the FOV. Therefore, geometric distortion is not a crucial issue in MRI, and rarely leads to false diagnosis for examinations involving the head, neck, spine, and so on. However, the geometric distortion at the edges of MR images is always prominently present in chest, abdomen and pelvic examinations, and this may result in diagnosis failure or misinterpretation as shown in Figure 1. In order to avoid geometric distortion, it is important to make sure that the region of interest is placed as close to the magnet center as possible prior to the scan in examinations of extremities. Fig. 5. Box plot of circles' SNR (left) and center-displacements (right) in three anatomical orientated slices. Fig. 6. SNR Contour lines of (a) axial plane, (b) coronal plane and (c) sagittal plane.

S1438 J. Jao et al. / Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI References [1]. Wang and.m. oddrell, Geometric distortion in structural magnetic resonance imaging, Current Medical Imaging Reviews 1 (2005), 49 60. [2] P. ammann, O. Kraff, K.H. Wrede, et al., Evaluation of hardware-related geometrical distortion in structural MRI at 7 Tesla for image-guided applications in neurosurgery, Academic Radiology 18 (2011), 910 916. [3] L.N. Baldwin, K. Wachowicz, S.. Thomas, et al., Characterization, prediction, and correction of geometric distortion in 3 T MR images, Medical Physics 34 (2007), 388 399. [4] C.J. Bakker, M.A. Moerland, R. Bhagwandien and R. Beersma, Analysis of machine-dependent and objectinduced geometric distortion in 2FT MR imaging, Magnetic Resonance Imaging 10 (1992), 597 608. [5] K. Wachowicz, T. Stanescu, S.. Thomas and B.G. Fallone, Implications of tissue magnetic susceptibilityrelated distortion on the rotating magnet in an MR-linac design, Medical Physics 37 (2010), 1714 1721. [6] J.F. Prott, U. Haverkamp, N. Willich, A. Resch, U. Stober and R. Potter, Comparison of imaging accuracy at different MRI units based on phantom measurements, Radiotherapy and Oncology 37 (1995), 221 224. [7] T. Mizowakia, Y. Nagataa, et al., Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies, Radiotherapy and Oncology 57 (2000), 237 242. [8]. Wang,.M. odderll and G. Cowin, A novel phantom and method for comprehensive 3 measurement and correction of geometric distortion in MRI, Magnetic resonance Imaging 22 (2004), 529 542. [9] T. Mizowaki, Y. Nagata, K. Okajima, R. Murata, M. Yamamoto, M. Kokubo, M. Hiraoka and M. Abe, evelopment of an MR simulator: Experimental verification of geometric distortion and clinical application, Radiology 199 (1996), 855 860. [10]. Wang, W. Strugnell, G. Cowin,.M. oddrell and R. Slaughter, Geometric distortion in clinical MRI systems part I: Evaluation using a 3 phantom, Magnetic Resonance Imaging 22 (2004), 1211 1221. [11]. Wang, W. Strugnell, G. Cowin,.M. oddrell and R. Slaughter, Geometric distortion in clinical MRI systems part II: Evaluation using a 3 phantom, Magnetic Resonance Imaging 22 (2004), 1223 1232. [12] R.C. Krempin, K. Schubert, et al., Open low-field MRI in radiation therapy treatment planning, International Journal of Radiation Oncology Biology Physics 53 (2002), 1350 1360. [13] B. Peterscha, J. Bognera, A. Franssonb, T. Lorangc and R. Pottera, Effects of geometric distortion in 0.2 T MRI on radiotherapy treatment planning of prostate cancer, Radiotherapy and Oncology 71 (2004), 55 64. [14] C. Yu, Z. Petrovich and M.L.J. Apuzzo, An image fusion study of the geometric accuracy of magnetic resonance imaging with the leksell stereotactic localization system, Journal of Applied Clinical Medical Physics 2 (2001), 42 50. [15]. Mah, M. Steckner, A. Hanlon, et al., MRI simulation: Effect of gradient distortions on three-dimensional prostate cancer plans, International Journal of Radiation Oncology Biology Physics 53 (2002), 757 765.