Stainless steel hygienic butterfly valves. F for imperial tubing. F for metric tubing. Features Keystone technology. Quarter turn operation. Isolation or regulation control. Equal percentage characteristics. Bi-directional capability. Fully machined L stainless steel body. Optional end connections. One-piece disc and stem assembly. High Cv slim profile disc. Integral valve position indicator. High grade seat material options. Combination dual or multi position handle assembly. High impact reinforced polymer handle with a stainless steel drive (full stainless steel option available). Integral padlocking as standard on manual valves. Maintenance friendly. Site repairable. Full range of optional accessories. General application A universal valve for isolation and control, in the food, dairy, brewing, pharmaceutical, beverage and chemical industries. The Figure and are designed to be easily automated with any of Keystone s actuators and controls. From the Figure Vertical Actuator and Figure Electronic Control Head, to the Figure 90 or Figure 9S actuator. Tyco reserves the right to change the contents without notice EBPJV-00-EN-00
Typical specifying sequence - valves Valve (Bare) F BW Valve Size Figure Number Trim Code End Connections Trim Body Disc Stem Seat Bearing 9 L Stainless Steel Stainless Steel Viton Acetal L Stainless Steel Stainless Steel EPDM Acetal L Stainless Steel Stainless Steel Silicon Acetal L Stainless Steel Stainless Steel Nitrile Acetal Typical specifying sequence - handles Handle F9 0SQ P Figure Number Stem Connection Material Code Code P S Material Polymer 0 Stainless Steel End connections F Butt Weld (std) IDF ISO /BS - (male) RJT/BSM BS (male) Clamp ISO (ferrule) F Butt Weld (std) DIN / (male) Clamp ISO (ferrule) BSP ISO (male) Notes For information on the Wafer Style Valve refer separate literature sheet. Tyco reserves the right to change the contents without notice page
F pressure drop / flowrates graph 90 0 0 0 0 mm (") 0mm ( /") mm (") mm ( /") mm (") mm (") Pressure Drop kpa 0 0 9 mm (") 9 0 0 0 Flow m/hr m 0 0 0 90 00 00 00 0 00 00 0 900 0 Note This chart is based on an F valve fully open, using water at 0 C. F pressure drop / flowrates graph 90 0 0 0 mm mm 0mm mm mm mm mm mm 0 Pressure Drop kpa 0 0 9 mm 9 0 0 0 Flow m/hr m 0 0 0 90 00 00 00 0 00 00 0 900 0 Note This chart is based on an F valve fully open, using water at 0 C. Tyco reserves the right to change the contents without notice page
Technical data Max Product Pressure at 0 C 0 kpa (0 bar). Min Product pressure at 0 C Full Vacuum. General Temperature Range: Minus 0 C to 9 C Max Static Temperature Silicon: 0 C EPDM: 0 C Nitrile: C Viton: 0 C Note Although the various seat materials available can withstand temperatures above the 9 stated, for short periods of time, such as for sterilisation and certain applications, the servicability of these seats at elevated temperatures does vary depending on the media, pressure and other variables. Therefore, this is best determined from experience gained with the application concerned. Parts list No. Description Material Standard Body L Stainless Steel ASTM A Disc Stem Stainless Steel ASTM A CFM Seat Silicon (White) FDA EPDM (Brown) FDA Nitrile (Black) FDA Viton (Red) - Handle Assembly High Impact Glass Reinforced Polymer or 0 Stainless Steel - Handle Plug/Screw Santaprene / 0 Stainless Steel Commercial Notch Plate 0 Stainless Steel ASTM A CF Body Fasteners 0 Stainless Steel ASTM A Bearings Acetal Commercial Tyco reserves the right to change the contents without notice page
E Valve Body Holes C Actuator Mounting F Holes Note Dimensions D and A shown above, are for the Buttweld configuration only. For other types of connections, refer to attached End Connection data. Dimension E is the maximum clearance length for either handle. Masses shown are for bare shafted butt weld valves only. fla fla PCD flb D F imperial valve dimensions (mm) Valve ØA ØA ØB C D E F PCD No. Hole Stem Conn. Mass Kv Size Holes Dia (kg) (Fully mm inches open).. 9.. 9 mm sq. 0. 0 /.0. 9.. 9 mm sq. 0... 9 9.0.0 mm sq.. / 0..9 0 0.0.0 9 mm sq.. 0...0 0.0 0mm sq..0 9. 0.0. 0. 9 mm sq....0. 9. 0 0 mm sq.. 0 F metric valve dimensions (mm) Valve ØA ØA ØB C D E F PCD No. Hole Stem Conn. Mass Kv Size Holes Dia (kg) (Fully mm inches open) - 0..0 9.0 mm sq. 0. 9 -. 9.. 9 mm sq. 0. 0 -. 9.. mm sq. 0.9 9 -. 99 9. 0. 9 mm sq.. 0-0.. 9. 09 0mm sq.. -. 9.0.0 0mm sq..0-0. 9.0.0 mm sq.. 9. 9.0 90. 0 mm sq.. 0 -.. 9. 0 0 mm sq.. 0 Tyco reserves the right to change the contents without notice page
F90 pneumatic actuator selection chart for F and F butterfly valves. F90 double acting pneumatic actuator - normal service mm 00 00 0 00 00 0 00 0 00 This actuator selection chart is a guide to the anticipated maximum torque required to operate the valve under the stated conditions. It includes seating, unseating (break-away), running torques and allows for stem bearing frictional forces. No additional safety factors are considered necessary unless the operating conditions are beyond the stated duties. F90 spring to close pneumatic actuator - normal service mm 00 0 00 00 () () (.) () () 0 00 00 00 00 0 0 0 F90 double acting pneumatic actuator - severe service mm 00 00 0 00 00 0 00 00 0 0 Service definitions Normal Service: When used with clean lubricating fluids at ambient temperature and at a maximum of 0 kpa (0 bar). Severe Service: All other applications. Notes: Actuation selection for 00 kpa ( bar) supply pressure is based on using 00 kpa spring pack. Actuator selection for all the others, 0-00 kpa (- bar) is based on using kpa spring pack. For spring to open actuator selection, consult factory. 00 = F90 00 00 = F90 00 0 = F90 0 0 = F90 0 0 = F90 0 F90 spring to close pneumatic actuator - severe service mm 00 0 00 00 () () (.) () () 00 00 0 00 00 0 0 0 0 0 Tyco reserves the right to change the contents without notice page
F9S pneumatic actuator selection chart for F and F butterfly valves. This actuator selection chart is a guide to the anticipated maximum torque required to operate the valve under the stated conditions. It includes seating, unseating (break-away), running torques and allows for stem bearing frictional forces. No additional safety factors are considered necessary unless the operating conditions are beyond the stated duties. F9S double acting pneumatic actuator - normal service mm 00 00 0 00 00 0 00 00 0 Service Definitions Normal Service: When used with clean lubricating fluids at ambient temperature and at a maximum of 0 kpa (0 bar). Severe Service: All other applications. Notes: Actuator selection for 00 kpa ( bar) supply pressure is based on using 00 kpa spring pack. Actuator selection for 00 kpa ( bar) supply pressure is based on using 00 kpa spring pack. Actuator selection for all the others, 0-00 kpa (- bar) is based on using kpa spring pack. For spring to open actuator selection, consult factory. 00 = F9S 00 00 = F9S 00 0 = F9S 0 0 = F9S 0 0 = F9S 0 0 = F9S 0 F9S single acting spring return pneumatic actuator - severe service mm 00 00 0 00 00 0 00 00 00 00 00 0 00 0 0 0 0 0 F9S double acting pneumatic actuator - severe service mm 00 00 0 00 00 0 00 00 0 0 F9S single acting spring return pneumatic actuator - severe service mm 00 00 0 00 00 00 00 00 0 00 00 00 0 0 0 0 0 0 0 0 Tyco reserves the right to change the contents without notice page
F imperial valve - available end connections (-mm) (-mm) (-mm) (-mm) ØA ØA ØA ØG ØA ØG ØA ØA D D D D Butt weld (std) for inch tubing (O.D. tubes) ISO 0/BS -/AS - IDF/FIL male part connection ISO /BS- RJT/BSM male part connection BS - Clamp connection ISO Dimensions (mm) mm inch ØA ØA ØA ØA ØA ØG ØG D D D D...0.0. IDF RJT 0 0 0 0 /.0.... IDF / RJT / 0 0 0.....0 IDF RJT 0 0 0 / 0..9 9. 0.. IDF / RJT / 0.... 9.0 IDF RJT 0 0 9. 0.0 9. 9.0 9.0 IDF RJT..0 -.0-0 - - Note: BSM modified version is available upon request, deduct.mm from dimension D. F metric valve - available end connections (-mm) (-mm) (-mm) (-mm) ØA ØA ØA Rd ØA ØG ØA ØA D D D D Butt weld (std) for tubing DIN, sheet - Connection male part DIN / BSP male DIN ISO Clamp Connection ISO Dimensions (mm) mm DIN ØA ØA ØA ØG D D D Rd 0.. G Rd x /.. G / Rd x / 0 0.. G / Rd x /. G Rd x / 0. 9 G / Rd 9 x /. 0 G Rd 0 x / 0. 9 G Rd 0 x /. - - - Rd 0 x /. - - 0 - Rd 90 x / Tyco reserves the right to change the contents without notice page