Installation and Configuration English PTZ Control VMC Joystick Rev. 1.0.0 / 2010-07-20
Information about Copyright, Trademarks, Design Patents 2010 Dallmeier electronic The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. We reserve the right to make technical modifications. The manufacturer accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation, e.g. print or spelling errors, and for those not caused by intention or gross negligence of the manufacturer. Dallmeier electronic GmbH & Co.KG Cranachweg 1 93051 Regensburg, Germany www.dallmeier.com info@dallmeier.com All trademarks identified by are registered trademarks of Dallmeier electronic. All trademarks identified by *) are trademarks or registered trademarks of the following owners: Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the complete identification of third-party trademarks and indication of the respective holder of rights. In case that protected rights are not indicated separately, this circumstance is no reason to assume that the respective trademark is unprotected. www.dallmeier.com 2
Table of Contents 1 Introduction...4 1.1 Validity...4 1.2 Documents...4 1.3 Conventions...4 2 Safety Instructions...6 3 General Notes...8 3.1 Scope of Delivery...8 3.2 Transportation and Packaging...8 3.3 Appropriate Use...8 3.4 Performance Features...8 3.5 Warranty...9 3.6 Certifications...9 4 View and Connection...10 4.1 View...10 4.2 Connection...10 5 Commissioning...11 6 Key Assignment...12 7 Configuration...13 8 Technical Data...15 9 Technical Drawings...16 www.dallmeier.com 3
1 Introduction 1.1 Validity This document applies to the VMC Joystick. It has been created based on the following versions: Dallmeier VMC Setup 1.2.2.0 PView 7 7.0.2.9 1.2 Documents Commissioning The document entitled Commissioning contains the most important steps for the connection and commissioning of the device. The target audience is trained and authorized professionals (installers). Installation and Configuration (this document) The document entitled Installation and Configuration contains detailed descriptions of the installation, connection, commissioning and configuration of the device. Safety instructions, general notes and technical data are additionally provided. The target audience is trained and authorized professionals (installers). 1.3 Conventions This document contains various warning words and symbols that indicate potential sources of danger. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE indicates practices for preventing property damage, incorrect configurations or faulty operations. www.dallmeier.com 4
Instructions are indicated by arrows ( ). Expressions in bold/italics generally indicate a control element on the device (switches or labels) or on its user interface (buttons, menu entries). Paragraphs in italics provide information on basic principles, special features and efficient procedure as well as general recommendations. www.dallmeier.com 5
2 Safety Instructions Only use this unit if it is technically in proper working order, to the intended purpose and while keeping safety and potential dangers in mind. Qualified personnel Installation, mounting, connection, commissioning and configuration of the unit may only be carried out by qualified personnel. This also applies to the maintenance, testing and repair, whereat the regulations of the DIN VDE 0701 series of standards (repair, modification and inspection of electrical appliances) must be followed. Regulations The use of video and audio surveillance systems in general is strictly regulated. Inform yourself about the applicable laws and regulations regarding data, working and environmental protection before using the unit and ensure compliance with them. System components Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components can cause malfunctions, damages and data loss and can result in loss of warranty. Modifications Do not make any modifications to the hardware or software that has not been tested and approved by Dallmeier. Inappropriate modifications can cause malfunctions, damages and data loss and can result in loss of warranty. Documentation Carefully and completely read the documents included in delivery. Always observe the contained instructions, notes and warnings. Condensation water If the unit is brought from a cold to a warm environment, resulting condensation water can cause malfunctions and damages. In this case wait (up to 8 hours) until the unit has reached room temperature before commissioning. Operating conditions Unfavourable operating conditions can shorten the life of the unit and can cause malfunctions, damages and data loss and can result in loss of warranty. Observe the specifications given in the technical data, the operating condition requirements and the maintenance instructions. Shocks Shocks can cause malfunctions and damages. The unit may not be moved while in operation. Foreign bodies If objects or liquids get into the unit, immediately disconnect it from the power supply (pull out the power plug). Contact the sales partner responsible for your area. www.dallmeier.com 6
Burnt smell If you notice burnt smell or formation of smoke from the unit, immediately disconnect it from the power supply (pull out the power plug). Contact the sales partner responsible for your area. Opening The housing of the unit may only be opened by qualified personnel for commissioning, inspection, maintenance and repair. Disposal Disconnect the unit from the power supply. Remove all connected devices. Return the unit to your respective sales partner. www.dallmeier.com 7
3 General Notes 3.1 Scope of Delivery Included in the standard scope of delivery is: 1 VMC Joystick 1 USB cable 200 cm 1 Documentation Installation and Configuration (CD) 1 Documentation Commissioning (in print) The scope of delivery may differ depending on the ordered equipment, the device variant or the country of destination. The functional range of the device depends on the ordered equipment or device variant and may differ from this document s content. Certain functions and features may require an activation that is subject to costs. 3.2 Transportation and Packaging Store the original packaging for transportation at a later date. Dallmeier electronic is not responsible for damage resulting from unprofessional/improper transportation. The goods should only be shipped in their original packaging. If the original packaging is no longer available, ensure that the packaging used sufficiently protects the unit against damage, moisture, heat and cold. 3.3 Appropriate Use The VMC Joystick enables the remote control and display of up to 24 cameras via Dallmeier PView station PVS 7. The joystick s ergonomic design and compact construction form allows a user-friendly and efficient operation even in the most confined space. 3.4 Performance Features The VMC Joystick is especially characterised by the following functions and properties: Remote ccontrol of the speed, pan/tilt, focus, zoom and iris function of the PTZ dome cameras Control interfaces: USB Control via PView station PVS 7 2,4 up to 57,6 kbps Baud rate Supported control protocols: DCCP, Pelco D, Pelco P Control of up to 24 PTZ dome cameras User-friendly tri-axial joystick DIN EN 50130-4 certified www.dallmeier.com 8
3.5 Warranty The terms and conditions valid at the signing of the contract shall apply. 3.6 Certifications Following approvals/certifications were valid at the time of document compilation. CE DIN EN 50130-4 compliant www.dallmeier.com 9
4 View and Connection 4.1 View Fig. 4-1 A Joystick modul B Joystick A B 4.2 Connection C E Fig. 4-2 D ¾¾Open the cable interlock (C). ¾¾Connect the USB cable to the USB socket (D). ¾¾Insert the USB cable into the cable conduit (E). ¾¾Close the cable interlock (C). The VMC Joystick is ready for commissioning. www.dallmeier.com 10
5 Commissioning In order to take the VMC Joystick into operation proceed as follows. ¾¾Connect the VMC Joystick to the PC / workstation (hot-plug). The operating system detects the new device automatically. ¾¾Note the messages from the operating system. ¾¾Follow the instructions given by the operating system. ¾¾Finish the installation of the USB driver. The VMC Joystick is ready for operation with PView 7. Note the corresponding PView 7 documentation. The VMC Joystick should be calibrated after the installation of the USB driver. The appropriate operating system dialog can be opened in the system control. Windows XP ¾¾Open Start > Control Panel > Gamecontroller > Hydra Joystick. Windows 7 ¾¾Open Start > Devices and Printers > Hydra Joystick. www.dallmeier.com 11
6 Key Assignment E F D C B G H I A J K L Fig. 6-1 A Zoom Out B Zoom In C Close apperture D Previous split E Next split F Previous camera G Next camera H Open apperture I Focus + J Focus K Joystick L Joystick-Taste Pan a PTZ camera (PAN) ¾¾Move the joystick left or right. Tilt a PTZ camera (Tilt) ¾¾Move the joystick up or down. Zoom a PTZ camera on or off ¾¾Turn the joystick left or right to the live image. www.dallmeier.com 12
7 Configuration The VMC Joystick keyboard layout can be configured individually with PView 7 functions. This is done by the assignment of the corresponding hotkey combination. ¾¾Start PView 7. ¾¾Open the Configuration dialogue via Program > Configuration. ¾¾Select the HotKeys tab. Fig. 7-1 ¾¾Select the relevant Category. ¾¾Select the relevant Command. ¾¾Press the designated VMC Joystick key. The VMC Joystick key is displayed in the New hotkey field. ¾¾Confirm with Accept. ¾¾Proceed analogous for all relevant keys. ¾¾Finally confirm with OK. www.dallmeier.com 13
The following table shows the standard key assignment for a connected VMC Joystick. Category Command Key combination Key Main panel Next camera Joystick button 3 G Main panel Toggle digital zoom motor zoom Joystick button 12 Main panel Previous camera Joystick button 2 F Camera control Open aperture Joystick button 7 H Camera control Close aperture Joystick button 6 C Camera control Focus in Joystick button 8 I Camera control Focus out Joystick button 9 J Camera control Zoom in Joystick button 5 B Camera control Zoom out Joystick button 4 A Split Next Split Joystick button 1 E Split Previous Split Joystick button 0 D L www.dallmeier.com 14
8 Technical Data Following technical data was valid at the time of document compilation. Refer to www.dallmeier.com for possible updates. Type 3 axes with button Control Protocol DCCP, Pelco D, Pelco P Baud-Rate 2,4 up to 57,6 kbps Interface USB 2.0, Type B Mains voltage 5 V DC (via USB) Power consumption Max. 2,5 W Temperature + 5 C to + 35 C Humidity 10 70 % RH, non-condensing Dimensions Ca. 138 mm x 128 mm x 224 mm Weight Ca. 900 g Certificate CE, DIN EN 50130-4 www.dallmeier.com 15
9 Technical Drawings Top View 128 138 Fig. 9-1 Front View 224 Fig. 9-2 Unit: mm www.dallmeier.com 16
Declaration of Conformity This declaration is valid for following product: Equipment: Type: Camera control device VMC Hereby the equipment is confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility (2004/108/EC). The following company is responsible for this declaration: Dallmeier electronic GmbH & Co.KG Cranachweg 1 D 93051 Regensburg The measurements were carried out in accredited laboratories. For the evaluation of above mentioned Council Directives for Electromagnetic Compatibility and for Low Voltage following standards were consulted: DIN EN 55022: 2001-04 class B DIN EN 50130-4: 2003-10 DIN EN 61000-4-2: 2001-12 DIN EN 61000-4-3: 2003-11 DIN EN 61000-4-4: 2002-07 DIN EN 61000-4-5: 2001-12 DIN EN 61000-4-6: 2001-12 DIN EN 61000-4-8: 2001-12 DIN EN 61000-4-11: 2001-12 DIN EN 61000-3-2: 2001-12 DIN EN 61000-3-3: 2002-05 Regensburg, 20-0 - Dieter Dallmeier -CEO-