DP10001708 1 Mission critical multiservice access platform for utility, corporate and enterprise customers provides true multiservice capabilities to support a very wide range of legacy voice and data interfaces transported over IP and Next Generation SDH networks. It has the performance capabilities to handle almost any type of applications including IP, POTS (Plain Old Telephony Service) and SCADA (Supervisory Control and Data Acquisition). Very low latency means that time-critical applications, such as teleprotection, are supported. is designed to be backward compatible with your existing network for example, with Nokia s Dynanet and FMX2 product families. In addition, is offered along with a network management solution which also supports legacy equipment. This allows for a flexible migration towards a modern platform. The internal architecture has a modular structure that uses high-speed, point-to-point buses to meet both current and future needs offering a growth path from PDH to SDH and packet networks. 6-Slot Subrack 8+8-Slot /Dynanet Subrack Trunk interfaces: SDH Ethernet 1GE/10GE Versatility: 64 kbit/s cross-connection functionality for legacy TDM services (voice and data) including advanced path protection Optimized for strictly time critical, low latency applications Power-over-Ethernet functionality High capacity IP, TDM and Ethernet based tributary units High availability via redundant critical modules 16-Slot Subrack 2013-2015
DP10001708 2 Management Multiservice Manager and CLI can be managed locally or remotely either with Windows based Multiservice Manager (Local Craft Terminal with graphical user interface) or with Command Line Interface (CLI). Multiservice Manager allows easy access to all functions of while CLI is a textbased interface accessible via SSH or USB for advanced users. 2013-2015
DP10001708 3 Management The map view provides the general status of the network Drill down to open the rack view Network Management seamlessly integrates with the DNWP Network Management System. The DNWP Network Management System is a full featured NMS with FCAPS and a powerful End-to- End circuit provisioning function. End-to-End circuits can be created over PDH, SDH and packet layers and over different generations of network elements. Network topology view with map Fault management Configuration management Inventory management User management Performance management End-to-End circuit provisioning The DNWP NMS enables smooth migration from Dynanet or FMX2 to by supporting PDH, SDH and packet networks in the same platform. also interfaces with any Network Management System via its optional NorthBound Interface (NBI) over SNMP. The interface enables users to integrate Connection Master to an existing NMS over a standard interface. 2013-2015
DP10001708 4 Application examples Connection to legacy layer Compatible with FMX2 and Dynanet. Enables voice and data services between networks. Metro rings Provide Ethernet transport or SDH connectivity Dynanet FMX2 Node B Node A E1 loop protection Node C Multiservice access Multiplexer and SDH layers integrated in one single hybrid node. A large number of E1 links between layers no more needed. Ring MUX/Partial ring extensions Connectivity to all 3 rd party standard SDH equipment E&M, FXS, FXO Ethernet, PoE Data E1 e.g., hit70xx Local cross-connect Non-blocking cross-connect matrix 80x80 VC-4 and 230xE1/VC-12 at DS0 level. Optional advanced cross connections like data conferencing and E1 loop protection. Meshed critical networks Mixture of SNCP ring and terminal mux connections. DS0 E2E path protection available for time critical services. VC-4, VC-3, VC-12, DS0 2013-2015
DP10001708 5 Application examples TDM over IP TDM over Packet pseudowire connection. Channelized SAToP enables transmission of individual E1s or VC-12s and facilitates optimal bandwidth usage and support for P2P and P2MP connections. Dynanet FMX2 Dynanet FMX2 IP network Hybrid rings SDH and IP trunk interfaces in one single node. Native critical TDM services can be carried in SDH ring and native IP services in packet ring without any data transformations. 10GE can fulfill all capacity needs of future utility IP services. E1 IP Voice Data 1GE/10GE E1 IP Voice Data 2013-2015
DP10001708 6 Application examples Multipoint-to-point SCADA - centralized summing Centralized summing point requires only single configuration point and enables easy use of several link protection mechanisms. Central station n x VC-12 over & (SCADA server) Multipoint-to-point SCADA - distributed summing Legacy summing architecture in E1 networks for optimized utilization of limited resources. Compatible with Dynanet and FMX2. & & E1 over PDH or VC-12 over Central station (SCADA server) & Optical teleprotection C37.94 and data interfaces enable reliable and latency optimized connections between teleprotection systems. Power line Teleprotection system Teleprotection system nx64 kbit/s optical; 850 nm; distance 1.5 2 km with OTP nx64 kbit/s optical; 850 nm; distance 1.5 2 km with OTP SDH network 2013-2015
DP10001708 7 Technical data - interfaces CU SDH / CU SDH Extended Temperature T32001.01 / T32001.11 SFP interfaces 4 x STM-4/16, 4 x STM-1/4 or 4 x STM-4/16, 2 x STM-1/4, 2 x GE (T32001.01) 4 x STM-1/4 or 2 x STM-1/4, 2 x GE (T32001.11) CU IP T33001.01 Ethernet interfaces Switching features TDM over IP 2 x 10GE, SFP+ 6 x 1GE, RJ-45 L2 switching L3 routing MPLS-TP SAToP: 63 x E1 Ethernet Unit 1000BT, 8 ports T32002.01 RJ-45 interface SFP interface 6 x 10/100/1000BASE-T Full duplex or half duplex Auto negotiation 4 x PoE 1 x 10/100/1000BASE 1 x 1000BASE E1/T1 Unit, 8 ports, 75 ohm / 120 ohm T32003.01 / T32003.11 E1 G.703/G.704 interface 8 x SMB (T32003.01) 8 x RJ-45 (T32003.11) Data Unit V and X, 4 ports T32004.01 4-port SSC interface V.28, V.11, V.35, X.21, RS-530, RS-530A Data Unit G.703/64k, 8 ports T32004.02 RJ-45 interface 8 x G.703 / 64 kbit/s Optical Teleprotection Unit, 4 ports T32004.11 Optical interfaces 8 x ST connector, 4 ports nx64 kbit/s payload (n = 1 12); multimode fiber; transmission capacity per port: 64 768 kbit/s Protocol IEEE C37.94 2013-2015
DP10001708 8 Technical data - interfaces Optical Teleprotection SFP Unit, 4 ports T32004.12 Optical interfaces 4 x SFP connector, 4 ports nx64 kbit/s payload (n = 1 12); transmission capacity per port: 64 768 kbit/s Transceiver type selected by SFP Digital diagnostics Protocol IEEE C37.94 VF/E&M Unit, 8 ports T32005.01 8-port SSC interface Signaling 8 x 2-wire / 4-wire 3 x E and 3 x M per port FXS Unit, 16 ports T32005.11 RJ-45 interface Integrated ring generator Signaling 8 connectors, 2 ports/connector 25 Hz / 50 Hz R2 / Hot Line FXO Unit, 16 ports T32005.21 RJ-45 interface 8 connectors, 2 ports/connector Advanced DXC Unit T32010.01 Cross-connect capacity Connection types Based on license Maximum cross-connect capacity: 189 x E1 / VC-12 links (equivalent to 63 E1 Y loops) Granularity: 8 kbit/s...nx64 kbit/s, non-blocking B ( point-to-point connection supporting condition bit), Y ( loop protection), C (digital summing), S (VF summing), M (bit masking) Alarm Unit T32011.01 Digital inputs Analog inputs Relay outputs 15 pcs; E&M or TTL; alarm filtering time 10 ms 10 min 4 pcs; measurement scale -120 VDC +120 VDC (accuracy 0.3 V) or 0.0 VDC 3.3 VDC (accuracy 4 mv); alarm filtering time 10 ms 10 min 3 pcs; dry loop or ground connection MultiLine Terminal T32012.01 Line interface Digital interfaces Operating modes 1 x RJ-45; 1 4 pairs; SHDSL/SHDSL.bis Line rate: Up to 5.7 Mbit/s over a single copper pair. With bonded SHDSL.bis, it is possible to deliver 22.8 Mbit/s. 2 x E1; 2 x Fast Ethernet; 2 x V.11/V.24/V.35 Ethernet over TDM; TDM over copper, legacy mode; TDM and Ethernet over copper; Ethernet over copper 2013-2015
DP10001708 9 Technical data mechanics and power supply environmental Subrack 6-Slot T32009.01 Installation capacity 2 4 tributary units Subrack 8+8-Slot /Dynanet T32009.02 Installation capacity 4 6 tributary units Positioned for flexible expansion from PDH to SDH. Easy adaptation from E1 to SDH with existing Nokia s / DNWP s Dynanet units (use of 8 slots). 8 Dynanet slots can be converted to 8 slots. Subrack 16-Slot T32009.04 Installation capacity NOTE! 12 14 tributary units All the above subrack models support CU SDH trunk unit redundancy and also tributary units to be introduced in the later releases of. Also, all subrack models can house 1 or 2 power adapter units. Fan Unit for 6-Slot Subrack T32007.01 Fan Unit for 8+8-Slot /16-Slot Subrack Power Supply AC/DC 2x1kW T32007.02 / T32007.12 (with alarm output) T32006.02 (Emerson NS211/R48-1000) Power Adapter DC 48V T32008.01 Power Adapter DC 24-60/48V T32008.02 Power Adapter DC 48V Bus Extension T32008.11 Environmental specifications Climatic: 6-slot subrack with fan Climatic: 8+8 and 16-slot subrack with fan Climatic: 8+8 and 16-slot subrack without fan and with SDH trunk for Extended Temperature EMC Operation: EN 300 019-1-3, Class 3.1 (-5 to +50 C) Storage: EN 300 019-1-1 Class 1.2 (-25 to +55 C) Transport: EN 300 019-1-2 Class 2.3 (-40 to +70 C) Operation: EN 300 019-1-3, Class 3.2 (-5 to +55 C) Storage: EN 300 019-1-1 Class 1.2 (-25 to +55 C) Transport: EN 300 019-1-2 Class 2.3 (-40 to +70 C) Operation: EN 300 019-1-3, Class 3.1 (-5 to +45 C) Storage: EN 300 019-1-1 Class 1.2 (-25 to +55 C) Transport: EN 300 019-1-2 Class 2.3 (-40 to +70 C) EN 300 386 V1.4.1 1.6.1 EN 50121-4 While we attempt to ensure that the information in this document is up to date and accurate, we do not warrant or accept any responsibility or liability for the accuracy or completeness of the content, or for any loss which may arise from the use of this document. We reserve the right to change the information in this document without prior notice. 2013-2015