DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

Similar documents
DEEP SEA ELECTRONICS PLC

DSE2548 LED expansion module INTRODUCTION

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

DSE2510/20 REMOTE DISPLAY MODULES. DSEGenset DSE2510/20 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS FEATURES

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS DSE890 / DSE891 GATEWAY INSTALLATION INSTRUCTIONS

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DSE334 ATS Controller Operators Manual

DEEP SEA ELECTRONICS PLC

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

DEEP SEA ELECTRONICS

DSEULTRA DSE3110 Series Control Module

DSEPOWER. DSE8721 Colour Remote Display Module. Document number Author : Anthony Manton

DSEPOWER. DSE7520 MK1 Mains Control Module. Document Number Author : Anthony Manton

DEEP SEA ELECTRONICS PLC

DSEULTRA DSE6100 Series Control Module Document Number

DSEPOWER DSE7510 Control Module Document Number

DEEP SEA ELECTRONICS PLC DSE334 Configuration Suite Software Manual

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DSE8005 SCADA Suite PC Software Manual

Solid State Battery Fuel Gauge

DSEEXTRA. DSE860 RS232 Ethernet Adaptor DSE865 RS485 Ethernet Adaptor Document Number Author : Anthony Manton

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

DATA SHEET Compact Genset Controller, CGC 200

Instruction Manual. EXDC Turbomolecular Pump Drive Modules. Item Number

Ultra Slim Relays 24

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

CompactBlock Guard I/O EtherNet/IP Safety Modules

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

DEEP SEA ELECTRONICS PLC

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

DIN16A DIGITAL INPUT MODULE USER MANUAL

CR:514 & CR:515 Acoustic Calibrator Page 1. CR:514 & CR:515 Acoustic Calibrator User Manual

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

NPCI-PMC Technical Reference Manual

FL MC 2000E (SM40) LC

PRODUCT SPECIFICATION. PC Board Relays. Series.

DEEP SEA ELECTRONICS PLC

Operating instructions. Switching amplifier DN0210 DN / / 2015

DSE8610 SYNCHRONISING AUTO START LOAD SHARE CONTROL MODULE DSE COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF LOAD SHARE APPLICATIONS FEATURES

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

16-Way Input 48-Way Output Card

Installation & Operation and Maintenance

NI PXI-1042 Series Power Supply Shuttle

MOXA TCC-120/120I User s Guide

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Product Data Sheet. Hochiki 8 Way I/O Card. Features

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

7511 / / / 711 / / 731 / Preset 27

RXTH DUAL ROOM SENSOR / SWITCH

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

RТTH DUAL ROOM SWITCH

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

Gateway BACnet IP/MS-TP slave KNX TP Code: EK-BJ1-TP-IP / EK-BJ1-TP-MSTP

NL-324BTR User manual (60706)

Vigil 3 Amplifiers. Installation Instructions

Relay Contact Output Modules

FLEX Ex Spring Clamp Terminal Base

XEC supercap (v. 1.0)

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

DEEP SEA ELECTRONICS PLC DSE8610 Control Module

DALI Gateway 5502DAL. Installation Instructions

* * Agilent Power Distribution Unit (PDU) Installation Guide

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

IQ21x Series Controllers

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Inventronics LED Driver 0 10V DMX RDM

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

DEEP SEA ELECTRONICS PLC DSEWebNet PC Internet Browser Software Manual

Digital input modules

DEEP SEA ELECTRONICS PLC DSEE800 Operator Manual

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

TF501, TF521 Terminal Bases

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

MIC-2 MKII, Multi-instrument DATA SHEET

Operating Instructions VEGAMET 381

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

DEEP SEA ELECTRONICS PLC DSE8860 Controller Operators Manual

LED Driver. Xitanium DALI 40W A 54V DALI XI040C110V054YPT2

Data Sheet IQ21x Series Controllers

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

ERF910. RF Repeater. Synco living

C-Bus Ceiling Sweep Fan Controller L5501RFCP. Installation Instructions

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

MODCELL 2050R Single Loop Controllers

User Manual Digital Input Module

Transcription:

DSEGenset DSE2548 DSENET OUTPUT EXPANSION MODULE ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment The DSE2548 is an LED expansion module that can be used with all DSENet compatible control modules. The module has been designed to display a maximum of eight individual LED indications up to a maximum distance of 1 KM (0.6miles). The DSE2548 is presented in a vertical enclosure. It includes an alarm sounder that is triggered when the host controller detects an alarm condition. The alarm can be muted directly from the DSE2548 using the front push button. The DSE2548 includes individual LEDs for each channel and a Power On LED that flashes when the link with the host controller is lost. ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 o C BS EN 60068-2-2 Bb/Be Dry Heat +70 o C VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 o C @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 o C @ 93% RH 48 Hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 ms DEGREES OF PROTECTION PROVIDED BY ENCLOSURES BS EN 60529 IP65 - Front of module when installed into the control panel with the supplied sealing gasket. COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS HOST MODULE (1) 1 DSENET EXPANSION DC POWER SUPPLY 8-35V COMPATIBLE WITH DSE7310/20, DSE8610/60/80 & DSE8710/60 DSE2548 7 OTHER HOST MODULE DSENET 2157 2130 2510/20 2548 CONFIGURABLE LEDS AUDIBLE ALARM 8 ISSUE 3

DSEGenset DSE2548 DSENET OUTPUT EXPANSION MODULE SPECIFICATION DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V Continuous CRANKING DROPOUTS Able to survive 0 V for 50 ms, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. MAXIMUM OPERATING CURRENT 112 ma at 12 V, 53 ma at 24 V MAXIMUM STANDBY CURRENT 74 ma at 12 V, 35 ma at 24 V DIMENSIONS OVERALL 180 mm x 116 mm x 42.7 mm 7.07 x 4.57 x 1.68 PANEL CUT-OUT 154 mm x 98 mm 6.06 x 3.86 MAXIMUM PANEL THICKNESS 8 mm 0.3 KEY FEATURES Eight configurable LEDs Works up to 1 KM (0.6 miles) from the host controller 10 modules can be linked together to one host controller ID SWITCH The rotary ID switch is used to select the address of the DSE2548 expansion module, as the host control module is capable of giving instructions to a number of DSE2548 expansion modules at the same time. RELATED MATERIALS TITLE PART NO S DSE2548 Installation Instructions 053-032 DSE2548 Operator Manual 057-084 DEEP SEA ELECTRONICS PLC UK Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com DEEP SEA ELECTRONICS INC USA 3230 Williams Avenue, Rockford, IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice. The contents are intended for guidance only. Registered in England & Wales No.01319649 VAT No.316923457 055-062/10/10 (3)

COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS DSEEXTRA DSE2548 LED expansion module 057-084 Author : Anthony Manton

Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales Fax: +44 (0) 1723 893303 E-mail : sales@deepseaplc.com Website : www.deepseaplc.com DSE2548 relay output expansion module Deep Sea Electronics Plc All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents Act 1988. Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to Deep Sea Electronics Plc at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. Deep Sea Electronics Plc reserves the right to change the contents of this document without prior notice. 2 057-084 Issue 1 DSE2548 LED expansion operator manual

1 BIBLIOGRAPHY... 4 2 INTRODUCTION... 4 3 SPECIFICATIONS... 5 3.1 PART NUMBERING... 5 3.2 POWER SUPPLY... 5 3.3 TERMINAL SPECIFICATION... 5 3.4 DSENET... 6 3.5 DIMENSIONS... 6 3.6 APPLICABLE STANDARDS... 7 4 INSTALLATION... 7 4.1 USER CONNECTIONS... 7 4.1.1 CONNECTOR A... 7 4.2 SCHEMATIC INTERCONNECTION DIAGRAM... 7 4.3 TYPICAL WIRING DIAGRAM... 8 5 CONTROLS AND INDICATIONS... 9 5.1 LED INDICATIONS... 9 5.2 SOUNDER... 9 5.3 PUSH BUTTON... 9 5.4 ID SWITCH... 10 6 FAULT DIAGNOSIS... 11 7 MAINTENANCE, SPARES, REPAIR AND SERVICING... 11 8 WARRANTY... 11 9 DISPOSAL... 11 9.1 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT)... 11 9.2 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES... 11 057-083 Issue 1 DSE2548 LED expansion operator manual 3

1 BIBLIOGRAPHY This document refers to and is reffered to by the following DSE publications which can be obtained from the DSE website www.deepseaplc.com DSE PART DESCRIPTION 057-074 7000 series operators manual 057-077 7000 series configuration software manual 2 INTRODUCTION This document details the installation requirements of the DSE2548 LED expansion module part of the DSEExtra range of ancilliary modules. DSE2548 LED expansion module is used in conjunction with compatible DSE controllers to provide additional LED indication functionality. The LEDs are configured in the host controller, the DSE2548 module is not itself configured aside from the ID switch detailed below. For further details on configuring the host controller you are referred to the relevant configuration software manual. 4 057-084 Issue 1 DSE2548 LED expansion operator manual

3 SPECIFICATIONS 3.1 PART NUMBERING 2548-001 - 00 Product type DSE 2548 relay expansion module 2548 Variant Standard product Hardware revision 00 Revision 1 001 At the time of this document production, there are no variants of this product and there have been no revisions of the module hardware. 3.2 POWER SUPPLY Minimum supply voltage 8V continuous, 4V for up to 5 minutes. Cranking dropouts Able to survive 0V for 50mS providing the supply was at least 10V before the dropout and recovers to 5 volts afterwards. Maximum supply voltage 35V continuous (protection to 60V) Maximum operating current 112mA at 12V, 53mA at 24V Conditions: All LED s lit and sounder active. Maximum standby current 74mA at 12V, 35mA at 24V Conditions:All LED s off and sounder inactive. 3.3 TERMINAL SPECIFICATION Connection type Screw terminal, rising clamp, no internal spring Min cable size 0.5mm² (AWG 20) Max cable size 2.5mm² (AWG 14) Recommended cable size Refer to table below 057-083 Issue 1 DSE2548 LED expansion operator manual 5

3.4 DSENET DSEnet is the interconnection cable between the host controller and the expansion module(s) and must not be connect to any device other than DSE equipment designed for connection to the DSEnet. Cable type Two core screened twisted pair Cable characteristic impedance 120Ω Recommended cable Belden 9841 Belden 9271 Maximum cable length 1000m (1km) when using Belden 9841 or direct equivalent. 500m (0.5km) when using Belden 9271 or direct equivalent. DSEnet topology Bus with no stubs (spurs) DSEnet termination 120Ω. Fitted internally to host controller. Must be fitted externally to the last expansion module by the customer. Maximum expansion modules Refer to host controller documentation NOTE : As a termination resistor is internally fitted to the host controller, the host controller must be the first unit on the DSEnet. A termination resistor MUST be fitted to the last unit on the DSEnet. See the section entitled Typical Wiring Diagram elsewhere in this manual for details. 3.5 DIMENSIONS Overall size Mounting type Panel cutout 180.0mm x 116.0mm x 42.7mm (7.07 x 4.57 x 1.68 ) Panel mounting 154mm x 98mm (6.06 x 3.86 ) 6 057-084 Issue 1 DSE2548 LED expansion operator manual

3.6 APPLICABLE STANDARDS BS EN 60068-2-1 (Minimum temperature) BS EN 60068-2-2 (Maximum temperature) BS EN 60950 BS EN 61000-6-2 BS EN 61000-6-4 BS EN 60529 (Degrees of protection provided by enclosures) UL508 NEMA rating -30 C (-22 F) +70 C (158 F) Safety of information technology equipment, including electrical business equipment EMC Generic Immunity Standard (Industrial) EMC Generic Emission Standard (Industrial) IP65 when mounted into panel with optional gasket IP42 when mounted into panel WITHOUT gasket Enclosure type 2 when mounted into panel WITHOUT gasket Enclosure type 12 when mounted into panel with gasket In line with our policy of continual development, Deep Sea Electronics, reserve the right to change specification without notice. 4 INSTALLATION 4.1 USER CONNECTIONS 4.1.1 CONNECTOR A Terminal Function Recommended size 1 DC supply positive 1.0mm² (AWG 18) 2 DC supply negative 1.0mm² (AWG 18) 3 Screen DSEnet only 4 A 0.5mm² (AWG 20) DSEnet only 5 B 0.5mm² (AWG 20) DSEnet only 4.2 SCHEMATIC INTERCONNECTION DIAGRAM 057-083 Issue 1 DSE2548 LED expansion operator manual 7

4.3 TYPICAL WIRING DIAGRAM 8 057-084 Issue 1 DSE2548 LED expansion operator manual

DSE2548 relay output expansion module 5 CONTROLS AND INDICATIONS Address Switch 5.1 LED INDICATIONS Function Power on / Link lost Colour RED Status 1-8 RED 5.2 Action Steady when DC supply is connected and data is being received from the host controller. Flashing when the DC supply is connected and the data connection to the host controller is not operating. Lit when the corresponding channel is active SOUNDER The 2548 LED expansion module has an integral sounder, activated upon a signal from the host controller. The controller will activate the sounder when an alarm becomes active and silence the sounder when an alarm mute button (local or remote) is pressed. 5.3 PUSH BUTTON Pressing the button will signal to the host controller that the button is pressed. The controller will respond by lighting all LEDs on the 2548 module (lamp test) and silencing the sounder (alarm mute). If configured to do so, the host controller will also perform a lamp test and alarm mute function. Lamp test/alarm mute 057-083 Issue 1 DSE2548 LED expansion operator manual 9

5.4 ID SWITCH The rotary ID switch is used to select the Identification of the 2548 expansion module as the host controller is capable of giving instructions to a number of 2548 expansion modules at the same time (consult relevant modules instructions for further details on number of supported expansion units). The switch (located at the rear of the module) should be operated using a small screwdriver and set to match the required ID. NOTE : The ID MUST be a unique number, different from the ID of any other 2548 module connected to the host controller. If two or more 2548 controllers are required to mimic each other then they should be configured with different IDs, and both configured the same in the host controller. NOTE : The selection of the ID of other types of expansion modules WILL NOT interfere/clash with the ID of the 2548. For instance if the 2548 is set to ID4, it is acceptable to have a different type of expansion module (for instance 2130) set to ID4 also. 10 057-084 Issue 1 DSE2548 LED expansion operator manual

6 FAULT DIAGNOSIS Nature of problem LEDs don t activate on the 2548 module Power LED indication does not illuminate Power LED flashes Suggestion Ensure the host controller is correctly configured to send signals to the 2548 Check polarity and size of the connected DC supply are within the specifications of the DSE2548 This means the the communications link to the host controller has been lost. Check the connection of the DSEnet paying particular attention to the cable type being used and the positioning of the termination resistors. 7 MAINTENANCE, SPARES, REPAIR AND SERVICING The DSE2548 is designed to be Fit and Forget. As such, there are no user serviceable parts. In the case of malfunction you should contact your original equipment supplier (OEM). 8 WARRANTY DSE provides limited warranty to the equipment purchaser at the point of sale. For full details of any applicable warranty, you are referred to your original equipment supplier (OEM). 9 DISPOSAL 9.1 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT) Directive 2002/96/EC If you use electrical and electronic equipment you must store, collect, treat, recycle and dispose of WEEE separately from your other waste. 9.2 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES Directive 2002/95/EC:2006 To remove specified hazardous substances (Lead, Mercury, Hexavalent Chromium, Cadmium, PBB & PBDE s) Exemption Note: Category 9. (Monitoring & Control Instruments) as defined in Annex 1B of the WEEE directive will be exempt from the RoHS legislation. This was confirmed in the August 2005 UK s Department of Trade and Industry RoHS REGULATIONS Guide (Para 11). Despite this exemption DSE has been carefully removing all non RoHS compliant components from our supply chain and products. When this is completed a Lead Free & RoHS compatible manufacturing process will be phased into DSE production. This is a process that is almost complete and is being phased through different product groups. 057-083 Issue 1 DSE2548 LED expansion operator manual 11