StarWind iscsi SAN & NAS:

Similar documents
StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012

StarWind iscsi SAN & NAS:

StarWind iscsi SAN Software: ESX Storage Migration

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server

StarWind Native SAN for Hyper-V:

StarWind iscsi SAN Software: Getting Started with V5

StarWind Native SAN Configuring HA File Server for SMB NAS

StarWind iscsi SAN Software: Using StarWind to provide Cluster Shared Disk resources for Hyper-V Failover Clusters

StarWind iscsi SAN Software: Virtual Tape Library (Part 1)

StarWind iscsi SAN Software: Using StarWind Tape Redirector and CA ARCserve Backup

StarWind Virtual SAN Compute and Storage Separated 3 Nodes with VMware vsphere

StarWind iscsi SAN Software: Using MetaSAN to Share iscsi Volumes

StarPort iscsi and ATA-over-Ethernet Initiator: Using as RAM Disk Emulator

StarWind Virtual CD: Using as DVD-ROM Emulator

StarPort iscsi and ATA-over-Ethernet Initiator: Using as DVD-ROM Emulator

#1 HyperConverged Appliance for SMB and ROBO. StarWind Virtual SAN. Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER

StarWind Virtual SAN HA Devices Configuration Changes

StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016

StarWind Virtual Storage Appliance v2.0 Installation Guide with VMware vsphere

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER

Quick Start Guide: Creating HA Device with StarWind Virtual SAN

StarWind Virtual SAN for vsphere Software RAID Configuration Guide

StarPort iscsi and ATA-over-Ethernet Initiator: Using as ATA-over-Ethernet Initiator

StarWind Virtual SAN Creating Stand-Alone Image File device

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Automating Management with SMI-S in System Center Virtual Machine Manager 2016

StarWind Storage Gateway for Backblaze Getting Started

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016

StarWind Virtual SAN Creating HA device using Node Majority Failover Strategy

StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop

StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V.

StarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018

StarWind Virtual SAN AWS EC2 Deployment Guide

StarWind Virtual SAN Working with StarWind LSFS Snapshots in ESXi

StarWind iscsi Target for Microsoft Windows: Using StarWind iscsi Target and VMware Workstation Virtual Machines

StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER

StarWind Virtual Storage Appliance Installation Guide with KVM

StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication

One Stop Virtualization Shop. StarWind RAM Disk FEBRUARY 2018 TECHNICAL PAPER

StarWind VTL Storage Gateway for Azure and Veeam Installation and Configuration Guide

Using SANDeploy iscsi SAN for VMware ESX / ESXi Server

StarWind Virtual Tape Library Used with Veritas Backup Exec

StarWind iscsi Target for Microsoft Windows: StarWind and Double-Take

StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012

StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016

Quick Start Guide: Creating VTL device with StarWind Virtual SAN

StarWind Virtual SAN VAAI (vstorage API for Array Integration) Configuration and Performance Tuning Guide

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

ESXi Version 5.1 Host

StarWind Virtual SAN Virtual Tape Library on Amazon Web Services with Microsoft System Center Data Protection Manager 2016

StarWind Virtual SAN 2-Node Stretched Cluster on VMware vsphere 6.5

StarWind Virtual SAN 2-Node Stretched Hyper-V Cluster on Windows Server 2016

StarWind Virtual SAN Getting Started

StarWind Appliances Quick Start Guide

StarWind Virtual SAN ODX (Off-loaded Data Transfer) Configuration and Performance Tuning Guide

VMware vsphere 5.5: Install, Configure, Manage Lab Addendum. Lab 3: Configuring VMware ESXi

Dell PowerVault NX1950 configuration guide for VMware ESX Server software

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

iscsi Configuration for ESXi using VSC Express Guide

NexentaStor VVOL

Configuring High Availability for VMware vcenter in RMS All-In-One Setup

Quick Start Guide For Ipswitch Failover v9.0.1

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE

Quick Start Guide. SP Usage Simulator Tool. Evaluating the Performance of SharePoint Environment Using the New DocAve SP Test Environment Creator

EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts

istorage Server: iscsi SAN for ESX/ESXi Server

Managing Virtual Machines

Qsan Document - White Paper. How to configure iscsi initiator in ESXi 6.x

Connect P300H with iscsi initiator in ESX4.0

NetWrix VMware Change Reporter Version 3.0 Enterprise Edition Quick Start Guide

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware

StarWind Virtual SAN. Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2

SANmelody TRIAL Quick Start Guide

NFS Client Configuration with VAAI for ESX Express Guide

Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual

OneSign Virtual Appliance Guide

Configure RSPAN with VMware

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x

StarWind Virtual SAN Supports HA Storage for a vsphere VI with Virtualized iscsi Devices on DAS

StoneFly SCVM Deployment Guide for VMware ESXi

Release Notes and User Guide DataCore vsphere Installation Manager 2.07

VMware vsphere: What s New Lab Manual ESXi 5.5 and vcenter Server 5.5

VMware ESXi Host Configuration

StarWind Virtual SAN Hybrid Cloud for Azure

NetWrix VMware Change Reporter Version 3.0 Enterprise Edition Administrator s Guide

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide

Reset the Admin Password with the ExtraHop Rescue CD

Veritas Access. Installing Veritas Access in VMWare ESx environment. Who should read this paper? Veritas Pre-Sales, Partner Pre-Sales

Vmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version :

StarWind Virtual SAN SQL Server HADR using Availability Groups and Failover Cluster Instance

RSA NetWitness Logs. VMware ESX/ESXi. Event Source Log Configuration Guide. Last Modified: Tuesday, November 7, 2017

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

VMware vsphere with ESX 4 and vcenter

Transcription:

This document refers to the previous StarWind Virtual SAN version. To view the document for the current version, please follow this link StarWind iscsi SAN & NAS: Configuring HA Shared Storage for vsphere October 2012

TRADEMARKS StarWind, StarWind Software, and the StarWind and the StarWind Software logos are trademarks of StarWind Software which may be registered in some jurisdictions. All other trademarks are owned by their respective owners. CHANGES The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, StarWind Software assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. StarWind Software reserves the right to make changes in the product design without reservation and without notification to its users. TECHNICAL SUPPORT AND SERVICES If you have questions about installing or using this software, check this and other documents first - you will find answers to most of your questions on the Technical Papers webpage or in StarWind Forum. If you need further assistance, please contact us. Copyright 2008-2012 StarWind Software Inc. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of StarWind Software. Page 2

CONTENTS INTRODUCTION... 4 CREATING AN HA DEVICE... 5 CONFIGURING ESX SEVERS... 9 CONFIGURING THE ISCSI INITIATOR... 15 SETTING UP A DATASTORE... 17 CONTACTS... 21 Page 3

INTRODUCTION Page 4

CREATING AN HA DEVICE 1. Launch StarWind Management Console: Start -> All Programs -> StarWind Software -> StarWind. Note: The StarWind Console icon appears in the system tray, when the Console is running. To open StarWind Management Console, double-click the icon or right-click it and select Start Management Console from the shortcut menu. 2. Select the server you want to provide with the iscsi target device from the Console tree. 3. Double-click the host to connect. 4. Click Add Device to create devices and targets on the server. 5. Add Device Wizard appears. Please, follow the wizard's steps to complete creation of a new HA device. 6. Go to High Availability Device to select an HA device type. 7. Click Add to add a new host. Enter authentication and host information in the Specify Host dialog. 8. Click Next to continue. 9. Specify corresponding information in the Target Alias and Target Name text fields. Note: The name must be unique. Under this name the device is declared to the iscsi initiators connecting to the StarWind Service over an IP network. Page 5

10. Click to specify name and location of an HA virtual disk on the server. If you want to create new virtual disks, select the Create New checkbox. 11. Click Next to continue. Page 6

12. Configure data synchronization and heartbeat channel parameters. 13. Click Next to continue. 14. Specify cache parameters of the HA device. 15. Click Next to continue. Page 7

16. Select an initialization method of the HA device. 17. Click Next to continue. 18. Check whether device parameters are correct. Click Back to make any changes. 19. Click Next to continue. 20. Click Finish to close the wizard. Page 8

CONFIGURING ESX SEVERS 1. Launch VMware vsphere Client: Start -> All Programs -> VMware -> VMware vsphere Client. 2. Specify IP address of a VMware vcenter Server, enter your login and password. 3. Click Login to enter. 4. Click the Hosts and Clusters icon from the Inventory panel of the vsphere Client window. 5. Right-click an existing datacenter and select New Cluster. If needed, click New Datacenter to create a new datacenter previously. 6. New Cluster Wizard appears. Specify a name of the cluster. Page 9

7. Continue to click Next until the wizard can be closed. 8. Right-click the cluster to add a host. Select the Add Host. 9. Add Host Wizard appears. Specify a host name or IP address, enter username and password. 10. Click Next to continue. 11. Check whether everything is correct, and click Next to continue. 12. Assign the license key to the host. 13. Click Next to continue. 14. Click Finish to close the wizard. 15. Follow the same procedure for another host. 16. Select a host. Page 10

17. Select the Configuration tab and choose the Networking item from the Hardware pane. 18. Click Add Networking. 19. Add Network Wizard appears. Select the VMkernel option. 20. Click Next to continue. Page 11

21. Select Create a vsphere standard switch, and select the appropriate network card checkbox. 22. Click Next to continue. 23. Select the Use this port group for vmotion and Use this port group for management traffic options. 24. Click Next to continue. Page 12

25. Specify IP settings in the relative text fields. 26. Click Next. 27. Click Finish to close the wizard. 28. Follow the same procedure to create the second VMkernel of the third vswitch. Page 13

29. Follow the same procedure for another host in the cluster. Page 14

Configuring the iscsi Initiator 1. Select a host. 2. Click the Configuration tab and select the Storage Adapters item from the Hardware pane. 3. Click Add and select Add software iscsi Adapter. Click OK. 4. The list of the available storage adapters appears. Select iscsi Software Adapter. 5. Click the Properties link. 6. Switch to the Dynamic Discovery tab. Page 15

7. Add each of the StarWind servers by clicking Add and specifying server IP address. 8. Click Close. When prompted to rescan for new iscsi LUNs, click Yes. 9. Follow the same procedure for another cluster host. Page 16

Setting Up a Datastore 1. Select a host from the Console tree. 2. Click the Configuration tab and select the Storage item from the Hardware pane. 3. Click Add Storage. 4. The Add Storage window appears. Select Disk/LUN storage type. 5. Click Next to continue. Page 17

6. Select the device. 7. Click Next to continue. 8. Review the current disk layout. 9. Click Next to continue. 10. Enter a datastore name in the appropriate text field. 12. Click Next to continue. 13. Set the Disk/LUN formatting options. Page 18

14. Click Next to continue. 15. Check whether the device parameters are correct and click Back to make any changes. 16. Click Finish to close the wizard. 17. If everything has been done correctly, a new datastore appears. 18. Check another host for a new datastore. If a new datastore is not displayed in a datastore list, click Rescan All. Page 19

19. Follow the same procedure for another storage device. If everything has been done correctly, a new datastore appears. 20. To add HA feature right-click the cluster and select Edit Settings. 21. In the Cluster Settings window select the Turn on vsphere HA checkbox. 22. Click OK. Page 20

CONTACTS Customer Support Portal: Support Forum: Sales: Sales (Germany): General Information: http://www.starwindsoftware.com/support http://www.starwindsoftware.com/forums sales@starwindsoftware.com vschmidberger@starwindsoftware.com info@starwindsoftware.com US Headquarters Phone: 1-617-449-7717 Fax: 1-617-507-5845 EMEA and APAC Phone: +44-0-2071936727 +44-0-2071936350 +33-0-977197857 (French) Voice Mail: 1-866-790-2646 Germany Monikastr. 13 53757 Sankt Augustin Phone: +49-1715109103 StarWind Software Inc. 40 Mall Rd., Burlington, MA 01803, USA www.starwindsoftware.com Page 21