RF HAMDESIGN. Driver MD-01 MD-01

Similar documents
SPID Elektronik. Driver MD-02 MD-02

Rotor BIG-RAK

SPID Azimuth & Elevation antenna rotator P/N: BIG-RAS/HR

Rotator and Controller by Spid. User Manual

Rotator Genius Manual

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Antenna Rotator System

Domain 3000 Back Panel

Sierra Radio Systems. Digital Compass. Reference Manual. Version 1.0

KTA-250 Anemometer Alarm Card

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Rotator Genius Instruction Manual v1.3.3

Simple Rotator control according to the N1VF controller

Antenna Rotator System USB

WiFi to RS-232 adapter user manual

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

4.8 Expansion Module MAC00-FS1/FS4

User s Guide. Ethernet Module for Barcode Printer

CEM120 Firmware Upgrade

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

DCM Dynamic Contact Measuring

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

4.7 Expansion Module MAC00-FS1/FS4

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ACORN User Guide For Revision (Aka Acorn_rev3) Updated 1/23/17

WiFi to RS-422/485 adapter user manual

This is the procedure to use the Clone module as a serial converter: To enable communication you must set the following parameters in the drive.

MDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24

CONTROL PROTOCOL Motorized Projection Screens

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

Industrial Serial Device Server

SERVO-DRIVE. PROGRAMMABLE STEP MOTOR CONTROLLER R ETH and R ETH. Manual Ver. 05

SitePORTAL Lite TA-SPL32-R48

In-motion Upgrade Instructions

Cube II/Cube Pro with Go2Nova 8408 Hand Controller Firmware Upgrade

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

CH1. Figure 1: M3 LOG Advanced

Getting started with your DGH module:

HomeVision-Pro Overview for HomeVision Users

E101 - Strain Gauge Transducer Display Module. Contents

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Field Service Procedure Replacement Azimuth Motor Kit, 3011

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Flex Series User Guide

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

Centroid ACORN CNC controller Specification and Use Guide Updated 8/3/17. Overview

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

UC-2000 Installation Manual Unicorn Computers Technology Limited

AirCare General Purpose ModBus Interface ACM1001. OptiDrive Modbus Module Product Specification. For assistance call

ZEQ25GT with Go2Nova 8408 Hand Controller Firmware Upgrade

WHAT. is ATEN Control System?

WiFi to RS-232 adapter user manual

Specifications N Termination Voltage Range Current Consumption, Max. Type Number Termination. Voltage Range. Sinking Sensor Current

TouchKit Touch Panel User manual for imac Version: 3.1.4

Blue Point Engineering

CAM-KIT6. User Manual. Connects2Vision. Mirror with DVR & Rear Camera PRODUCT FEATURES:

JNIOR Series 3. Serial-to-Ethernet Manual. A Network I/O Resource Utilizing the JAVA Platform. Release 3.0. NOTE: JNIOR OS 3.1 or greater required

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

RC3KD TriKit RC3000D to ANDREW Trifold Interface Kit. Installation Manual

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

ELECTRONICS. Controllers... C-2

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

NetCom Plus 411 (NetCom 411, NetCom 411 PRO)

ROTOR CONTROL DXA. de K4JRG. User s Manual

CEM60 TM Firmware Upgrade

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion

Assignment 5. You can configure hardware options by setting jumper on the mainboard. See Figure 2-1 for jumper locations. Set a jumper as follows:

Installation OVERVIEW

PS2 Controller Starter Kit SKPS

the most flexible digital network for your gauging solutions

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

CX6DD Rotator Controller for Yaesu 5400.

USER GUIDE. to the CP130. Thermal Printer

INSTRUCTIONS MANUAL. ParaMon Software

DGH A3000 Configuration Guide For use with DGH Modules

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

Quick Installation Guide

Thermoelectric Cooler Controller TED1000

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

GuardMagic VF1-VF2 programming tool manual

ieq45 with 8407 Hand Controller Firmware Upgrade

NetCom Plus 111 (NetCom 111)

LLR-MOD Modbus Light Level and Occupancy Sensor

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

TileVision Interface Connections and Control Codes TV/19/FR1 & TV/26/FR1

MegaTrak MCU-9000 Harness Wiring

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Draft. CNC Controller Datasheet. 1 Features. 2 Applications

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

Assembly Instructions scancontrol 2700/2750 (500)

Transcription:

RF HAMDESIGN Driver MD-01 MD-01

Table of contents Table of contents... 2 Introduction... 4 Block diagram... 4 Parameters of the driver... 4 Photos and description... 5 Front... 5 Back... 5 Operation... 6 Normal mode (NORMAL)... 8 Calibration mode (MOTOR ANGLES)... 9 Driver MD-01 configuration... 9 Motor configuration... 9 TEMPLATE... 9 Start... 10 Stop... 10 External control (CONTROL xx)... 10 Protocol (PROT. xx)... 11 Set motors (SET MOTOR 1, SET MOTOR 2)... 11 STATE... 11 TYPE... 11 KIND... 11 INPUT... 11 GEAR... 11 MIN ANGLE... 11 MAX ANGLE... 11 MAX POWER... 12

START POWER, START TIME... 12 STOP POWER, STOP TIME... 13 STOP AT... 13 PULS TIMEOUT... 13 SET COM 0, SET COM 1... 13 STATE... 13 BAUD... 13 DATA BITS... 14 STOP BITS... 14 PARITY... 14 SET USB COM... 14 STATE... 14 BAUD... 14 DATA BITS... 14 STOP BITS... 14 PARITY... 14 SET ETHERNET... 14 STATE... 14

Introduction MD-01 is an electronic driver used for turning rotors. It is a multifunctional device, allowing for various combinations of work setting. The driver may be connected to two single rotors (e.g. two Azimuth rotors) or double (one Azimuth / Elevation rotor). The basic circuit provides operation with direct current motors. Block diagram Parameters of the driver supply voltage of driver MD-01 15 VDC (I max 2A), supply voltage of rotors 12-14 VDC (I max 40 A), the maximum current of a single motor up to 20 A. 2 x RS232 ports 1 x USB host port 1 x USB device visible in the system as the virtual COM port. 1 x Ethernet RJ45 port.

Photos and description Front 1. Keyboard. 2. 2x20 characters display. 3. Switch-key. Back 1. Plug-in socket to turn on Ground (the remaining NC PINs). 2. Rotor motor supply input (FUZE 40A). 3. NC, in the future planned for connecting modules, e.g. CAN, RS485, RS422 or analogue inputs. 4. Inching input for systemss with two sensors type HALL. 5. Electronics supply input (FUZE 2A). 6. Supply outputs for Rotor BIG-RAS Elevation. PINs for motor supply. Elevation PINs from the motor (3,4), PINs in the driver (1, 2). Every output has its own FUZE (20A). 7. Supply outputs for Rotor BIG-RAS Azimuth. PINs for motor supply. Azimuthn PINs from the motor (1,2), PINs in the driver (1, 2). Every output has its own FUZE (20A). 8. Switch used to update the driver software (FIRMWARE). To update the software we use COMO (item 12), while we turn the switch OFF. Normal mode of the driver is when the switch is in the PR position. 9. Universal output the possibility to connect inside the module driver with relays. Then the controller will have the function of antenna change-over switch. 10. I2C output used to control SW-01 switch. 11. USB HOST port (type A plug) and DEVICE port (type B plug). 12. RS232 ports COM0 and COM1. COM0 is also used to update the driverr software (see item 8). 13. Input used to control a specially designed mouse. 14. Network input RJ45 (ETHERNET). Descriptions of PINs of sockets in the back panel

How to connect MD-01 controller to BIG-RAS/HR rotor: #1 Connection of the engines AZ & EL: The rotor is connected by using the delivered connectors (4-pin type) and are used to drive the Azimuth and Elevation engines. AZ & EL (drawing below) are market at the back site of the MD-01 controller Both AZ &EL are using pin 1 and 2 from both connector. Connection insite the rotor is: AZ wire No1&2 / EL wire 3&4 Picture of connection insite the rotor is also in the PS-01 manual (Note: is you did not ordered the PS-01 PSU, you have to make your own connections)

Connection of the Sensor cable MD-01 <> BIG-RAS/HR #2 Connection of the sensor cable (AZ &EL) Delivered is a DB9 Male connector which is used to connect to MD-01. Connection at the rotor is done with a delivered 8-pol connector. Wire diagram below how to connect this connectors, you do need at least a 6-core control cable. MIC328 is at the rotor, DB9 Male is at the MD-01 controller back site

Operation MD-01 Driver may be operated with the use of a keyboard or a computer. MD-01 module has two modes (MODE). NORMAL normal mode. MOTOR ANGLES calibration mode. To change the mode, use the [F] key. Normal mode (NORMAL) In this mode the driver may be operated with the [Right], [Left], [Up] and [Down] buttons or receives the command from PC. The driver supports communications protocols such as SPID ROT1, SPID ROT2, SPID MD01, BRITE, YAESU and HyGain, which you can attribute to each communications port (COM0, COM1, USB D and ETH) in the settings. The [Right] and [Left] buttons are used to rotate the antennae in the azimuth. The right direction the antennae turns in a clockwise direction, the value of the angle in the display increases. The left direction the antennae turns in an anticlockwise direction, the value of the angle in the display decreases. The [Up] and [Down] buttons are used to rotate the antennae in the angle of elevation. The up direction the rotor turns right from the point of view of the front. The value of the angle in the display increases. The down direction the rotor turns left from the point of view of the front. The value of the angle in the display decreases. The directions of antennae rotation are shown in the picture:

Calibration mode (MOTOR ANGLES) To switch-over the driver in the calibration mode use the button [F]. In this mode you can set any value of the angle in the azimuth and in the elevation angle without turning the antennae. This mode is needed to preliminary calibrate the antennae. To set the azimuth angle to zero, push the [F1] and [Left] buttons simultaneously. In order to set the elevation angle to zero, push the [F1] and [Up] buttons simultaneously. To set any azimuth angle use the buttons [Left] and [Right], while to change the elevation angle use the buttons [Up] and [Down]. After setting any azimuth angle use the buttons [Left] and [Right], while to change the elevation angle push the buttons [Up] and [Down]. After completing the calibration you need to leave the calibration mode and come back to the normal mode by pushing the [F] button. Driver MD-01 configuration When driver MD-01 is in NORMAL mode you can use button [S] to enter configuration. The structure of driver configuration is modular. Select module using buttons [Left] or [Right]. When you select module you can use button [S] to enter in its parameters. Moving between parameters is done with buttons [Left] or [Right]. Value of parameter can change with buttons [Up] or [Down]. Button [F] is used for exiting configuration. After pushing button there is question about writing current configuration. If we want to confirm changes we are pressing button [Left], if we want to go back to previous configuration we are pressing [Right]. Motor configuration The number before the ":" in the name of the template determines which connector on the rear panel must be connected motor: 1. AZIMUTH 2. ELEVATION TEMPLATE Type of motors connected to the controller is pre-set by templates: 1:NC, 2:NC - no motors connected to the controller, 1:AZ, 2:NC - a motor is connected on the rear panel of controller on connector AZIMUTH. Motor rotates only in azimuth, 1:NC, 2:EL - a motor is connected on the rear panel of controller on connector ELEVATION. Motor rotates only in elevation, 1:AZ, 2:EL - there are two motors connected to the controller. Motor 1 (connector AZIMUTH) rotates in azimuth, and Motor 2 (connector ELEVATION) - rotates in elevation,

Start 1:AZ, 2:AZ - there are two motors connected to the controller, which is rotated in azimuth only. Motors run mode: Stop MAX SPEED - motor starts with max speed, that is set for each motor separately in modules SET MOTOR 1 and SET MOTOR 2, described later, SOFTLY so-called soft start. For each motor set in the module SET MOTOR 1 and SET MOTOR 2, described later. Motors stop mode: IMMEDIATELY at once, SOFTLY so-called soft stop. For each motor set in the module SET MOTOR 1 and SET MOTOR 2, described later. External control (CONTROL xx) This parameter specifies the communication port driver that is used to control the connected motors. Appears only if the chosen template is different from 1: NC, 2: NC. If the latter is chosen template 1: AZ, 2: AZ, then for each motor, you can choose another port for control. On display of controller can show few descriptions it depends of selected motors template: CONTROL A1 motor template 1:AZ, 2:NC or 1:AZ, 2:AZ, CONTROL E2 motor template 1:NC, 2:EL, CONTROL AE motor template 1:AZ, 1:EL, CONTROL A2 motor template 1:AZ, 2:AZ. CONTROL parameter value: NONE - no external control. Motor controlled manually with buttons on driver, COM 0 - external control with selected protocol. Can be controlled manually, COM 1 - external control with selected protocol. Can be controlled manually, USB - controlled throughout USB D with selected protocol. Can be controlled manually, ETH - controlled throughout ETHERNET with selected protocol. Can be controlled manually.

Protocol (PROT. xx) Communication protocol between the controller and the control device (it may be, for example, a PC program): SPID ROT1 SPID ROT2 SPID MD01 - in the future. New communication protocol from SPID Elektronik YAESU - in the future. BRITE - in the future. New protocol created by SPID Elektronik firm and Space Analysis Center in Warsaw. HyGain - in the future. Set motors (SET MOTOR 1, SET MOTOR 2) STATE Read only. Depends on a TEMPLATE configured motors (see Motor configuration -> TEMPLATE). It defines if motor is switched on or switched off. TYPE Type of motor return signal: DIGITAL controller counts pulses, ANALOG in the future. Controller measures the voltage. KIND Read only. Depends on a TEMPLATE configured motors (see Motor configuration -> TEMPLATE): AZIMUTH motor rotates in azimuth, ELEVATION motor rotates in elevation. INPUT Sensor type of driver MD-01 (only when the input type is DIGITAL): ELECTRONIC - using electronic motion sensors (without vibration), MECHANIC - in the future. Mechanical switches (vibration). GEAR Gear motor. MIN ANGLE Minimum angle, it is possible to be turned for which motor. MAX ANGLE Maximum angle, it is possible to be turned for which motor.

MAX POWER Maximum power in a percent s of full power, which the driver can provide rotor. START POWER, STARTT TIME We use if we want to obtain a so-called soft-start. We can set one, two or three-stage motor start (START POWER 1, POWER STARTT 2, START and START POWER 3 TIME 1, TIME 2 START, START TIME 3). Power (START POWER) is introduced as a percentage of full power, which can provide a driver for the rotor. Time (START TIME) enter in seconds. Example: One-step - set the initial speed of rotation of the motor START POWER 1 = 30%, time to reach maximum power (MAX POWER) START TIME 1 = 5s and START TIME 2 = 0s - in this way, we specify that the engine start is a single step. MAX POWER = 100%. This means that the motor is started with 30% power, and within five seconds linearly increases power to 100%.

Example 2: three-step - set the POWER START 1 = 20% START POWER 2 = 30%, START POWER 3 = 50%, START TIME 1 = 3s, START TIME 2 = 3s, START TIME 3 = 3s, MAX POWER = 100%. This means that the rotor starts with 20% power, within 3 s power reaches 30%, followed by 3s power reaches 50% and last 3 s power up to 100%. way. STOP POWER, STOP TIME Use, if we want to obtain a so-called soft stop. It works the same way as soft start so that the other STOP AT Specifies how many degrees before the specified angle (for example, sent by a computer program like Orbitron) is to start the motor stopping. It matters if it is selected in the parameter mode STOP softly module MOTOR CONFIGURATION. PULS TIMEOUT Specifies how long the motor has run off its power, if it does not come from the motion sensor pulses. Applies only to motors of type DIGITAL. SET COM 0, SET COM 1 STATE Read only. Possible values: ON or OFF. BAUD Possible values: 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 and 460800.

DATA BITS Possible values: 4,5,6,7 or 8 bit. STOP BITS Possible values: 1 or 2 bit. PARITY Possible values: none, odd or even. SET USB COM STATE Read only. Possible values: ON or OFF. BAUD Possible values: 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 and 460800. DATA BITS 8 bit. STOP BITS 1 bit. PARITY NONE. SET ETHERNET The Ethernet port is set to dynamic IP address. Communication with this port is done with the help of one of the protocols (MD01 SPID, SPID ROT1, SPID ROT2, Yaesu, or HiGain BRITE). For example, the MD-01 driver received the IP address from a DHCP server 192.168.0.10. It can connect to it, for example, Hyper Terminal by selecting the type of connection TCP / IP (Winsock), set host address 192.168.0.10 and port number to 23. Protocol can be BRITE or Yaesu, because they are text protocols. STATE Read only. Possible values: ON or OFF.