Industrial motor controller for brushed DC motors 24 VDC

Similar documents
Industrial motor controller for brushed DC motors 24 VDC

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

QUINT-BUFFER/24DC/24DC/40

Operating instructions. Standstill monitor A / / 2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Power Supply HARTING pcon

Power Supply HARTING pcon

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR UC/ESAM4/3X1/1X2/B

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating instructions Evaluation system for flow sensors VS / / 2013

PSR DC/ESP4/2X1/1X2

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

SIPLUS S7-200 PS 203. Overview

Siemens Industrial s

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Assembly instruction / User manual

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

MDM 011-Z1 Regen Resistor

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

PHOENIX CONTACT Features

Signal Doublers. VariTrans A 20300

Original operating instructions Safety relay with relay outputs G1501S / / 2016

MINI-PS AC/10-15DC/8

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Redundancy unit CP-A RU

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

ELR H3-IES-PT- 24DC/500AC-...

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Installation, Operation and Maintenance Manual

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 07/2006

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

SITOP 3-phase 24 V DC, 20 to 40 A

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating Instructions Electronic Circuit Protector ESX10-TC-DC 12 V

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Redundancy Module QUINT-DIODE/40

Operating instructions. Monitor FD / / 2013

Power supply CP-E 48/1.25 Primary switch mode power supply

Voltage Current Front-mounting bracket

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Rhino PSM Power Supplies. Operating Instructions

Operating Instructions

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Manual. The 24V single-channel circuit breaker system

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

ETD-BL-1T-OFF-CC- 10S

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

PCT2000. User Manual. Precision current transducer 2000 A

TB6600 Stepper Motor Driver

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

MSI-RM2 Safety Relays

Product and functional description

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

is then retained absolutely without interruption.

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

High Power Electronic Gear Installation and operation Guide

Products no longer available

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Switched Mode Power Supply Operating manual PAP800

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Operating instructions. Monitor FR-1 / FR-1N / / 2013

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

External level devices for conductive point level switch

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

ISOMETER isoev425 with coupling device AGH420

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners. User manual

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Transcription:

Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown depends on direction of rotation - overcurrent indication output - adjustable current monitoring delay - short circuit detection - dynamic brake To snap onto the DIN rail EN 50022 Unit width: 17,5 mm Type M2-MWT-6-30 Article number 06.34.007 Operating data Nominal voltage Unom 24,0 VDC Supply voltage VCC 18.. 30 VDC Control inputs UDI 24,0 VDC Quiescent current typ I0 50 ma Technical data: load circuit Max. current / continuous load current Imax/Icon 15 / 6 A Short circuit current detection typ ISC 80 A Shut-down time after short circuit typ tsc 100 µs Power stage driver MOS-FET Other data Dimensions 17,5 x 70,4 x 85,0 mm Connectors push-in terminal, pitch 5 mm cross section 0,2 2,5 mm² Permissible ambient temperature Tamb -20.. +60 C Temperature monitoring / overvoltage protection yes / yes Status indication: error / right / left LED1 red / LED2 green / LED3 green Current limitation left adjustable over DIP(3,4) and TR2 0,4.. 6 A Current limitation right adjustable over DIP(1,2) and TR3 0,4.. 6 A Disable Time trimmer TR1 (CM-delay) 0.. 0,7 s Dynamic brake (Armature short circuit) always on 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Strübelweg 14 D-73553 Alfdorf, Germany Phone: +49 7172 93711 0 info@kaleja.com

Other data Installation orientation / Assembly any / top-hat rail EN 50022 Installation place, typical Switch cabinet Storage temperature -30.. +85 C Permissible humidity 0 to 95 %, non-condensing Weight 0,075 kg Start up time 2 s Hazardous substance norm RoHS2 EMC interference immunity EN 61326-1:2013-01 EN 61000-6-2:2005-08 EMC emitted interference, operation in industrial DC network EN 61326-1:2013-01, Class A EMC emitted interference, operation with power supply EN 61326-1:2013-01, Class B supply unit / power unit KDR 120-24, Ott GmbH & Co. KG or comparable Technical data: digital output overcurrent Ready GND (4,7kΩ Pull-Down) Overcurrent VCC Current typ IDO 700 [ma] Short circuit-proof Yes, self-limiting Technical data: digital input High Signal typ. U > 10 V Low Signal typ. U < 4 V Impedance typ. RDI 15 kω Flammability Housing, terminals, printed circuit board UL94V-0 Starting behavior After applying supply voltage, the module is ready for operation when the start up time has elapsed. Description The module is a two quadrant motor control for use in industrial environments. It ensures the switching on and off, as well as the controlled driving of motors. Over a DIP switch and two internal trimmer the motor current limit value for the overcurrent shutdown is for each direction of rotation adjustable. The continuous load current form the module is 6A. A digital output reports if the module is in overcurrent shutdown mode. Current monitoring delay is adjustable over Trimmer TR1. The module has two digital inputs to select the rotation directions and one digital input to reset the module if an overcurrent shutdown has appeared. 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Page 2/7

Typical application: Standard Typical application: PLC 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Page 3/7

Terminal diagram 4 5 6 digital output Reserved Reserved overcurrent NC NC High-active 1 2 3 digital input digital input Reserved direction left direction right NC (p- switch) (p- switch) 7 8 9 Motor winding B Motor winding A digital input reset (p- switch) 10 11 12 GND supply +24 V supply Reserved +/-10 % NC State table direction left (1) direction right (2) Motor A (9) Motor B (10) Funktion 0 1 VCC GND run right 1 0 GND VCC run left 1 1 GND GND dyn. braking 0 0 GND GND dyn. braking 0 = off 1 = on x = don t care Function: overcurrent shut-off The module has two trimmers(tr2 and TR3) and an DIP switch to adjust the maximum motor current. For each direction of rotation the maximum motor current can be set separately. See description setting the maximum motor current In case of an overcurrent shut-off the digital output (4) is set HIGH. To reset the module set a HIGH Signal on digital input reset (9) or set both direction inputs(1 & 2) to low and start again in any direction. Function: setting the maximum motor current The maximum motor current is adjusted via the DIP switch on the module. With the corresponding trimmer the current is adjustable from 50 to 100% of the current set at the DIP switch. Current[A] DIP1 DIP2 DIP3 DIP4 Min. Max. Trimmer Off Off X X 0,375 0,75 TR3 On Off X X 0,75 1,5 TR3 Off On X X 1,5 3 TR3 On On X X 3 6 TR3 X X Off Off 0,375 0,75 TR2 X X On Off 0,75 1,5 TR2 X X Off On 1,5 3 TR2 X X On On 3 6 TR2 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Page 4/7

Function: dynamic brake The motor always stops with dynamic brake while normal operation. Function: disable overcurrent shutdown The overcurrent shutdown is disabled while there is a HIGH signal applied on the digital input on terminal (9). The overload shutdown is still active. Function: overcurrent output The overcurrent output (digital output terminal 4) is high when the modul detects an overcurrent. With active overcurrent shutdown the motor is switched off simultaneous with the overcurrent output. With deactivated overcurrent shutdown the overcurrent output is high when an overcurrent is detected and the motor runs till overload shutdown or stop from the user. Device status The module status is displayed via the LEDs on the module front plate. LED1 LED2 LED2 meaning red green green Off Off Off Module is operational Off On Off Run right Off Off On Run left flashing Off On Module error 1 (see table) Occurred while running left flashing On Off Module error 1 (see table) Occurred while running right flashing flashing flashing Internal Error Function: overload / short circuit detection When the module detects overload or short circuit on the motor output, the motor switches off without dynamic braking. The motor can be restarted by means of a reset (9) or fresh setting of any input of direction of rotation. Function: current monitoring delay The current monitoring delay is adjustable by trimmer TR1. After setting any direction of rotation input the overcurrent shutdown is disabled for the adjusted time. Function: overload shutdown The module is internally protected with an overload shutdown. In case of rising of the motor current over the rated continuous load current the module switches of with a thermal safety function. After the shutdown the module is locked for a cooldown phase which is managed by the module. In case of an overcurrent shut-off the digital output (4) is set HIGH. To reset the module the cooldown phase must be elapsed and both direction inputs (1 & 2) must set to low and start again in any direction. Display elements Module errors are displayed as flashing sequences. The end of the sequence is indicated by a pause of 1 second. The number of flashes indicates the error number. Module error 1 1 overcurrent 2 Over-temperature 3 short circuit detected 4 overvoltage 5 overload 6 Under-temperature 7 Low supply voltage 8 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Page 5/7

Temperature derating At 100% duty cycle and aligned modules with 10mm spacing the following diagram is valid. Dimensional drawing A = 70,4 mm; B = 17,5 mm; C = 85 mm 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Page 6/7

Safety notes Maximum operational data The maximum operating data must not be exceeded. Installation The installation and start-up must be performed by specialist personnel exclusively. All affected components must be disconnected from the mains. Start-up For the first start-up, the motor should be operated without load. Risk of death Do not touch live parts after switching on! The assembly must be operated exclusively on safety extra-low voltage. With operation on extra-low voltage (e.g. via autotransformer), death or injury can occur. Fire protection The assembly must be installed in a switch cabinet, which is suitable as a fire protection enclosure. The assembly must be safeguarded with a pre-fuse aligned with the nominal data. Field of application The assembly may only be used as intended. Other components must be checked for their approvals and regulations. Safety devices An additional safety device must be used to bring the system into a safe state in case of a cable break, incorrect operation, failure of the control/controller unit. EMC / EMI The wiring must be done according to EMC / EMI standards. If necessary, shielded cables and EMC suppressors must be used for the connected consumer. For operation in a public low-voltage distribution network, the module must be supplied with an approved AC adapter. If the module is supplied with an AC adapter, other equipment, operated on the same power supply, must be suitable for use in industrial environments. Repairs Repairs must be performed by authorised persons exclusively. With unauthorised opening, the warranty cover is voided and this may also result in danger for the user and for the system. Maintenance The assembly is wear-free by design. For modules with cooling openings free air circulation must be checked at the cooling openings or on the housing at regular intervals. If necessary, the cooling holes / the housing must be cleaned. Good ventilation must be ensured. contact details ready-to-use motor control solutions electronics design & manufacturing KALEJA GmbH Strübelweg 14 73553 Alfdorf, Germany Phone: +49 7172 93711 0 Fax: +49 7172 93711 90 E-Mail: info@kaleja.com www.kaleja.com 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Page 7/7