SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Similar documents
SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 120V 3kVA 2.4kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

SmartOnline 120V 1.5kVA 1.35kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Oversize Internal Batteries, Network Card Slot, LCD, USB, DB9

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower, Extended Run, SNMPWEBCARD Option, USB, DB9 Serial

SmartOnline V 1kVA 700W On-Line Double-Conversion UPS, Tower, C14 inlet, DB9 Serial

SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9

SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial

SmartPro 1kVA 800W Line Interactive Sine Wave UPS, SNMPWEBCARD option, 1U Rackmount, USB, RS232, EPO, 120V

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire

SmartOnline V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire

SmartPro 230V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

Model #: SU5000RT4UHV

SmartOnline 208/240 & 120V 8kVA 5.6kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch

SmartPro 1.5kVA 1000W Line Interactive Sine Wave UPS, 2U Rack/Tower, LCD, USB, RS232, EPO, 120V

SmartOnline 208/230V 2.2kVA 1.98kW Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9, ENERGY STAR

TAA-Compliant SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartOnline 208/230V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, SNMP Card Option, LCD, USB, DB9, ENERGY STAR

Model #: SU3000RTXL3U

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9

SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, V Hardwire output

MODEL NUMBER: SMART3000RMXLN. Highlights. Package Includes. Description

SmartOnline 208/240V 6kVA 5.4kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch, L6-30R & L6-20R

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

Model #: SU6000RT4UHVG

SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartOnline 208/240V 10kVA 9kW Double- Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline 120V 2.2kVA 1.8kW Double- Conversion UPS, Tower, Extended Run, Network Management Card Slot, LCD, USB, DB9

SmartOnline 240 & 120V 20kVA 18kW Double- Conversion UPS in 25U enclosure, Pre-installed Network Card, USB, DB9, Bypass, Hardwire

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

MODEL NUMBER: SU6000RT4UTF. Highlights

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9

MODEL NUMBER: SU6000RT4UHVHW. Highlights. Description. Package Includes

SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, USB, 8 Outlets

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

Model #: SU5000RT4UTF

SmartPro 120V 1kVA 900W Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, 8 Outlets

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartPro 208V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U Rack/Tower, Network Card Options, USB, DB9 Serial

SmartOnline 120V 2.2kVA 1.8kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, WEBCARDLX Network Interface, ENERGY STAR

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

Model #: SU1000RTXL2UA

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, Extended Run, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartPro 120V 1kVA 650W Line Interactive Sine Wave UPS, Tower, USB, DB9 Serial

TAA SmartPro 120V 1.5kVA 1.35kW Line- Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port

Model #: SU1500RTXL2U

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port

SmartOnline Hot-Swappable Modular UPS System On-line, double-conversion protection for mission critical applications

SmartPro 230V 1.5kVA 940W Line-Interactive UPS, Tower, DB9 Serial

SmartOnline 120V 2.2kVA TAA-Compliant UPS On-Line Double Conversion, 1.8kW, 2U, Network Card Option

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

SmartPro LCD 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD display, USB, DB9 Serial

SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications

SmartPro 120V 700VA 450W Line-Interactive Sine Wave UPS, Tower, 120 or 230V input, Network Card Options, USB, DB9

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

OmniSmart 120V 1000VA 700W Line-Interactive UPS, Tower, Built-In Isolation Transformer, USB port

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial

Omni LCD 900VA Tower Line-Interactive 120V UPS with LCD display and USB port

OmniSmart 120V 750VA 500W Line-Interactive UPS, Tower, Built-In Isolation Transformer, USB port

SmartOnline 208/240V 6kVA On-Line UPS Double Conversion, 5.4kW, 4U, Network Card Option, TAA Compliant

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

OmniVS 230V 1500VA 940W Line-Interactive UPS, Extended Run, Tower, USB port, C13 Outlets

Omni LCD 650VA Tower Line-Interactive 120V UPS with LCD display and USB port

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

Smart Pro line interactive UPS System - NAFTA assembled version of SMART2200NET

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

BC Personal 120V 450VA 280W Standby UPS, Tower, USB port, 3 Outlets

Transcription:

SmartOnline 200-240V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SUINT3000RTXL2U Description 3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 66cm (26 inches). Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 200/208/220/230/240V output with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 120V and overvoltages to 288V. Up to 97% efficiency in optional economy mode saves BTU heat output and energy costs. C20 inlet accepts a wide variety of optional cordsets. C19 and C13 output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in rackmount or tower configurations. Includes 4 post rackmount installation accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware accessories available. Field replaceable, hot swappable internal batteries and external battery packs. Features SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation Highlights 3000VA / 3kVA / 2500 watt on-line double-conversion 2U rack / tower UPS 200/208/220/230/240V 50/60Hz output; High efficiency economy mode option Expandable runtime; Hot-swap batteries USB, RS232 & EPO ports; support for SNMP/WEB card Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak 1 / 6 options Front panel status LEDs with detailed load and battery metering 2 independently switchable output load banks C20 inlet; C13 & C19 outlets, 2 C13 to C14 & 1 C19 to C20 power cables included Applications DISTRIBUTED SERVER ROOMS; NETWORK CLOSETS; SMALL BUSINESS NETWORKS; SMALL BUSINESS PHONE SYSTEM Package Includes SUINT3000RTXL2U UPS System 4 post rackmount installation brackets C19 to C20 power cable PowerAlert Software CD and cabling Owner's manual with warranty information

operating hours and high efficiency, low BTU emission operation during off-peak times Maintains continuous operation through blackouts, voltage fluctuations On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 200/208/220/230/240V (user selectable) with zero transfer time Supports operation at 50/60Hz (auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz (frequency conversion de-rates UPS capacity by 20%) Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types Corrects line voltage conditions as low as 120V and as high as 288V to within 2% of selected nominal voltage Standard internal battery set offers 15 minutes runtime at half load (1250W) and 6 minutes at full load (2500W) Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs Compact rackmount form factor installs using only 2 rack spaces (2U) with a depth of only 66cm / 26 inches Ships with all mounting accessories for 4 post rackmount installation Optional 2POSTRMKITWM enables 2 post rackmount installation Optional 2-9USTAND accessory enables upright tower placement Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints Built-in Emergency Power Off (EPO) interface with cable C20 inlet accepts a wide variety of user supplied input cordsets C19 & C13 output receptacles Includes 2 C13 to C14 and 1 C19 to C20 power cables Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 4 C13 outlets) Front panel LEDs offer current monitoring and battery charge level information Network grade AC surge suppression Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment Field replaceable, hot swappable internal batteries and external battery packs Specifications OUTPUT Output Capacity Details Max output is 3000VA / 2400W at 200, 208, 220V nominal settings Output Volt Amp Capacity (VA) 3000 Output kva Capacity (kva) 3 Output Watt Capacity (Watts) 2500 Output kw Capacity (kw) 2.5 2 / 6

Power Factor 0.8 Crest Factor 3:1 Nominal Output Voltage(s) Supported Nominal Voltage Details Frequency Compatibility Frequency Compatibility Details Output Voltage Regulation (Line Mode) Output Voltage Regulation (Economy Line Mode) Output Voltage Regulation (Battery Mode) Output Receptacles Included Output Power Cables Load Management Receptacles Hot-Swap PDU options Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 200V; 208V; 220V; 230V; 240V 230V default 50 / 60 Hz Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 20% during frequency conversion operation. +/- 2% -12%, + 10% +/- 2% (8) C13; (2) C19 Includes 2 C13 to C14 and 1 C19 to C20 power cables Two switchable 4 C13 outlet load banks PDUBHV20 (2U / 6 C13, 2 C19 outlets) Sine wave Pure Sine wave INPUT Rated input current (Maximum Load) Nominal Input Voltage(s) Supported Nominal Input Voltage Description UPS Input Connection Type 15A (200V); 14.4A (208V); 13.6A (220V); 13A (230V); 12.5A (240V) 200V AC; 208V AC; 220V AC; 230V AC; 240V AC 230V factory configuration C20 inlet UPS Input Cord Length (ft.) 5 ft / 1.5m (C19 to C20) Input Phase Single-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) Expandable Battery Runtime External Battery Pack Compatibility 6 min. (2500w) 15 min. (1250w) Supports extended runtime with optional external battery packs BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) Internal UPS Replacement Battery Cartridge Less than 4.8 hours from 10% to 90% (typical, full load discharge) RBC96-2U 3 / 6

Battery Access Battery Replacement Description Front panel battery access door Hot-swappable, replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 288 Undervoltage Correction Severe Undervoltage Correction 2% output voltage regulation during undervoltages to 160V 2% output voltage regulation during undervoltages to 140V (under 66% load only) or 120V (under 33% load only) LEDS ALARMS & SWITCHES LED Indicators Audible Alarm Alarm Cancel Operation Switches 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation Power-fail alarm can be silenced using alarm-cancel switch 2 Switches control off/on power status and alarm-cancel/self-test operation SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating EMI / RFI AC Noise Suppression AC Suppression Response Time 420 joules Yes Instantaneous PHYSICAL Included Mounting Accessory Description Installation Form Factors Supported with Optional Accessories Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) 4 post installation accessories included 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND) Rackmount 3.5 x 17.3 x 26 8.9 x 43.9 x 66 Rack Height (U Spaces) 2 UPS Power Module Weight (lbs.) 70.5 UPS Power Module Weight (kg) 32 UPS Shipping Dimensions (hwd / in.) 9 x 22 x 32.8 UPS Shipping Dimensions (hwd / cm) 22.9 x 55.9 x 83.3 Shipping Weight (lbs.) 87.9 Shipping Weight (kg) 39.9 4 / 6

Cooling Method UPS Housing Material Fan Steel ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 1000 AC Economy Mode BTU / Hr. (Full Load) 241 Battery Mode BTU / Hr. (Full Load) 1500 AC Mode Efficiency Rating (100% Load) AC Economy Mode Efficiency Rating (100% Load) 89% 97% COMMUNICATIONS Communications Interface Network Monitoring Port Description PowerAlert Software Communications Cable WatchDog Compatibility USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications Included USB and DB9 cabling included Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) No transfer time (0 ms.) in online, double-conversion mode 160V (100% load), 140V (66% load), 120V (33% load) 288V SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features Green Energy-Saving Features Cold-start operation supported Automatic inverter bypass; Hot swappable batteries High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); CE; Meets FCC Part 15 Category A (EMI); TAA Compliant 5 / 6

WARRANTY Product Warranty Period (Worldwide) 2-year limited warranty 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. 6 / 6